1.Current awareness and optimization recommendations regarding the pneumonia with unknown etiology surveillance system among healthcare professionals in Shanghai
Qiwen FANG ; Chenyan JIANG ; Xin CHEN ; Huanyu WU ; Bihong JIN ; Xiaohuan GONG ; Shenghua MAO ; Qi QIU ; Ruobing HAN ; Huilin SHI ; Wenbin DONG ; Xin HU ; Jian CHEN ; Yaxu ZHENG
Shanghai Journal of Preventive Medicine 2026;38(6):482-487
ObjectiveTo investigate the current awareness and optimization recommendations on pneumonia with unknown etiology (PUE) surveillance among Shanghai healthcare professionals, and to provide evidence for the improvement of the surveillance system. MethodsIn December 2024, healthcare professional participants from diverse medical and health institutions were randomly selected within each stratum using a stratified cluster sampling method in all 16 districts of Shanghai for questionnaire surveys on their knowledge and suggestions for optimization of the PUE surveillance system. Descriptive statistics analyses, multivariate logistic regressions, and content analyses were used for data analyses. ResultsA total of 385 survey subjects were involved in the study, including 119 professional staffs from disease prevention and control centers and 266 from medical institutions. Those who understood the case definition for PUE correctly accounted for 67.01% (258/385). Multivariate regression model analyses showed that female gender (aOR=2.22, 95%CI: 1.36‒3.66), professionals from disease control institutions (aOR=2.02, 95%CI: 1.12‒3.72), and those who self-assessed as being familiar with the monitoring system (aOR=2.18, 95%CI:1.23‒3.89) had better understanding of the definition. Overall, 89.61% (345/385) of the survey subjects acknowledged the necessity of the surveillance system. Small number of cases meeting the case definition (54.46%, 214/379), insufficient diagnostic awareness (39.84%, 151/379), and lack of incentives for case reporting (29.29%, 111/379) were major problems for the current surveillance system, with variations observed across different types of institutions. Suggested segments for optimizing the surveillance system included monitoring purpose, case definition, form of monitoring and reporting procedure, organization mechanism, and epidemiological investigation and response. ConclusionThe necessity of PUE surveillance is commonly recognized among healthcare workers. However, the existing system falls short in terms of mastery of case definition and overall surveillance adaptability. There is an urgent need for optimization and improvement to enhance the capacity for preventing and controlling emerging and sudden respiratory infectious diseases.
2.Comparative analysis of medium-to-long-term effects of Ceramage? polymer ceramic composite resoin onlay and CAD/CAM fabricated all-ceramic onlays in restoring endodontically treated posterior teeth
Shuya SHI ; Jian ZHAO ; Xin LI ; Hongqiang YU ; Yu DONG
Journal of Practical Stomatology 2025;41(6):829-833
Objective:To compare the midium-to-long-term clinical outcomes of Ceramage? polymer ceramic composite resoin on-lay and CAD/CAM fabricated all-ceramic onlays in the restoration of endodontically treated posterior teeth.Methods:A total of 75 patients with 92 endodontically treated posterior teeth exhibiting class Ⅱ defects were included and randomly divided into two groups:the Ceramage? composite resin group(48 teeth)and the CAD/CAM fabricated all-ceramic group(44 teeth).The respective restora-tions were performed,and patients were followed up for 24 months.Clinical outcomes of the restorations and periodontal conditions were evaluated using the modified USPHS criteria,and patient satisfaction was assessed.Results:After 24 months of follow-up,the Ceramage? composite resin group showed higher rates of secondary caries,marginal discrepancy,and marginal discoloration,as well as higher plaque index,gingival index,and sulcus bleeding index compared to the CAD/CAM fabricated all-ceramic group.Howev-er,the Ceramage? group exhibited lower rates of restoration wear and fracture(P<0.05).Patient satisfaction was similar between the two groups(P>0.05).Conclusion:Both Ceramage? polymer ceramic composite resoin onlay and CAD/CAM fabricated all-ce-ramic onlays achieved favorable mid-to-long-term clinical outcomes.The choice of restoration method should comprehensively con-sider the patient's oral condition and restorative needs.
