1.Molecular Mechanisms of Salvia Miltiorrhiza and Its Active Ingredients against Colorectal Cancer: A Review
Jianing GUO ; Xiaochen NI ; Kaiyuan ZHANG ; Wei FAN ; Chuhang WANG ; Chao XU ; Jianbo HUANG ; Tao JIANG ; Guangji ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(4):307-314
Colorectal cancer (CRC) is one of the most common cancers, with its incidence ranking high among cancers. It stands as the second leading cause of cancer-related death worldwide. In the early stages, CRC lacks specific symptoms, and most patients are diagnosed at advanced stages, making it a major research focus in the field of gastrointestinal tumors. Currently, clinical CRC treatments face several common challenges, including high surgical risks, frequent metastasis and recurrence, drug resistance, and significant side effects from chemotherapy and radiation therapy. With the development and application of traditional Chinese medicine (TCM), it has been found that TCM and its active ingredients can effectively inhibit CRC cell proliferation, invasion, migration, and angiogenesis, and promote apoptosis and autophagy, thereby slowing the progression of CRC. This has become a key focus of CRC treatment research. Salvia Miltiorrhiza has multiple pharmacological effects, including activating blood circulation to dispel blood stasis, unlocking meridians to relieve pain, clearing heat to calm irritability, and cooling blood to reduce abscesses. It contains a variety of chemical components, including diterpenoids, phenolic acids, flavonoids, polysaccharides, nitrogen-containing compounds, steroids, and lactone compounds. This review summarized the molecular mechanisms of Salvia miltiorrhiza and its active ingredients in the treatment of CRC. It is found that these ingredients exert anti-CRC effects through various molecular mechanisms, including cell cycle arrest, promotion of apoptosis, inhibition of cell invasion and migration, induction of autophagy, suppression of tumor angiogenesis, and remodeling of the tumor microenvironment. The review aims to provide new insights for the drug development and clinical application of Salvia miltiorrhiza in CRC treatment.
2.Clinical application of "talus home technique" in pronation open ankle fractures.
Zhenhui SUN ; Jinxi HU ; Yanci ZHANG ; Dehang LIU ; Jianyi LEI ; Jianbo GUO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):542-549
OBJECTIVE:
To explore the safety and effectiveness of the "talus home technique (THT) " in the surgery of pronation open ankle fractures (POAF).
METHODS:
A retrospective analysis was conducted on 14 patients with POAF admitted between January 2023 and December 2023 who met the selection criteria. There were 7 males and 7 females; age ranged from 26 to 58 years, with a median age of 53 years. Injury causes included 9 cases of traffic accident injury, 3 cases of fall from hight injury, and 2 cases of crush injury. There were 5 cases of type Ⅱ, 6 cases of type ⅢA, and 3 cases of type ⅢB according to Gustilo classification; and 6 cases of pronation-abduction grade Ⅲ and 8 cases of pronation-external rotation grade Ⅳ according to Lauge-Hansen classification. Emergency first-stage debridement of the ankle joint was performed, followed by second-stage open reduction and internal fixation surgery. The THT was used through a limited incision on the lateral malleolus to restore the height of the lateral malleolus, rotational alignment, and anatomical relationship of the distal tibiofibular syndesmosis (DTFS). Wound healing was observed postoperatively. At 4 months postoperatively, weight-bearing anteroposterior, lateral, and mortise view X-ray films and CT scans of both ankles were reviewed to measure the medial clear space (MCS), tibiofibular clear space (TFCS), distal fibular tip to lateral process of talus (DFTL), and anterior/posterior syndesmosis distances of DTFS, and the quality of reduction of ankle fractures was evaluated. Ankle joint function was assessed using the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, and active dorsiflexion/plantar flexion range of motion were recorded at last follow-up.
RESULTS:
After second-stage internal fixation, 8 patients achieved wound healing by first intention, 1 case had skin edge necrosis, 2 cases had local skin necrosis, 1 case had extensive medial soft tissue defect, and 2 cases developed medial wound infection with sinus formation. All 14 patients were followed up 13-24 months (mean, 16.8 months). Postoperative X-ray films showed 1 case of delayed union of the lateral malleolus, which healed after bone grafting at 12 months; the remaining 13 cases achieved clinical union at 12-32 weeks (mean, 21.5 weeks). At 4 months postoperatively, X-ray films and CT examination showed no significant differences in MCS, TFCS, DFTL, and anterior/posterior syndesmosis distances of DTFS between the healthy and affected sides ( P>0.05), with no poor DTFS reduction. AOFAS ankle-hindfoot score ranged from 80 to 95, with an average of 87.7; ankle range of motion ranged from 10° to 25° (mean, 19.6°) in dorsiflexion and from 32° to 50° (mean, 41.2°) in plantar flexion.
CONCLUSION
THT is safe and effective in POAF surgery. It can restore lateral malleolar height and rotational alignment, enhance DTFS reduction quality, and obtain satisfactory short-term functional recovery of the ankle.
Humans
;
Male
;
Female
;
Middle Aged
;
Ankle Fractures/surgery*
;
Adult
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Pronation
;
Fractures, Open/surgery*
;
Talus/surgery*
;
Treatment Outcome
;
Debridement/methods*
;
Ankle Joint/surgery*
;
Open Fracture Reduction/methods*
3.Clinical characteristics of congenital and acquired middle ear cholesteatoma in children.
Jianbo SHAO ; Min CHEN ; Jinsheng HAO ; Yang YANG ; Wei LIU ; Bing LIU ; Ning MA ; Xiao ZHANG ; Xiaoxu WANG ; Jie ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(2):133-136
Objective:To retrospectively analyze the clinical features and surgical efficacy of congenital cholesteatoma (CC) and acquired cholesteatoma (AC) in children. Methods:Clinical data of 169 children with middle ear cholesteatoma were reviewed in the Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University from January 2010 to July 2020. The clinical characteristics, stages, surgical methods, and postoperative recurrence rates were analyzed and summarized. Results:The age distribution of enrolled children ranged from 2 to 14 years. The mean age of the CC group was (5.60±2.48) years compared with (6.45±2.48) years in the AC group, and the difference was statistically significant (P<0.05). Preoperative hearing in the CC group was (40.06±13.52) dB HL, which was better than in the AC group at (48.40±13.84) dB HL (P<0.05). The proportion of stage Ⅰ in the CC group was lower than that in the AC group according to EAONO/JOS staging (P<0.05). The recurrence rate after primary surgery was 19.23% (10/52) in the CC group compared with 36.29% (45/124) in the AC group (P<0.05). The mastoid retention rates after all operations were 28.85% (15/52) in the CC group and 5.65% (7/124) in the AC group (P<0.05). Conclusion:Compared with congenital cholesteatoma, acquired cholesteatoma in children is more aggressive and has more complications, higher postoperative recurrence rate, and less possibility of mastoid retention. Early clinical detection and treatment are required, and canal wall-down tympanoplasty should be considered in surgery.
Humans
;
Cholesteatoma, Middle Ear/congenital*
;
Child
;
Retrospective Studies
;
Child, Preschool
;
Adolescent
;
Male
;
Female
;
Recurrence
;
Cholesteatoma/congenital*
;
Tympanoplasty
;
Treatment Outcome
4.LncRNA EUDAL shapes tumor cell response to hypoxia-induced constitutive EGFR activation and promotes chemoresistance in oral cancer.
Shengkai CHEN ; Zhenlin DAI ; Jianbo SHI ; Mengyu RUI ; Zhiyuan ZHANG ; Qin XU
International Journal of Oral Science 2025;17(1):64-64
Hypoxia and aberrant activation of epidermal growth factor receptor (EGFR) are considered important features of various malignancies. However, whether hypoxia can directly trigger EGFR activation and its clinical implications remain unclear. In this study, we demonstrated that in oral cancer, a typical hypoxic tumor, hypoxia can induce chronic but constitutive phosphorylation of wild-type EGFR in the absence of ligands. Oral cancer cell lines exhibit different EGFR phosphorylation responses to hypoxia. In hypoxic HN4 and HN6 cells, ubiquitination-mediated endocytosis, lysosomal sorting, and degradation lead to low levels of EGFR phosphorylation. However, in CAL-27 and HN30 cells, a novel HIF-1α-induced long noncoding RNA (lncRNA), EUDAL, can compete with the E3 ligase/adaptor complex c-Cbl/Grb2 for binding to EGFR, stabilizing phosphorylated EGFR (pEGFR) and resulting in sustained activation of EGFR and its downstream STAT3/BNIP3 signaling. STAT3/BNIP3-mediated autophagy leads to antitumor drug resistance. A high EUDAL/EGFR/STAT3/autophagy pathway activation predicts poor response to chemotherapy in oral cancer patients. Collectively, hypoxia can induce noncanonical ligand-independent EGFR phosphorylation. High EUDAL expression facilitates sustained EGFR phosphorylation in hypoxic tumor cells and leads to autophagy-related drug resistance.
Humans
;
ErbB Receptors/metabolism*
;
Mouth Neoplasms/pathology*
;
RNA, Long Noncoding/genetics*
;
Drug Resistance, Neoplasm/genetics*
;
Cell Line, Tumor
;
Phosphorylation
;
Signal Transduction
;
STAT3 Transcription Factor/metabolism*
;
Cell Hypoxia
;
Autophagy
;
Proto-Oncogene Proteins c-cbl/metabolism*
5.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
6.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
7.Value of ultra-high-resolution photon-counting detector CT in improving neurovascular image quality
Guang YAO ; Jun LI ; Junli REN ; Xing LIU ; Lichen REN ; Yiran WANG ; Xiaolei ZHANG ; Jiawei LIU ; Jianbo GAO ; Yonggao ZHANG
Chinese Journal of Radiology 2025;59(12):1353-1360
Methods:This study was a cross-sectional study. A prospective cohort study enrolled 42 patients with clinically suspected acute cerebrovascular disease and those undergoing follow-up examinations after intracranial vascular stenting at the First Affiliated Hospital of Zhengzhou University from June 2024 to May 2025. All patients underwent UHR PCD-CT examinations of the head and neck. Reconstructions were performed based on raw data, yielding conventional standard resolution (SR group) reconstructions and UHR images reconstructed using four distinct convolution kernels (Hv40, Hv48, Hv56, Hv64) in separate groups (Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, Hv64 UHR group). Regions of interest were selected in the anterior cerebral artery, middle cerebral artery, posterior cerebral artery, posterior communicating artery, and anterior communicating artery. CT values and standard deviation (SD) values were measured for each artery, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Additionally, the sharpness of the vessel edges and the full-width-half-maximum (FWHM) of each artery were measured. One-way analysis of variance or the nonparametric Kruskal-Wallis test was used to compare the subjective and objective image quality metrics across the five groups. Pairwise comparisons were performed using the LSD test or Dunn method.Results:Statistically significant differences were observed in the overall comparison of vascular imaging SD, SNR, CNR, vascular edge sharpness, and FWHM among the SR group, Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, and Hv64 UHR group ( P<0.05). No statistically significant differences in CT values were found ( P>0.05). Pairwise comparisons revealed statistically significant differences between all groups ( P<0.05), except that no significant differences were observed in image SD, SNR, CNR, vascular edge sharpness, or FWHM between the Hv56 UHR and Hv64 UHR groups ( P>0.05). Conclusions:UHR PCD-CT provides better image quality for neurovascular imaging. For the display of small intracranial vessels, the Hv64 provides sharper vessel walls and better subjective image quality compared to the less sharp convolutional cores.Objective:To explore the value of ultra-high resolution (UHR) photon-counting detector CT (PCD-CT) to improve the quality of neurovascular images.
8.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
9.Toripalimab-related ureteritis:a case report
Jianbo FENG ; Yanyan ZHAO ; Huixian ZHANG ; Zhen LIU
Chinese Journal of Pharmacoepidemiology 2025;34(1):105-110
A 48-year-old woman was treated with toripalimab for triple negative breast cancer.She developed symptoms of pollakiuria and urinary urgency after 1st cycle of toripalimab,and was hospitalized for severe abdominal pain after 2nd circle of treatment,after symptomatic treatment,the condition improved.However,after the 3rd,4th,and 5th cycles of medication,the symptoms recurred.The symptoms did not reappear after discontinuing toripalimab.Therefore,ureteritis associated with immune checkpoint inhibitors(ICI)was considered based on case characteristics,urine routine,urine culture,ultrasound and CT findings.According to Naranjo's Assessment Scale,the association between toripalimab and ureteritis was considered"definite".The possibility of ureteritis associated with ICI should be considered if symptoms of urinary tract irritation occur during the use of toripalimab,and urine analysis,urine culture,and imaging examination should be conducted to detect such adverse reactions earlier.
10.Clinical Prediction Models Based on Traditional Methods and Machine Learning for Predicting First Stroke: Status and Prospects
Zijiao ZHANG ; Shunjing DING ; Di ZHAO ; Jun LIANG ; Jianbo LEI
Medical Journal of Peking Union Medical College Hospital 2025;16(2):292-299
Stroke ranks as the third leading cause of death and the fourth leading cause of disability worldwide. Its high disability rate and prolonged recovery period not only severely impact patients' quality of life but also impose a significant burden on families and society. Primary prevention is the cornerstone of stroke control, as early intervention on risk factors can effectively reduce its incidence. Therefore, the development of predictive models for first-ever stroke risk holds substantial clinical value. In recent years, advancements in big data and artificial intelligence technologies have opened new avenues for stroke risk prediction. This article reviews the current research status of traditional methods and machine learning models in predicting first-ever stroke risk and outlines future development trends from three perspectives: First, emphasis should be placed on technological innovation by incorporating advanced algorithms such as deep learning and large models to further enhance the accuracy of predictive models. Second, there is a need to diversify data types and optimize model architectures to construct more comprehensive and precise predictive models. Lastly, particular attention should be given to the clinical validation of models in real-world settings. This not only enhances the robustness and generalizability of the models but also promotes physicians' understanding of predictive models, which is crucial for their application and dissemination.

Result Analysis
Print
Save
E-mail