1.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure
2.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Analgesic effect of dezocine combined with ropivacaine on patients undergoing thoracoscopic radical resection of lung cancer
Zhi-Guo YI ; Wen ZHOU ; Yan-Ping SU ; Fang TANG ; Jian-Dong DENG
The Chinese Journal of Clinical Pharmacology 2024;40(8):1116-1120
Objective To explore the analgesic effect of different doses of dezocine combined with ropivacaine for thoracic paravertebral block(TPVB)on patients undergoing thoracoscopic radical resection of lung cancer and the influence on hemodynamics and immune function of patients.Methods Patients with lung cancer who underwent thoracoscopic radical resection were divided into low-dose group and high-dose group according to random number table method.Both groups of patients were given total intravenous anesthesia to complete the surgery.At 15 min before general anesthesia induction,the low-dose group was given TPBV with 0.1 mg·kg-1 dezocine+0.375%ropivacaine for a total of 20 mL,and the high-dose group was given TPBV with 0.15 mg·kg-1 dezocine+0.375%ropivacaine for a total of 20 mL.Comparisons were performed on both groups in terms of analgesic effect,hemodynamic parameters,immune function and occurrence of adverse drug reactions.Results There were 48 cases in low-dose group and 46 cases in high-dose group.In low-dose group,the heart rate values before TPVB,before skin incision,at 5 min after sectioning and at the end of surgery were(78.52±6.54),(70.79±7.07),(74.48±6.68)and(76.69±7.29)beat·min-1,the mean arterial pressure values were(93.16±5.72),(86.38±7.51),(92.15±6.36)and(91.14±6.13)mmHg.In high-dose group,the heart rate values at the above time points were(79.36±7.11),(71.68±6.49),(74.76±7.06)and(76.57±6.52)beat·min-1;the mean arterial pressure values were(93.89±7.18),(85.27±7.41),(90.34±6.52)and(92.43±6.34)mmHg,there were no statistical differences between the two groups(all P>0.05).The resting state scores at 2,6 and 12 h after surgery were(1.38±0.19),(1.54±0.21)and(1.72±0.16)points,the pain scores at motion state were(1.88±0.15),(2.36±0.37)and(3.26±0.38)points in low-dose group;in high-dose group,the resting state scores were(1.32±0.17),(1.58±0.22)and(1.81±0.18)points,the pain scores at motion state were(1.81±0.13),(2.11±0.31)and(3.03±0.36)points,respectively,there were no statistical differences between the two groups(all P>0.05).The number of analgesic pump compressions at 24 h after surgery and the number of cases with analgesic remedy were(5.12±1.26)times and 15 cases in low-dose group and were(4.74±1.03)times and 10 cases in high-dose group,with no statistical differences between the groups(all P>0.05).The percentages of CD3+cells in low-dose group at the end of surgery and at 12 h and 24 h after surgery were(68.51±6.76)%,(54.22±5.43)%and(51.47±6.58)%,the percentages of CD4+cells were(40.29±5.02)%,(34.94±4.79)%and(30.48±5.11)%,CD4+/CD8+ratios were 1.54±0.34,1.36±0.28 and 1.16±0.23;the percentages of CD3+cells in high-dose group were(67.92±7.11)%,(56.58±6.36)%and(54.47±6.89)%,percentages of CD4+cells were(41.33±5.75)%,(35.86±5.21)%and(32.27±4.78)%,the CD4+/CD8+were 1.53±0.35,1.40±0.30 and 1.22±0.26,all with no significant difference(all P>0.05).The incidence of postoperative adverse drug reactions in high-dose group and low-dose group were 32.61%and 14.58%,with significant difference(P<0.05).Conclusion When TPVB regimen of dezocine combined with ropivacaine is used in thoracoscopic radical resection of lung cancer,the analgesic effect of low-dose dezocine is comparable to that of high-dose dezocine,with lower risk of adverse drug reactions.
8.Isolation, chiral separation and absolute configuration determination of lignanoids from an aqueous extract of the Angelica sinensis root head
Xiao-yi ZHANG ; Zhao XIA ; Xiao-qiang LEI ; Wei-ping LI ; Rong LIU ; Qing-lan GUO ; Jian-gong SHI
Acta Pharmaceutica Sinica 2024;59(7):2077-2086
From an aqueous extract of the
9.Identification and analysis of volatile organic compounds in 6 printing jobs in printing enterprises in Shanghai
Qingtian WAN ; Ying TANG ; Jian CHEN ; Chaoye SHEN ; Yi XU ; Chenyi TAO ; Xia ZHANG ; Ping XIAO
Journal of Environmental and Occupational Medicine 2024;41(11):1240-1245
Background Workers in printing jobs are exposed to a variety of organic solvents at low levels for a long period of time. Previous studies have focused on the main components in Material Safety Data Sheet or high-risk occupational hazardous agents, but have not been able to comprehensively and accurately identify the volatile organic compounds (VOCs) in printing jobs. Objective To qualitatively analyze the VOCs in ink, detergent, varnish, fountain solution, and other raw and auxiliary materials by headspace gas chromatography-mass spectrometry, and to accurately identify the occupational hazardous agents in printing jobs. Methods Raw and auxiliary materials used in printing jobs in 6 printing enterprises in Shanghai were sampled by headspace sampling, analyzed by gas chromatography-mass spectrometry, identified by National Institute of Standards & Technology ( NIST) Standard Library and retention time, and quantified by peak area percentage. Results A total of 181 VOCs were reported in the headspace of 25 organic solvent samples, with a total detection frequency of 337 items and 13.2±12.3 VOCs per sample. The most frequently detected VOCs category was naphthene, with a total of 69 items detected (22.5%), dominated by cyclohexane. The characteristics of VOCs components in the headspace of different types of samples were different. The largest number of VOCs was detected in the headspace of detergent samples, with an average of 31.5 VOCs detected. The characteristic components in detergent were aromatic hydrocarbons and ester compounds; alcohols were the characteristic components in varnish; and ester compounds were the characteristic components in ink. The results of cluster analysis showed that ethanol, toluene, ethyl acetate, cyclohexane, and acetone were occupational hazardous agents with high levels of exposure in printing jobs. Conclusion Many kinds of organic solvents used in printing process are difficult to identify by traditional methods. Headspace gas chromatography-mass spectrometry can help to accurately identify VOCs in the workplace, so as to more accurately assess the occupational hazards, and to provide a technical basis for guiding occupational health monitoring and implementing corresponding occupational health risk management and control.
10.Comparison of the predictive value of new simplified insulin resistance assessment indexes in identifying left ventricular subclinical dysfunction in T2DM patients
Yan-Yan CHEN ; Meng-Ying LI ; Jie ZHOU ; Jian-Fang FU ; Ying ZHANG ; Yi WANG ; Cheng WANG ; Xiang-Yang LIU ; Sheng-Jun TA ; Li-Wen LIU ; Ze-Ping LI ; Xiao-Miao LI
Medical Journal of Chinese People's Liberation Army 2024;49(2):137-143
Objective To investigate the predictive value of new simplified insulin resistance(IR)assessment indexes in identifying subclinical left ventricular systolic function impairment in patients with type 2 diabetes mellitus(T2DM).Methods A total of 150 T2DM patients with preserved left ventricular ejection fraction(LVEF≥50%)who were admitted to Department of Endocrinology of the First Affiliated Hospital of Air Force Medical University from June 2021 to December 2021 were retrospectively analyzed.All patients underwent two-dimensional speckle tracking echocardiography to measure left ventricular global longitudinal strain(GLS).According to GLS value,the subjects were divided into the normal group(GLS≥18%group,n=80)and the impaired group(GLS<18%group,n=70).Some new simplified IR assessment indicators were calculated and compared between the two groups,including body mass index(BMI),TG/HDL-C ratio,triglyceride-glucose(TyG)index,TyG-BMI index,TyG-WHR and metabolic score for IR(METS-IR).Correlation between the GLS and the new simplified IR assessment indexes was analyzed.The receiver operating characteristic(ROC)curve was used to analyze the diagnostic efficacy of different simplified IR assessment indexes,with the area under the curve(AUC)calculated.Furthermore,according to whether the subjects were complicated with hypertension,binary logistics regression analysis was performed to explore the independent correlation between the simplified IR assessment index and GLS<18%.Results Total 150 were included with aged(54.5±13.7)years with 96(64.0%)men and 54(36.0%)women.Compared with the GLS≥18%group,the TG/HDL-C ratio,TyG index,TyG-BMI,and METS-IR of subjects in the GLS<18%group were significantly increased(P<0.05).Pearson correlation analysis showed that TG/HDL-C ratio,TyG index,TyG-BMI,TyG-WHR,and METS-IR were negatively correlated with GLS(P<0.05).ROC analysis showed that TyG index had a certain predictive value for the evaluation of GLS<18%(AUC=0.678,95%CI 0.591-0.765,P<0.001).Stratification based on hypertension and further adjusting for confounding factors,TyG index remains significantly associated with GLS<18%(OR=3.249,95%CI 1.045-10.103,P=0.042).Conclusions The novel simplified insulin resistance evaluation indexes are closely associated with left ventricular subclinical systolic dysfunction in T2DM patients with preserved ejection fraction.TyG index is an effective index to identify left ventricular subclinical dysfunction in these populations.

Result Analysis
Print
Save
E-mail