1.Eucommia ulmoides promotes alveolar bone formation in ovariectomized rats
Lin ZHENG ; Wenjun JIN ; Shanshan LUO ; Rui HUANG ; Jie WANG ; Yuting CHENG ; Zheqing AN ; Yue XIONG ; Zipeng GONG ; Jian LIAO
Chinese Journal of Tissue Engineering Research 2025;29(6):1159-1167
BACKGROUND:Eucommia ulmoides has a certain osteogenic effect,which can promote the proliferation and differentiation of osteoblasts.However,it is unclear whether Eucommia ulmoides has effects on alveolar bone formation and Wnt/β-Catenin signaling pathway. OBJECTIVE:To investigate the mechanism by which Eucommia ulmoides promotes alveolar bone formation in ovariectomized rats based on the Wnt/β-Catenin signaling pathway. METHODS:Sixty female Sprague-Dawley rats were selected and randomly divided into five groups:blank control group,sham-operation group,model group,low-dose group Eucommia ulmoides group,and high-dose Eucommia ulmoides group,with twelve rats in each group.Osteoporosis animal models were constructed by bilateral oophorectomy in the model group and the low-dose and high-dose Eucommia ulmoides groups.The sham-operation group underwent the same method to remove adipose tissue of equal mass around the bilateral ovaries.Three months after surgery,the low-and high-dose Eucommia ulmoides groups were given 2.1 g/kg/d and 4.2 g/kg/d Eucommia ulmoides by gavage,respectively.The sham-operation group and model group were given the same amount of physiological saline by gavage.After 12 weeks of drug intervention,the changes in alveolar bone mass of rats in each group were observed through Micro-CT;hematoxylin-eosin staining was used to observe the pathological structural changes of alveolar bone in rats;enzyme linked immunosorbent assay was used to detect the expression levels of alkaline phosphatase and osteocalcin in the serum of rats;western blot was used to detect the expression levels of β-Catenin and Frizzled9 receptor proteins in the alveolar bone of rats;and real-time fluorescence quantitative PCR was used to detect the expression of osteocalcin,Runt-related transcription factor 2(Runx2),alkaline phosphatase,β-catenin,and frizzled9 mRNAs in alveolar bone tissues of rats. RESULTS AND CONCLUSION:Compared with the blank control group,bone volume fraction,trabecular number,trabecular thickness,and bone mineral density were reduced in the model group(P<0.05),and trabecular separation was elevated(P<0.05).Pathological observation showed that the arrangement of trabeculae was disordered and irregular,the trabeculae were thinned or broken,and the marrow cavity was enlarged in the model group,with a significant reduction in bone volume;the level of alkaline phosphatase in the serum was increased(P<0.05),and the level of osteocalcin was decreased(P<0.05);mRNA expression of alkaline phosphatase,osteocalcin,Runx2,β-catenin,and frizzled9 were decreased(P<0.05);protein expression of β-Catenin and Frizzled9 was decreased(P<0.05).Compared with the model group,the low-and high-dose Eucommia ulmoides groups showed an increase in bone volume fraction,trabecular number,trabecular thickness,and bone mineral density(P<0.05)and a decrease in trabecular separation(P<0.05).In the low-and high-dose Eucommia ulmoides groups,bone trabeculae were slightly aligned and thickened,with a significant increase in bone mass.Compared with the model group,the serum level of alkaline phosphatase was reduced(P<0.05)and the serum level of osteocalcin was elevated(P<0.05)in the low-and high-dose Eucommia ulmoides groups.Compared with the model group,the mRNA expression of alkaline phosphatase,osteocalcin,Runx2,β-catenin,and frizzled9 were increased in the low-and high-dose Eucommia ulmoides groups(P<0.05).Compared with the model group,the protein expression of Frizzled9 was increased in the low-dose Eucommia ulmoides group(P<0.05),while the protein expression of β-Catenin and Frizzled9 was increased in the high-dose Eucommia ulmoides group(P<0.05).Compared with the low-dose Eucommia ulmoides group,the high-dose Eucommia ulmoides group had a more significant improvement in the above indexes.To conclude,Eucommia ulmoides can effectively promote the alveolar bone formation,and its mechanism of action might be related to the activation of the Wnt/β-catenin signaling pathway.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Hypertension and NAFLD risk: Insights from the NHANES 2017-2018 and Mendelian randomization analyses
Mengqin YUAN ; Jian HE ; Xue HU ; Lichao YAO ; Ping CHEN ; Zheng WANG ; Pingji LIU ; Zhiyu XIONG ; Yingan JIANG ; Lanjuan LI
Chinese Medical Journal 2024;137(4):457-464
Background::Hypertension and non-alcoholic fatty liver disease (NAFLD) share several pathophysiologic risk factors, and the exact relationship between the two remains unclear. Our study aims to provide evidence concerning the relationship between hypertension and NAFLD by analyzing data from the National Health and Nutrition Examination Survey (NHANES) 2017-2018 and Mendelian randomization (MR) analyses.Methods::Weighted multivariable-adjusted logistic regression was applied to assess the relationship between hypertension and NAFLD risk by using data from the NHANES 2017-2018. Subsequently, a two-sample MR study was performed using the genome-wide association study (GWAS) summary statistics to identify the causal association between hypertension, systolic blood pressure (SBP), diastolic blood pressure (DBP), and NAFLD. The primary inverse variance weighted (IVW) and other supplementary MR approaches were conducted to verify the causal association between hypertension and NAFLD. Sensitivity analyses were adopted to confirm the robustness of the results.Results::A total of 3144 participants were enrolled for our observational study in NHANES. Weighted multivariable-adjusted logistic regression analysis suggested that hypertension was positively related to NAFLD risk (odds ratio [OR] = 1.677; 95% confidence interval [CI], 1.159-2.423). SBP ≥130 mmHg and DBP ≥80 mmHg were also significantly positively correlated with NAFLD. Moreover, hypertension was independently connected with liver steatosis ( β = 7.836 [95% CI, 2.334-13.338]). The results of MR analysis also supported a causal association between hypertension (OR = 7.203 [95% CI, 2.297-22.587]) and NAFLD. Similar results were observed for the causal exploration between SBP (OR = 1.024 [95% CI, 1.003-1.046]), DBP (OR = 1.047 [95% CI, 1.005-1.090]), and NAFLD. The sensitive analysis further confirmed the robustness and reliability of these findings (all P >0.05). Conclusion::Hypertension was associated with an increased risk of NAFLD.
8.FLASH Interacts with Promyelocytic Leukemia Protein Ⅳ(PML Ⅳ)and Enhances the SUMOylation of p53
Meng-Ni WANG ; Zhen-Zhen XIONG ; Zhi-Ying WANG ; Jian-Hua WU ; Xiao-Zhong SHI
Chinese Journal of Biochemistry and Molecular Biology 2024;40(10):1426-1440
As a unique gene in the genome,FLASH(FADD-like interleukin-1β-converting enzyme asso-ciated huge protein)/CASP8AP2 is involved in multiple cellular processes,including apoptosis,histone gene pre-mRNA processing,transcriptional regulation,and cell cycle progression.Clinical studies have shown that FLASH is a valuable prognostic marker for acute lymphoblastic leukemia,and a crucial factor for the survival of various cancer cells.Therefore,in-depth research into the function of FLASH may offer new perspectives for the treatment of related diseases.Our previous research identified FLASH as a bind-ing partner of p53,demonstrating that FLASH enhances the transcriptional activity of p53.Here we fur-ther investigate the molecular mechanisms of the interaction between FLASH and p53,revealing that the p53-K386R mutation(SUMOylation residue)attenuated its interaction with FLASH(aa 51-200)and FLASH-SIM(SUMO-interacting motif)(aa 1 534-1 806)significantly.However,SUMO can bind to FLASH-SIM directly,instead of FLASH(aa 51-200).Subsequent research shows that overexpression of FLASH in cells enhances global SUMO1 conjugation and p53-SUMO1 conjugation,therefore providing a plausible explanation for the underlying mechanism of FLASH enhancing the transcriptional activity of p53.Since promyelocytic leukemia protein nuclear body(PML NB)serves as subcellular reactors for SUMO conjugation within the cell,and the PML Ⅳ isoform can specifically enhance the SUMO modifica-tion of p53,we have investigated the interaction between FLASH and PML Ⅳ,and elucidated the struc-tural basis of their interaction:both FLASH-N3A(501-802)and FLASH-C2(1 807-1 981)bind to PML Ⅳ(aa 228-633).Further investigations reveal that they can synergistically enhance global SUMO1 modification as well as SUMO1 modification of p53.The interaction between FLASH and tumor suppres-sors p53 or PML Ⅳ enriches our understanding of its function and reveals the potential mechanism of FLASH in tumor development,therefore offering novel insights into cancer diagnosis and treatment.
9.Detection of avian influenza virus by RAA-CRISPR/Cas13a
Xiangyun LE ; Zhihang FENG ; Yanli FAN ; Qiang ZHANG ; Yicun CAI ; Wei XIONG ; Xiang WANG ; Qingli DONG ; Jian LI ; Junxin XUE ; Yan WANG
Chinese Journal of Veterinary Science 2024;44(10):2153-2158,2171
An innovative on-site real-time avian influenza virus(AIV)detection method was estab-lished by integratingrecombinase-aided amplification(RAA)with the clustered regularly inter-spaced short palindromic repeats(CRISPR)/CRISPR-associated protein(Cas)system.After analy-zing 120 sequences of the M gene of avian influenza viruses of different subtypes publicly available on NCBI,the RAA primers and crRNA were designed based on the identified highly conserved segment and used for RAA nucleic acid amplification.After the amplified products were transferred to a CRISPR/Cas13a detection system,the fluorescence values were monitored throughout the re-action process to indicate the results.The sensitivity and specificity of the RAA-CRISPR/Cas13a method were validated using gradient dilutions(106-100 copies/μL)of positive plasmids and sev-en other avian viruses.Fifty clinical samples were tested using this method and compared with the national standard fluorescence RT-PCR method.The results indicated that the detection limit for RAA-CRISPR/Cas13a method was 102 copies/μL,a two-fold improvement over the standard RAA.Specificity assay showed the established method only detected AIV with no cross-reactivity with other seven avian viruses.Compared to the national standard fluorescence RT-PCR method,this method exhibited 100%specificity,95.24%accuracy,and 98.00%consistency in detection of clinical samples.In conclusion,a universal and rapid RAA-CRISPR/Cas13a for detection of AIV was established with the capacity of achieving detection within 60 minutes at 37 ℃,which provides a rapid,sensitive,and specific on-site detection method for AIV.
10.Evaluation on clinical efficacy of three-dimensional reconstruction guided uniportal fluorescence thoracoscopic subsegmentectomy for the pulmonary nodules
Bicheng ZHAN ; Jian LIU ; Jian CHEN ; Yongzhi LIU ; Kunliang GUO ; Xiao WANG ; Yanzheng XIONG ; Yong TANG ; Mingbo GU
Chinese Journal of Thoracic and Cardiovascular Surgery 2024;40(11):641-646
Objective:To analyze the clinical efficacy of three-dimensional(3D) reconstruction guided uniportal fluorescence thoracoscopic subsegmentectomy for the pulmonary nodules.Methods:We retrospectively analyzed 50 patients with nodules who underwent uniportal fluorescence thoracoscopic subsegmentectomy from December 2021 to February 2024. All patients underwent thin-slice CT scanning and 3D reconstruction preoperatively. 12 patients were given CT-guided hookwire localization preoperatively.The intersegmental plane was identified by fluorescence method.Results:One patient was converted to right upper lobectomy due to no lesion found in S1b. The mean blood loss was(23.4±16.5)ml and the mean operative time was(126.5±38.5)min. The mean duration of postoperative drainage was(2.6±0.8)days. Mean postoperative hospitalization was(4.8±1.8)days. There were 2 cases with postoperative pulmonary infections, including one with encapsulated pleural effusion. There was no air leakage over 3 days, and no death within 30 days after surgery.Conclusion:3D reconstruction guided uniportal fluorescence thoracoscopic subsegmentectomy is a safe and feasible technique for resection of pulmonary nodules in lung subsegments, and surgical indications must be strictly controlled.

Result Analysis
Print
Save
E-mail