1.Processing technology of calcined Magnetitum based on concept of QbD and its XRD characteristic spectra.
De-Wen ZENG ; Jing-Wei ZHOU ; Tian-Xing HE ; Yu-Mei CHEN ; Huan-Huan XU ; Jian FENG ; Yue YANG ; Xin CHEN ; Jia-Liang ZOU ; Lin CHEN ; Hong-Ping CHEN ; Shi-Lin CHEN ; Yuan HU ; You-Ping LIU
China Journal of Chinese Materia Medica 2025;50(9):2391-2403
Guided by the concept of quality by design(QbD), this study optimizes the calcination and quenching process of calcined Magnetitum and establishes the XRD characteristic spectra of calcined Magnetitum, providing a scientific basis for the formulation of quality standards. Based on the processing methods and quality requirements of Magnetitum in the Chinese Pharmacopoeia, the critical process parameters(CPPs) identified were calcination temperature, calcination time, particle size, laying thickness, and the number of vinegar quenching cycles. The critical quality attributes(CQAs) included Fe mass fraction, Fe~(2+) dissolution, and surface color. The weight coefficients were determined by combining Analytic Hierarchy Process(AHP) and the criteria importance though intercrieria correlation(CRITIC) method, and the calcination process was optimized using orthogonal experimentation. Surface color was selected as a CQA, and based on the principle of color value, the surface color of calcined Magnetitum was objectively quantified. The vinegar quenching process was then optimized to determine the best processing conditions. X-ray diffraction(XRD) was used to establish the characteristic spectra of calcined Magnetitum, and methods such as similarity evaluation, cluster analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) were used to evaluate the quality of the spectra. The optimized calcined Magnetitum preparation process was found to be calcination at 750 ℃ for 1 h, with a laying thickness of 4 cm, a particle size of 0.4-0.8 cm, and one vinegar quenching cycle(Magnetitum-vinegar ratio 10∶3), which was stable and feasible. The XRD characteristic spectra analysis method, featuring 9 common peaks as fingerprint information, was established. The average correlation coefficient ranged from 0.839 5-0.988 1, and the average angle cosine ranged from 0.914 4 to 0.995 6, indicating good similarity. Cluster analysis results showed that Magnetitum and calcined Magnetitum could be grouped together, with similar compositions. OPLS-DA discriminant analysis identified three key characteristic peaks, with Fe_2O_3 being the distinguishing component between the two. The final optimized processing method is stable and feasible, and the XRD characteristic spectra of calcined Magnetitum was initially established, providing a reference for subsequent quality control and the formulation of quality standards for calcined Magnetitum.
X-Ray Diffraction/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Particle Size
2.Performance assessment of computed tomographic angiography fractional flow reserve using deep learning: SMART trial summary.
Wei ZHANG ; You-Bing YIN ; Zhi-Qiang WANG ; Ying-Xin ZHAO ; Dong-Mei SHI ; Yong-He GUO ; Zhi-Ming ZHOU ; Zhi-Jian WANG ; Shi-Wei YANG ; De-An JIA ; Li-Xia YANG ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(9):793-801
BACKGROUND:
Non-invasive computed tomography angiography (CTA)-based fractional flow reserve (CT-FFR) could become a gatekeeper to invasive coronary angiography. Deep learning (DL)-based CT-FFR has shown promise when compared to invasive FFR. To evaluate the performance of a DL-based CT-FFR technique, DeepVessel FFR (DVFFR).
METHODS:
This retrospective study was designed for iScheMia Assessment based on a Retrospective, single-center Trial of CT-FFR (SMART). Patients suspected of stable coronary artery disease (CAD) and undergoing both CTA and invasive FFR examinations were consecutively selected from the Beijing Anzhen Hospital between January 1, 2016 to December 30, 2018. FFR obtained during invasive coronary angiography was used as the reference standard. DVFFR was calculated blindly using a DL-based CT-FFR approach that utilized the complete tree structure of the coronary arteries.
RESULTS:
Three hundred and thirty nine patients (60.5 ±10.0 years and 209 men) and 414 vessels with direct invasive FFR were included in the analysis. At per-vessel level, sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of DVFFR were 94.7%, 88.6%, 90.8%, 82.7%, and 96.7%, respectively. The area under the receiver operating characteristics curve (AUC) was 0.95 for DVFFR and 0.56 for CTA-based assessment with a significant difference (P < 0.0001). At patient level, sensitivity, specificity, accuracy, PPV and NPV of DVFFR were 93.8%, 88.0%, 90.3%, 83.0%, and 95.8%, respectively. The computation for DVFFR was fast with the average time of 22.5 ± 1.9 s.
CONCLUSIONS
The results demonstrate that DVFFR was able to evaluate lesion hemodynamic significance accurately and effectively with improved diagnostic performance over CTA alone. Coronary artery disease (CAD) is a critical disease in which coronary artery luminal narrowing may result in myocardial ischemia. Early and effective assessment of myocardial ischemia is essential for optimal treatment planning so as to improve the quality of life and reduce medical costs.
3.Localization and anatomical measurement of lateral compression Ⅱscrew guide needle insertion point for pelvic fracture
Yong-Zheng CHEN ; Zhen-Hua HU ; Shao-Juan LI ; Xia-Cun LIANG ; Li-Kang HOU ; Shu-Liang ZHU ; Xin-Ying BAI ; Jin-Jian HE ; De-Meng YANG ; Zhi-Guo CHEN
Acta Anatomica Sinica 2024;55(6):728-733
Objective To measure the distance between the lateral compression Ⅱ(LC-Ⅱ)screw guide needle and the surrounding important structures around the anterior inferior iliac spine in pelvic fractures and to locate the needle point,so as to provide anatomical reference for clinical nail placement.Methods Totally 40 adult gross specimens of embalming were implanted with LC-Ⅱ screw guide needle under the surveillance of C-arm machine,and the specimens were dissected.The shortest distance between the insertion point and the lateral femoral cutaneous nerve,femoral nerve,femoral artery,femoral vein,anterior superior iliac spine and inguinal ligament was measured.The triangle was constructed between the insertion point,anterior superior iliac spine and inguinal ligament,and the exact location of the entry point was calculated.Results The average distance between the insertion point of the male needle and the femoral vein was(50.67±7.29)mm>the anterior superior iliac spine(43.83±7.58)mm>the femoral artery(38.35±6.63)mm>the femoral nerve(31.17±1.67)mm=the inguinal ligament(28.69±6.59)mm>the lateral femoral cutaneous nerve(7.98±3.81)mm.The mean distance between the insertion point of the female needle and the anterior superior iliac spine was(45.28±7.07)mm=femoral vein(43.72±6.89)mm>femoral artery(33.76±6.33)mm>femoral nerve(25.66±6.46)mm=inguinal ligament(23.22±5.00)mm>lateral femoral cutaneous nerve(8.97±4.76)mm.The projection distance of the entry point was 31.77 mm for men and 38.41 mm for women.The Angle b was 42.81°for men and 31.71° for women.Conclusion The lateral femoral cutaneous nerve is most vulnerable to injury when LC-Ⅱ screw is inserted,and the risk of injury has nothing to do with sex.The insertion point positioning method a and b made LC-Ⅱ screw placement quickly,safely and accurately,and reduced fluoroscopy time and frequency.
4.Anti-COVID-19 mechanism of Anoectochilus roxburghii liquid based on network pharmacology and molecular docking
Jin ZHU ; Yan-bin WU ; De-fu HUANG ; Bing-ke BAI ; Xu-hui HE ; Dan JIA ; Cheng-jian ZHENG
Acta Pharmaceutica Sinica 2024;59(3):633-642
italic>Anoectochilus roxburghii liquid (spray, a hospital preparation of Wu Mengchao Hepatobiliary Hospital of Fujian Medical University) has shown a good clinical treatment effect during the COVID-19 pandemic, but its material basis and mechanism of action are still unclear. In this study, network pharmacology and molecular docking methods were used to predict the molecular mechanism of
5.Nanomaterial-based Therapeutics for Biofilm-generated Bacterial Infections
Zhuo-Jun HE ; Yu-Ying CHEN ; Yang ZHOU ; Gui-Qin DAI ; De-Liang LIU ; Meng-De LIU ; Jian-Hui GAO ; Ze CHEN ; Jia-Yu DENG ; Guang-Yan LIANG ; Li WEI ; Peng-Fei ZHAO ; Hong-Zhou LU ; Ming-Bin ZHENG
Progress in Biochemistry and Biophysics 2024;51(7):1604-1617
Bacterial biofilms gave rise to persistent infections and multi-organ failure, thereby posing a serious threat to human health. Biofilms were formed by cross-linking of hydrophobic extracellular polymeric substances (EPS), such as proteins, polysaccharides, and eDNA, which were synthesized by bacteria themselves after adhesion and colonization on biological surfaces. They had the characteristics of dense structure, high adhesiveness and low drug permeability, and had been found in many human organs or tissues, such as the brain, heart, liver, spleen, lungs, kidneys, gastrointestinal tract, and skeleton. By releasing pro-inflammatory bacterial metabolites including endotoxins, exotoxins and interleukin, biofilms stimulated the body’s immune system to secrete inflammatory factors. These factors triggered local inflammation and chronic infections. Those were the key reason for the failure of traditional clinical drug therapy for infectious diseases.In order to cope with the increasingly severe drug-resistant infections, it was urgent to develop new therapeutic strategies for bacterial-biofilm eradication and anti-bacterial infections. Based on the nanoscale structure and biocompatible activity, nanobiomaterials had the advantages of specific targeting, intelligent delivery, high drug loading and low toxicity, which could realize efficient intervention and precise treatment of drug-resistant bacterial biofilms. This paper highlighted multiple strategies of biofilms eradication based on nanobiomaterials. For example, nanobiomaterials combined with EPS degrading enzymes could be used for targeted hydrolysis of bacterial biofilms, and effectively increased the drug enrichment within biofilms. By loading quorum sensing inhibitors, nanotechnology was also an effective strategy for eradicating bacterial biofilms and recovering the infectious symptoms. Nanobiomaterials could intervene the bacterial metabolism and break the bacterial survival homeostasis by blocking the uptake of nutrients. Moreover, energy-driven micro-nano robotics had shown excellent performance in active delivery and biofilm eradication. Micro-nano robots could penetrate physiological barriers by exogenous or endogenous driving modes such as by biological or chemical methods, ultrasound, and magnetic field, and deliver drugs to the infection sites accurately. Achieving this using conventional drugs was difficult. Overall, the paper described the biological properties and drug-resistant molecular mechanisms of bacterial biofilms, and highlighted therapeutic strategies from different perspectives by nanobiomaterials, such as dispersing bacterial mature biofilms, blocking quorum sensing, inhibiting bacterial metabolism, and energy driving penetration. In addition, we presented the key challenges still faced by nanobiomaterials in combating bacterial biofilm infections. Firstly, the dense structure of EPS caused biofilms spatial heterogeneity and metabolic heterogeneity, which created exacting requirements for the design, construction and preparation process of nanobiomaterials. Secondly, biofilm disruption carried the risk of spread and infection the pathogenic bacteria, which might lead to other infections. Finally, we emphasized the role of nanobiomaterials in the development trends and translational prospects in biofilm treatment.
6.Association between atrial fibrillation reoccurrence and new-onset ischemic stroke among patients with nonvalvular atrial fibrillation.
Liu HE ; Chao JIANG ; Chen Xi JIANG ; Ri Bo TANG ; Cai Hua SANG ; De Yong LONG ; Xin DU ; Jian Zeng DONG ; Chang Sheng MA
Chinese Journal of Cardiology 2023;51(9):944-950
Objective: Explore the association between atrial fibrillation (AF) reoccurrence and new-onset ischemic stroke (IS) in patients with nonvalvular AF, and explore whether there is a high-risk period of IS after recurrent episodes of AF. Methods: A nested case-control study design was used. A total of 565 nonvalvular AF patients with new-onset IS after a follow-up of at least 2 years in the China-AF cohort were enrolled as the case group, and 1 693 nonvalvular AF patients without new-onset IS were matched as the control group at a ratio of 1∶3. Frequency and types of recurrent AF in the previous 1 or 2 years were compared between two groups, and the adjusted associations of AF reoccurrence with new onset IS were explored using conditional logistic regression analysis. The proportion of recurrent AF was compared between the case period and control period, and conditional logistic regression analysis was performed to calculate adjusted associations of case-period AF with IS. Results: The nested case-control study design results showed that the proportion of at least one record of recurrent AF in the previous 1 year was higher in the case group than in the control group (72.0% vs. 60.8%, P<0.05), and the recurrent AF was positively correlated with new-onset IS (adjusted OR=1.80, P<0.001). Similar results were also observed in the previous 2 years period. The case-crossover study design analysis showed that among 565 patients with new-onset IS, recurrent AF in the case period was positively correlated with IS (adjusted OR=1.61, P=0.003). Conclusion: Recurrent AF is associated with IS, and there may be a high-risk period of IS after recurrent episodes of AF.
Humans
;
Atrial Fibrillation/epidemiology*
;
Case-Control Studies
;
Cross-Over Studies
;
Ischemic Stroke
;
China/epidemiology*
7.Association between atrial fibrillation reoccurrence and new-onset ischemic stroke among patients with nonvalvular atrial fibrillation.
Liu HE ; Chao JIANG ; Chen Xi JIANG ; Ri Bo TANG ; Cai Hua SANG ; De Yong LONG ; Xin DU ; Jian Zeng DONG ; Chang Sheng MA
Chinese Journal of Cardiology 2023;51(9):944-950
Objective: Explore the association between atrial fibrillation (AF) reoccurrence and new-onset ischemic stroke (IS) in patients with nonvalvular AF, and explore whether there is a high-risk period of IS after recurrent episodes of AF. Methods: A nested case-control study design was used. A total of 565 nonvalvular AF patients with new-onset IS after a follow-up of at least 2 years in the China-AF cohort were enrolled as the case group, and 1 693 nonvalvular AF patients without new-onset IS were matched as the control group at a ratio of 1∶3. Frequency and types of recurrent AF in the previous 1 or 2 years were compared between two groups, and the adjusted associations of AF reoccurrence with new onset IS were explored using conditional logistic regression analysis. The proportion of recurrent AF was compared between the case period and control period, and conditional logistic regression analysis was performed to calculate adjusted associations of case-period AF with IS. Results: The nested case-control study design results showed that the proportion of at least one record of recurrent AF in the previous 1 year was higher in the case group than in the control group (72.0% vs. 60.8%, P<0.05), and the recurrent AF was positively correlated with new-onset IS (adjusted OR=1.80, P<0.001). Similar results were also observed in the previous 2 years period. The case-crossover study design analysis showed that among 565 patients with new-onset IS, recurrent AF in the case period was positively correlated with IS (adjusted OR=1.61, P=0.003). Conclusion: Recurrent AF is associated with IS, and there may be a high-risk period of IS after recurrent episodes of AF.
Humans
;
Atrial Fibrillation/epidemiology*
;
Case-Control Studies
;
Cross-Over Studies
;
Ischemic Stroke
;
China/epidemiology*
8.Antimicrobial susceptibility of Gram-positive organisms:Results from China antimicrobial resistance surveillance trial(CARST)program,2021-2022
Yun LI ; Bo ZHENG ; Feng XUE ; Xiu-Zhen ZHANG ; Yun-Jian HU ; Yu-Fen JIN ; Jian-Hong ZHAO ; Shi-Yang PAN ; Wei GUO ; Feng ZHAO ; Yun-Song YU ; Xuan CAI ; Wen-En LIU ; De-Hua LIU ; Ying FEI ; Jia-Yun LIU ; Feng-Yan PEI ; Ling MENG ; Ping JI ; Jin TANG ; Kai XU ; Lei ZHU ; Cun-Wei CAO ; He-Ping XU ; Shan WANG ; Lan-Qing CUI ; Jia ZHANG ; Yao-Yao LIU
The Chinese Journal of Clinical Pharmacology 2023;39(23):3509-3524
Objective To investigate the Gram-positive coccus resistance in nationwide's tertiary hospitals and understand the trend of antimicrobial resistance.Methods All the clinical isolates were collected from 19 hospitals and the minimal inhibitory concentrations(MICs)were tested using agar/broth dilution method recommended.Results A total of 1 974 pathogenic Gram-positive coccus from 19 tertiary hospitals in 19 cities nationwide over the period from July 2021 to June 2022 were studied.Based on the MIC results,the prevalence of methicillin resistant Stapylococcus aureus(MRSA)and methicillin resistant Stapylococcus epidermidis(MRSE)were 36.4%and 79.9%respectively.No vancomycin insensitivity Staphylococcus was detected.Staphylococcus aureus were 100%susceptibility to linezolid and teicoplanin.Antibiotic resistance rate of Enterococcus faecalis and Enterococcus faecium to ampicillin were 3.1%and 92.9%.The detectation rate of vancomycin resistant Enterococcus(VRE)was 1.6%.Nonsusceptibility rate of Enterococcus faecalis to linezolid was 32.2%,two consecutive monitoring rises and nonsusceptibility rate of Enterococcus faecium(12.5%)was also significantly increased.The prevalence of penicillin non-susceptible Streptococcus pneumoniae(PNSSP)was 0.8%based on non-meningitis and parenteral administration criterion,decrease of nearly 30 percentage points from the previous surveillance.While for cases of oral penicillin,the rate was 71.8%,showing similar to last time.The results indicated that the number of strains with higher MIC value of penicillin(MIC ≥4 mg·L-1)decreased significantly.There were no significant differences of resistance rates of Stapylococcus aureus,Stapylococcus epidermidis,Enterococcus faecalis,Enterococcus faecium and Streptococcus pneumoniae among various groups such as different department,age,or specimen source.Conclusion VRE detection ratio stablized at a relatively low level.The number of Streptococcus pneumoniae with higher MIC value of penicillin decreased significantly compared with the previous monitoring.The increase of linezolidin-insensitive Enterococcus was noteworthy.
9.Antimicrobial susceptibility of Gram-negative organisms:Results from China antimicrobial resistance surveillance trial(CARST)program,2021-2022
Yun LI ; Bo ZHENG ; Feng XUE ; Xiu-Zhen ZHANG ; Yun-Jian HU ; Yu-Fen JIN ; Jian-Hong ZHAO ; Shi-Yang PAN ; Wei GUO ; Feng ZHAO ; Yun-Song YU ; Xuan CAI ; Wen-En LIU ; De-Hua LIU ; Ying FEI ; Jia-Yun LIU ; Feng-Yan PEI ; Ling MENG ; Ping JI ; Jin TANG ; Kai XU ; Lei ZHU ; Cun-Wei CAO ; He-Ping XU ; Shan WANG ; Lan-Qing CUI ; Jia ZHANG ; Yao-Yao LIU
The Chinese Journal of Clinical Pharmacology 2023;39(23):3525-3544
Objective To investigate the Gram-negative bacteria resistance in nationwide's tertiary hospitals and understand the trend of antimicrobial resistance.Method All the clinical isolates were collected from 19 hospitals and the minimal inhibitory concentrations(MICs)were tested using agar/broth dilution method recommended.Results A total of 4 066 pathogenic isolates from 19 tertiary hospitals in 19 cities nationwide over the period from July 2021 to June 2022 were studied.Based on the MIC results,Escherichia coli and Klebsiella pneumoniae showed extended spectrum β-lactamase(ESBLs)phenotype rates of 55.0%and 21.0%,respectively,ESBLs phenotype rate of Klebsiella pneumoniae keep going down.The ratios of carbapenems resistance Klebsiella pneumoniae increased by 5 percentage points compared with the previous monitoring.Carbapenems,moxalactam,sitafloxacin,β-lactam combination agents,fosfomycin trometamol,and amikacin displayed desirable antibacterial activity against Enterbacterales,susceptibal rates were above 75%.In addition,tigacycline,omacycline,colistin and fluoxefin maintained good antibacterial activity against their respective effective bacteria/species,and the bacterial sensitivity rates by more than 80%.Resistance rates of Pseudomonas aeruginosa and Acinetobacter baumannnii to imipenem were 26.3%and 72.1%and multidrug-resistant(MDR)detection rates were 41.1%and 77.3%,extensively drug-resistant(XDR)were 12.0%and 71.8%,respectively.Comparison of drug resistance rates from different wards,ages and specimen sources indicated that the proportion of resistance in Klebsiella pneumoniae and Acinetobacter baumannii isolated from intensive care unit(ICU)were significantly higher than non-ICU.Carbapenem resistance rates of Klebsiella pneumoniae isolated from ICU were more than 35%.Resistance rates of Haemophilus influenzae isolated in children to β-lactam,macrolide,clindamycin and ESBLs detection rate in Klebsiella pneumoniae isolated from children were more than those from adults and the old people,so bacterial resistance in children is an important problem in China.Conclusion ESBLs detection rate of Escherichia coli increased slightly after years of continuous decline.The proportion of carbapenem resistant Pseudomonas aeruginosa was stable,but the resistance rate of Klebsiella pneumoniae and Acinetobacter baumannii to carbapenems was still increased,which should be paid more attention.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail