1.Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis
Jian LIU ; Hongchun ZHANG ; Chengxiang WANG ; Hongsheng CUI ; Xia CUI ; Shunan ZHANG ; Daowen YANG ; Cuiling FENG ; Yubo GUO ; Zengtao SUN ; Huiyong ZHANG ; Guangxi LI ; Qing MIAO ; Sumei WANG ; Liqing SHI ; Hongjun YANG ; Ting LIU ; Fangbo ZHANG ; Sheng CHEN ; Wei CHEN ; Hai WANG ; Lin LIN ; Nini QU ; Lei WU ; Dengshan WU ; Yafeng LIU ; Wenyan ZHANG ; Yueying ZHANG ; Yongfen FAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(4):182-188
The Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis (GS/CACM 337-2023) was released by the China Association of Chinese Medicine on December 13th, 2023. This expert consensus was developed by experts in methodology, pharmacy, and Chinese medicine in strict accordance with the development requirements of the China Association of Chinese Medicine (CACM) and based on the latest medical evidence and the clinical medication experience of well-known experts in the fields of respiratory medicine (pulmonary diseases) and pediatrics. This expert consensus defines the application of Qinbaohong Zhike oral liquid in the treatment of cough and excessive sputum caused by phlegm-heat obstructing lung, acute bronchitis, and acute attack of chronic bronchitis from the aspects of applicable populations, efficacy evaluation, usage, dosage, drug combination, and safety. It is expected to guide the rational drug use in medical and health institutions, give full play to the unique value of Qinbaohong Zhike oral liquid, and vigorously promote the inheritance and innovation of Chinese patent medicines.
2.A case of acute inferior myocardial infarction and cardiogenic shock with abnormal right coronary artery
Yu-Hai ZOU ; Ai-Min LI ; Jian-Xin HE ; Jin-Xia ZHANG
Chinese Journal of Interventional Cardiology 2024;32(9):538-540
Aberration of the right coronary artery from the left anterior descending is a very rare congenital anomaly.The anomalous the right coronary artery,as a branch of the septal branch,has not been reported clinically.This article reports such rare case.A 52-year-old female was admitted due to"sudden chest pain and confusion for 4 hours".The ECG showed that the ST-segment of leads(V1-V4,V3R,V4R and V5R)were elevated about 0.1-0.3 mVThe blood pressure was 63/53 mmHg.She was diagnosed as cardiogenic shock second to acute anterior and right ventricular ST-segment elevation myocardial infarction.Emergency coronary angiography was performed after intra-aortic ballon pump was implanted to assist circulation.During the treatment of the culprit vessel,it was accidentally found that the right coronary artery,as a branch vessel,originated from the ostium of the second septal branch of the anterior descending artery.
3.Clinical Features and Prognosis of Patients with CD5+Diffuse Large B-Cell Lymphoma
Xiu-Juan HUANG ; Jian YANG ; Xiao-Fang WEI ; Yuan FU ; Yang-Yang ZHAO ; Ming-Xia CHENG ; Qing-Fen LI ; Hai-Long YAN ; You-Fan FENG
Journal of Experimental Hematology 2024;32(3):750-755
Objective:To analyze the clinical characteristics and prognosis of patients with CD5+diffuse large B-cell lymphoma(DLBCL).Methods:The clinical data of 161 newly treated DLBCL patients in Gansu Provincial Hospital from January 2013 to January 2020 were retrospectively analyzed.According to CD5 expression,the patients were divided into CD5+group and CD5-group.The clinical characteristics and prognosis of the two groups were statistically analyzed.Results:The median age of patients in CD5+group was 62 years,which was higher than 56 years in CD5-group(P=0.048).The proportion of women in CD5+group was 62.96%,which was significantly higher than 41.79%in CD5-group(P=0.043).The proportion of patients with IPI score>2 in CD5+group was 62.96%,which was higher than 40.30%in CD5-group(P=0.031).Survival analysis showed that the median overall survival and progression-free survival time of patients in CD5+group were 27(3-77)and 31(3-76)months,respectively,which were both shorter than 30(5-84)and 32.5(4-83)months in CD5-group(P=0.047,P=0.026).Univariate analysis showed that advanced age,positive CD5 expression,triple or double hit at initial diagnosis,high IPI score and no use of rituximab during chemotherapy were risk factors for the prognosis of DLBCL patients.Further Cox multivariate regression analysis showed that these factors were also independent risk factors except for advanced age.Conclusion:CD5+DLBCL patients have a worse prognosis than CD5-DLBCL patients.Such patients are more common in females,with advanced age and high IPI score,which is a special subtype of DLBCL.
4.The Prognostic Value of Del(1p32)in Patients with Newly Diagnosed Multiple Myeloma
Rui GUO ; Xu-Xing SHEN ; Yuan XIA ; Yuan-Yuan JIN ; Jian-Yong LI ; Li-Juan CHEN ; Hai-Rong QIU
Journal of Experimental Hematology 2024;32(3):768-773
Objective:To analyze the prognostic value of del(1p32)in patients with newly diagnosed multiple myeloma(MM).Methods:The clinical data of 341 newly diagnosed MM attended in Jiangsu Province Hospital were retrospective analyzed.Clinical characteristic combined with genetic features,especially del(1p32),were analyzed for survival and prognostic of patients.Results:Among the 341 patients with newly diagnosed MM,24(7.0%)patients were del(1p32)positive.The progression-free survival(PFS)and overall survival(OS)were significantly shorter in MM patients with del(1p3 2)than those without de1(1p32)(PFS:P<0.001;OS:P<0.001).The COX proportional-hazards model showed that del(1 p32)was an independent risk factor for PFS and OS of patients with MM.The patients with both 1q21 gain/amplification and del(1p32),as"double-hit chromosome 1",have worse prognosis than those with only 1q21 gain/amplification or only del(1 p32)(PFS:P<0.001;OS:P<0.001).Conclusion:Del(1p32)is an independent risk factor for PFS and OS of patients with MM.Del(1p32)detection should be widely used in the prognostic analysis for newly diagnosed MM patients.
5.Development of biological safety protection third-level laboratory based on folding-modular shelters
Si-Qing ZHAO ; Jian-Qiao XIA ; Zhong-Jie SUN ; Kang OUYANG ; Xiao-Jun JIN ; Kang-Li ZHOU ; Wei XIE ; Hai-Yang LI ; Da-Peng JIANG ; Yan-Yan GAO ; Bei SUN
Chinese Medical Equipment Journal 2024;45(3):41-46
Objective To develop a biological safety protection third-level(BSL-3)laboratory based on folding-modular shelters to solve the problems of the existing laboratories in space and function expansion,large-scale deployment and low-cost transportation.Methods The BSL-3 laboratory was composed of a folding combined shelter module,a ventilation and purification module,a power supply and distribution module,a monitoring and communication module,a control system module and an equipment module.The folding combined shelter module used a leveling base frame as the foundation and a lightweight panel as the enclosure mechanism,and was divided into an auxiliary area and a protection protected area;the ventilation and purification module was made up of an air supply unit and an air exhaust unit,the air supply unit was integrated with a fresh-air air conditioner and the exhaust unit was equipped with a main fan,a standby fan and a bag in/bag out filter;the control system module adopted a supervision mode of decentralized control and centralized management,which executed communication with the data server as the center and Profinet protocol and MODBUS-TCP.Results The BSL-3 laboratory proved to meet the requirements of relevant standards in internal microenvironment,airflow direction,airtightness,working condition and disinfection effect.Conclusion The BSL-3 laboratory is compatible with large-scale transport and deployment and facilitates reliable and safe experiments for epidemic prevention and control and cross-regional support.[Chinese Medical Equipment Journal,2024,45(3):41-46]
6.Development of ventilation system for enhanced mobile biosafety level-2 laboratory
Jian-Qiao XIA ; Kang OU-YANG ; Hai-Yang LI
Chinese Medical Equipment Journal 2024;45(7):29-34
Objective To develop a ventilation system for the enhaned mobile biosafety level-2(BSL-2)laboratory to control the dispersed aerosol within the laboratory effectively.Methods A ventilation system for the enhanced mobile biosafety level-2 laboratory was designed with the concept of full fresh air ventilation,which realized air supply with 3-stage filtration and constant air volume control,and air exhaust with 1-stage high-efficiency filtration and variable air volume control.The buffer room had the layout of upside air supply and upside exhaust,with the air supply and exhaust equipment integrated into the ceiling;the experimental room had the layout of diagonally upside air supply and diagonally downside exhaust.Computa-tional fluid dynamics(CFD)software was used to analyze the airflow organization,temperature field and velocity field at 0°,30°,45°,60° and 90° air supply angles in order to verify the feasibility of the ventilation system design,and the distributions of aerosol concentration in the experimental room at different air supply angles were simulated to determine the optimal air supply angle.Results Investigations in terms of airflow organization,temperature field,velocity field and aerosol dispersion control showed in case of 60° air supply angel the enhanced mobile BSL-2 laboratory behaved the best and its core indexes all met the requirements of GB 27421-2015 Mobile laboratories—Generalrequirements for biosafety and T/CESC 662-2020 Architectural technical standard for BSL-2 laboratory in medical facilities including the number of air changes,static pressure difference,temperature and humidity,cleanliness and airflow direction.Conclusion Considerations have to be taken on the locations of supply and exhaust outlets,the facility layout and air supply angle when the enhanced mobile BSL-2 laboratory is designed so as to enhance the biosafety of the protective area.[Chinese Medical Equipment Journal,2024,45(7):29-34]
7.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
8.Clinical trial of pegylated losenatide in the treatment of obese patients with type 2 diabetes mellitus undergoing axial gastrectomy
Jing-Feng GU ; Hai-Xia LIU ; Feng FENG ; Jian ZHANG ; Dong-Yang XING ; Hao-Wen GAO ; Gui-Qi WANG
The Chinese Journal of Clinical Pharmacology 2024;40(3):330-334
Objective To observe the effects of pegylated losenatide injection combined with metformin tablets on serum metabolism,lipid levels and intestinal flora in obese type 2 diabetes mellitus(T2DM)patients after axial gastrectomy.Methods Obese T2DM patients who underwent axial gastrectomy were divided into treatment group and control group by cohort methods.The control group was treated with metformin hydrochloride tablet 0.5 g orally,tid.The treatment group was treated by subcutaneous injection of pegylated losenatide injection 0.2 mg once a week on the basis of control group.Both groups were treated continuously for 3 months.Body mass index(BMI),serum metabolic indexes,blood lipid levels,blood glucose levels,intestinal flora and adverse drug reactions were compared between the two groups.Results In this study,a total of 70 subjects were included in the treatment group,and 50 subjects were included in the control group.After three months of treatment,the BMI indices of the treatment and control groups were(26.35±2.36)and(29.34±3.59)kg·m-2,respectively;the glutathione peroxidase levels were(192.42±13.18)and(134.27±12.86)U;interleukin-6 levels were(6.14±1.78)and(7.65±2.09)μg·L-1;fasting blood glucose levels were(5.36±0.41)and(7.43±0.78)mmol·L-1;total cholesterol levels were(2.55±0.67)and(3.47±0.79)mmol·L-1 for the treatment and control groups,respectively.The levels of Bifidobacteria,Bacteroides,Lactobacilli,Enterobacteria,and Enterococci in the treatment group were(8.79±1.36),(9.62±1.37),(6.74±2.15),(7.98±0.61),and(7.23±1.29)logN·g-1,respectively;in the control group,these levels were(7.98±1.79),(8.13±1.45),(5.71±2.41),(9.21±0.88),and(8.15±1.54)logN·g-1.The differences in the above indicators between the treatment and control groups were statistically significant(all P<0.05).The main adverse drug reactions in the treatment group included nausea,headache,dizziness,elevated blood pressure,and indigestion.In the control group,the main adverse drug reactions were nausea,headache,and indigestion.The total incidence of adverse drug reactions in the treatment and control groups was 8.57%and 6.00%,respectively,with no statistically significant difference(P>0.05).Conclusion Pegylated losenatide injection combined with metformin tablets has a significant effect on axial gastrectomy in obese type 2 diabetes patients.
9.Investigation of Adductive Characteristics of Sulfur Mustards with Active Thiols
Meng-Yao ZHANG ; Jin-Long CAI ; Meng-Qiang GONG ; Bin XU ; Jian-Feng WU ; Hai-Xia WU ; Jian-Wei XIE
Chinese Journal of Analytical Chemistry 2024;52(7):995-1003,中插30-中插34
An analytical method based on ultra high performance liquid chromatography-high resolution tandem mass spectrometry(UHPLC-HRMS/MS)and high performance liquid chromatography-triple quadrupole mass spectrometry(HPLC-TQ MS)was established to reveal the characteristics of various sulfur mustard analogs with different active thiol molecules in CWC Schedule 1.A.04.Firstly,the toxic agents were prepared by micro-directed synthesis,and then the differences of the reactivity and abundance of formed adducts between different sulfur mustards and glutathione(GSH),cysteine(Cys)and N-acetylcysteine(NAC)in incubation solution,plasma and cell were investigated,respectively.The results indicated that all target sulfur mustards could react with three kinds of thiol molecules.The content of Cys and sulfur mustard adducts in plasma was higher than that of GSH and sulfur mustard adducts,while NAC and sulfur mustard adducts might have fewer types of adducts due to low content or poor mass spectrometry response.Additionally,the content of GSH and sulfur mustard adducts in exposed cells was higher than that of Cys,which should be due to the significant difference in the content of thiol molecules in plasma and cells.
10.Advances of Metal-Organic Framework Composites in Electrochemical Detection of Environmental Pollutants
Jian-Xia GU ; Hai-Xuan WANG ; Jing-Ting HE ; Jian BAI ; Lu-Yun MA
Chinese Journal of Analytical Chemistry 2024;52(8):1061-1071
With the continuous development of science and technology,environmental pollution has become increasingly severe,which makes environmental monitoring crucial.In recent years,electrochemical sensing strategy has attracted wide attention due to its advantages such as low cost,easy operation and fast detection speed.However,the detection performance still faces many challenges such as low sensitivity,high limit of detection and poor selectivity.Metal-organic frameworks(MOFs)is a kind of ordered network porous crystal formed by the coordination bond of organic ligands and metal ions/ion clusters,which can be used to prepare high-performance electrode materials for construction of electrochemical sensors because of their characteristics of large specific surface area,adjustable pore size and diverse structure.However,the poor conductivity and stability of MOFs result in poor electrochemical detection performance,which seriously limits their extensive applications in the field of electrochemistry.Combining MOFs with other functional materials can not only overcome the inherent defects of MOFs but also have the superior properties of both MOFs and functional materials,and the synergistic effect between MOFs and functional materials is conducive to improving the detection performance.Therefore,MOFs composites have been widely used in the electrochemical detection of environmental pollutants.This paper reviewed the applications progress of electrochemical sensors based on MOFs composites(MOFs combine with carbon materials,conductive polymers,metal nanoparticles or MOFs)in detection of environmental pollutants(Pesticides,heavy metal ions,phenolic compounds and nitrites)in the past five years.The prospects and challenges of electrochemical sensors based on MOFs composites for detection of environmental pollutants were also discussed.

Result Analysis
Print
Save
E-mail