1.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.
2.Development, reliability, and validity of a treatment-related quality of life scale for Chinese patients with multiple myeloma
Chunyan SUN ; Zhen CAI ; Bing CHEN ; Lijuan CHEN ; Wenming CHEN ; Kaiyang DING ; Juan DU ; Rong FU ; Chengcheng FU ; Da GAO ; Guangxun GAO ; Yanjuan HE ; Jian HOU ; Ming JIANG ; Fei LI ; Jian LI ; Juan LI ; Zhenyu LI ; Aijun LIAO ; Jing LIU ; Jun LUO ; Jianmin LUO ; Yanping MA ; Jianqing MI ; Ting NIU ; Hongling PENG ; Yongping SONG ; Luqun WANG ; Rong ZHAN ; Xi ZHANG ; Yu HU
Chinese Journal of Hematology 2025;46(8):713-721
Objective:To develop a treatment-related quality of life scale for Chinese patients with multiple myeloma (MM) and to test its reliability and validity.Methods:The initial scale was constructed through a literature search, Delphi expert correspondence, and cognitive testing. This study conducted a preliminary survey of 379 patients with MM and a formal survey of 865 patients from the hematology departments of 155 hospitals nationwide from February 2024 to March 2024. The final scale was obtained after conducting item analysis and reliability and validity tests on the initial scale.Results:The constructed scale contains 36 items covering six domains: physiological, psychological, social, treatment side effects, general health, and others. In the preliminary survey, the Cronbach’s alpha coefficient of each item ranged from 0.597 to 0.939, and the test-retest reliability was 0.747 ( P<0.001). Exploratory factor analysis extracted eight common factors with a cumulative variance contribution of 60.058%. In the formal survey, the Cronbach’s alpha coefficient of each item ranged from 0.484 to 0.930, and the test-retest reliability was 0.835 ( P<0.001). Confirmatory factor analysis revealed a comparative fit index of 0.750, a root-mean-square error of approximation of 0.090, and a root-mean-square residual of 0.067. Conclusion:The treatment-related quality of life scale for Chinese patients with MM designed in this study exhibited good reliability and validity, reflecting the impact of treatment on the quality of life of patients. This scale can provide a reference to clinicians for assessing the disease status of patients.
3.Effectiveness of Lianhua Qingwen Granule and Jingyin Gubiao Prescription in Omicron BA.2 Infection and Hospitalization: A Real-World Study of 56,244 Cases in Shanghai, China.
Yu-Jie ZHANG ; Guo-Jian LIU ; Han ZHANG ; Chen LIU ; Zhi-Qiang CHEN ; Ji-Shu XIAN ; Da-Li SONG ; Zhi LIU ; Xue YANG ; Ju WANG ; Zhe ZHANG ; Lu-Ying ZHANG ; Hua FENG ; Yan-Qi ZHANG ; Liang TAN
Chinese journal of integrative medicine 2025;31(1):11-18
OBJECTIVE:
To examine the effectiveness of Chinese medicine (CM) Lianhua Qingwen Granule (LHQW) and Jingyin Gubiao Prescription (JYGB) in asymptomatic or mild patients with Omicron infection in the shelter hospital.
METHODS:
This single-center retrospective cohort study was conducted in the largest shelter hospital in Shanghai, China, from April 10, 2022 to May 30, 2022. A total of 56,244 asymptomatic and mild Omicron cases were included and divided into 4 groups, i.e., non-administration group (23,702 cases), LHQW group (11,576 cases), JYGB group (12,112 cases), and dual combination of LHQW and JYGB group (8,854 cases). The length of stay (LOS) in the hospital was used to assess the effectiveness of LHQW and JYGB treatment on Omicron infection.
RESULTS:
Patients aged 41-60 years, with nadir threshold cycle (CT) value of N gene <25, or those fully vaccinated preferred to receive CM therapy. Before or after propensity score matching (PSM), the multiple linear regression showed that LHQW and JYGB treatment were independent influence factors of LOS (both P<0.001). After PSM, there were significant differences in LOS between the LHQW/JYGB combination and the other groups (P<0.01). The results of factorial design ANOVA proved that the LHQW/JYGB combination therapy synergistically shortened LOS (P=0.032).
CONCLUSIONS
Patients with a nadir CT value <25 were more likely to accept CM. The LHQW/JYGB combination therapy could shorten the LOS of Omicron-infected individuals in an isolated environment.
Humans
;
Drugs, Chinese Herbal/therapeutic use*
;
Male
;
Female
;
Middle Aged
;
Adult
;
China/epidemiology*
;
Hospitalization
;
COVID-19 Drug Treatment
;
COVID-19/epidemiology*
;
SARS-CoV-2
;
Retrospective Studies
;
Treatment Outcome
;
Length of Stay
;
Young Adult
;
Aged
4.Zedoarondiol Inhibits Neovascularization in Atherosclerotic Plaques of ApoE-/- Mice by Reducing Platelet Exosomes-Derived MiR-let-7a.
Bei-Li XIE ; Bo-Ce SONG ; Ming-Wang LIU ; Wei WEN ; Yu-Xin YAN ; Meng-Jie GAO ; Lu-Lian JIANG ; Zhi-Die JIN ; Lin YANG ; Jian-Gang LIU ; Da-Zhuo SHI ; Fu-Hai ZHAO
Chinese journal of integrative medicine 2025;31(3):228-239
OBJECTIVE:
To investigate the effect of zedoarondiol on neovascularization of atherosclerotic (AS) plaque by exosomes experiment.
METHODS:
ApoE-/- mice were fed with high-fat diet to establish AS model and treated with high- and low-dose (10, 5 mg/kg daily) of zedoarondiol, respectively. After 14 weeks, the expressions of anti-angiogenic protein thrombospondin 1 (THBS-1) and its receptor CD36 in plaques, as well as platelet activation rate and exosome-derived miR-let-7a were detected. Then, zedoarondiol was used to intervene in platelets in vitro, and miR-let-7a was detected in platelet-derived exosomes (Pexo). Finally, human umbilical vein endothelial cells (HUVECs) were transfected with miR-let-7a mimics and treated with Pexo to observe the effect of miR-let-7a in Pexo on tube formation.
RESULTS:
Animal experiments showed that after treating with zedoarondiol, the neovascularization density in plaques of AS mice was significantly reduced, THBS-1 and CD36 increased, the platelet activation rate was markedly reduced, and the miR-let-7a level in Pexo was reduced (P<0.01). In vitro experiments, the platelet activation rate and miR-let-7a levels in Pexo were significantly reduced after zedoarondiol's intervention. Cell experiments showed that after Pexo's intervention, the tube length increased, and the transfection of miR-let-7a minics further increased the tube length of cells, while reducing the expressions of THBS-1 and CD36.
CONCLUSION
Zedoarondiol has the effect of inhibiting neovascularization within plaque in AS mice, and its mechanism may be potentially related to inhibiting platelet activation and reducing the Pexo-derived miRNA-let-7a level.
Animals
;
MicroRNAs/genetics*
;
Exosomes/drug effects*
;
Plaque, Atherosclerotic/genetics*
;
Neovascularization, Pathologic/genetics*
;
Human Umbilical Vein Endothelial Cells/metabolism*
;
Humans
;
Blood Platelets/drug effects*
;
Apolipoproteins E/deficiency*
;
Thrombospondin 1/metabolism*
;
CD36 Antigens/metabolism*
;
Platelet Activation/drug effects*
;
Male
;
Mice
;
Mice, Inbred C57BL
5.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.
6.Development, reliability, and validity of a treatment-related quality of life scale for Chinese patients with multiple myeloma
Chunyan SUN ; Zhen CAI ; Bing CHEN ; Lijuan CHEN ; Wenming CHEN ; Kaiyang DING ; Juan DU ; Rong FU ; Chengcheng FU ; Da GAO ; Guangxun GAO ; Yanjuan HE ; Jian HOU ; Ming JIANG ; Fei LI ; Jian LI ; Juan LI ; Zhenyu LI ; Aijun LIAO ; Jing LIU ; Jun LUO ; Jianmin LUO ; Yanping MA ; Jianqing MI ; Ting NIU ; Hongling PENG ; Yongping SONG ; Luqun WANG ; Rong ZHAN ; Xi ZHANG ; Yu HU
Chinese Journal of Hematology 2025;46(8):713-721
Objective:To develop a treatment-related quality of life scale for Chinese patients with multiple myeloma (MM) and to test its reliability and validity.Methods:The initial scale was constructed through a literature search, Delphi expert correspondence, and cognitive testing. This study conducted a preliminary survey of 379 patients with MM and a formal survey of 865 patients from the hematology departments of 155 hospitals nationwide from February 2024 to March 2024. The final scale was obtained after conducting item analysis and reliability and validity tests on the initial scale.Results:The constructed scale contains 36 items covering six domains: physiological, psychological, social, treatment side effects, general health, and others. In the preliminary survey, the Cronbach’s alpha coefficient of each item ranged from 0.597 to 0.939, and the test-retest reliability was 0.747 ( P<0.001). Exploratory factor analysis extracted eight common factors with a cumulative variance contribution of 60.058%. In the formal survey, the Cronbach’s alpha coefficient of each item ranged from 0.484 to 0.930, and the test-retest reliability was 0.835 ( P<0.001). Confirmatory factor analysis revealed a comparative fit index of 0.750, a root-mean-square error of approximation of 0.090, and a root-mean-square residual of 0.067. Conclusion:The treatment-related quality of life scale for Chinese patients with MM designed in this study exhibited good reliability and validity, reflecting the impact of treatment on the quality of life of patients. This scale can provide a reference to clinicians for assessing the disease status of patients.
