1.Analysis of completion rate of tumor evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer : a national multicenter real-world study
Kexuan LI ; Tixian XIAO ; Xiaodong WANG ; Bin WU ; Guole LIN ; Yuchen GUO ; Ming QU ; Si WU ; Xiaodong YANG ; Yinshengbo′er BAO ; Baohua WANG ; Fan ZHANG ; Xiangwang YU ; Beizhan NIU ; Junyang LU ; Lai XU ; Guannan ZHANG ; Zhen SUN ; Guoyou ZHANG ; Yan SHI ; Hong JIANG ; Yongjing TIAN ; Yongxiang LI ; Hongwei YAO ; Jun XUE ; Quan WANG ; Lie YANG ; Qian LIU ; Yi XIAO
Chinese Journal of Digestive Surgery 2025;24(1):113-119
Objective:To investigate the completion rate of tumor evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer patients in the national multicenter real-world database.Methods:The prospective real-world study was conducted. The clinicopathological data of 1 074 patients who underwent surgical treatment for mid and low rectal cancer in 47 national medical institutions, including Peking Union Medical College Hospital et al, from May 12,2023 to May 11,2024 were collected. Observation indicators: (1) clinical characteristics of patients with mid and low rectal cancer; (2) initial colonoscopy and pathologic evaluation of tumors in patients with mid and low rectal cancer; (3) initial imaging evaluation of patients with mid and low rectal cancer; (4) imaging evaluation after neoadjuvant therapy for patients with mid and low rectal cancer. Measurement data with normal distribution were represented as Mean± SD, and measurement data with skewed distribution were represented as M( Q1, Q3). Count data were described as absoluter numbers and/or percentages. Results:(1) Clinical characteristics of patients with mid and low rectal cancer. Of the 1 074 patients, there were 713 males and 361 females, aged 63(56,70)years. The body mass index of 1 074 patients was 24(21,26)kg/m 2.For American Society of Anesthesiologists classification, there were 147 cases of stage Ⅰ, 641 cases of stage Ⅱ, 157 cases of stage Ⅲ, 2 cases of stage Ⅳ, and there were 127 cases missing data. (2) Initial colonoscopy and pathologic evaluation of tumors in patients with mid and low rectal cancer. Of the 1 074 patients, there were 787 cases (73.28%) undergoing complete colonoscopy, and there were only 197 cases (18.34%) undergoing immunohistochemical evaluation of all four mismatch repair proteins. (3) Initial imaging evaluation of patients with mid and low rectal cancer. Of the 1 074 patients, there were 842(78.40%) patients completing magnetic resonance imaging (MRI) or ultrasound evaluation, and there were 914(85.10%) patients completing chest, abdomen, and pelvis enhanced computed tomography (CT) evaluation. In the 149 patients completing rectal ultrasound evaluation, there were 122 cases (81.88%) comple-ting T staging evaluation, and there were 81 cases (54.36%) completing N staging evaluation. In the 808 patients completing rectal MRI evaluation, there were 708 cases (87.62%) completing T staging evaluation, and there were 590 cases (73.02%) completing N staging evaluation. (4) Imaging evalua-tion after neoadjuvant therapy for patients with mid and low rectal cancer. Of the 388 patients with neoadjuvant therapy, there were 332 patients (85.57%) completing MRI or ultrasound evaluation, and there were 327 patients (84.28%) completing chest, abdomen, and pelvis enhanced CT evalua-tion. In the 70 patients completing rectal ultrasound evaluation, there were 65 cases (92.86%) com-pleting T staging evaluation, and there were 49 cases (70.00%) completing N staging evaluation. In the 327 patients completing rectal MRI evaluation, there were 246 cases (75.23%) completing T staging, and there were 228 cases (69.72%) completing N staging evaluation. Conclusion:The com-pletion rate of tumor imaging evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer patients on a national scale is relatively good.
