1.Development and Validation of a High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Detecting Adrenocortical Hormones and Establishment of Age-Stratified Reference Intervals in Reproductive-Aged Women from Guangxi, China
Yixuan LIU ; Tingwei JIN ; Yushuang WEI ; Xuelian QIN ; Siyu DENG ; Jie ZHENG ; Boteng YAN ; Yuanyuan NONG ; Yu YE ; Shengzhu HUANG ; Yu LONG ; Jianmin LI ; Ganqin WANG ; Pei HUANG ; Jinghang JIANG ; Fan WU ; Zengnan MO ; Yonghua JIANG
Annals of Laboratory Medicine 2026;46(2):146-154
Background:
Adrenocortical hormones, particularly 11-oxygenated androgens, are pivotal in female reproductive health and fertility. Standardized detection kits and population-specific reference intervals are lacking in China, hindering related clinical applications.
Methods:
A HPLC-tandem mass spectrometry (HPLC-MS/MS) pipeline was developed, rigorously validated, and applied to simultaneously quantify corticosterone, cortisone, cortisol, 18-OH cortisol, androstenedione (A4), 11β-hydroxyandrostenedione (11-OH A4), dehydroepiandrosterone, and dehydroepiandrosterone sulfate in serum samples from 455 reproductive-aged women (18–45 yrs) in Guangxi, China. Age-dependent concentration trends were analyzed, and reference intervals stratified by age (2.5th to 97.5th percentiles) were established. Correlations with body-composition metrics, ethnicity, and the menstrual cycle were investigated.
Results:
The HPLC-MS/MS method demonstrated high precision (intra- and inter-assay CVs < 15%), accuracy, and sensitivity. All eight hormones exhibited significant age-related declines (P < 0.001 for seven hormones; P = 0.001 for 11-OH A4). Notably, 11-OH A4 levels were significantly lower in the 35–45-yr (3.05 nmol/L) and 25–34-yr (3.09 nmol/L) age groups than in the 18–24-yr (3.57 nmol/L) age group, whereas no significant difference was observed between the 35–45-yr and 25–34-yr age groups. Weak negative correlations were observed between the body mass index and corticosterone and cortisone levels, whereas ethnicity and the menstrual cycle showed no significant associations with hormone levels.
Conclusions
We developed an HPLC-MS/MS-based method for simultaneously quantifying eight adrenocortical hormones, including 11-OH A4, and defined age-specific reference intervals for reproductive-aged Chinese women. These findings advance the clinical utility of adrenocortical hormones in diagnosing and managing reproductive disorders.
2.5G remote robot-assisted thoracoscopic lobectomy/segmentectomy for ten patients
Fan SHEN ; Jia HUANG ; Yu TIAN ; Hanbo PAN ; Jiantao LI ; Long JIANG ; Hong GUO ; Bentong YU ; Qingquan LUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):908-912
Objective To explore the safety and feasibility of 5G remote robot-assisted thoracoscopic anatomic lobectomy and segmentectomy. Methods A retrospective analysis was conducted on patients who underwent 5G remote robot-assisted thoracoscopic anatomic lobectomy or segmentectomy between July and September 2024. The surgeries were performed collaboratively by Shanghai Chest Hospital, Affiliated Hospital of Yangzhou University, and The First Affiliated Hospital of Nanchang University. Perioperative outcomes were recorded and analyzed. Results Ten patients were included, comprising 4 anatomic lobectomies and 6 segmentectomies. The median age was 61.0 (56.0, 72.0) years. The median intraoperative bi-directional network latency was 52.5 (39.0, 54.0) ms. There were no instances of network interruption, robot-related adverse events, or conversions to open thoracotomy. The median postoperative chest tube drainage volume was 500.0 (375.0, 600.0) mL, and the median hospital stay was 5.5 (4.0, 6.0) days. No complications of Clavien-Dindo grade Ⅱor higher occurred. All patients were recurrence-free and alive during the 6-month postoperative follow-up period. Conclusion 5G remote robot-assisted thoracoscopic surgery demonstrates high safety and operational stability. This technology shows promising potential for clinical application and is worthy of further development and utilization.
3.Development and evaluation on reliability and validity of vasectomy intention scale
Zhenyu HUANG ; Yushen LIU ; Enayatullah NABIZADA ; Huleang KEO ; Jianfu YANG ; Dongyi PENG ; Long XU ; Long WANG ; Leye HE ; Xianzhen JIANG ; Zhi LONG
Chinese Journal of Reproduction and Contraception 2025;45(11):1158-1162
Objective:To develop a vasectomy intention scale (VIS) and evaluate its reliability and validity for assessing men's intentions toward vasectomy.Methods:Based on the Theory of Planned Behavior, the VIS was developed through a process that included literature review, panel discussions, expert consultations, and a pilot survey. A total of 264 men seeking vasectomy consultation at the Andrology Center, Department of Urology, the Third Xiangya Hospital of Central South University between December 2023 and December 2024 were recruited to assess reliability and validity of the VIS.Results:The VIS comprises 11 items across three dimensions: "background" factors, "stance and behavior" factors and "information" factors. The scale demonstrated satisfactory internal consistency (Cronbach's α=0.739). Correlations between each dimension and the total scale ("background" factors r=0.849, "stance and behavior" factors r=0.744, "information" factors r=0.440) exceeded inter-dimension correlations (ranging from 0.145 to 0.312), confirming robust construct validity. The vasectomy rates among men with different intention levels were 65.7% (92/140) in the high-intention group, 28.9% (33/114) in the moderate-intention group, and 0% (0/11) in the low-intention group, with a statistically significant difference (χ2=43.42, P<0.001). Conclusion:The VIS exhibits strong reliability and validity, serving as a validated instrument for measuring the strength of men's vasectomy intentions.
4.Construction of a predictive model for estimating the insertion length of peripherally inserted central catheter in very low birth weight infants
Jiaxin LI ; Yubing DONG ; Aifen CAO ; Shan JIANG ; Yingsui HUANG ; Yun LONG ; Xiaoyun XIONG
Chinese Journal of Practical Nursing 2025;41(34):2709-2713
Objective:To develop a formula correlating body weight and the insertion length of peripherally inserted central catheters (PICC) in very low birth weight infants (VLBWI) undergoing lower limb PICC placement, aiming to improve the success rate of one-time catheter placement.Methods:A prospective research method was adopted, 205 VLBWI patients who were hospitalized in the NICU of Shenzhen Maternal and Child Health Hospital from May 2023 to February 2024 and had indwelling PICC in the lower extremities were selected as the research subjects using the convenience sampling method. Data including gender, insertion vein, body weight on the day of catheterization, and the vertical distance from the puncture site to the first popliteal crease were collected. Pearson correlation analysis and linear regression analysis were used to construct a predictive formula for estimating the insertion length of PICC based on body weight. The Bland-Altman plot was applied to evaluate the consistency between the predicted insertion depth using the formula and the actual correct insertion length.Results:A total of 182 VLBWI were included in the study, comprising 102 male infants and 80 female infants. The catheterization sites were the right lower extremity in 166 cases and the left lower extremity in 16 cases. The body weight was (1.08 ± 0.26) kg. The vertical distance from the puncture site to the first popliteal crease was (5.58 ± 1.72) cm. The prediction formula for the length of lower extremity PICC catheterization was constructed through linear regression analysis: PICC insertion length = 8.013 + [5.194×body weight (kg)] ± vertical distance from the puncture site to the popliteal crease (cm). Consistency evaluation showed good agreement between the predicted insertion depth and the actual correct insertion length, with 95% of the measurement differences falling within the limits of agreement. The mean difference was 0.07 cm ( P > 0.05). Conclusions:The weight-based formula derived for VLBWI provides a basis for predicting the optimal insertion length of PICC in clinical practice.