3.Anticoagulation protocols during catheter ablation for atrial fibrillation in the elderly
Shixing LI ; Jian LI ; Chuang ZHANG ; Tong ZHAO ; Qian XIN ; Xiangmin SHI
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2025;27(1):9-12
Objective To summarize the results of different perioperative anticoagulation protocols for elderly patients with atrial fibrillation(AF)undergoing catheter radiofrequency ablation in our center.Methods A total of 197 elderly AF patients undergoing catheter radiofrequency ablation by a single operator in the First and Sixth Medical Centers of Chinese PLA General Hospital from January 2021 to December 2023 were retrospectively recruited,and the results of relevant exami-nations were collected.Based on the use of different direct oral anticoagulants,they were divided into dabigatran(n=125)and rivaroxaban(n=72)groups.During the procedure,the appropriate dose of unfractionated heparin was administered according to the initial activated clotting time(ACT)with a self-made formula.The time and rate of ACT were recorded,and perioperative ad-verse reactions such as bleeding and thrombosis were observed.Results There were no statistical differences between the two groups in baseline data,including age,gender,BMI,medical history,CHA2DS2-VASc score,HAS-BLED score,and left atrial anteroposterior diameter(P>0.05).The baseline ACT value was obviously shorter(149.73+23.52 s vs 157.91±24.58 s,P=0.032),the initial heparin dose was significantly higher(0.71±0.12 mg/kg vs 0.65±0.13 mg/kg,P=0.031),and the rate of ACT reaching the target within 15 min was notably lower(60%vs 74%,P<0.05)in the dabigatran group than the rivaroxaban group.But no significant difference was observed in the rate of ACT reaching the target in 45 min after additional heparin administration according to the formula(86%vs 88%,P>0.05).The dabigatran group used higher dose of heparin during the procedure than the rivaroxaban group(0.99±0.30 mg/kg vs 0.85±0.31 mg/kg,P=0.009).Peri-cardial effusion was observed in one patient of the rivaroxaban group,and hematoma at the site of femoral vein puncture was seen in one patients of the dabigatran group in 1 d after procedure,which was treated surgically.No other severe complications occurred.Conclusion For elderly pa-tients with AF undergoing catheter ablation therapy,continuous perioperative anticoagulation and individualized application of unfractionated heparin based on initial ACT value can rapidly achieve ACT targets and improve anticoagulation efficacy.
4.Comparative analysis of medium-to-long-term effects of Ceramage? polymer ceramic composite resoin onlay and CAD/CAM fabricated all-ceramic onlays in restoring endodontically treated posterior teeth
Shuya SHI ; Jian ZHAO ; Xin LI ; Hongqiang YU ; Yu DONG
Journal of Practical Stomatology 2025;41(6):829-833
Objective:To compare the midium-to-long-term clinical outcomes of Ceramage? polymer ceramic composite resoin on-lay and CAD/CAM fabricated all-ceramic onlays in the restoration of endodontically treated posterior teeth.Methods:A total of 75 patients with 92 endodontically treated posterior teeth exhibiting class Ⅱ defects were included and randomly divided into two groups:the Ceramage? composite resin group(48 teeth)and the CAD/CAM fabricated all-ceramic group(44 teeth).The respective restora-tions were performed,and patients were followed up for 24 months.Clinical outcomes of the restorations and periodontal conditions were evaluated using the modified USPHS criteria,and patient satisfaction was assessed.Results:After 24 months of follow-up,the Ceramage? composite resin group showed higher rates of secondary caries,marginal discrepancy,and marginal discoloration,as well as higher plaque index,gingival index,and sulcus bleeding index compared to the CAD/CAM fabricated all-ceramic group.Howev-er,the Ceramage? group exhibited lower rates of restoration wear and fracture(P<0.05).Patient satisfaction was similar between the two groups(P>0.05).Conclusion:Both Ceramage? polymer ceramic composite resoin onlay and CAD/CAM fabricated all-ce-ramic onlays achieved favorable mid-to-long-term clinical outcomes.The choice of restoration method should comprehensively con-sider the patient's oral condition and restorative needs.
