1.Clinical and Neuroelectrophysiological Features of Autoimmune Nodopathy
Hongfei TAI ; Xunyan HUANG ; Songtao NIU ; Bin CHEN ; Yuzhi SHI ; Xingao WANG ; Fan JIAN ; Hua PAN ; Zaiqiang ZHANG
JOURNAL OF RARE DISEASES 2026;5(2):191-199
To summarize the clinical characteristics, antibody spectrum and neuroelectrophysiological features of autoimmune nodopathy(AN), and to explore the phenotypic differences among different antibody-positive subgroups. The clinical and electrophysiological data of patients definitely diagnosed with AN in Beijing Tiantan Hospital, Capital Medical University, from October 2018 to January 2026 were retrospectively analyzed. A total of 33 patients with AN were included. Antibody examination results showed that, anti-neurofascin(NF)155 antibody was the most prevalent, detected in 17 patients(51.50%), followed by anti-contactin-1(CNTN1) antibody in 8 patients(24.24%). Anti-NF186 antibody(4 cases, 12.12%), anti-contactin-associated protein 1(Caspr1) antibody(2 cases, 6.06%) and dual-target antibody positivity(2 cases, 6.06%) were relatively uncommon. The main clinical manifestations of AN patients included symmetric distal paresthesia of the extremities(32 cases, 96.97%), limb weakness(31 cases, 93.93%) and sensory ataxia(25 cases, 75.76%). Different antibody-positive subgroups presented distinct phenotypic features: patients with positive anti-NF155 antibody had a relatively younger age of onset, chronic onset and a high incidence of tremor, which was dominated by immunoglobulin(Ig)G4 subclass antibodies; patients with positive anti-CNTN1 antibody had a relatively advanced age of onset, mostly presented with acute or subacute onset, and were prone to complicated nephrotic syndrome; patients with positive anti-NF186 antibody had relatively mild nerve conduction damage; patients with anti-Caspr1 antibody manifested acute or subacute onset, with relatively elevated cerebrospinal fluid protein level and 24-h intrathecal IgG synthesis rate. The prominent neuroelectrophysiological manifestations of AN included decreased motor and sensory nerve conduction velocities, prolonged distal latency, frequent non-compressive conduction block and abnormal temporal dispersion. Definite sensory nerve action potentials could not be elicited in more than half of the patients. Patients with AN show high heterogeneity in clinical and neuroelectrophysiological characteristics, and different antibody-positive subgroups correspond to specific clinical and neuroelectrophysiological phenotypes.
2.Chinese expert consensus on the clinical application of recombinant human thyroid-stimulating hormone (2025 edition)
Chentian SHEN ; Yushen GU ; Hui TAN ; Anren KUANG ; Sijin LI ; Yaming LI ; Jing WANG ; Ningyi JIANG ; Jian TAN ; Zhuoying WANG ; Shaoyan LIU ; Xiaoyi LI ; Jugao FANG ; Dingcun LUO ; Youben FAN ; Hui WANG ; Yuetao WANG ; Xuemei WANG ; Feng WANG ; Wei FU ; Feng SHI ; Xuegong LIU ; Zhongwei LÜ ; Yan XING ; Lin LI ; Hui YANG ; Jun XIN ; Yifan ZHANG ; Yue CHEN ; Yansong LIN ; Wei OUYANG ; Shuzhan YAO ; Changjiu ZHAO ; Xinming ZHAO ; Zairong GAO ; Dingde HUANG ; Qiang WEN ; Xingmin HAN ; Cen LOU ; Weibing MIAO ; Wei FAN ; Quanyong LUO ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2026;33(5):932-944
The recombinant human thyroid-stimulating hormone (rhTSH) can be used for differentiated thyroid cancer (DTC) preparation before 131I therapy, and follow-up. Since its approval by the American Food and Drug Administration (FDA) in 1998, rhTSH has been clinically used in European countries, the United States, and other countries for nearly 30 years. In April 2024, China’s first independently developed rhTSH agent was approved. Based on clinical experience and evidence from domestic and international studies, an expert consensus on the application of rhTSH has been developed following thorough consultations among experts. The consensus offers evidence-based recommendations to guide the appropriate use of rhTSH in clinical practice.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Plasma miRNA testing in the differential diagnosis of very early-stage hepatocellular carcinoma: a multicenter real-world study
Jie HU ; Ying XU ; Ao HUANG ; Lei YU ; Zheng WANG ; Xiaoying WANG ; Xinrong YANG ; Zhenbin DING ; Qinghai YE ; Yinghong SHI ; Shuangjian QIU ; Huichuan SUN ; Qiang GAO ; Jia FAN ; Jian ZHOU
Chinese Journal of Clinical Medicine 2025;32(3):350-354
Objective To explore the application of plasma 7 microRNA (miR7) testing in the differential diagnosis of very early-stage hepatocellular carcinoma (HCC). Methods This study is a multicenter real-world study. Patients with single hepatic lesion (maximum diameter≤2 cm) who underwent plasma miR7 testing at Zhongshan Hospital, Fudan University, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Anhui Provincial Hospital, and Peking University People’s Hospital between January 2019 and December 2024 were retrospectively enrolled. Patients were divided into very early-stage HCC group and non-HCC group, and the clinical pathological characteristics of the two groups were compared. The value of plasma miR7 levels, alpha-fetoprotein (AFP), and des-gamma-carboxy prothrombin (DCP) in the differential diagnosis of very early-stage HCC was evaluated using receiver operating characteristic (ROC) curves and area under the curve (AUC). In patients with both negative AFP and DCP (AFP<20 ng/mL, DCP<40 mAU/mL), the diagnostic value of plasma miR7 for very early-stage HCC was analyzed. Results A total of 64 528 patients from 4 hospitals underwent miR7 testing, and 1 682 were finally included, of which 1 073 were diagnosed with very early-stage HCC and 609 were diagnosed with non-HCC. The positive rate of miR7 in HCC patients was significantly higher than that in non-HCC patients (67.9% vs 24.3%, P<0.001). ROC curves showed that the AUCs for miR7, AFP, and DCP in distinguishing HCC patients from the non-HCC individuals were 0.718, 0.682, and 0.642, respectively. The sensitivities were 67.85%, 43.71%, and 44.45%, and the specificities were 75.70%, 92.78%, and 83.91%, respectively. The pairwise comparison of AUCs showed that the diagnostic efficacy of plasma miR7 detection was significantly better than that of AFP or DCP (P<0.05). Although its specificity was slightly lower than AFP and DCP, the sensitivity was significantly higher. Among patients negative for both AFP and DCP, miR7 maintained an AUC of 0.728 for diagnosing very early-stage HCC, with 67.82% sensitivity and 77.73% specificity. Conclusions Plasma miR7 testing is a potential molecular marker with high sensitivity and specificity for the differential diagnosis of small hepatic nodules. In patients with very early-stage HCC lacking effective molecular markers (negative for both AFP and DCP), miR7 can serve as a novel and effective molecular marker to assist diagnosis.
6.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
7.Erratum: Author correction to "Generation of αGal-enhanced bifunctional tumor vaccine" Acta Pharm Sin B 12 (2022) 3177-3186.
Jian HE ; Yu HUO ; Zhikun ZHANG ; Yiqun LUO ; Xiuli LIU ; Qiaoying CHEN ; Pan WU ; Wei SHI ; Tao WU ; Chao TANG ; Huixue WANG ; Lan LI ; Xiyu LIU ; Yong HUANG ; Yongxiang ZHAO ; Lu GAN ; Bing WANG ; Liping ZHONG
Acta Pharmaceutica Sinica B 2025;15(2):1207-1207
[This corrects the article DOI: 10.1016/j.apsb.2022.03.002.].
8.Expert consensus on peri-implant keratinized mucosa augmentation at second-stage surgery.
Shiwen ZHANG ; Rui SHENG ; Zhen FAN ; Fang WANG ; Ping DI ; Junyu SHI ; Duohong ZOU ; Dehua LI ; Yufeng ZHANG ; Zhuofan CHEN ; Guoli YANG ; Wei GENG ; Lin WANG ; Jian ZHANG ; Yuanding HUANG ; Baohong ZHAO ; Chunbo TANG ; Dong WU ; Shulan XU ; Cheng YANG ; Yongbin MOU ; Jiacai HE ; Xingmei YANG ; Zhen TAN ; Xiaoxiao CAI ; Jiang CHEN ; Hongchang LAI ; Zuolin WANG ; Quan YUAN
International Journal of Oral Science 2025;17(1):51-51
Peri-implant keratinized mucosa (PIKM) augmentation refers to surgical procedures aimed at increasing the width of PIKM. Consensus reports emphasize the necessity of maintaining a minimum width of PIKM to ensure long-term peri-implant health. Currently, several surgical techniques have been validated for their effectiveness in increasing PIKM. However, the selection and application of PIKM augmentation methods may present challenges for dental practitioners due to heterogeneity in surgical techniques, variations in clinical scenarios, and anatomical differences. Therefore, clear guidelines and considerations for PIKM augmentation are needed. This expert consensus focuses on the commonly employed surgical techniques for PIKM augmentation and the factors influencing their selection at second-stage surgery. It aims to establish a standardized framework for assessing, planning, and executing PIKM augmentation procedures, with the goal of offering evidence-based guidance to enhance the predictability and success of PIKM augmentation.
Humans
;
Consensus
;
Dental Implants
;
Mouth Mucosa/surgery*
;
Keratins
9.Targeted screening and profiling of massive components of colistimethate sodium by two-dimensional-liquid chromatography-mass spectrometry based on self-constructed compound database.
Xuan LI ; Minwen HUANG ; Yue-Mei ZHAO ; Wenxin LIU ; Nan HU ; Jie ZHOU ; Zi-Yi WANG ; Sheng TANG ; Jian-Bin PAN ; Hian Kee LEE ; Yao-Zuo YUAN ; Taijun HANG ; Hai-Wei SHI ; Hongyuan CHEN
Journal of Pharmaceutical Analysis 2025;15(2):101072-101072
In-depth study of the components of polymyxins is the key to controlling the quality of this class of antibiotics. Similarities and variations of components present significant analytical challenges. A two-dimensional (2D) liquid chromatography-mass spectrometr (LC-MS) method was established for screening and comprehensive profiling of compositions of the antibiotic colistimethate sodium (CMS). A high concentration of phosphate buffer mobile phase was used in the first-dimensional LC system to get the components well separated. For efficient and high-accuracy screening of CMS, a targeted method based on a self-constructed high resolution (HR) mass spectrum database of CMS components was established. The database was built based on the commercial MassHunter Personal Compound Database and Library (PCDL) software and its accuracy of the compound matching result was verified with six known components before being applied to genuine sample screening. On this basis, the unknown peaks in the CMS chromatograms were deduced and assigned. The molecular formula, group composition, and origins of a total of 99 compounds, of which the combined area percentage accounted for more than 95% of CMS components, were deduced by this 2D-LC-MS method combined with the MassHunter PCDL. This profiling method was highly efficient and could distinguish hundreds of components within 3 h, providing reliable results for quality control of this kind of complex drugs.
10.Machine learning-assisted microfluidic approach for broad-spectrum liposome size control.
Yujie JIA ; Xiao LIANG ; Li ZHANG ; Jun ZHANG ; Hajra ZAFAR ; Shan HUANG ; Yi SHI ; Jian CHEN ; Qi SHEN
Journal of Pharmaceutical Analysis 2025;15(6):101221-101221
Liposomes serve as critical carriers for drugs and vaccines, with their biological effects influenced by their size. The microfluidic method, renowned for its precise control, reproducibility, and scalability, has been widely employed for liposome preparation. Although some studies have explored factors affecting liposomal size in microfluidic processes, most focus on small-sized liposomes, predominantly through experimental data analysis. However, the production of larger liposomes, which are equally significant, remains underexplored. In this work, we thoroughly investigate multiple variables influencing liposome size during microfluidic preparation and develop a machine learning (ML) model capable of accurately predicting liposomal size. Experimental validation was conducted using a staggered herringbone micromixer (SHM) chip. Our findings reveal that most investigated variables significantly influence liposomal size, often interrelating in complex ways. We evaluated the predictive performance of several widely-used ML algorithms, including ensemble methods, through cross-validation (CV) for both liposome size and polydispersity index (PDI). A standalone dataset was experimentally validated to assess the accuracy of the ML predictions, with results indicating that ensemble algorithms provided the most reliable predictions. Specifically, gradient boosting was selected for size prediction, while random forest was employed for PDI prediction. We successfully produced uniform large (600 nm) and small (100 nm) liposomes using the optimised experimental conditions derived from the ML models. In conclusion, this study presents a robust methodology that enables precise control over liposome size distribution, offering valuable insights for medicinal research applications.

Result Analysis
Print
Save
E-mail