5.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
6.Statistical Parametric Mapping Analysis of Drop Jump Variability in Women with Generalized Joint Hypermobility
Long HUANG ; Wenjuan JIANG ; Lei LI ; Chen LI ; Ye LIU
Journal of Medical Biomechanics 2025;40(4):996-1004
Objective Based on statistical parametric mapping(SPM),to analyze the variability characteristics of lower limb in females with generalized joint hypermobility(GJH)during drop jump.Methods Fifteen females with GJH(GJH group)were recruited based on the Beighton scores,and 15 healthy females(control group)were matched.Kinematic and kinetic data were synchronously collected using the Qualisys infrared motion capture system and Kistler three-dimensional(3D)force platform.Joint angles and torques were computed using OpenSim.Custom Matlab scripts were used to calculate the standard deviation curves of joint angles,and SPM was applied to analyze differences in movement variability between the two groups during the eccentric,coupling,and concentric phases of drop jumps.The maximum joint flexion angles and torques(mean and standard deviation)were calculated to support the findings,and effect sizes were evaluated using Cohen's d.Results Significant differences were observed between the two groups during various phases of drop jumps.In all statistically significant periods,the GJH group exhibited higher joint angle standard deviations compared to the control group(P<0.05).Differences were primarily concentrated in joint flexion movements.During the coupling phase at different heights,the standard deviation of knee joint flexion angles in GJH group consistently exceeded that of control group(P<0.001).Discrete variables showed significant differences in the standard deviation of the maximum knee flexion angles at different heights:At 30 cm,P=0.001,Cohen's d=2.520;at 40 cm,P=0.014,Cohen's d=1.739;and at 50 cm,P=0.005,Cohen's d=1.768.No significant group differences were found in the mean values or standard deviations of the maximum joint flexion angles and torques.Conclusions Females with GJH exhibit higher movement variability during drop jumps compared to healthy females,particularly in knee flexion movements during the coupling phase.Excessive variability reflects insufficient motor control,reducing their ability to resist external disturbances and leading to high-risk movement patterns(e.g.,excessive flexion or knee valgus).
7.Development and evaluation on reliability and validity of vasectomy intention scale
Zhenyu HUANG ; Yushen LIU ; Enayatullah NABIZADA ; Huleang KEO ; Jianfu YANG ; Dongyi PENG ; Long XU ; Long WANG ; Leye HE ; Xianzhen JIANG ; Zhi LONG
Chinese Journal of Reproduction and Contraception 2025;45(11):1158-1162
Objective:To develop a vasectomy intention scale (VIS) and evaluate its reliability and validity for assessing men's intentions toward vasectomy.Methods:Based on the Theory of Planned Behavior, the VIS was developed through a process that included literature review, panel discussions, expert consultations, and a pilot survey. A total of 264 men seeking vasectomy consultation at the Andrology Center, Department of Urology, the Third Xiangya Hospital of Central South University between December 2023 and December 2024 were recruited to assess reliability and validity of the VIS.Results:The VIS comprises 11 items across three dimensions: "background" factors, "stance and behavior" factors and "information" factors. The scale demonstrated satisfactory internal consistency (Cronbach's α=0.739). Correlations between each dimension and the total scale ("background" factors r=0.849, "stance and behavior" factors r=0.744, "information" factors r=0.440) exceeded inter-dimension correlations (ranging from 0.145 to 0.312), confirming robust construct validity. The vasectomy rates among men with different intention levels were 65.7% (92/140) in the high-intention group, 28.9% (33/114) in the moderate-intention group, and 0% (0/11) in the low-intention group, with a statistically significant difference (χ2=43.42, P<0.001). Conclusion:The VIS exhibits strong reliability and validity, serving as a validated instrument for measuring the strength of men's vasectomy intentions.
8.Banxia Xiexin Decoction reshapes tryptophan metabolism to inhibit progression of colon cancer.