5.A longitudinal case study on the dynamic evolution of rural family doctor contract service mode
Ya-yan TIAN ; Ting-hui LIAN ; Xin-yu SHI ; Jian-tao LI
Chinese Journal of Health Policy 2025;18(6):51-57
Objective:To explore the development context and evolution mechanism of family doctor contract service mode in rural areas,and provide reference for relevant departments to continuously optimize the family doctor contract service policy.Methods:Based on the principle of theoretical sampling,J City in S Province,which is listed as one of the national primary health comprehensive pilot areas,was selected as the case study object,and the data were collected through interviews and literature review,and then grounded and coded with NVivo11 software.Results:74 initial concepts,24 sub categories and 9 main categories were sorted out,and the core categories were formed through selective coding.The signing service of family doctors in rural areas has gone through three stages:individual signing of rural doctors,team signing and team signing under the county medical community.Its evolution conditions have gone through the formalization of signing,service capability and efficiency synergy in turn.The three elements of the system adaptation action successively presents differential execution under the system de embedding,collaborative block under the structure embedding and collaborative execution under the system coupling,so as to gradually realize the system coupling from responsibility construction to ability improvement,and then to responsibility,ability and interest.Conclusion:the evolution mechanism of the contracted service mode of family doctors in rural areas reflects the dynamic adaptation under the conditions of political situation,social situation and policy situation,and gradually realizes the closed-loop of the three elements of responsibility,ability and interest based on the differentiation of the three elements of the system.
6.Anticoagulation protocols during catheter ablation for atrial fibrillation in the elderly
Shixing LI ; Jian LI ; Chuang ZHANG ; Tong ZHAO ; Qian XIN ; Xiangmin SHI
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2025;27(1):9-12
Objective To summarize the results of different perioperative anticoagulation protocols for elderly patients with atrial fibrillation(AF)undergoing catheter radiofrequency ablation in our center.Methods A total of 197 elderly AF patients undergoing catheter radiofrequency ablation by a single operator in the First and Sixth Medical Centers of Chinese PLA General Hospital from January 2021 to December 2023 were retrospectively recruited,and the results of relevant exami-nations were collected.Based on the use of different direct oral anticoagulants,they were divided into dabigatran(n=125)and rivaroxaban(n=72)groups.During the procedure,the appropriate dose of unfractionated heparin was administered according to the initial activated clotting time(ACT)with a self-made formula.The time and rate of ACT were recorded,and perioperative ad-verse reactions such as bleeding and thrombosis were observed.Results There were no statistical differences between the two groups in baseline data,including age,gender,BMI,medical history,CHA2DS2-VASc score,HAS-BLED score,and left atrial anteroposterior diameter(P>0.05).The baseline ACT value was obviously shorter(149.73+23.52 s vs 157.91±24.58 s,P=0.032),the initial heparin dose was significantly higher(0.71±0.12 mg/kg vs 0.65±0.13 mg/kg,P=0.031),and the rate of ACT reaching the target within 15 min was notably lower(60%vs 74%,P<0.05)in the dabigatran group than the rivaroxaban group.But no significant difference was observed in the rate of ACT reaching the target in 45 min after additional heparin administration according to the formula(86%vs 88%,P>0.05).The dabigatran group used higher dose of heparin during the procedure than the rivaroxaban group(0.99±0.30 mg/kg vs 0.85±0.31 mg/kg,P=0.009).Peri-cardial effusion was observed in one patient of the rivaroxaban group,and hematoma at the site of femoral vein puncture was seen in one patients of the dabigatran group in 1 d after procedure,which was treated surgically.No other severe complications occurred.Conclusion For elderly pa-tients with AF undergoing catheter ablation therapy,continuous perioperative anticoagulation and individualized application of unfractionated heparin based on initial ACT value can rapidly achieve ACT targets and improve anticoagulation efficacy.
7.Processing technology of calcined Magnetitum based on concept of QbD and its XRD characteristic spectra.
De-Wen ZENG ; Jing-Wei ZHOU ; Tian-Xing HE ; Yu-Mei CHEN ; Huan-Huan XU ; Jian FENG ; Yue YANG ; Xin CHEN ; Jia-Liang ZOU ; Lin CHEN ; Hong-Ping CHEN ; Shi-Lin CHEN ; Yuan HU ; You-Ping LIU
China Journal of Chinese Materia Medica 2025;50(9):2391-2403
Guided by the concept of quality by design(QbD), this study optimizes the calcination and quenching process of calcined Magnetitum and establishes the XRD characteristic spectra of calcined Magnetitum, providing a scientific basis for the formulation of quality standards. Based on the processing methods and quality requirements of Magnetitum in the Chinese Pharmacopoeia, the critical process parameters(CPPs) identified were calcination temperature, calcination time, particle size, laying thickness, and the number of vinegar quenching cycles. The critical quality attributes(CQAs) included Fe mass fraction, Fe~(2+) dissolution, and surface color. The weight coefficients were determined by combining Analytic Hierarchy Process(AHP) and the criteria importance though intercrieria correlation(CRITIC) method, and the calcination process was optimized using orthogonal experimentation. Surface color was selected as a CQA, and based on the principle of color value, the surface color of calcined Magnetitum was objectively quantified. The vinegar quenching process was then optimized to determine the best processing conditions. X-ray diffraction(XRD) was used to establish the characteristic spectra of calcined Magnetitum, and methods such as similarity evaluation, cluster analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) were used to evaluate the quality of the spectra. The optimized calcined Magnetitum preparation process was found to be calcination at 750 ℃ for 1 h, with a laying thickness of 4 cm, a particle size of 0.4-0.8 cm, and one vinegar quenching cycle(Magnetitum-vinegar ratio 10∶3), which was stable and feasible. The XRD characteristic spectra analysis method, featuring 9 common peaks as fingerprint information, was established. The average correlation coefficient ranged from 0.839 5-0.988 1, and the average angle cosine ranged from 0.914 4 to 0.995 6, indicating good similarity. Cluster analysis results showed that Magnetitum and calcined Magnetitum could be grouped together, with similar compositions. OPLS-DA discriminant analysis identified three key characteristic peaks, with Fe_2O_3 being the distinguishing component between the two. The final optimized processing method is stable and feasible, and the XRD characteristic spectra of calcined Magnetitum was initially established, providing a reference for subsequent quality control and the formulation of quality standards for calcined Magnetitum.
X-Ray Diffraction/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Particle Size
8.Quality evaluation of Bidentis Herba based on HPLC fingerprint, multi-component content determination, and chemometrics.
Guo-Li SHI ; Xin-Feng WANG ; Wei-Qun LI ; Jian-Wei FAN ; Yong-Xia GUAN
China Journal of Chinese Materia Medica 2025;50(14):3944-3950
This study established the HPLC fingerprints and a multi-component content determination method for Bidens pilosa var. radiata and B. pilosa and conducted comprehensive evaluation by integrating fingerprint similarity comparison, cluster analysis(CA), and principal component analysis(PCA), aiming to provide a reference for the establishment of quality standards for Bidentis Herba. HPLC was launched on an Agilent Poroshell 120 EC-C_(18) chromatographic column(4.6 mm×250 mm, 4 μm) by gradient elution with a mobile phase of 0.1% aqueous phosphoric acid-acetonitrile at a flow rate of 0.7 mL·min~(-1), detection wavelength of 270 nm, column temperature of 25 ℃, and an injection volume of 5 μL. The fingerprint similarity of 20 batches of Bidentis Herba ranged from 0.775 to 0.979. A total of 20 common peaks were identified, and seven components were confirmed through comparison with reference substances: neochlorogenic acid, chlorogenic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, rutin, and hyperoside. These seven components exhibited good linearity within the ranges of 3.4-67.4, 33.0-660.3, 26.6-531.2, 3.5-70.5, 6.2-124.9, 2.4-48.3, and 4.6-91.5 μg·mL~(-1), respectively, with correlation coefficients(r) greater than 0.999. The average recovery rates ranged from 96.47% to 104.6%. CA and PCA classified the 20 batches of Bidentis Herba into two categories. PCA yielded two principal components, with a cumulative variance contribution rate of 80.557%. The established HPLC fingerprints and multi-component content determination method are simple and accurate, providing a scientific basis for the quality control and quality standard formulation of Bidentis Herba.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Chemometrics/methods*
;
Bidens/chemistry*
;
Principal Component Analysis
9.Pharmaceutical process omics and its applications and prospects in drug quality control.
Yu-Ting LU ; Jia-Yu YANG ; Ying-Ting SHI ; Xin-Yuan XIE ; Jian-Yang PAN ; Hai-Bin QU
China Journal of Chinese Materia Medica 2025;50(13):3628-3634
The quality of drugs is a crucial premise for ensuring the safety and effectiveness of clinical medication, while quality control during the pharmaceutical process directly affects the quality and consistency of the final product formulation. However, there is a lack of a comprehensive and scientific system for assessing and optimizing the quality control level during the manufacturing process in the field of drug quality control. Therefore, this study proposed the concept of "pharmaceutical process omics", clarified its advantages in guiding drug production, and explored in depth the research approaches, diverse analytical techniques, and broad range of applications in drug quality control. In addition, this study anticipated the broad application prospects of pharmaceutical process omics in the field of drug quality control, aiming to provide a scientific basis for the development of pharmaceutical process quality control standards.
Quality Control
;
Humans
;
Drugs, Chinese Herbal/chemistry*
10.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.

Result Analysis
Print
Save
E-mail