2.Study of the effect of self-perceived hearing status on depression in middle-aged and older people in the community
Yaoyao HUANG ; Dahui WANG ; Chenxi MAO ; Yang YI ; Geyao HUANG ; Shihao JIANG ; Yuchen ZHOU ; Hongkun CHEN ; Yuhuan SUN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2025;60(9):1154-1162
Objective:Hearing loss can seriously affect mental health status, and this study aims to investigate the influence of hearing health status on depressive symptoms among middle-aged and older individuals in the community.Methods:From June to December 2023, a stratified random sampling method was employed to select 1 238 community-dwelling middle-aged and elderly people aged 45 years and above from four cities (Hangzhou, Shanghai, Baoding, and Zhengzhou) as research subjects. A questionnaire survey was conducted to collect the subjects′ basic information, hearing health status [assessed by the Hearing Handicap Inventory for Adults-Screening Version (HHIA-S)], and depressive symptoms [assessed by the Geriatric Depression Scale-15 (GDS-15)]. T-tests, rank-sum tests and chi-square tests were used for univariate analysis, while, multiple linear regression and binary Logistic regression were applied to analyze the relationship between hearing health status and depressive symptoms.Results:A total of 1 183 community-dwelling middle-aged and elderly people aged 45 years and above were included in the final analysis (464 males and 719 females, aged from 45 to 96 years). The detection rate of hearing loss was 35.3%(418/1 183), while, the detection rate of depressive symptoms was 9.89%(117/1 183). Age, level of interaction with children, self-rated health, perceived loneliness, and hearing health significantly influenced depressive symptoms among older adults residing in the community ( P<0.05). Individuals with moderate to severe hearing loss ( β=2.04, 95% CI: 1.47, 2.62) exhibited higher GDS-15 scores compared to those without hearing impairment. Furthermore, after correcting for sex, age, marital status, monthly per capita family income, education, residence, smoking status, alcohol use, use of psychotropic medication (anxiolytic or depressant), number of illness, self-health assessment, and autonomy, middle-aged and older adults with mild to moderate hearing loss ( OR=2.89, 95% CI: 1.76, 4.88) and severe hearing loss ( OR=5.79, 95% CI: 3.05, 11.01) demonstrated an increased likelihood of experiencing depression. Conclusions:The degree of hearing loss in community-dwelling middle-aged and elderly individuals is closely associated with the risk of depressive symptoms. Therefore, it is imperative to enhance hearing health screening and to provide mental health support to individuals with hearing loss, in order to mitigate the onset and progression of depressive symptoms.
3.Personalized GYROID condylar prosthesis:design and finite element analysis
Danyu LIU ; Tingting JIANG ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Lei WANG ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(17):3548-3556
BACKGROUND:Currently,the mandibular joint prosthesis manufactured at home and abroad needs to rely on screws to fix the condylar part of the prosthesis during the replacement process,and the retention hole is reserved to facilitate the operation during the operation.However,due to the lack of personalized jaw design,the reattachment plate may not fit the jaw,resulting in screw loosening and dislocation.Therefore,personalized condylar prosthesis replacement is of great value in the repair of the temporomandibular joint.OBJECTIVE:To design a personalized condylar prosthesis with an internal GYROID for mandibular condylar repair and reconstruction.METHODS:The GYROID structure was selected in the Rhinoceros 7 software with the single cell size of 6 mm and the wall thickness of 0.2,0.3,0.4,0.5,0.6,0.7,0.8 mm.The mechanical properties of the GYROID structure were analyzed by finite element method.3D printing of GYROID structural test specimens with different wall thickness(0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was performed to test the mechanical properties of the specimens through room temperature compression experiments.A wall thickness value conforming to the range of mandibular mechanical properties was selected through finite element analysis and room temperature compression test results.An adult male mandibular CT data were used for inverse modeling to design a condylar prosthesis with an internal GYROID.Finite element analysis was used to simulate the movement of the apical staggered position and the opposite-blade jaw position after condylar prosthesis replacement.RESULTS AND CONCLUSION:(1)The results of finite element analysis and room temperature compression experiment showed that the elastic modulus of the GYROID structure increased with the increase of wall thickness.The elastic modulus of the GYROID structure with wall thickness of 0.5-0.7 mm was within the range of the elastic modulus of the mandible(1.5-4.0 GPa).Therefore,the 6 mm monocellular GYROID structural model with a wall thickness of 0.6 mm was selected for the design of the condylar prosthesis.(2)The results of finite element analysis showed that the stress distribution of mandibular model was symmetrical.The stress distribution of the two types of occlusion was roughly the same,and the stress peak was not significantly different.The stress concentrated in the neck of the condylar prosthesis,and the stress on the replacement side was slightly larger than that on the healthy side.The maximum equivalent stress of the whole internal fixation model was 269.34 MPa,and the maximum equivalent stress of the screw was 20.14 MPa.The equivalent stress and equivalent strain values of the prosthesis were greater than that of the opposite edge jaw position when the tooth tip was interlaced.The equivalent stress and equivalent strain values of the screw were smaller than that of the opposite edge jaw position when the tooth tip was interlaced.(3)The results showed that the design and retention of the personalized GYROID condylar prosthesis were good,which was consistent with the mechanical conduction of the mandible.
4.Biomechanical properties of Gyroid structured titanium bionic bone scaffolds for repairing segmental mandibular defects
Zhixiu JIANG ; Yuchen JI ; Danyu LIU ; Yilin CAO ; Tingting JIANG ; Yihan SONG ; Lei WANG ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(22):4621-4628
BACKGROUND:Porous structures based on triple periodic minimal surfaces are one of the most promising orthopedic biostructures,among which the Gyroid structure is characterized by high specific surface area,high permeability,and zero mean curvature.OBJECTIVE:To screen the wall thickness interval of TC4 bionic bone scaffolds with 4 mm single-cell Gyroid structure matching the elastic modulus range of cancellous bone of the mandible through finite element analysis combined with mechanical compression test testing.METHODS:The finite element model of the 4 mm single-cell Gyroid structure with different wall thickths(0.1,0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was established.The equivalent elastic modulus of the Gyroid structure was analyzed,and the wall thickness interval of the Gyroid structure matching the elastic modulus range of the maxillary resinous bone was selected with different wall thicknesses of 0.2,0.3,0.4,0.5,0.6,and 0.7 mm,respectively.According to finite element analysis screening results,the material selected was Ti6Al4V.Selective laser melting was used to prepare 3D printed Gyroid structure specimens.The surface treatment was carried out by large-grained sand blasting and acid etching.The elastic modulus and compressive strength of the specimen were tested by mechanical compression experiment.RESULTS AND CONCLUSION:(1)The finite element analysis results showed that the equivalent elastic modulus of the Gyroid structure increased with the increase of wall thickness,and the equivalent elastic modulus of the Gyroid structure with wall thickness of 0.2-0.7 mm was within the range of the elastic modulus of the spongy bone of the mandible(1.5-4.0 GPa),which was used for 3D printing of the Gyroid structure specimen.(2)The mechanical compression test results showed that the elastic modulus and compressive strength of the Gyroid structural specimen increased with the increase of wall thickness,and the elastic modulus of the Gyroid structural specimen with wall thickness of 0.3-0.5 mm was within the range of the elastic modulus of the cancellous bone of the mandible.The compressive strength of the Gyroid specimen with 0.3-0.7 mm wall thickness was consistent with the mechanical properties of the mandible.(3)The results show that the Gyroid structure of 0.3-0.5 mm wall thickness is compatible with the range of elastic modulus of the mandible.
5.Personalized GYROID condylar prosthesis:design and finite element analysis
Danyu LIU ; Tingting JIANG ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Lei WANG ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(17):3548-3556
BACKGROUND:Currently,the mandibular joint prosthesis manufactured at home and abroad needs to rely on screws to fix the condylar part of the prosthesis during the replacement process,and the retention hole is reserved to facilitate the operation during the operation.However,due to the lack of personalized jaw design,the reattachment plate may not fit the jaw,resulting in screw loosening and dislocation.Therefore,personalized condylar prosthesis replacement is of great value in the repair of the temporomandibular joint.OBJECTIVE:To design a personalized condylar prosthesis with an internal GYROID for mandibular condylar repair and reconstruction.METHODS:The GYROID structure was selected in the Rhinoceros 7 software with the single cell size of 6 mm and the wall thickness of 0.2,0.3,0.4,0.5,0.6,0.7,0.8 mm.The mechanical properties of the GYROID structure were analyzed by finite element method.3D printing of GYROID structural test specimens with different wall thickness(0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was performed to test the mechanical properties of the specimens through room temperature compression experiments.A wall thickness value conforming to the range of mandibular mechanical properties was selected through finite element analysis and room temperature compression test results.An adult male mandibular CT data were used for inverse modeling to design a condylar prosthesis with an internal GYROID.Finite element analysis was used to simulate the movement of the apical staggered position and the opposite-blade jaw position after condylar prosthesis replacement.RESULTS AND CONCLUSION:(1)The results of finite element analysis and room temperature compression experiment showed that the elastic modulus of the GYROID structure increased with the increase of wall thickness.The elastic modulus of the GYROID structure with wall thickness of 0.5-0.7 mm was within the range of the elastic modulus of the mandible(1.5-4.0 GPa).Therefore,the 6 mm monocellular GYROID structural model with a wall thickness of 0.6 mm was selected for the design of the condylar prosthesis.(2)The results of finite element analysis showed that the stress distribution of mandibular model was symmetrical.The stress distribution of the two types of occlusion was roughly the same,and the stress peak was not significantly different.The stress concentrated in the neck of the condylar prosthesis,and the stress on the replacement side was slightly larger than that on the healthy side.The maximum equivalent stress of the whole internal fixation model was 269.34 MPa,and the maximum equivalent stress of the screw was 20.14 MPa.The equivalent stress and equivalent strain values of the prosthesis were greater than that of the opposite edge jaw position when the tooth tip was interlaced.The equivalent stress and equivalent strain values of the screw were smaller than that of the opposite edge jaw position when the tooth tip was interlaced.(3)The results showed that the design and retention of the personalized GYROID condylar prosthesis were good,which was consistent with the mechanical conduction of the mandible.
6.Biomechanical properties of Gyroid structured titanium bionic bone scaffolds for repairing segmental mandibular defects
Zhixiu JIANG ; Yuchen JI ; Danyu LIU ; Yilin CAO ; Tingting JIANG ; Yihan SONG ; Lei WANG ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(22):4621-4628
BACKGROUND:Porous structures based on triple periodic minimal surfaces are one of the most promising orthopedic biostructures,among which the Gyroid structure is characterized by high specific surface area,high permeability,and zero mean curvature.OBJECTIVE:To screen the wall thickness interval of TC4 bionic bone scaffolds with 4 mm single-cell Gyroid structure matching the elastic modulus range of cancellous bone of the mandible through finite element analysis combined with mechanical compression test testing.METHODS:The finite element model of the 4 mm single-cell Gyroid structure with different wall thickths(0.1,0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was established.The equivalent elastic modulus of the Gyroid structure was analyzed,and the wall thickness interval of the Gyroid structure matching the elastic modulus range of the maxillary resinous bone was selected with different wall thicknesses of 0.2,0.3,0.4,0.5,0.6,and 0.7 mm,respectively.According to finite element analysis screening results,the material selected was Ti6Al4V.Selective laser melting was used to prepare 3D printed Gyroid structure specimens.The surface treatment was carried out by large-grained sand blasting and acid etching.The elastic modulus and compressive strength of the specimen were tested by mechanical compression experiment.RESULTS AND CONCLUSION:(1)The finite element analysis results showed that the equivalent elastic modulus of the Gyroid structure increased with the increase of wall thickness,and the equivalent elastic modulus of the Gyroid structure with wall thickness of 0.2-0.7 mm was within the range of the elastic modulus of the spongy bone of the mandible(1.5-4.0 GPa),which was used for 3D printing of the Gyroid structure specimen.(2)The mechanical compression test results showed that the elastic modulus and compressive strength of the Gyroid structural specimen increased with the increase of wall thickness,and the elastic modulus of the Gyroid structural specimen with wall thickness of 0.3-0.5 mm was within the range of the elastic modulus of the cancellous bone of the mandible.The compressive strength of the Gyroid specimen with 0.3-0.7 mm wall thickness was consistent with the mechanical properties of the mandible.(3)The results show that the Gyroid structure of 0.3-0.5 mm wall thickness is compatible with the range of elastic modulus of the mandible.
7.Design of customized Gyroid condylar prosthesis and finite element analysis of articular disc
Tingting JIANG ; Danyu LIU ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(28):6003-6011
BACKGROUND:Condylar prosthesis replacement,as one of the surgical methods for the treatment of temporomandibular joint diseases,not only needs to restore the morphology and function,but also needs to ensure long-term stable application.OBJECTIVE:To design finite element analysis of a customized Gyroid condylar prosthesis.METHODS:Gyroid structure specimens with different wall thicknesses(250,350,450,550,650,and 750 μm)were designed by software.Finite element simulation compression experiments were carried out to test the elastic modulus of the specimens.The Gyroid structure wall thickness range that matches the elastic modulus of mandibular cancellous bone and whose pore size meets the osteogenesis conditions was screened out.This range was subdivided and Gyroid structure specimens were made using 3D printing technology.Mechanical compression experiments were carried out on a universal testing machine.The Gyroid structure wall thickness that meets the mechanical properties of mandibular bone,has an easier osteogenesis and a smaller strength was screened out by elastic modulus and compressive strength,and subsequent experiments were carried out.A three-dimensional model of a customized Gyroid condylar prosthesis was designed,and the finite element analysis of the blade jaw position and cusp interdigitation position of the model under natural occlusion was simulated.RESULTS AND CONCLUSION:(1)Finite element analysis results showed that with the increase of wall thickness,the elastic modulus of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 350,450,550,650,and 750 μm matched the elastic modulus of mandibular cancellous bone.Since the subsequent experiments needed to be subdivided into groups and the pore size of the 550,650,and 750 μm wall thickness group(pore size 800-1 000 μm)was within the osteogenesis range.Gyroid structure specimens with wall thickness of 550,600,650,700,and 750μm were selected for mechanical compression experiments on a universal testing machine.(2)The results of mechanical compression experiments showed that with the increase of wall thickness,the elastic modulus and compressive strength of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 550,600,and 650 μm was within the elastic modulus of the mandibular cancellous bone.Finally,the wall thickness of 650 μm and the pore size of 900 μm were selected to construct the three-dimensional model of the mandibular customized Gyroid condylar prosthesis.(3)The results of finite element analysis of three-dimensional model of the mandibular customized Gyroid condylar prosthesis showed that the stress of the articular disc in the edge-to-edge occlusion was mainly concentrated on the lower surface of the anterior middle band,and the stress of the articular disc in the interposition of tooth tips was mainly concentrated on the lateral surface of the lower surface.The maximum displacement and the maximum equivalent stress of the left and right articular discs in the edge-to-edge occlusion and the interposition of tooth tips were similar.The maximum displacement was 0.031,0.030,0.028,and 0.018 mm,and the maximum equivalent stress was 2.87,2.30,2.73,and 1.71 MPa,respectively.(4)The results showed that the Gyroid structure with a wall thickness of 650 μm was consistent with the mechanical properties of the mandible,which reduced the strength of the titanium alloy and reduced the damage of the articular disc caused by the customized Gyroid condylar prosthesis.
8.Analysis of completion rate of tumor evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer : a national multicenter real-world study
Kexuan LI ; Tixian XIAO ; Xiaodong WANG ; Bin WU ; Guole LIN ; Yuchen GUO ; Ming QU ; Si WU ; Xiaodong YANG ; Yinshengbo′er BAO ; Baohua WANG ; Fan ZHANG ; Xiangwang YU ; Beizhan NIU ; Junyang LU ; Lai XU ; Guannan ZHANG ; Zhen SUN ; Guoyou ZHANG ; Yan SHI ; Hong JIANG ; Yongjing TIAN ; Yongxiang LI ; Hongwei YAO ; Jun XUE ; Quan WANG ; Lie YANG ; Qian LIU ; Yi XIAO
Chinese Journal of Digestive Surgery 2025;24(1):113-119
Objective:To investigate the completion rate of tumor evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer patients in the national multicenter real-world database.Methods:The prospective real-world study was conducted. The clinicopathological data of 1 074 patients who underwent surgical treatment for mid and low rectal cancer in 47 national medical institutions, including Peking Union Medical College Hospital et al, from May 12,2023 to May 11,2024 were collected. Observation indicators: (1) clinical characteristics of patients with mid and low rectal cancer; (2) initial colonoscopy and pathologic evaluation of tumors in patients with mid and low rectal cancer; (3) initial imaging evaluation of patients with mid and low rectal cancer; (4) imaging evaluation after neoadjuvant therapy for patients with mid and low rectal cancer. Measurement data with normal distribution were represented as Mean± SD, and measurement data with skewed distribution were represented as M( Q1, Q3). Count data were described as absoluter numbers and/or percentages. Results:(1) Clinical characteristics of patients with mid and low rectal cancer. Of the 1 074 patients, there were 713 males and 361 females, aged 63(56,70)years. The body mass index of 1 074 patients was 24(21,26)kg/m 2.For American Society of Anesthesiologists classification, there were 147 cases of stage Ⅰ, 641 cases of stage Ⅱ, 157 cases of stage Ⅲ, 2 cases of stage Ⅳ, and there were 127 cases missing data. (2) Initial colonoscopy and pathologic evaluation of tumors in patients with mid and low rectal cancer. Of the 1 074 patients, there were 787 cases (73.28%) undergoing complete colonoscopy, and there were only 197 cases (18.34%) undergoing immunohistochemical evaluation of all four mismatch repair proteins. (3) Initial imaging evaluation of patients with mid and low rectal cancer. Of the 1 074 patients, there were 842(78.40%) patients completing magnetic resonance imaging (MRI) or ultrasound evaluation, and there were 914(85.10%) patients completing chest, abdomen, and pelvis enhanced computed tomography (CT) evaluation. In the 149 patients completing rectal ultrasound evaluation, there were 122 cases (81.88%) comple-ting T staging evaluation, and there were 81 cases (54.36%) completing N staging evaluation. In the 808 patients completing rectal MRI evaluation, there were 708 cases (87.62%) completing T staging evaluation, and there were 590 cases (73.02%) completing N staging evaluation. (4) Imaging evalua-tion after neoadjuvant therapy for patients with mid and low rectal cancer. Of the 388 patients with neoadjuvant therapy, there were 332 patients (85.57%) completing MRI or ultrasound evaluation, and there were 327 patients (84.28%) completing chest, abdomen, and pelvis enhanced CT evalua-tion. In the 70 patients completing rectal ultrasound evaluation, there were 65 cases (92.86%) com-pleting T staging evaluation, and there were 49 cases (70.00%) completing N staging evaluation. In the 327 patients completing rectal MRI evaluation, there were 246 cases (75.23%) completing T staging, and there were 228 cases (69.72%) completing N staging evaluation. Conclusion:The com-pletion rate of tumor imaging evaluation at initial assessment and after neoadjuvant therapy for mid and low rectal cancer patients on a national scale is relatively good.
9.Study on Key Quality Control Indicators and Antioxidant Activity of Typical Propolis Samples from domestic and Abroad
Mengyuan WANG ; Dongping YUAN ; Qiumei WU ; Xiaowen RUAN ; Yuchen JIANG ; Jiwen YANG ; Tao LI ; Xuan LI
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(4):522-530
OBJECTIVE To analyze the ethanol extracts,total phenols,total flavonoids contents and HPLC fingerprints of typi-cal propolis samples from 6 foreign countries and 5 domestic regions,optimize the extraction process and evaluate the antioxidant activi-ty,so as to provide data support for improving the quality control system of propolis.METHODS The optimization of the propolis ex-traction process utilized flavonoid content as an indicator.Three flavonoid detection methods-namely,the aluminum trichloride meth-od,aluminum nitrate method,and polyamide method-were compared.The content of ethanol extract,total phenol content,and the scavenging ability of DPPH free radicals for each sample were determined.Further analysis was conducted using HPLC fingerprint pro-filing.RESULTS The propolis extract with the highest flavonoid content was obtained using 80%ethanol as the extraction solvent,operating at 50℃,with a stirring time of 3 h,ultrasonic power of 180 W,and ultrasonic time of 15 min.The aluminum trichloride method was proved to be the most effective for determining total flavonoids in propolis.While the ethanol extract,total flavonoids,and total phenols of propolis from Xinjiang,China were relatively low,their antioxidant activity exhibited superiority.HPLC analysis re-vealed,Brazilian red propolis lacked of chrysin,galangin,caffeic acid phenethyl ester and Brazilian green propolis lacked ferulic acid,apigenin,p-coumaric acid,chrysin,and pinocembrin.In contrast,the content of these four compounds in other samples varied,with the antioxidant capacity of the extracts not precisely corresponding to the compound content.CONCLUSION Propolis exhibits a complex chemical composition with significant variations among varieties.Key quality control indexes must be comprehensively consid-ered,encompassing physicochemical characteristics and biological activity.Establishing a multi-angle assessment system with a mate-rial basis-functional linkage is essential.This approach facilitates the realization of high quality and cost-effectiveness,thereby promo-ting the healthy development of the industry.