7.Percutaneous balloon mitral valvuloplasty guided by intracardiac echocardiography:a report of two cases
De-Jian LI ; Song CHEN ; Chao XU ; Xue JIANG ; Bo WANG ; Jian-Fei FENG ; Dong-Bang SONG ; Guo-Hui ZHANG ; Ming-Quan WANG ; Wei-Min WANG ; Da-Dong ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):295-297
For the past 30 years,percutaneous balloon mitral valve dilatation has been performed under the guidance of X-rays and bedside ultrasound.However,there are still some cases of mitral valve stenosis in the large atrium where balloon dilation failed.Intraperitoneal ultrasound-guided percutaneous balloon mitral valve plasty is accurate and feasible,which can reduce the occurrence of complications and improve the success rate of such elderly complex cases.Two patients with severe mitral stenosis underwent percutaneous balloon mitral valve plasty guided by intracardiac ultrasound.The operations were successful without any complications,which can provide reference for clinical treatment of mitral stenosis.
8.Chinese expert consensus on transcatheter tricuspid valve intervention therapy
Chinese College of Cardiovascular Physicians Structural Cardiology Group ; House Heart CHINA ; Wen-Zhi PAN ; Guang-Yuan SONG ; Da-Xin ZHOU ; Yong-Jian WU
Chinese Journal of Interventional Cardiology 2024;32(10):551-561
Tricuspid regurgitation(TR)is a common heart valve disease traditionally treated with surgery,which is invasive and high-risk.Recently,transcatheter tricuspid valve intervention(TTVI)technology has achieved major breakthroughs.It is being promoted internationally and several expert consensus documents have been launched abroad.However,in China,there is still a lack of consensus documents in this regard.In order to promote the safe,standardized and healthy development of this technology,this expert consensus is specially compiled.This consensus will introduce anatomy,epidemiology,classification and pathogenesis of TR,the traditional treatment and TTVI,preoperative evaluation and clinical efficacy endpoints.We sort out ten core viewpoints so that readers can quickly grasp the essence of the consensus.
9.2024 expert consensus on clinical pathway for transcatheter aortic valve replacement in China
Structural Cardiology Committee of Cardiovascular Physicians Branch,Chinese Medical Doctor Association ; Asia Pacific Structural Heart Disease Club ; Guang-Yuan SONG ; Wen-Zhi PAN ; Da-Xin ZHOU ; Yong-Jian WU
Chinese Journal of Interventional Cardiology 2024;32(11):601-617
Transcatheter aortic valve replacement(TAVR)has reached maturity and has entered a stage of steady and stable development in China.From 2017 to 2023,the number of centers conducting TAVR in China has increased from less than 10 to over 600,and the annual implantation volume has increased from hundreds to over 10 000.The 2018 and 2021 editions of the"Expert Consensus on Clinical Pathway for Transcatheter Aortic Valve Replacement in China"played a crucial guiding role during the golden period of TAVR development in China.With significant progress in evidence-based practice,clinical experience,guideline updates,device development,and procedure technique improvements in the TAVR field,especially the important advances in technologies developed from China,protocol optimization based on Chinese clinical practices,it is necessary to update the previous clinical pathway consensus.The new version of the clinical pathway expert consensus has updated the standard procedures for preoperative clinical assessment,perioperative imaging evaluation,standardized procedural processes,comprehensive perioperative management,and postoperative rehabilitation follow-up for TAVR patients.This update aims to further promote the healthy and standardized development of TAVR technology in China and to steadily enhance the medical and scientific research capabilities with this therapeutic technology.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail