1.Morphological identification of Lispe pumila (Diptera: Muscidae)
Shun-fang HUANG ; Ying SU ; Zi-dong CHENG ; Guo-sheng LIAN ; Ming-jian KE
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):141-143
In March 2024, three male and two female specimens of the genus Lispe were intercepted on cargo ships inbound for Wan Zai Port under Gongbei Customs. Based on morphological characteristics and molecular analysis, the specimens were identified as Lispe pumila. In this study, we describe the morphological features, diagnostic characteristics, and geographical distribution of L. pumila, with the aim of providing a reference for the identification of this species when intercepted at ports.
2.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
3.Construction of management index system for rational drug use of key monitoring drugs
Mingxiong ZHANG ; Wanying QIN ; Jian HUANG ; Dan WANG ; Li LI ; Yinghui BU ; Ming YAN ; Kejia LI
China Pharmacy 2025;36(7):784-788
OBJECTIVE To establish management index system for rational drug use of key monitoring drugs, and provide reference for the management of key monitoring drugs in the hospitals. METHODS First, the management index system for rational drug use of key monitoring drugs was drafted by collecting the evidence from related medical literature. Next, using a modified Delphi method, twenty experienced experts from the fields of pharmacy, medical practice, healthcare insurance, and finance were selected to participate in two rounds of questionnaire consultations. Based on the expert enthusiasm coefficient, authority coefficient, degree of opinion concentration, and degree of coordination, the final indicators were determined to establish a management index system for rational drug use of key monitored drugs in medical institutions. RESULTS The expert enthusiasm coefficients reached 100% in both rounds of consultation. In first-level, second-level and third-level indicators, the authority coefficients of experts were 0.89, 0.86 and 0.87, and coordination coefficients of the experts in importance score were 0.300 (P< 0.05), 0.125 (P<0.05) and 0.139 (P<0.05), respectively. The average score for the importance of all indicators reached over 3.5, in which the full score ratio ranged from 35% to 100%. Except that the variation coefficient of a third-level indicator “number of specifications purchased for key monitored drugs” was 0.26, the variation coefficients of rest indicators were less than or equal to 0.25. Based on the results of expert consultation, final version of the management index system established in this study, including two first-level indicators (drug procurement and use, and rational drug use), five second-level indicators (such as the accessibility, cost-effectiveness) and twenty third-level indicators (such as the number of specifications purchased for key monitored drugs, the increase in the cost of key monitored drugs). CONCLUSIONS The management index system established in this study possesses high reliability and strong operability, and may provide a reference for the management of key monitoring drugs in the hospitals.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model
Honghu SONG ; Zun PIAO ; Guomin HUANG ; Jian SHI ; Ming CHEN ; Xiaoyan HUANG
Chinese Journal of Radiological Medicine and Protection 2025;45(5):416-422
Objective:To investigate the impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model (MKM) used in carbon-ion radiotherapy.Methods:The saturation-corrected specific energy ( ) of monoenergetic carbon ions was calculated using the Kiefer-Chatterjee (K-C) track structure model. Correction curve f(LET) was derived from experimental data on relative biological effectiveness (RBE) (RBE DSB-LET) defined based on the double-strand DNA break of the Chinese hamster ovary (CHO) and Fibroblast cell lines irradiated using carbon ions with varying linear energy transfer (LET) values. Then, based on the MKM, the D10-LET curves, as well as α and β databases, of the CHO and Fibroblast cell lines with varying radiosensitivity were determined. Results:Compared to the clinically applied MKM, the predicted D10 after correction while accounting for cell line radiosensitivity agreed better with experimental D10 values of the CHO and Fibroblast cell lines. Specifically, compared to experimental values in the literature, the D10 values calculated in the study and determined using the MKM showed mean squared errors (MSEs) of 0.04 and 0.71, for the CHO cell line and 0.35 and 0.55, respectively, for the Fibroblast cell line. For monoenergetic carbon ions with varying LET values, the calculated α and β values generally increased with cellular radiosensitivity. Conclusions:Incorporating cellular radiosensitivity into the MKM framework serves as a more specific method for RBE assessment while also providing a reference for advancing MKM applications and achieving the fine-scale calculations of RBE in carbon-ion radiotherapy.
8.Research on low-dose CT image denoising method based on improved Corediff model
Li-mei SONG ; Hang WU ; Yi-feng HUANG ; Qiang WANG ; Guan-jun LIU ; Feng CHEN ; Ming YU ; Jian-kun SHEN
Chinese Medical Equipment Journal 2025;46(5):9-13
Objective To propose a low-dose CT image denoising method based on an improved Corediff model to recover the detailed features of the image and enhance the image quality.Methods An RS-Corediff model was established by modifying the key component U-Net network of the Corediff model.Firstly,the residual module was introduced in the network input stage for feature extraction;secondly,a new downsampling module was designed in the U-Net network encoder,which learned the semantic information of the feature map by convolution and maintained the learning state during the downsampling process so as to fully extract the image features;thirdly,the feature splicing processing was used to further enhance the learning effect during the upsampling process of the U-Net network decoder;finally,the convolutional kernel size was modified to adjust the sensory field during the convolutional process of the whole U-Net network structure so as to obtain rich features.The RS-Corediff model was compared with the residual encoder-decoder convolutional neural network(RED-CNN)model and the Corediff model on the public dataset AAPM 2016 in order to verify its effectiveness for low-dose CT image denoising.Results The RS-Corediff model gained advantages over the RED-CNN and Corediff models with a peak signal-to-noise ratio(PSNR)of 41.269 8,structural similarity(SSIM)of 0.953 4 and root mean square error(RMSE)of 17.568 7.Conclusion The proposed method effectively preserves the texture and details of low-dose CT images during the denoising process to improve the overall quality of the images.[Chinese Medical Equipment Journal,2025,46(5):9-13]
9.Research on low-dose CT image denoising method based on improved Corediff model
Li-mei SONG ; Hang WU ; Yi-feng HUANG ; Qiang WANG ; Guan-jun LIU ; Feng CHEN ; Ming YU ; Jian-kun SHEN
Chinese Medical Equipment Journal 2025;46(5):9-13
Objective To propose a low-dose CT image denoising method based on an improved Corediff model to recover the detailed features of the image and enhance the image quality.Methods An RS-Corediff model was established by modifying the key component U-Net network of the Corediff model.Firstly,the residual module was introduced in the network input stage for feature extraction;secondly,a new downsampling module was designed in the U-Net network encoder,which learned the semantic information of the feature map by convolution and maintained the learning state during the downsampling process so as to fully extract the image features;thirdly,the feature splicing processing was used to further enhance the learning effect during the upsampling process of the U-Net network decoder;finally,the convolutional kernel size was modified to adjust the sensory field during the convolutional process of the whole U-Net network structure so as to obtain rich features.The RS-Corediff model was compared with the residual encoder-decoder convolutional neural network(RED-CNN)model and the Corediff model on the public dataset AAPM 2016 in order to verify its effectiveness for low-dose CT image denoising.Results The RS-Corediff model gained advantages over the RED-CNN and Corediff models with a peak signal-to-noise ratio(PSNR)of 41.269 8,structural similarity(SSIM)of 0.953 4 and root mean square error(RMSE)of 17.568 7.Conclusion The proposed method effectively preserves the texture and details of low-dose CT images during the denoising process to improve the overall quality of the images.[Chinese Medical Equipment Journal,2025,46(5):9-13]
10.Impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model
Honghu SONG ; Zun PIAO ; Guomin HUANG ; Jian SHI ; Ming CHEN ; Xiaoyan HUANG
Chinese Journal of Radiological Medicine and Protection 2025;45(5):416-422
Objective:To investigate the impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model (MKM) used in carbon-ion radiotherapy.Methods:The saturation-corrected specific energy ( ) of monoenergetic carbon ions was calculated using the Kiefer-Chatterjee (K-C) track structure model. Correction curve f(LET) was derived from experimental data on relative biological effectiveness (RBE) (RBE DSB-LET) defined based on the double-strand DNA break of the Chinese hamster ovary (CHO) and Fibroblast cell lines irradiated using carbon ions with varying linear energy transfer (LET) values. Then, based on the MKM, the D10-LET curves, as well as α and β databases, of the CHO and Fibroblast cell lines with varying radiosensitivity were determined. Results:Compared to the clinically applied MKM, the predicted D10 after correction while accounting for cell line radiosensitivity agreed better with experimental D10 values of the CHO and Fibroblast cell lines. Specifically, compared to experimental values in the literature, the D10 values calculated in the study and determined using the MKM showed mean squared errors (MSEs) of 0.04 and 0.71, for the CHO cell line and 0.35 and 0.55, respectively, for the Fibroblast cell line. For monoenergetic carbon ions with varying LET values, the calculated α and β values generally increased with cellular radiosensitivity. Conclusions:Incorporating cellular radiosensitivity into the MKM framework serves as a more specific method for RBE assessment while also providing a reference for advancing MKM applications and achieving the fine-scale calculations of RBE in carbon-ion radiotherapy.


Result Analysis
Print
Save
E-mail