10.Correlation Between Cardiovascular Events and Traditional Chinese Medicine Syndrome in Patients with Rheumatoid Arthritis:A Cross-Sectional Study
Fuyuan ZHANG ; Quan JIANG ; Jun LI ; Yuchen YANG ; Xieli MA ; Tian CHANG ; Congmin XIA ; Jian WANG ; Xun GONG
Journal of Traditional Chinese Medicine 2025;66(15):1572-1578
ObjectiveTo explore the correlation between the occurrence of cardiovascular events in rheumatoid arthritis(RA) and traditional Chinese medicine(TCM) syndrome. MethodsThe cross-sectional study selected 6713 RA patients from 122 centres nationwide, in which general information such as name, gender, age, height, body weight, and course of disease were collected by completing a questionnaire; patients were classified into eight types of syndrome according to the information of their four examinations,i.e. wind-dampness obstruction syndrome, cold-dampness obstruction syndrome, dampness-heat obstruction syndrome, phlegm-stasis obstruction syndrome, stasis-blood obstructing collateral syndrome, qi-blood deficiency syndrome, liver-kidney insufficiency syndrome, and qi-yin deficiency syndrome. According to the occurrence of cardiovascular events, they were divided into the occurrence group and the non-occurrence group, and the condition assessment data and laboratory examination indexes were recorded. The test of difference between groups was used to analyse the possible risk factors for the occurrence of RA cardiovascular events, and binary logistic regression was used to analyse the correlation between TCM syndromes and RA cardiovascular events. ResultsA total of 6713 RA patients were included, including 256 cases in occurrence group and 6457 in non-occurrence group. There was no statistically significant difference between groups in terms of height, gender, insomnia, appetite, white blood cell(WBC), hemoglobin(HGB), platelets(PLT), rheumatoid factor(RF), anti-cyclic peptide containing citrulline(CCP), alanine aminotransferase(ALT), aspartate aminotransferase(AST), γ-glutamyl transpeptidase(GGT), urea creatinine(CREA), and glucose(GLU)(P>0.05). The TCM syndromes between groups showed significant statistic differences(P<0.05). Patients in occurrence group had longer disease duration, heavier body weight, and older age; more severe conditions such as disease activity(DAS-28), number of painful joints(TJC), number of swollen joints(SJC), health questionnaire scores(HAQ), visual analog scores(VAS), restlessness, and fatigue; higher blood sedimentation rate(ESR), low-density lipoprotein(LDL-C), triglyceride(TG), total cholesterol(TC), D-Dimer, and lower high-density lipoprotein(HDL-C)(P<0.05). The distribution of syndrome types showed that dampness-heat obstruction syndrome accounted for the largest proportion of patients in both groups and was higher in RA cardiovascular events. Logistic regression analysis showed that the occurrence of RA cardiovascular events was strongly associated with dampness-heat obstruction syndrome[OR=5.937, 95%CI (4.434, 7.949), P<0.001]. ConclusionThe occurrence of RA cardiovascular events were associated with TCM syndromes, and the probability of cardiovascular events in the RA patients with dampness-heat obstruction syndrome was 5.937 times higher than patients with other TCM syndromes.

Result Analysis
Print
Save
E-mail