1.Olfactory Receptors Expressed in The Intestine and Their Functions
Pei-Wen YANG ; Meng-Meng YUAN ; Ying ZHOU ; Peng LI ; Gui-Hong QI ; Ying YANG ; Zhong-Yi MAO ; Meng-Sha ZHOU ; Xiao-Shuang MAO ; Jian-Ping XIE ; Yi-Nan YANG ; Shi-Hao SUN
Progress in Biochemistry and Biophysics 2026;53(3):534-549
Olfactory receptors (ORs) form the largest superfamily of G protein-coupled receptors (GPCRs). Traditionally recognized for their role in the nasal olfactory epithelium, where they mediate the sense of smell, accumulating evidence has firmly established their ectopic expression in non-olfactory tissues, including the intestine, lungs, and kidneys. The intestine, as the primary site for nutrient digestion and absorption, harbors a highly complex chemical environment. To adapt to this environment, the gut employs a sophisticated network of “chemosensors” to monitor luminal contents and maintain homeostasis. Among these sensors, intestinal ORs have emerged as crucial functional components, serving as a molecular bridge that connects environmental chemical signals—such as food-derived odorants—to specific physiological responses. This discovery has significantly deepened our understanding of how dietary flavors and compounds influence intestinal physiology at the molecular level. This review systematically summarizes the expression profiles, ligand classification, and biological functions of ORs within the gastrointestinal tract. Studies indicate that intestinal ORs exhibit distinct spatial distribution patterns across different gut segments and display cell-type specificity, particularly within enterocytes and enteroendocrine cells. These receptors function as versatile sensors capable of recognizing a wide variety of ligands, including exogenous dietary components, gut microbiota metabolites such as short-chain fatty acids, and endogenous small molecules like azelaic acid. Upon activation by specific ligands, intestinal ORs trigger intracellular signaling cascades, primarily involving the AC-cAMP-PKA pathway or calcium influx channels. A major focus of this review is to elucidate the molecular mechanisms by which these receptors regulate the secretion of gut hormones. Activation of specific ORs in enteroendocrine cells has been shown to stimulate the release of hormones such as glucagon-like peptide-1 (GLP-1), peptide YY (PYY), and serotonin (5-HT), thereby modulating systemic energy metabolism, glucose homeostasis, and gastrointestinal motility. Furthermore, the review addresses the critical roles of ORs in immune regulation and pathology. Evidence suggests that specific ORs contribute to the maintenance of intestinal immune homeostasis and may offer protection against inflammation. Beyond their involvement in inflammatory responses, ORs such as Olfr78 have been shown to regulate the differentiation and function of intestinal endocrine cells. Similarly, Olfr544 has been demonstrated to alleviate intestinal inflammation by remodeling the gut microbiome and metabolome. These findings collectively suggest that specific ORs hold promise as therapeutic targets for mitigating intestinal inflammation and maintaining gut homeostasis. Additionally, the review explores the emerging role of ORs in cancer. Although OR expression is often downregulated in tumor tissues compared to normal mucosa, activation of specific ORs by certain ligands can inhibit tumor cell proliferation and migration and induce apoptosis via pathways such as MEK/ERK and p38 MAPK. Conversely, other receptors, such as OR7C1, may serve as biomarkers for cancer-initiating cells. In conclusion, intestinal ORs represent a vital component of the gut’s sensory network. The review also discusses the translational potential of these findings. By elucidating the precise pairing relationships between dietary components and specific ORs, novel therapeutic strategies could be developed. Intestinal ORs may thus emerge as promising targets for nutritional and pharmacological interventions in metabolic diseases, inflammatory bowel diseases, and malignancies.
2.Expert consensus on the application of artificial intelligence in lung cancer screening, diagnosis, and treatment (2026 edition)
Wenzhao ZHONG ; Haibo WANG ; Yi HU ; Hao ZHANG ; Jigang DAI ; Junqiang FAN ; Guibin QIAO ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Zihao CHEN ; Hongxia TIAN ; Lunxu LIU ; Hecheng LI ; Xiaolong YAN ; Zongyang YU ; Zhenbin QIU ; Yihua SUN ; Jing HU ; Yuhang SHI ; Zhifei GUO ; Peng ZHANG ; Kezhong CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):848-856
With the continuous deepening of the concept of precision diagnosis and treatment for lung cancer, how to achieve higher efficiency and accuracy in the screening, diagnosis, and treatment pathways in clinical practice has become an important issue that urgently needs to be overcome. The current clinical difficulty lies in the fact that despite continuous advancements in imaging and molecular diagnostic technologies, there are still limitations in manual efficiency and subjective experience when it comes to massive data analysis and multi-scale feature extraction. Artificial intelligence (AI), especially algorithm systems based on deep learning, is an innovative technology capable of deeply empowering medical big data. This method utilizes algorithms such as convolutional neural networks, combined with radiomics, pathomics, and multi-modal data fusion analysis, demonstrating immense potential in early precise detection and benign-malignant differentiation of pulmonary nodules, digital pathological subtype recognition and non-invasive prediction of driver genes, precise 3D surgical planning and automatic delineation of radiotherapy target volumes, as well as dynamic risk warning during follow-up. This innovative technology provides a brand-new solution for realizing intelligent and individualized lung cancer diagnosis and treatment models. This consensus, based on the latest evidence from evidence-based medicine and combined with the development trends in the AI field and real-world clinical needs, was ultimately formed by gathering the consensus opinions of multidisciplinary experts in radiology, pathology, thoracic surgery, and other fields. The main content covers the application specifications of AI in the three core scenarios of lung cancer screening, diagnosis, and treatment, the technical standards for data collection and algorithm validation, as well as the ethical and regulatory challenges faced at the current stage. It aims to clarify the applicable boundaries of AI as a clinical auxiliary decision support tool, providing scientific guidance and standardized exploration directions for peers currently engaged in or planning to carry out AI-assisted clinical diagnosis, treatment, and translation of lung cancer.
3.Dynamic prediction of JC polyomavirus reactivation after kidney transplantation
Mengyao LI ; Chengfeng ZHANG ; Difei REN ; Xin LIANG ; Shuyu CHEN ; Yushi PENG ; Yanjie WANG ; Meng ZHANG ; Jian XU ; Zheng CHEN ; Yun MIAO ; Yibin WANG
Organ Transplantation 2026;17(4):635-643
Objective To construct a dynamic prediction model for JC polyomavirus (JCV) reactivation after kidney transplantation. Methods A retrospective analysis was conducted on the clinical data of 128 recipients who met the inclusion criteria and received kidney transplantation in Nanfang Hospital, Southern Medical University, from June 2021 to December 2024. Dynamic Cox regression and dynamic restricted mean survival time (RMST) regression based on the landmark method were adopted to establish the dynamic prediction models, and Monte Carlo cross-validation was used to evaluate model performance. Results The dynamic models could predict the incidence and onset time of JCV reactivation within the subsequent 3 months according to covariates at each landmark time point from the 1st to the 6th month after transplantation. Remuzzi score, body mass index and warm ischemia time were independent risk factors for JCV reactivation, while a history of urinary BK polyomavirus reactivation served as a protective factor. The median values of the area under the curve, C-index and Brier score of the dynamic Cox model were 0.873, 0.851 and 0.065 respectively, and the C-index of the dynamic RMST model was 0.829, all of which were superior to those of the static model. Conclusions The landmark-based dynamic models exhibit excellent predictive performance, which may integrate baseline data and post-transplant follow-up information to realize dynamic assessment of the risk and time window of JCV reactivation, thereby providing evidence for optimizing post-operative monitoring and individualized intervention strategies.
4.Research of Subtype A Caused by New A Allele Mutation
Li-Ping ZOU ; Fang QIU ; Jian-Shuo LIU ; Zhi-Peng WU ; Feng-Qing ZHANG ; Ying ZHU
Journal of Experimental Hematology 2025;33(6):1765-1768
Objective:In order to clarify the ABO phenotype and genotype,and explore the molecular biological mechanism,serological detection,genotyping and gene sequencing were performed on an upper gastrointestinal hemorrhage patient with inconsistent forward and reverse ABO blood typing.Methods:ABO forward and reverse blood typing,H antigen identification,capillary centrifugation test and salivary substance detection were performed by classical serological method,moreover,polymerase chain reaction-sequence specific primer(PCR-SSP)was used for ABO genotyping,ABO gene 1-7 exons were sequenced by Sanger analysis in order to identify mutation.Results:Mixed field agglutination with anti-A,anti-AB and no agglutination with anti-A1 were appeared in the forward typing tests,agglutination with B cells but no agglutination with A1 cells and O cells were appeared in the reverse typing tests.3+agglutination strength was showed with anti-H.In capillary centrifugation experiment,erythrocyte after isolation in proximal part and distal end had same strength of agglutination with anti-A.Substances A and H were detected in saliva.The patient was assigned an A3 phenotype according to serological characteristics.Sequencing results of ABO gene 1-7 exons showed c.261delG,c.467C>T,c.865A>G,in which,865A>G was the first discovered mutation,and this new mutation had been submitted to GenBank with accession number PP187306.Conclusion:A novel site mutation c.865A>G is reported in this study,and this new mutation can result in a replacement of Met with Val at residue 289(p.Met289Val)and lead to an A3 phenotype.
5.Prospective study on the association between lifestyles and the risk of type 2 diabetes in adult residents
Meng-ru HE ; Xiao-li XU ; Gen-ming ZHAO ; Xing LIU ; Hui-lin XU ; Dan-dan HE ; Yu-ping CHENG ; Yong-gen JIANG ; Qian PENG ; Jian-hua SHI ; Xiao-hua LIU
Fudan University Journal of Medical Sciences 2025;52(5):647-656,685
Objective To analyze the association between lifestyle and the risk of type 2 diabetes(T2D)among adult residents.Methods The data was sourced from the Shanghai Suburban Adult Cohort and Biobank.A total of 42 096 adult residents who had not developed T2D were recruited from four districts of Shanghai(Songjiang,Jiading,Minhang,and Xuhui)between 2016 and 2019.The follow-up ended on Feb 28,2023.A structured questionnaire was used to collect information on six lifestyle-related items,including smoking,alcohol consumption,BMI,waist circumference(WC),physical activity,and diet.The unhealthy lifestyle scores(UHLS)were calculated by counting the number of all the unhealthy lifestyle items,with a range of 0-6.New-onset T2D events diagnosed by physicians were obtained through the medical information system.Cox proportional hazards regression model and restricted cubic spline model were utilized to evaluate the association between unhealthy lifestyles and the risk of T2D incidence.Results About 28.1%of the participants led 4-6 unhealthy lifestyles.A total of 1 752 new T2D cases were identified during 218 513.4 person-years of follow-up.Analysis of single unhealthy lifestyle showed that abnormal WC(HR=1.5,95%CI:1.4-1.7)and abnormal BMI(HR=1.3,95%CI:1.2-1.5)were associated with an increased risk of T2D.Compared with individuals with a UHLS of 0-1,those with a UHLS of 3 and 4-6 had 30%(95%CI:1.1-1.6)and 50%(95%CI:1.2-1.8)higher risks of T2D,respectively.Each additional unhealthy lifestyle was associated with a 10%increase in T2D incidence risk(HR=1.1,95%CI:1.1-1.2).Conclusion The risk of T2D in adult residents increases with the cumulative number of unhealthy lifestyles.Adult residents with abnormal WC or BMI,or have three or more unhealthy lifestyles accumulated,will increase the risk of new-onset T2D.
6.Research on dry and wet durability of reusable surgical gowns
Ze-chen LIN ; Min WAN ; Yu-peng SUN ; Hui-jie SUN ; Jian-jun SUN ; Qing ZHANG ; Bo ZHANG ; An-ning LI ; Fu-xin DU
Chinese Medical Equipment Journal 2025;46(6):28-33
Objective To explore the changes of durability properties of reusable surgical gowns when used in dry and wet conditions.Methods Reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material were selected as test samples,and a Martindale abrasion and pilling tester was used as the basic test platform and modified to form fixtures suitable for the wet state environment.The reusable surgical gowns underwent abrasion experiments in wet and dry conditions to observe the changes in their fiber structure,and were subjected to water penetration resistance and swelling strength tests.Results Visually the reusable surgical gowns had few changes of the microscopic textile fiber structure in dry and wet conditions,and the gowns made of single-layer polyster fiber gained advantages over the outer layers of those of 3-layer composite material in abrasion resistance with the same friction cycles.In dry and wet conditions,the hydrostatic pressure values of the gowns of single-layer polyster fiber gradually decreased with the increase of the degree of abrasion,which were always lower than those of the gowns of 3-layer composite material;the swelling strength of the gowns of single-layer polyster fiber was always greater than that of the gowns of 3-layer composite material,which decreased with the deterioration of the wear more significantly than that of the gowns of 3-layer composite material.Conclusion The reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material have few differences in durability and protective properties at the early stages of ablation in dry and wet conditions.The durability of the gowns decreases as the degree of wear increases,while the trend of the decrease is slowing down until the fabric breaks down and completely loses its barrier effect.[Chinese Medical Equipment Journal,2025,46(6):28-33]
7.Research on dry and wet durability of reusable surgical gowns
Ze-chen LIN ; Min WAN ; Yu-peng SUN ; Hui-jie SUN ; Jian-jun SUN ; Qing ZHANG ; Bo ZHANG ; An-ning LI ; Fu-xin DU
Chinese Medical Equipment Journal 2025;46(6):28-33
Objective To explore the changes of durability properties of reusable surgical gowns when used in dry and wet conditions.Methods Reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material were selected as test samples,and a Martindale abrasion and pilling tester was used as the basic test platform and modified to form fixtures suitable for the wet state environment.The reusable surgical gowns underwent abrasion experiments in wet and dry conditions to observe the changes in their fiber structure,and were subjected to water penetration resistance and swelling strength tests.Results Visually the reusable surgical gowns had few changes of the microscopic textile fiber structure in dry and wet conditions,and the gowns made of single-layer polyster fiber gained advantages over the outer layers of those of 3-layer composite material in abrasion resistance with the same friction cycles.In dry and wet conditions,the hydrostatic pressure values of the gowns of single-layer polyster fiber gradually decreased with the increase of the degree of abrasion,which were always lower than those of the gowns of 3-layer composite material;the swelling strength of the gowns of single-layer polyster fiber was always greater than that of the gowns of 3-layer composite material,which decreased with the deterioration of the wear more significantly than that of the gowns of 3-layer composite material.Conclusion The reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material have few differences in durability and protective properties at the early stages of ablation in dry and wet conditions.The durability of the gowns decreases as the degree of wear increases,while the trend of the decrease is slowing down until the fabric breaks down and completely loses its barrier effect.[Chinese Medical Equipment Journal,2025,46(6):28-33]
8.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
9.Precise suctioning scheme for intravenous drug dispensing based on vial dispensing robot
Xian-tao QIN ; Tai-min LUO ; Li YANG ; Peng GAO ; Jian-rong CUI
Chinese Medical Equipment Journal 2025;46(9):45-51
Objective To propose a precise suctioning scheme for intravenous drug dispensing based on the vial dispensing robot to enhance the quality of finished infusion.Methods Six kinds of typical representative vial drugs were selected as the research objects,including pantoprazole sodium for injection,papaverine hydrochloride for injection,cefuroxime sodium for injection,Bozhi Glycopeptide Injection,Esomeprazole Sodium for Injection and Methylprednisolone Sodium Succinate for injection.The optimal suction speed was determined by studying the relationship between the size parameters of vials and the suction speed of robot dispensing,which was used to carry out drug dispensing with the vial dispensing robot to verify whether the minimum drug residue could be obtained with the speed.The drug residue was compared with that by manual dispensing.SPSS 24.0 and Excel 2021 were applied to statistical analysis.Results The optimal suction efficiency and minimized drug residue could be got with the depth of the syringe needle hole into the rubber plug(X)less than the height of the rubber plug(H)and the optimal suction speed(Vs)of 7.48 mm/s;the suction efficiency could be ensured without air drawn in when X not less than H and Vs ranging from 10.64 to 39.31 mm/s.The mean values of the drug residue by the robot were all lower than those by manual dispensing,with the differences being statistically significant(P<0.05).Conclusion The proposed scheme can be used for optimizing the parameters of the vial vial dispensing robot to obtain infusion solution with high stability and reliability,which promotes standardization and normalization of intravenous infusion dispensing process.[Chinese Medical Equipment Journal,2025,46(9):45-51]
10.Finite element analysis of application of variable angle screws in posterolateral tibial plateau fractures
Zhenghui HU ; Wen ZHANG ; Hongquan HENG ; Weizhi REN ; Chenying WU ; Zenghui GU ; Jian PENG ; Liubing LI ; Wei XU
Chinese Journal of Tissue Engineering Research 2025;29(27):5735-5742
BACKGROUND:During the treatment of posterolateral tibial plateau fractures through the fibular head approach,the gap between the fibular head and the lateral plateau cannot accommodate the posterior placement of a plate for all patients.OBJECTIVE:To analyze,via finite element analysis,the differences in fixation strength resulting from varying the angles and quantities of horizontal arm variable angle screws in the plate during the treatment of posterolateral tibial plateau fractures through the fibular head approach.METHODS:A finite element model was established based on CT images of the knee to ankle joints of a 30-year-old healthy adult male volunteer.The models were divided into two categories:posteriorly placed group and non-posteriorly placed group based on whether the lateral locking compression plate was posteriorly placed.The posteriorly placed group was further subdivided into groups A-D based on the offset angle of the two variable angle screws(0°,5°,10°,and 15°).The non-posteriorly placed group was subdivided into groups E and F based on offset angles(0° and 15°).Finite element analysis was used to evaluate the von Mises stress distribution,maximum von Mises stress,and compressive displacement under loads of 250,500,and 750 N,exploring the mechanical differences between the groups.RESULTS AND CONCLUSION:(1)Finite element analysis results showed that under a 750 N load,the maximum compressive displacement trend of the internal fixation device was D<B=C=F<A<E.The trend for maximum von Mises stress was B<C<A<D<F<E.The trend for maximum compressive displacement on the bone was C=D<B<A<F<E,and for maximum von Mises stress,it was B<C<A<F<D<E.The displacement and stress trends for the six models were similar under loads ranging from 250 N to 750 N.(2)These results suggest that for posterolateral tibial plateau fractures fixed through the fibular head approach,posterior placement of the plate should aim to accommodate two screws.If only one screw can be fixed during surgery,variable angle screws should be offset in the range of 0-15° to increase the probability of securing two screws.

Result Analysis
Print
Save
E-mail