1.Synthesis and Identification of Saturated Arsenic-containing Hydrocarbons
Jia-Jia CHEN ; Ying-Xiong ZHONG ; Xin-Huang KANG ; Chun-Mei DENG ; Bing-Bing SONG ; Xiao-Fei LIU ; Zhuo WANG ; Rui LI ; Jian-Ping CHEN ; Xue-Jing JIA ; Sai-Yi ZHONG
Chinese Journal of Analytical Chemistry 2025;53(3):472-480
Arsenic is a semi-metal,and lipid-soluble arsenic compounds are one of the widespread forms in the environment and food chain,but there is a lack of standards for lipid-soluble arsenic compounds,which is one of the bottlenecks in the current analytical detection and toxicological studies of organic arsenic.In this study,four saturated arsenic-containing hydrocarbons,AsHC 318,AsHC 332,AsHC 346,and AsHC 374(The number is relative molecular mass),were successfully synthesized in three steps by using dimethylarsinic acid,potassium iodide,sodium hydroxide,and four brominated alkanes(1-Bromotetradecane,1-bromopentadecane,1-bromohexadecane,and 1-bromooctadecane)as raw materials.The structures of these four saturated arsenic-containing hydrocarbons were characterized by proton nuclear magnetic resonance(1H NMR)spectroscopy,13C nuclear magnetic resonance(13C NMR)spectroscopy,and high-resolution mass spectrometry(HR-MS).The yields of the method were 8%-10%,and the synthesized compounds could be used in subsequent toxicity evaluation experiments to assess the toxic effects and mechanisms of action of arsenic-containing hydrocarbons.This study provided an effective method for synthesis of arsenic-containing hydrocarbons,enriching the synthesis methods of arsenic-containing hydrocarbons,and provided raw materials for the subsequent toxicological studies of arsenic-containing hydrocarbons.
2.Immune function regulation and tumor-suppressive effects of Shenqi Erpi Granules on S_(180) tumor-bearing mice.
Xiong-Wei ZHANG ; Yan-Ning JIANG ; Hu QI ; Bin LI ; Yuan-Lin GAO ; Ze-Yang ZHANG ; Jian-An FENG ; Xi LI ; Nan ZENG
China Journal of Chinese Materia Medica 2025;50(13):3753-3764
This study aims to establish the S_(180) tumor-bearing mice model, and to investigate the influence of Shenqi Erpi Granules(SQEPG) on immune function, as well as the drug's tumor-suppressive effect and mechanism. SPF grade KM mice(half male and half female) were randomly divided into 6 groups: a control group, a model group, a cyclophosphamide group(50 mg·kg~(-1)), as well as SQEPG groups in low-, medium-, and high-dose(5.25, 10.5, 21 g·kg~(-1)). The control group and the model group were given distilled water, and the other 4 groups were given the corresponding drugs by gavage. The administration continued for 10 days before the mice were sacrificed. The antitumor and immune regulation effects of SQEPG were evaluated. The effect of SQEPG on delayed type hypersensitivity reaction(DTH), carbon clearance index, and serum hemolysin antibody level was observed to reflect the effect on the immune function of tumor-bearing mice. Tumor weight was recorded to calculate the tumor suppression rate and the immune organ index. Hematoxylin-eosin(HE) staining was used to detect morphological changes in tumor tissues. Flow cytometry was employed to detect the percentage of CD4~+ and CD8~+ T-cells in the spleen tissues and the tumor tissue apoptosis levels. Immunohistochemistry was conducted to detect the KI67 protein expression level of tumor tissues. ELISA resorted to the detection of the following expression levels in tumor tissues: tumor necrosis factor-α(TNF-α), interleukin-2(IL-2), interferon-γ(IFN-γ). Western blot was performed to detect the expression levels of caspase-3, B-cell lymphoma-2(Bcl-2), Bcl-2-associated X protein(Bax), cyclin-dependent kinases 4(CDK4), G_1/S-specific cyclin D1(cyclin D1), and vascular endothelial growth factor A(VEGFA). The results showed that, compared with the model group, the SQEPG could increase the swelling of the auricle of the tumor-bearing mice; significantly increase the phagocytic index of carbon granule contour(P<0.05 or P<0.01), and the middle dose of SQEPG could significantly increase the antibody level of hemolysin(P<0.05); different doses of SQEPG significantly inhibit the growth of the tumor, and decrease the mass of the tumor tissues(P<0.05 or P<0.01); the low dose of SQEPG significantly decreased spleen index(P<0.05), low and high doses of SQEPG increased thymus index, while medium doses of SQEPG decreased thymus index. High doses of SQEPG significantly elevated the levels of CD4~+ and CD8~+ T-cells in the spleens of the homozygous mice(P<0.01 or P<0.001), and increased the apoptosis rate of the cells of the tumor tissues(P<0.05); Meanwhile, high-dose SQEPG elevated the levels of immunity factors such as IL-2, IFN-γ and TNF-α in the serum of tumor-bearing mice(P<0.01); medium-and high-dose SQEPG significantly lowered the rate of positive expression of KI67 protein in tumor tissues(P<0.01). Compared with the model group, high-dose SQEPG significantly up-regulated the expression of caspase-3 and Bax proteins in tumor tissues(P<0.05), and significantly down-regulated the expression of CDK4, cyclin D1, and VEGFA proteins(P<0.05 or P<0.01). In conclusion, SQEPG has the effect of improving immune function and inhibiting tumor growth in tumor-bearing mice. Its mechanism of tumor-suppressive effects may be related to apoptosis promotion, cell cycle progression block, and tumor cell proliferation inhibition.
Animals
;
Mice
;
Drugs, Chinese Herbal/pharmacology*
;
Male
;
Female
;
Apoptosis/drug effects*
;
Sarcoma 180/genetics*
;
Humans
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Strategy for cysteine-targeting covalent inhibitors screening using in-house database based LC-MS/MS and drug repurposing.
Xiaolan HU ; Jian-Lin WU ; Quan HE ; Zhi-Qi XIONG ; Na LI
Journal of Pharmaceutical Analysis 2025;15(3):101045-101045
Targeted covalent inhibitors, primarily targeting cysteine residues, have attracted great attention as potential drug candidates due to good potency and prolonged duration of action. However, their discovery is challenging. In this research, a database-assisted liquid chromatography-tandem mass spectrometry (LC-MS/MS) strategy was developed to quickly discover potential cysteine-targeting compounds. First, compounds with potential reactive groups were selected and incubated with N-acetyl-cysteine in microsomes. And the precursor ions of possible cysteine-adducts were predicted based on covalent binding mechanisms to establish in-house database. Second, substrate-independent product ions produced from N-acetyl-cysteine moiety were selected. Third, multiple reaction monitoring scan was conducted to achieve sensitive screening for cysteine-targeting compounds. This strategy showed broad applicability, and covalent compounds with diverse structures were screened out, offering structural resources for covalent inhibitors development. Moreover, the screened compounds, norketamine and hydroxynorketamine, could modify synaptic transmission-related proteins in vivo, indicating their potential as covalent inhibitors. This experimental-based screening strategy provides a quick and reliable guidance for the design and discovery of covalent inhibitors.
10.Spatio-Temporal Pattern and Socio-economic Influencing Factors of Tuberculosis Incidence in Guangdong Province: A Bayesian Spatiotemporal Analysis.
Hui Zhong WU ; Xing LI ; Jia Wen WANG ; Rong Hua JIAN ; Jian Xiong HU ; Yi Jun HU ; Yi Ting XU ; Jianpeng XIAO ; Ai Qiong JIN ; Liang CHEN
Biomedical and Environmental Sciences 2025;38(7):819-828
OBJECTIVE:
To investigate the spatiotemporal patterns and socioeconomic factors influencing the incidence of tuberculosis (TB) in the Guangdong Province between 2010 and 2019.
METHOD:
Spatial and temporal variations in TB incidence were mapped using heat maps and hierarchical clustering. Socioenvironmental influencing factors were evaluated using a Bayesian spatiotemporal conditional autoregressive (ST-CAR) model.
RESULTS:
Annual incidence of TB in Guangdong decreased from 91.85/100,000 in 2010 to 53.06/100,000 in 2019. Spatial hotspots were found in northeastern Guangdong, particularly in Heyuan, Shanwei, and Shantou, while Shenzhen, Dongguan, and Foshan had the lowest rates in the Pearl River Delta. The ST-CAR model showed that the TB risk was lower with higher per capita Gross Domestic Product (GDP) [Relative Risk ( RR), 0.91; 95% Confidence Interval ( CI): 0.86-0.98], more the ratio of licensed physicians and physician ( RR, 0.94; 95% CI: 0.90-0.98), and higher per capita public expenditure ( RR, 0.94; 95% CI: 0.90-0.97), with a marginal effect of population density ( RR, 0.86; 95% CI: 0.86-1.00).
CONCLUSION
The incidence of TB in Guangdong varies spatially and temporally. Areas with poor economic conditions and insufficient healthcare resources are at an increased risk of TB infection. Strategies focusing on equitable health resource distribution and economic development are the key to TB control.
Humans
;
China/epidemiology*
;
Incidence
;
Bayes Theorem
;
Spatio-Temporal Analysis
;
Tuberculosis/epidemiology*
;
Socioeconomic Factors

Result Analysis
Print
Save
E-mail