Yi-Fang JIANG ; Yu-Qing HUANG ; Heng-Zhou LAI ; Xue-Ke LI ; Liu-Yi LONG ; Feng-Ming YOU ; Qi-Xuan KUANG
China Journal of Chinese Materia Medica 2025;50(5):1310-1320
This study explores the effect and mechanism of Banxia Xiexin Decoction(BXD) in inhibiting colon cancer progression by reshaping tryptophan metabolism. Balb/c mice were assigned into control, model, low-dose BXD(BXD-L), and high-dose BXD(BXD-H) groups. Except the control group, the other groups were subcutaneously injected with CT26-Luc cells for the modeling of colon cancer, which was followed by the intervention with BXD. Small animal live imaging was employed to monitor tumor growth, and the tumor volume and weight were measured. Hematoxylin-eosin(HE) staining was used to observe the pathological changes in mouse tumors. Immunohistochemistry was used to detect Ki67 expression in tumors. Immunofluorescence and flow cytometry were used to detect the infiltration and number changes of CD3~+/CD8~+ T cells in the tumor tissue. Enzyme-linked immunosorbent assay(ELISA) was employed to measure the levels of interferon-gamma(IFN-γ) and interleukin-2(IL-2) in tumors. Targeted metabolomics was employed to measure the level of tryptophan(Trp) in the serum, and the Trp content in the tumor tissue was measured. Western blot and RT-qPCR were employed to determine the protein and mRNA levels, respectively, of indoleamine 2,3-dioxygenase 1(IDO1), MYC proto-oncogene, and solute carrier family 7 member 5(SLC7A5) in the tumor tissue. Additionally, a co-culture model with CT26 cells and CD8~+ T cells was established in vitro and treated with the BXD-containing serum. The cell counting kit-8(CCK-8) assay was used to examine the viability of CT26 cells. The content of Trp in CT26 cells and CD8~+ T cells, as well as the secretion of IFN-γ and IL-2 by CD8~+ T cells, was measured. RT-qPCR was used to determine the mRNA levels of MYC and SLC7A5 in CT26 cells. The results showed that BXD significantly inhibited the tumor growth, reduced the tumor weight, and decreased the tumor volume in the model mice. In addition, the model mice showed sparse arrangement of tumor cells, varying degrees of patchy necrosis, and downregulated expression of Ki67 in the tumor tissue. BXD elevated the levels of IFN-γ and IL-2 in the tumor tissue, while upregulating the ratio of CD3~+/CD8~+ T cells and lowering the levels of Trp, IDO1, MYC, and SLC7A5. The co-culture experiment showed that BXD-containing serum reduced Trp uptake by CT26 cells, increased Trp content in CD8~+T cells, enhanced IL-2 and IFN-γ secretion of CD8~+T cells, and down-regulated the mRNA levels of MYC and SLC7A5 in CT26 cells. In summary, BXD can inhibit the MYC/SLC7A5 pathway to reshape Trp metabolism and adjust Trp uptake by CD8~+ T cells to enhance the cytotoxicity, thereby inhibiting the development of colon cancer.
Animals
;
Tryptophan/metabolism*
;
Colonic Neoplasms/pathology*
;
Mice
;
Drugs, Chinese Herbal/administration & dosage*
;
Mice, Inbred BALB C
;
Humans
;
Cell Line, Tumor
;
Indoleamine-Pyrrole 2,3,-Dioxygenase/metabolism*
;
Female
;
Disease Progression
;
Cell Proliferation/drug effects*
;
Proto-Oncogene Mas
;
Male
9.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
10.Application strategies and clinical effects of superior gluteal artery perforator tissue flaps in repairing stage Ⅳ pressure ulcers in the sacrococcygeal region
Rufei DENG ; Baowen FAN ; Songhua SONG ; Luyao LONG ; Yanwei CHEN ; Jiaxin CHEN ; Ruchen JI ; Yonghong ZHANG ; Xiangtian HU ; Guoneng HUANG ; Zhenyu JIANG ; Lan JIANG ; Lijin ZOU ; Guohua XIN ; Yuanlin ZENG ; Youlai ZHANG
Chinese Journal of Burns 2025;41(3):232-241
Objective:To explore the application strategies and clinical effects of superior gluteal artery perforator tissue flaps in repairing stage Ⅳ pressure ulcers in the sacrococcygeal region.Methods:This study was a retrospective observational study. From July 2019 to April 2024, 89 patients with stage Ⅳ pressure ulcers in the sacrococcygeal region who met the inclusion criteria were admitted to the First Affiliated Hospital of Nanchang University, including 59 males and 30 females, aged 21 to 84 years. There were 89 sacrococcygeal pressure ulcers, with an area of 5.0 cm×4.0 cm-21.0 cm×21.0 cm after debridement. According to the shape, size, and depth of the wounds after debridement, combined with the elasticity and texture of the skin around the wounds, and the principle of minimizing damage to the donor area, the appropriate forms of superior gluteal artery perforator tissue flaps were cut for wound repair in the following three conditions. (1) For wounds with a round shape, an area of 5.0 cm×5.0 cm-21.0 cm×21.0 cm, and a depth of 1.0-3.5 cm, the superior gluteal artery perforator propeller flap or myocutaneous flap, bilobed superior gluteal artery perforator relay flap, and bilateral superior gluteal artery perforator rotational flap were used. (2) For wounds with an oval shape, an area of 5.0 cm×4.0 cm-18.5 cm×10.5 cm, and a depth of 1.0-3.0 cm, the superior gluteal artery perforator propeller flap or myocutaneous flap, unilateral superior gluteal artery perforator propeller flap combined with contralateral superior gluteal artery perforator V-Y advanced flap or keystone flap were used. (3) For wounds with a fusiformis shape, an area of 7.0 cm×4.0 cm-17.5 cm×6.0 cm, and a depth of 1.5-5.0 cm, the unilateral or bilateral superior gluteal artery perforator V-Y advanced flap, superior gluteal artery perforator keystone flap, or superior gluteal artery perforator keystone flap combined with gluteus maximus muscle flap were used. In this group of patients, a total of 40 superior gluteal artery perforator propeller flaps (with an resection area of 11.0 cm×6.0 cm-17.0 cm×11.0 cm), 22 superior gluteal artery perforator propeller myocutaneous flaps (with an resection area of 10.0 cm×5.0 cm-14.0 cm×8.0 cm), 7 bilobed superior gluteal artery perforator relay flaps (with a main flap resection area of 5.5 cm×5.5 cm-18.0 cm×11.5 cm and a side flap resection area of 4.5 cm×3.0 cm-11.0 cm×6.5 cm), 5 bilateral superior gluteal artery perforator rotational flaps (with a total resection area of 20.0 cm×16.0 cm-26.0 cm×21.0 cm on both sides), 14 superior gluteal artery perforator V-Y advanced flaps (with an resection area of 12.0 cm×10.0 cm-18.0 cm×18.0 cm), 13 superior gluteal artery perforator keystone flaps (with an resection area of 13.0 cm×6.5 cm-19.0 cm×18.0 cm), and 3 gluteus maximus muscle flaps (with an resection area of 8.0 cm×3.0 cm-15.0 cm×4.5 cm). The donor area wounds were all directly sutured. The survival of tissue flaps was observed and the incidence rate of delayed wound healing in the reception area was calculated, and wound healing in the donor area was observed. The appearance and texture of tissue flaps and recurrence of pressure ulcers were followed up.Results:After surgery, all bilateral superior gluteal artery perforator rotational flaps, superior gluteal artery perforator V-Y advanced flaps, superior gluteal artery perforator keystone flaps, and gluteus maximus muscle flaps survived well. There were 6 cases of delayed wound healing in the reception area after surgery, with an incidence rate of 6.7% (6/89). Two patients had incision dehiscence in the donor area wounds due to postoperative bleeding, the wounds healed after debridement, vacuum sealing drainage, and dressing change. The wounds in the donor area of the remaining patients healed well. Six patients were lost to follow-up. Eighty-three patients were followed up for 3-48 months, of whom 4 patients died. Among the remaining 79 patients, 3 cases had pressure ulcers recur due to improper nursing, while the rest of the patients had tissue flaps with good appearance and soft texture and no recurrence of pressure ulcers.Conclusions:Based on the characteristics of wound shape, size, and depth after debridement of stage Ⅳ pressure ulcers in the sacrococcygeal region, individualized selection of flap, myocutaneous flap, or a combination of flap and gluteus maximus muscle flap based on the perforating branch of the superior gluteal artery perforator can achieve good clinical repair results. The postoperative tissue flap survived well, with a good appearance, soft texture, and less recurrence of pressure ulcers.

Result Analysis
Print
Save
E-mail