1.The Association of Iodixanol With Renal and Cardiovascular Safety in Patients With ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention:A Prospective Cohort Study
Zhaoping LIU ; Jian AN ; Aijie HOU ; Yanqin REN ; Lei QIN ; Xiaojie CHEN ; Guozhen HAO ; Xi SU ; Ping YANG ; Guidong SHEN ; Shenghuang WANG ; In-ho CHAE ; Yong HUO
Journal of Cardiovascular Intervention 2026;5(1):38-48
Background:
This study was performed to characterize the incidence, costs, and risk factors associated with renal and cardiovascular adverse outcomes following primary percutaneous coronary intervention (pPCI) in patients with ST-elevation myocardial infarction (STEMI).
Methods:
Patients with STEMI who underwent pPCI using iso-osmolar contrast were enrolled at 39 centers. The incidence of acute kidney injury (AKI) and major adverse renal and cardiovascular events (MARCE) was analyzed, as well as inpatient costs. Logistic regression analysis was performed to identify risk factors.
Results:
Among 2,293 patients, the incidence of AKI and MARCE within 72 hours post-pPCI was 4.14% (n = 95) and 4.40% (n = 101), respectively. AKI and/or MARCE were associated with systolic blood pressure (AKI: odds ratio [OR], 1.009; 95% confidence interval [CI], 1.000–1.018), hypertension (AKI: OR, 1.815; 95% CI, 1.133–2.906; MARCE: OR, 1.760;95% CI, 1.118–2.769), anterior wall infarction (AKI: OR, 1.895; 95% CI, 1.196–3.004; MARCE:OR, 1.939; 95% CI, 1.240–3.032), Killip class (AKI: OR, 1.465; 95% CI, 1.117–1.922; MARCE:OR, 1.467; 95% CI, 1.131–1.903), and serum creatinine (SCr; MARCE: OR, 1.006; 95% CI, 1.000–1.012). Hospitalization costs for patients with STEMI who developed AKI or MARCE were significantly higher than for those without AKI (9,595 ± 5,795 vs. 8,279 ± 3,872 USD, P = 0.003) or without MARCE (9,890 ± 5,616 vs. 8,255 ± 3,859 USD, P < 0.001).
Conclusions
In patients with STEMI undergoing pPCI with iso-osmolar contrast, the incidence of AKI and MARCE was associated with higher hospitalization costs. Systolic blood pressure, hypertension, anterior wall infarction, Killip class, and SCr were identified as risk factors for these outcomes.
2.Expert consensus on the application of artificial intelligence in lung cancer screening, diagnosis, and treatment (2026 edition)
Wenzhao ZHONG ; Haibo WANG ; Yi HU ; Hao ZHANG ; Jigang DAI ; Junqiang FAN ; Guibin QIAO ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Zihao CHEN ; Hongxia TIAN ; Lunxu LIU ; Hecheng LI ; Xiaolong YAN ; Zongyang YU ; Zhenbin QIU ; Yihua SUN ; Jing HU ; Yuhang SHI ; Zhifei GUO ; Peng ZHANG ; Kezhong CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):848-856
With the continuous deepening of the concept of precision diagnosis and treatment for lung cancer, how to achieve higher efficiency and accuracy in the screening, diagnosis, and treatment pathways in clinical practice has become an important issue that urgently needs to be overcome. The current clinical difficulty lies in the fact that despite continuous advancements in imaging and molecular diagnostic technologies, there are still limitations in manual efficiency and subjective experience when it comes to massive data analysis and multi-scale feature extraction. Artificial intelligence (AI), especially algorithm systems based on deep learning, is an innovative technology capable of deeply empowering medical big data. This method utilizes algorithms such as convolutional neural networks, combined with radiomics, pathomics, and multi-modal data fusion analysis, demonstrating immense potential in early precise detection and benign-malignant differentiation of pulmonary nodules, digital pathological subtype recognition and non-invasive prediction of driver genes, precise 3D surgical planning and automatic delineation of radiotherapy target volumes, as well as dynamic risk warning during follow-up. This innovative technology provides a brand-new solution for realizing intelligent and individualized lung cancer diagnosis and treatment models. This consensus, based on the latest evidence from evidence-based medicine and combined with the development trends in the AI field and real-world clinical needs, was ultimately formed by gathering the consensus opinions of multidisciplinary experts in radiology, pathology, thoracic surgery, and other fields. The main content covers the application specifications of AI in the three core scenarios of lung cancer screening, diagnosis, and treatment, the technical standards for data collection and algorithm validation, as well as the ethical and regulatory challenges faced at the current stage. It aims to clarify the applicable boundaries of AI as a clinical auxiliary decision support tool, providing scientific guidance and standardized exploration directions for peers currently engaged in or planning to carry out AI-assisted clinical diagnosis, treatment, and translation of lung cancer.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Prognostic efficacy of pericoronary fat attenuation index and fibrous plaque index in patients with acute coronary syndrome
Cong HUANG ; Feng WEN ; Xinglan WANG ; Chen LIU ; Hongqin LIANG ; Xi YANG ; Chengwei MOU ; Jian WANG
Journal of Army Medical University 2025;47(17):2106-2114
Objective To explore the predictive value of fat attenuation index(FAI)and fibrous plaque index(FPI)for the prognosis of patients with acute coronary syndrome(ACS).Methods A retrospective cohort study was conducted on 334 ACS patients undergoing percutaneous coronary intervention(PCI)in the First Affiliated Hospital of Army Military Medical University and Yongchuan Hospital of Chongqing Medical University from March 2021 to July 2023.All patients received coronary computed tomography angiography(CCTA)to measure FAI and FPI.According to the occurrence of major adverse cardiovascular events(MACE)with 1 year of follow-up,they were divided into MACE group(n=108)and non-MACE group(n=226).The baseline data,CCTA data and results of laboratory tests were collected and compared between the 2 groups.Multivariate logistic regression analysis was used to analyze the relationship of FAI and FPI with the prognosis of ACS patients,and ROC curve was drawn to evaluate its predictive efficiency.Results Among the 334 ACS patients,108(32.34%)experienced MACE.When compared with the non-MACE group,the MACE group exhibited significantly larger proportions of diabetes(72.22%vs 31.86%)and left main coronary artery disease(18.52%vs 7.08%),but lower success rate of operation(79.63%vs 93.81%,P<0.05).Radiologic results showed that the proportion of severe stenosis(20.37%vs 10.62%),FAI(-80.12±6.41 HU vs-72.34±7.09 HU)and FPI(0.58±0.41 vs 0.26±0.12)were obviously increased in the MACE group than the non-MACE group(P<0.05).Laboratory tests indicated that there were statistical differences between the 2 groups in high-density lipoprotein-cholesterol(HDL-C,1.20±0.15 vs 1.09±0.16 mmol/L),miR-126(0.91±0.12 vs 0.96±0.15)and SST2(38.45±5.67 vs 34.30±4.89 ng/mL,P<0.05).Multivariate Logistic regression analysis revealed that FAI(OR=1.200,95%CI:1.136~1.268),FPI(OR=63.157,95%CI:14.126~282.374),moderate stenosis(OR=1.332,95%CI:1.024~1.859),severe stenosis(OR=1.480,95%CI:1.074~2.039),miR-126(OR=0.007,95%CI:0.001~0.077),and sST2(OR=1.192,95%CI:1.113~1.277)were independent predictors of MACE(P<0.05).ROC curve analysis displayed that stenosis degree(AUC=0.622,95%CI:0.561~0.683,P=0.001),FAI(AUC=0.790,95%CI:0.741~0.839,P=0.001)and FPI(AUC=0.700,95%CI:0.638~0.761,P=0.001),miR-126(AUC=0.646,95%CI:0.584~0.707,P=0.001),sST2(AUC=0.700,95%CI:0.638~0.761,P=0.001)had certain predictive values for ACS prognosis.Conclusion Coronary FAI and FPI can be used as independent prognostic indicators of ACS patients,and their numerical changes are closely related to plaque stability and inflammatory state.
8.Influence of balloon post-dilatation on cardiac conduction in patients undergoing transcatheter aortic valve replacement: A retrospective cohort study
Wuchao XUE ; Yang LIU ; Ping JIN ; Meng' ; en ZHAI ; Linhe LU ; Yan ZHU ; Jian YANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1716-1621
Objective To analyze the impact of balloon post-dilation on cardiac conduction in patients undergoing transcatheter aortic valve replacement (TAVR). Methods From June 2021 to December 2022, patients with severe aortic valve stenosis or regurgitation who underwent TAVR surgery using domestically produced valves at Xijing Hospital, Air Force Military Medical University were selected. The occurrence of intraoperative and postoperative cardiac conduction block was recorded. According to whether balloon post-dilation was performed during the surgery, patients were divided into the post-dilation group and the non-post-dilation group. The baseline data, postoperative cardiac conduction block occurrence, and cardiac function of the two groups were analyzed. Results A total of 126 patients were included, including 52 males and 74 females, with an average age of (66.6±7.6) years. There were 30 patients in the post-dilation group and 96 patients in the non-post-dilation group. On the first day after TAVR, the average QRS intervals in the post-dilation group and the non-post-dilation group were (105.6±13.8) ms and (125.9±28.2) ms, respectively (P=0.017). At discharge, the average PR intervals in the two groups were (168.7±36.8) ms and (192.1±44.2) ms, respectively (P=0.024). At discharge, 9 (7.1%) patients developed new atrioventricular block, 5 (4.0%) patients developed new complete right bundle branch block, and 33 (26.2%) patients developed new complete left bundle branch block. During hospitalization, 2 (1.6%) patients received permanent cardiac pacemakers, both of whom were in the non-post-dilation group. There was no statistical difference in postoperative left ventricular structure and function between the two groups (P>0.05). Conclusion Postoperative expansion using domestically produced interventional valves for TAVR do not increase the incidence of early atrioventricular block and permanent cardiac pacemaker implantation after valve implantation, and there are no significant changes in cardiac structure and function in patients with conduction block in the short term after surgery.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Development, reliability, and validity of a treatment-related quality of life scale for Chinese patients with multiple myeloma
Chunyan SUN ; Zhen CAI ; Bing CHEN ; Lijuan CHEN ; Wenming CHEN ; Kaiyang DING ; Juan DU ; Rong FU ; Chengcheng FU ; Da GAO ; Guangxun GAO ; Yanjuan HE ; Jian HOU ; Ming JIANG ; Fei LI ; Jian LI ; Juan LI ; Zhenyu LI ; Aijun LIAO ; Jing LIU ; Jun LUO ; Jianmin LUO ; Yanping MA ; Jianqing MI ; Ting NIU ; Hongling PENG ; Yongping SONG ; Luqun WANG ; Rong ZHAN ; Xi ZHANG ; Yu HU
Chinese Journal of Hematology 2025;46(8):713-721
Objective:To develop a treatment-related quality of life scale for Chinese patients with multiple myeloma (MM) and to test its reliability and validity.Methods:The initial scale was constructed through a literature search, Delphi expert correspondence, and cognitive testing. This study conducted a preliminary survey of 379 patients with MM and a formal survey of 865 patients from the hematology departments of 155 hospitals nationwide from February 2024 to March 2024. The final scale was obtained after conducting item analysis and reliability and validity tests on the initial scale.Results:The constructed scale contains 36 items covering six domains: physiological, psychological, social, treatment side effects, general health, and others. In the preliminary survey, the Cronbach’s alpha coefficient of each item ranged from 0.597 to 0.939, and the test-retest reliability was 0.747 ( P<0.001). Exploratory factor analysis extracted eight common factors with a cumulative variance contribution of 60.058%. In the formal survey, the Cronbach’s alpha coefficient of each item ranged from 0.484 to 0.930, and the test-retest reliability was 0.835 ( P<0.001). Confirmatory factor analysis revealed a comparative fit index of 0.750, a root-mean-square error of approximation of 0.090, and a root-mean-square residual of 0.067. Conclusion:The treatment-related quality of life scale for Chinese patients with MM designed in this study exhibited good reliability and validity, reflecting the impact of treatment on the quality of life of patients. This scale can provide a reference to clinicians for assessing the disease status of patients.

Result Analysis
Print
Save
E-mail