1.Isolation, chiral separation and absolute configuration determination of lignanoids from an aqueous extract of the Angelica sinensis root head
Xiao-yi ZHANG ; Zhao XIA ; Xiao-qiang LEI ; Wei-ping LI ; Rong LIU ; Qing-lan GUO ; Jian-gong SHI
Acta Pharmaceutica Sinica 2024;59(7):2077-2086
From an aqueous extract of the
2.Development and Application of Portable Multi-wavelength Spectroscopic Rapid Detector for Organic Pollutants
Yu-Ping CHEN ; Jia-Chuan PAN ; Yong-Qian LEI ; Chang-Yu LIU ; Jian-Bo JIA ; Peng-Ran GUO
Chinese Journal of Analytical Chemistry 2024;52(5):653-663,中插1-中插9
A portable multi-wavelength spectral detector was developed for on-site,rapid and accurate detection of organic pollutants in surface water using ultraviolet light-emitting diodes(UV-LEDs)and the corresponding spectral detection method was built.By measuring the fluorescence spectrum and absorption light intensity and combining with the multi-wavelength spectral correlation calculation method to analyze the target,the developed detector was able to qualitatively and quantitatively detect organic pollutants that responded in the UV-light range of 260-370 nm.The proposed detector was used to detect polycyclic aromatic hydrocarbons(PAHs)and Rhodamine B.The linear ranges of anthracene and Rhodamine B in absorption mode were 10-100 and 8.5-100 mg/L,respectively.In fluorescence mode,the linear ranges for anthracene and Rhodamine B were 0.006-50 and 0.02-0.781 mg/L,correspondingly.The absorption/fluorescence concurrent mode could extend the detection ranges of anthracene and Rhodamine B to 0.006-100 and 0.02-100 mg/L,respectively.The recoveries of PAHs in surface water ranged from 97.4%to 105.1%for anthracene and 84.5%to 91.2%for anthracene,naphthalene,and pyrene in absorption and fluorescence modes,respectively.The method was accurate in both modes.The mixtures containing PAHs were identified by the proposed method under the optimized multi-wavelength spectral correlation calculation.The results demonstrated that the method could achieve a similarity of 75%or more when identifying two different concentrations of solutions containing a single or a mixture of targets within the linear concentration range of the targets.However,the similarity dropped to less than 25%when identifying two solutions of different substances.The proposed method had excellent recognition abilityof targets.The proposed detector and method combined fluorescence and absorption spectroscopy,which could expand the application of spectroscopy in the in situ rapid identification and detection of pollutants such as PAHs in surface water.
3.Clinical Efficacy and Safety of Ixazomib-Containing Regimens in the Treatment of Patients with Multiple Myeloma
Ran CHEN ; Lian-Guo XUE ; Hang ZHOU ; Tao JIA ; Zhi-Mei CAI ; Yuan-Xin ZHU ; Lei MIAO ; Ji-Feng WEI ; Li-Dong ZHAO ; Jian-Ping MAO
Journal of Experimental Hematology 2024;32(2):483-492
Objective:To investigate the clinical efficacy and safety of ixazomib-containing regimens in the treatment of patients with multiple myeloma(MM).Methods:A retrospective analysis was performed on the clinical efficacy and adverse reactions of 32 MM patients treated with a combined regimen containing ixazomib in the Hematology Department of the First People's Hospital of Lianyungang from January 2020 to February 2022.Among the 32 patients,15 patients were relapsed and refractory multiple myeloma(R/RMM)(R/RMM group),17 patients who responded to bortezomib induction therapy but converted to ixazomib-containing regimen due to adverse events(AE)or other reasons(conversion treatment group).The treatment included IPD regimen(ixazomib+pomalidomide+dexamethasone),IRD regimen(ixazomib+lenalidomide+dexamethasone),ICD regimen(ixazomib+cyclophosphamide+dexamethasone),ID regimen(ixazomib+dexamethasone).Results:Of 15 R/RMM patients,overall response rate(ORR)was 53.3%(8/15),among them,1 achieved complete response(CR),2 achieved very good partial response(VGPR)and 5 achieved partial response(PR).The ORR of the IPD,IRD,ICD and ID regimen group were 100%(3/3),42.9%(3/7),33.3%(1/3),50%(1/2),respectively,there was no statistically significant difference in ORR between four groups(x2=3.375,P=0.452).The ORR of patients was 50%after first-line therapy,42.9%after second line therapy,60%after third line therapy or more,with no statistically significant difference among them(x2=2.164,P=0.730).In conversion treatment group,ORR was 88.2%(15/17),among them,6 patients achieved CR,5 patients achieved VGPR and 4 patients achieved PR.There was no statistically significant difference in ORR between the IPD(100%,3/3),IRD(100%,6/6),ICD(100%,3/3)and ID(60%,3/5)regimen groups(x2=3.737,P=0.184).The median progression-free survival(PFS)time of R/RMM patients was 9 months(95%CI:6.6-11.4 months),the median overall survival(OS)time was 18 months(95%CI:11.8-24.4 months).The median PFS time of conversion treatment group was 15 months(95%CI:7.3-22.7 months),the median OS time not reached.A total of 10 patients suffered grade 3-4 adverse event(AE).The common hematological toxicities were leukocytopenia,anemia,thrombocytopenia.The common non-hematological toxicities were gastrointestinal symptoms(diarrhea,nausea and vomit),peripheral neuropathy,fatigue and infections.Grade 1-2 peripheral neurotoxicity occurred in 7 patients.Conclusion:The ixazomib-based chemotherapy regimens are safe and effective in R/RMM therapy,particularly for conversion patients who are effective for bortezomib therapy.The AE was manageable and safe.
4.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
5.Monoterpenes from an aqueous extract of the Angelica sinensis root head
Zhao XIA ; You-zhe CHEN ; Xiao-qiang LEI ; Wei-ping LI ; Rong LIU ; Qing-lan GUO ; Jian-gong SHI
Acta Pharmaceutica Sinica 2023;58(6):1641-1649
Eleven monoterpenes including seven new chemical structures or new natural products covering two pairs of scalemic enantiomers, together with four known analogues, were isolated from an aqueous extract of the
6.Efficacy and Safety of Decitabine Combined with Modified EIAG Regimen in the Treatment of Patients with Relapsed/Refractory Acute Myeloid Leukemia and High-risk Myelodysplastic Syndrome.
Jian-Ping MAO ; Lian-Guo XUE ; Yuan-Xin ZHU ; Tao JIA ; Ying WANG ; Lei MIAO ; Ji-Feng WEI ; Li-Dong ZHAO
Journal of Experimental Hematology 2023;31(2):338-343
OBJECTIVE:
To investigate the efficacy, prognosis and safety of decitabine combined with modified EIAG regimen in the treatment of patients with relapsed/refractory acute myeloid leukemia (AML) and high-risk myelodysplastic syndrome (MDS).
METHODS:
The clinical data of 44 patients with relapsed/refractory AML and high-risk MDS admitted to our hospital from January 2017 to December 2020 were analyzed retrospectively. The patients were equally divided into D-EIAG group (decitabine combined with EIAG regimen) and D-CAG group (decitabine combined with CAG regimen) according to clinical treatment regimen. The complete response (CR), CR with incomplete hematologic recover (CRi), morphologic leukemia-free state (MLFS), partial response (PR), overall response rate (ORR), modified composite complete response (mCRc), overall survival (OS) time, 1-year OS rate, myelosuppression and adverse reactions between the two groups were compared.
RESULTS:
In D-EIAG group, 16 patients (72.7%) achieved mCRc (CR+CRi+MLFS), 3 patients (13.6%) achieved PR, and ORR (mCRc+PR) was 86.4%. In D-CAG group, 9 patients (40.9%) achieved mCRc, 6 patients (27.3%) achieved PR, and ORR was 68.2%. Difference was observed in mCRc rate between the two groups (P=0.035), but not in ORR (P>0.05). The median OS time of D-EIAG group and D-CAG group was 20 (2-38) months and 16 (3-32) months, and 1-year OS rate was 72.7% and 59.1%, respectively. There was no significant difference in 1-year OS rate between the two groups (P>0.05). After induction chemotherapy, the median time for absolute neutrophil count recovery to 0.5×109/L in D-EIAG group and D-CAG group was 14 (10-27) d and 12 (10-26) d, for platelet count recovery to 20×109/L was 15 (11-28) d and 14 (11-24)d, the median red blood cell suspension transfusion volume was 8 (6-12) U and 6 (6-12) U, and the median apheresis platelet transfusion volume was 4 (2-8) U and 3 (2-6) U, respectively. There were no statistically significant differences in comparison of the above indicators between the two groups (P>0.05). The hematological adverse reactions of patients were mainly myelosuppression. Grade III-IV hematological adverse events occurred in both groups (100%), with no increase in the incidence of non-hematological toxicities such as gastrointestinal reactions or liver function damage.
CONCLUSION
Decitabine combined with EIAG regimen in the treatment of relapsed/refractory AML and high-risk MDS can improve remission rate, provide an opportunity for subsequent therapies, and have no increase in adverse reactions compared with D-CAG regimen.
Humans
;
Decitabine/therapeutic use*
;
Treatment Outcome
;
Retrospective Studies
;
Cytarabine
;
Myelodysplastic Syndromes/drug therapy*
;
Leukemia, Myeloid, Acute/drug therapy*
;
Bone Marrow Diseases/drug therapy*
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
7.Comparison of CT Values between Thrombus and Postmortem Clot Based on Cadaveric Pulmonary Angiography.
Zhi-Ling TIAN ; Ruo-Lin WANG ; Jian-Hua ZHANG ; Ping HUANG ; Zhi-Qiang QIN ; Zheng-Dong LI ; He-Wen DONG ; Dong-Hua ZOU ; Mao-Wen WANG ; Zhuo LI ; Lei WAN ; Xiao-Tian YU ; Ning-Guo LIU
Journal of Forensic Medicine 2023;39(1):7-12
OBJECTIVES:
To explore the difference in CT values between pulmonary thromboembolism and postmortem clot in postmortem CT pulmonary angiography (CTPA) to further improve the application value of virtual autopsy.
METHODS:
Postmortem CTPA data with the definite cause of death from 2016 to 2019 were collected and divided into pulmonary thromboembolism group (n=4), postmortem clot group (n=5), and control group (n=5). CT values of pulmonary trunk and left and right pulmonary artery contents in each group were measured and analyzed statistically.
RESULTS:
The average CT value in the pulmonary thromboembolism group and postmortem clot group were (168.4±53.8) Hu and (282.7±78.0) Hu, respectively, which were lower than those of the control group (1 193.0±82.9) Hu (P<0.05). The average CT value of the postmortem clot group was higher than that of the pulmonary thromboembolism group (P<0.05).
CONCLUSIONS
CT value is reliable and feasible as a relatively objective quantitative index to distinguish pulmonary thromboembolism and postmortem clot in postmortem CTPA. At the same time, it can provide a scientific basis to a certain extent for ruling out pulmonary thromboembolism deaths.
Humans
;
Autopsy
;
Thrombosis
;
Pulmonary Embolism/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Angiography
;
Cadaver
8.Clinical and gene mutation characteristics of patients with hereditary ellipsocytosis: nine cases report and literature review.
Xu LIU ; Yuan LI ; Xin ZHAO ; Yang YANG ; Li ZHANG ; Li Ping JING ; Lei YE ; Kang ZHOU ; Jian Ping LI ; Guang Xin PENG ; Hui Hui FAN ; Wen Rui YANG ; You Zhen XIONG ; Feng Kui ZHANG
Chinese Journal of Hematology 2023;44(4):316-320
Objective: To report gene mutations in nine patients with hereditary elliptocytosis (HE) and analyze the characteristics of pathogenic gene mutations in HE. Methods: The clinical and gene mutations of nine patients clinically diagnosed with HE at Institute of Hematology & Blood Diseases Hospital from June 2018 to February 2022 were reported and verified by next-generation sequencing to analyze the relationship between gene mutations and clinical phenotypes. Results: Erythrocyte membrane protein gene mutations were detected among nine patients with HE, including six with SPTA1 mutation, one with SPTB mutation, one with EPB41 mutation, and one with chromosome 20 copy deletion. A total of 11 gene mutation sites were involved, including 6 known mutations and 5 novel mutations. The five novel mutations included SPTA1: c.1247A>C (p. K416T) in exon 9, c.1891delG (p. A631fs*17) in exon 15, E6-E12 Del; SPTB: c.154C>T (p. R52W) ; and EPB41: c.1636A>G (p. I546V) . Three of the six patients with the SPTA1 mutation were SPTA1 exon 9 mutation. Conclusion: SPTA1 is the most common mutant gene in patients with HE.
Humans
;
Mutation
;
Elliptocytosis, Hereditary/metabolism*
;
Erythrocyte Membrane/metabolism*
;
Exons
;
High-Throughput Nucleotide Sequencing
;
Spherocytosis, Hereditary/metabolism*
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail