1.Relationship between GST gene polymorphism and susceptibility to occupational noise induced hearing loss
Fang JI ; Jian ZHANG ; Li RONG ; Xiaowen DING ; Xianglan CUI ; Xiaodong LIU ; Jue LI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(10):728-734
Objective:To investigate the relationship between susceptibility to hearing loss in noise-exposed Han Chinese male homo sapiens and glutathione S-transferase (GST) gene polymorphisms, providing a scientific basis for further understanding the pathogenic mechanisms of noise-induced hearing loss (NIHL) and screening for genetic susceptibility biomarkers.Methods:In May 2024, a cross-sectional survey was conducted to recruit 332 male Han workers exposed to noise from a prominent mechanical maintenance enterprise. Workers were classified into the hearing loss group if they exhibited a binaural high-frequency average hearing threshold exceeding 25 dB and a binaural speech frequency average hearing threshold loss that was less than the binaural high-frequency average hearing threshold loss, resulting in a total of 332 individuals in this group. Furthermore, a matched group of 332 hearing-normal workers was established on a 1∶1 basis for each hearing-impaired worker, using criteria such as the same job type, age, and a noise exposure duration of ≤4 years. Basic data of worker was collected through a questionnaire survey, and individual noise exposure levels were assessed using cumulative noise exposure (CNE). Various PCR and high-throughput sequencing techniques were employed to identify polymorphisms in the GSTT1, GSTM1, and GSTP1rs1695 genes. The basic information and genotypes of the two groups were compared using paired t-tests and paired chi-square tests. A Cox regression model was utilized to establish a 1∶1 paired logistic regression model to examine the correlation between GST gene polymorphisms and susceptibility to NIHL. Results:Individuals with GSTM1 and GSTT1 gene deletion are more susceptible to NIHL compared to those with existing genes, even after adjusting for other factors ( OR=1.464, 95% CI: 1.02-2.09; OR=0.68, 95% CI: 1.06-2.02). Wearing protective equipment occasionally, rather than consistently, significantly increases the risk of NIHL ( OR=1.38, 95% CI: 1.01-1.88). There was no link between GSTP1rs1695 polymorphism and NIHL risk ( P>0.05) . Conclusion:The deletion of GSTM1 and GSTT1 genes is an independent influencing factor that increases the risk of NIHL, and can be considered as a genetic susceptibility biomarker for the NIHL population. Strengthening personal hearing protection is an effective measure to reduce the risk of NIHL.
2.Endobronchial Metastasis From Rectal Cancer Treated by High-Frequency Electrocautery Ablation via Bronchoscope and Targeted Drugs:Report of One Case.
Jian-Hua YUAN ; Zong-Zhou XIE ; Y U WEI-LING ; Rong-Hua CUI ; L I JIAN-WANG
Acta Academiae Medicinae Sinicae 2025;47(1):142-145
The lungs are the most common sites of metastases from non-pulmonarymalignancies. Endobronchial metastases are rare and have no specificity in clinical manifestations,thus being prone to misdiagnosis and delayed treatment.The common tumors associated with endobronchial metastasis are renal,breast,and colorectal cancers.This article reported one case of postoperative rectal cancer with endobronchial and lung metastases,which was relieved by high-frequency electrocautery ablation via bronchoscope,chemotherapy,and targeted drugs,aiming to provide a reference for clinical diagnosis and treatment.
Humans
;
Rectal Neoplasms/pathology*
;
Electrocoagulation/methods*
;
Bronchial Neoplasms/drug therapy*
;
Bronchoscopy
;
Lung Neoplasms/secondary*
;
Bronchoscopes
3.Intervention mechanism of Yiqi Fumai Formula in mice with experimental heart failure based on "heart-gut axis".
Zi-Xuan ZHANG ; Yu-Zhuo WU ; Ke-Dian CHEN ; Jian-Qin WANG ; Yang SUN ; Yin JIANG ; Yi-Xuan LIN ; He-Rong CUI ; Hong-Cai SHANG
China Journal of Chinese Materia Medica 2025;50(12):3399-3412
This paper aimed to investigate the therapeutic effect and mechanism of action of the Yiqi Fumai Formula(YQFM), a kind of traditional Chinese medicine(TCM), on mice with experimental heart failure based on the "heart-gut axis" theory. Based on the network pharmacology integrated with the group collaboration algorithm, the active ingredients were screened, a "component-target-disease" network was constructed, and the potential pathways regulated by the formula were predicted and analyzed. Next, the model of experimental heart failure was established by intraperitoneal injection of adriamycin at a single high dose(15 mg·kg~(-1)) in BALB/c mice. After intraperitoneal injection of YQFM(lyophilized) at 7.90, 15.80, and 31.55 mg·d~(-1) for 7 d, the protective effects of the formula on cardiac function were evaluated using indicators such as ultrasonic electrocardiography and myocardial injury markers. Combined with inflammatory factors in the cardiac and colorectal tissue, as well as targeted assays, the relevant indicators of potential pathways were verified. Meanwhile, 16S rDNA sequencing was performed on mouse fecal samples using the Illumina platform to detect changes in gut flora and analyze differential metabolic pathways. The results show that the administration of injectable YQFM(lyophilized) for 7 d significantly increased the left ventricular end-systolic internal diameter, fractional shortening, and ejection fraction of cardiac tissue of mice with experimental heart failure(P<0.05). Moreover, markers of myocardial injury were significantly decreased(P<0.05), indicating improved cardiac function, along with significantly suppressed inflammatory responses in cardiac and intestinal tissue(P<0.05). Additionally, the species of causative organisms was decreased, and the homeostasis of gut flora was improved, involving a modulatory effect on PI3K-Akt signaling pathway-related inflammation in cardiac and colorectal tissue. In conclusion, YQFM can affect the "heart-gut axis" immunity through the homeostasis of the gut flora, thereby exerting a therapeutic effect on heart failure. This finding provides a reference for the combination of TCM and western medicine to prevent and treat heart failure based on the "heart-gut axis" theory.
Animals
;
Drugs, Chinese Herbal/administration & dosage*
;
Heart Failure/microbiology*
;
Mice
;
Mice, Inbred BALB C
;
Male
;
Disease Models, Animal
;
Gastrointestinal Microbiome/drug effects*
;
Heart/physiopathology*
;
Humans
;
Signal Transduction/drug effects*
4.Precise suctioning scheme for intravenous drug dispensing based on vial dispensing robot
Xian-tao QIN ; Tai-min LUO ; Li YANG ; Peng GAO ; Jian-rong CUI
Chinese Medical Equipment Journal 2025;46(9):45-51
Objective To propose a precise suctioning scheme for intravenous drug dispensing based on the vial dispensing robot to enhance the quality of finished infusion.Methods Six kinds of typical representative vial drugs were selected as the research objects,including pantoprazole sodium for injection,papaverine hydrochloride for injection,cefuroxime sodium for injection,Bozhi Glycopeptide Injection,Esomeprazole Sodium for Injection and Methylprednisolone Sodium Succinate for injection.The optimal suction speed was determined by studying the relationship between the size parameters of vials and the suction speed of robot dispensing,which was used to carry out drug dispensing with the vial dispensing robot to verify whether the minimum drug residue could be obtained with the speed.The drug residue was compared with that by manual dispensing.SPSS 24.0 and Excel 2021 were applied to statistical analysis.Results The optimal suction efficiency and minimized drug residue could be got with the depth of the syringe needle hole into the rubber plug(X)less than the height of the rubber plug(H)and the optimal suction speed(Vs)of 7.48 mm/s;the suction efficiency could be ensured without air drawn in when X not less than H and Vs ranging from 10.64 to 39.31 mm/s.The mean values of the drug residue by the robot were all lower than those by manual dispensing,with the differences being statistically significant(P<0.05).Conclusion The proposed scheme can be used for optimizing the parameters of the vial vial dispensing robot to obtain infusion solution with high stability and reliability,which promotes standardization and normalization of intravenous infusion dispensing process.[Chinese Medical Equipment Journal,2025,46(9):45-51]
5.Relationship between GST gene polymorphism and susceptibility to occupational noise induced hearing loss
Fang JI ; Jian ZHANG ; Li RONG ; Xiaowen DING ; Xianglan CUI ; Xiaodong LIU ; Jue LI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(10):728-734
Objective:To investigate the relationship between susceptibility to hearing loss in noise-exposed Han Chinese male homo sapiens and glutathione S-transferase (GST) gene polymorphisms, providing a scientific basis for further understanding the pathogenic mechanisms of noise-induced hearing loss (NIHL) and screening for genetic susceptibility biomarkers.Methods:In May 2024, a cross-sectional survey was conducted to recruit 332 male Han workers exposed to noise from a prominent mechanical maintenance enterprise. Workers were classified into the hearing loss group if they exhibited a binaural high-frequency average hearing threshold exceeding 25 dB and a binaural speech frequency average hearing threshold loss that was less than the binaural high-frequency average hearing threshold loss, resulting in a total of 332 individuals in this group. Furthermore, a matched group of 332 hearing-normal workers was established on a 1∶1 basis for each hearing-impaired worker, using criteria such as the same job type, age, and a noise exposure duration of ≤4 years. Basic data of worker was collected through a questionnaire survey, and individual noise exposure levels were assessed using cumulative noise exposure (CNE). Various PCR and high-throughput sequencing techniques were employed to identify polymorphisms in the GSTT1, GSTM1, and GSTP1rs1695 genes. The basic information and genotypes of the two groups were compared using paired t-tests and paired chi-square tests. A Cox regression model was utilized to establish a 1∶1 paired logistic regression model to examine the correlation between GST gene polymorphisms and susceptibility to NIHL. Results:Individuals with GSTM1 and GSTT1 gene deletion are more susceptible to NIHL compared to those with existing genes, even after adjusting for other factors ( OR=1.464, 95% CI: 1.02-2.09; OR=0.68, 95% CI: 1.06-2.02). Wearing protective equipment occasionally, rather than consistently, significantly increases the risk of NIHL ( OR=1.38, 95% CI: 1.01-1.88). There was no link between GSTP1rs1695 polymorphism and NIHL risk ( P>0.05) . Conclusion:The deletion of GSTM1 and GSTT1 genes is an independent influencing factor that increases the risk of NIHL, and can be considered as a genetic susceptibility biomarker for the NIHL population. Strengthening personal hearing protection is an effective measure to reduce the risk of NIHL.
6.Precise suctioning scheme for intravenous drug dispensing based on vial dispensing robot
Xian-tao QIN ; Tai-min LUO ; Li YANG ; Peng GAO ; Jian-rong CUI
Chinese Medical Equipment Journal 2025;46(9):45-51
Objective To propose a precise suctioning scheme for intravenous drug dispensing based on the vial dispensing robot to enhance the quality of finished infusion.Methods Six kinds of typical representative vial drugs were selected as the research objects,including pantoprazole sodium for injection,papaverine hydrochloride for injection,cefuroxime sodium for injection,Bozhi Glycopeptide Injection,Esomeprazole Sodium for Injection and Methylprednisolone Sodium Succinate for injection.The optimal suction speed was determined by studying the relationship between the size parameters of vials and the suction speed of robot dispensing,which was used to carry out drug dispensing with the vial dispensing robot to verify whether the minimum drug residue could be obtained with the speed.The drug residue was compared with that by manual dispensing.SPSS 24.0 and Excel 2021 were applied to statistical analysis.Results The optimal suction efficiency and minimized drug residue could be got with the depth of the syringe needle hole into the rubber plug(X)less than the height of the rubber plug(H)and the optimal suction speed(Vs)of 7.48 mm/s;the suction efficiency could be ensured without air drawn in when X not less than H and Vs ranging from 10.64 to 39.31 mm/s.The mean values of the drug residue by the robot were all lower than those by manual dispensing,with the differences being statistically significant(P<0.05).Conclusion The proposed scheme can be used for optimizing the parameters of the vial vial dispensing robot to obtain infusion solution with high stability and reliability,which promotes standardization and normalization of intravenous infusion dispensing process.[Chinese Medical Equipment Journal,2025,46(9):45-51]
7.Embolization of the inferior mesenteric artery and lumbar arteries during endovascular aortic repair for the prevention of type Ⅱ endoleak:clinical significance and research progress
Chengpeng TAN ; Dan RONG ; Hao LIU ; Zihan ZHANG ; Jian HE ; Peng JIANG ; Yongpan CUI ; Fei MEI
Chinese Journal of General Surgery 2024;33(12):2051-2057
Abdominal aortic aneurysm (AAA) is a type of aneurysmal aortic disease with a high mortality rate. Endovascular aneurysm repair (EVAR) is an effective treatment for this condition,but endoleaks can occur intraoperatively or years after the procedure,necessitating lifelong monitoring. Type Ⅱ endoleak (T2EL) is a major complication of EVAR,primarily caused by persistent retrograde perfusion of the aneurysm sac from collateral vessels such as the inferior mesenteric artery (IMA) and lumbar arteries (LA). The occurrence of T2EL is closely related to patient anatomical factors (e.g.,the diameter,number,and patency of collateral vessels),surgical factors (e.g.,the degree of stent graft adherence to the arterial wall),and systemic factors such as hypertension. Persistent T2EL may lead to aneurysm sac enlargement and increased risk of rupture,thereby adversely affecting patient prognosis. In recent years,prophylactic embolization of the IMA and LA has shown certain advantages in reducing the incidence of T2EL,aneurysm sac enlargement,and reintervention rates,contributing positively to improving treatment outcomes and quality of life of the patients. Here,the authors reviewed literature published between January 2002 and July 2024 on the epidemiology of endoleaks following EVAR and the use of IMA and LA embolization during EVAR to prevent T2EL. The current research was summarized to discuss the clinical value of prophylactic IMA and LA embolization in patients at high risk of T2EL.
8.Chidamide plus prednisone, cyclophosphamide, and thalidomide for relapsed or refractory peripheral T-cell lymphoma: A multicenter phase II trial
Jinhua LIANG ; Li WANG ; Xiaodong WANG ; Guohui CUI ; Jianfeng ZHOU ; Tongyao XING ; Kaixin DU ; Jingyan XU ; Luqun WANG ; Rong LIANG ; Biyun CHEN ; Jian CHENG ; Haorui SHEN ; Jianyong LI ; Wei XU
Chinese Medical Journal 2024;137(13):1576-1582
Background::Although the treatment of peripheral T-cell lymphoma (PTCL) has undergone advancements during the past several years, the response rate and long-term effects with respect to patients with PTCL remain unsatisfactory—particularly for relapsed or refractory (R/R) patients. This phase II trial was designed to explore the efficacy and safety of an all-oral regimen of chidamide plus prednisone, cyclophosphamide, and thalidomide (CPCT) for R/R PTCL patients who could not tolerate the standard chemotherapy for a variety of reasons.Methods::We conducted a multicenter phase II clinical trial in which we combined chidamide (30 mg twice weekly) with prednisone (20 mg daily after breakfast), cyclophosphamide (50 mg daily after lunch), and thalidomide (100 mg daily at bedtime) (the CPCT regimen) for a total of fewer than 12 cycles as an induction-combined treatment period, and then applied chidamide as single-drug maintenance. Forty-five patients were ultimately enrolled from August 2016 to April 2021 with respect to Chinese patients at nine centers. Our primary objective was to assess the overall response rate (ORR) after the treatment with CPCT.Results::Of the 45 enrolled patients, the optimal ORR and complete response (CR)/CR unconfirmed (CRu) were 71.1% (32/45) and 28.9% (13/45), respectively, and after a median follow-up period of 56 months, the median progression-free survival (PFS) and overall survival (OS) were 8.5 months and 17.2 months, respectively. The five-year PFS and OS rates were 21.2% (95% confidence interval [CI], 7.9-34.5%) and 43.8% (95% CI, 28.3-59.3%), respectively. The most common adverse event was neutropenia (20/45, 44.4%), but we observed no treatment-related death.Conclusion::The all-oral CPCT regimen was an effective and safe regimen for R/R PTCL patients who could not tolerate standard chemotherapy for various reasons.Trial Registration::ClinicalTrials.gov, NCT02879526.
9.Synthesis and antibacterial activity evaluation of octapeptin derivatives
He-xian YANG ; A-long CUI ; Yong-jian WANG ; Shi-bo KOU ; Miao LÜ ; Hong YI ; Zhuo-rong LI
Acta Pharmaceutica Sinica 2024;59(1):152-160
Octapeptin has strong antibacterial activity against Gram-negative bacteria such as
10.Characteristics and influencing factors of hearing loss among noise-exposed workers in a large machinery maintenance enterprise
Fang JI ; Jian ZHANG ; Xiaowen DING ; Xianglan CUI ; Li RONG ; Xuefeng WANG ; Jue LI
Journal of Environmental and Occupational Medicine 2024;41(1):77-82
Background The current increasing trend of new cases of occupational noise-induced deafness indicates that the hearing loss of occupational population has not been effectively controlled in China. It is of great significance to study the characteristics of hearing loss among noise-exposed workers and its related factors. Objective To investigate characteristics and influencing factors of hearing loss among occupational noise-exposed workers in a large machinery maintenance enterprise, and to provide a scientific basis to prevent and control noise-induced hearing loss. Methods A cross-sectional survey was conducted to investigate male Han occupational noise-exposed workers in a large mechanical maintenance enterprise. We acquired demographic characteristics, occupational exposure history, and individual life behavior characteristics of the workers through questionnaires, collected occupational exposure level data from annual occupational disease hazard factor surveillance reports, obtained pure tone hearing threshold test data through occupational health examinations, and estimated individual noise exposure levels using cumulative noise exposure (CNE). According to the results of pure tone air conduction hearing threshold test, the workers were divided into a hearing loss group and a normal hearing group. The chi-square test was employed to compare the occupational exposure characteristics and individual life behavior characteristics between the two groups. Additionally, the trend chi-square test was utilized to analyze the changing trends of age, length of service, CNE, and hearing loss rate within the two groups. The relationship between high-frequency hearing loss in both ears and its related influencing factors was assessed by a multiple logistic regression model. Results The M (P25, P75) of CNE for the 2531 occupational noise-exposed workers was 97.51 (95.39, 99.96) dB(A)·year. The incidence of hearing anomaly, binaural high-frequency hearing anomaly, random ear high-frequency hearing anomaly, binaural low-frequency hearing anomaly, and random ear low-frequency hearing anomaly were 22.48%, 16.59%, 22.13%, 2.77%, and 3.52%, respectively. High-frequency hearing threshold increase was the main reason for hearing anomaly (98.42%). In comparison to the CNE ≤ 97 dB(A)·year group, the 97 dB(A)·year

Result Analysis
Print
Save
E-mail