1.Clinical and Neuroelectrophysiological Features of Autoimmune Nodopathy
Hongfei TAI ; Xunyan HUANG ; Songtao NIU ; Bin CHEN ; Yuzhi SHI ; Xingao WANG ; Fan JIAN ; Hua PAN ; Zaiqiang ZHANG
JOURNAL OF RARE DISEASES 2026;5(2):191-199
To summarize the clinical characteristics, antibody spectrum and neuroelectrophysiological features of autoimmune nodopathy(AN), and to explore the phenotypic differences among different antibody-positive subgroups. The clinical and electrophysiological data of patients definitely diagnosed with AN in Beijing Tiantan Hospital, Capital Medical University, from October 2018 to January 2026 were retrospectively analyzed. A total of 33 patients with AN were included. Antibody examination results showed that, anti-neurofascin(NF)155 antibody was the most prevalent, detected in 17 patients(51.50%), followed by anti-contactin-1(CNTN1) antibody in 8 patients(24.24%). Anti-NF186 antibody(4 cases, 12.12%), anti-contactin-associated protein 1(Caspr1) antibody(2 cases, 6.06%) and dual-target antibody positivity(2 cases, 6.06%) were relatively uncommon. The main clinical manifestations of AN patients included symmetric distal paresthesia of the extremities(32 cases, 96.97%), limb weakness(31 cases, 93.93%) and sensory ataxia(25 cases, 75.76%). Different antibody-positive subgroups presented distinct phenotypic features: patients with positive anti-NF155 antibody had a relatively younger age of onset, chronic onset and a high incidence of tremor, which was dominated by immunoglobulin(Ig)G4 subclass antibodies; patients with positive anti-CNTN1 antibody had a relatively advanced age of onset, mostly presented with acute or subacute onset, and were prone to complicated nephrotic syndrome; patients with positive anti-NF186 antibody had relatively mild nerve conduction damage; patients with anti-Caspr1 antibody manifested acute or subacute onset, with relatively elevated cerebrospinal fluid protein level and 24-h intrathecal IgG synthesis rate. The prominent neuroelectrophysiological manifestations of AN included decreased motor and sensory nerve conduction velocities, prolonged distal latency, frequent non-compressive conduction block and abnormal temporal dispersion. Definite sensory nerve action potentials could not be elicited in more than half of the patients. Patients with AN show high heterogeneity in clinical and neuroelectrophysiological characteristics, and different antibody-positive subgroups correspond to specific clinical and neuroelectrophysiological phenotypes.
2.Epidemiological distribution characteristics and transmission patterns of Campylobacter in a Shandong broiler slaughterhouse
Shuai MIAO ; Xiu-mei HUANG ; Lin WANG ; Jun-hui LIU ; Jian-mei ZHAO ; Yu-bin GAO ; Shi-ping SONG ; Si-yu ZHANG ; Na LIU ; Ge ZHAO ; Xi-yue ZHANG ; Jun-wei WANG ; Juan WANG ; Zhi-na QU
Chinese Journal of Zoonoses 2025;41(6):583-591
This research investigated the contamination level,distribution of drug-resistant strains,and molecular epidemiologi-cal characteristics of Campylobacter,and further explored transmission pathways and prevention strategies.Cecum,chicken carcass,chicken product,and environmental samples,as well as swabs from workers'hands,were collected from a slaughterhouse in a large broiler group in the Jiaodong area between August 2023 and July 2024.Quantitative contamination assessment of Campylobacter in chicken carcasses and chicken products was performed.After microbial mass spectrometry identification,the representative strains of different links were selected for drug resistance testing and whole genome sequencing(WGS).On the basis of the sequencing results,the resistance genes,virulence genes,multilocus sequence typing(MLST),and phylogenetic characteristics of representative strains were analyzed.Homology comparisons were performed between isolates and strains from patients with diarrhea in the NCBI database.A total of 297 Campylobacter strains were isolated from 806 samples,and the overall detection rate was 36.85%.The detection rate of Campylobacter was highest in the evisceration process(47.33%),followed by the cutting process(35.64%).Overall,the Campylo-bacter detection rate first increased,then decreased,and subsequently increased.Drug sensitivity testing revealed that 90 isolates were resistant to nalidixic acid and ciprofloxacin,and 94.97%of isolates were resistant to tetracycline.WGS showed that both Campylo-bacter jejuni(C.jejuni)and Campylobacter coli(C.coli)carried many drug resistance and virulence genes.ST-14176 of C.jejuni was isolated for the first time herein.The predominant ST-8261 strain of C.jejuni and ST-860,ST-829,and ST-1586 strains of C.coli are known to cause human diarrhea.LOS expression genes associated with Guillain-Barré syndrome(GBS)were detected in both C.jejuni isolates from the slaughter chain and patients with GBS.Some strains exhibited close genetic relatedness to human-derived Campylo-bacter strains from the NCBI database.The detection rate of Campylobacter in the slaughterhouse first increased,then decreased,and subsequently increased,and the quantitative contamination level of each link was similar to the detection rate.Quantitative analysis of chicken carcasses/products revealed that the average bacterial load was highest in eviscerated carcasses(102.80 cfu/g),and the high-est amount of Campylobacter in chicken products reached 451.80 cfu/g.Abundant drug resistance genes and virulence genes were iden-tified,and the drug resistance genes were highly correlated with the drug resistance rate.Therefore,surveillance intensity and control measures for Campylobacter in slaughter processes should be strengthened.
3.Design of 8-channel gene analyzer
Shi-hong MA ; Yu QIAN ; Song LIANG ; Xia-bin LI ; Jing-jing ZHANG ; Yuan ZHAO ; Wei WANG ; Jian-rong CAO
Chinese Medical Equipment Journal 2025;46(2):24-30
Objective To design an 8-channel gene analyzer to take the place of the widely used gene analyzer with problems in inconvenient consumable replacement and short storage time of electrophoresis polymer.Methods The 8-channel gene analyzer had its mechanical components composed of an automatic sample loading table,a polymer injection module,a high-voltage temperature control module,an optical module and an integrated U box,its electrical control system made up of a host computer(an embedded computer)and three slave computers(a sampling control board,a polymer injection control board and a high-voltage temperature control board).The automatic sample loading table involved in four motors and transmission systems for x,y,z directions and optical alignment,the transmission systems adopted mainly belt drive mode and the optical alignment motor had its threads with an anti-backlash structure;the polymer injuection module was manipulated by the polymer injection control board,and the polymer block was made of highly transparent acrylic material;the high-voltage temperature control module realized the regulation of electrophoresis voltage and the detection of electrophoresis current by the low-ripple precision high-voltage power supply,and controlled the temperature of the heating furnace by the proportional-integral-differential(PID)algorithm;the optical module consisted of an excitation module and a light-receiving module,which had the base of the reflector made of low expansion coefficient alloy material;the integrated U box had the electrophoresis polymer,capillary array,polymer block and anode buffer in a plastic housing;the host computer had the data acquisition software programmed with C# and C++,and the slave computers were controlled by STM32 SCM.Results The 8-channel gene analyzer had no significant differences with the widely used ABI3500 gene analyzer in resolution,precision accuracy and clinical results.Conclusion The 8-channel gene analyzer gains advantages in consumable replacement and storage time of electrophoresis polymer,and can meet the requirements for gene sequencing.[Chinese Medical Equipment Journal,2025,46(2):24-30]
4.Epidemiological distribution characteristics and transmission patterns of Campylobacter in a Shandong broiler slaughterhouse
Shuai MIAO ; Xiu-mei HUANG ; Lin WANG ; Jun-hui LIU ; Jian-mei ZHAO ; Yu-bin GAO ; Shi-ping SONG ; Si-yu ZHANG ; Na LIU ; Ge ZHAO ; Xi-yue ZHANG ; Jun-wei WANG ; Juan WANG ; Zhi-na QU
Chinese Journal of Zoonoses 2025;41(6):583-591
This research investigated the contamination level,distribution of drug-resistant strains,and molecular epidemiologi-cal characteristics of Campylobacter,and further explored transmission pathways and prevention strategies.Cecum,chicken carcass,chicken product,and environmental samples,as well as swabs from workers'hands,were collected from a slaughterhouse in a large broiler group in the Jiaodong area between August 2023 and July 2024.Quantitative contamination assessment of Campylobacter in chicken carcasses and chicken products was performed.After microbial mass spectrometry identification,the representative strains of different links were selected for drug resistance testing and whole genome sequencing(WGS).On the basis of the sequencing results,the resistance genes,virulence genes,multilocus sequence typing(MLST),and phylogenetic characteristics of representative strains were analyzed.Homology comparisons were performed between isolates and strains from patients with diarrhea in the NCBI database.A total of 297 Campylobacter strains were isolated from 806 samples,and the overall detection rate was 36.85%.The detection rate of Campylobacter was highest in the evisceration process(47.33%),followed by the cutting process(35.64%).Overall,the Campylo-bacter detection rate first increased,then decreased,and subsequently increased.Drug sensitivity testing revealed that 90 isolates were resistant to nalidixic acid and ciprofloxacin,and 94.97%of isolates were resistant to tetracycline.WGS showed that both Campylo-bacter jejuni(C.jejuni)and Campylobacter coli(C.coli)carried many drug resistance and virulence genes.ST-14176 of C.jejuni was isolated for the first time herein.The predominant ST-8261 strain of C.jejuni and ST-860,ST-829,and ST-1586 strains of C.coli are known to cause human diarrhea.LOS expression genes associated with Guillain-Barré syndrome(GBS)were detected in both C.jejuni isolates from the slaughter chain and patients with GBS.Some strains exhibited close genetic relatedness to human-derived Campylo-bacter strains from the NCBI database.The detection rate of Campylobacter in the slaughterhouse first increased,then decreased,and subsequently increased,and the quantitative contamination level of each link was similar to the detection rate.Quantitative analysis of chicken carcasses/products revealed that the average bacterial load was highest in eviscerated carcasses(102.80 cfu/g),and the high-est amount of Campylobacter in chicken products reached 451.80 cfu/g.Abundant drug resistance genes and virulence genes were iden-tified,and the drug resistance genes were highly correlated with the drug resistance rate.Therefore,surveillance intensity and control measures for Campylobacter in slaughter processes should be strengthened.
5.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
6.Design of 8-channel gene analyzer
Shi-hong MA ; Yu QIAN ; Song LIANG ; Xia-bin LI ; Jing-jing ZHANG ; Yuan ZHAO ; Wei WANG ; Jian-rong CAO
Chinese Medical Equipment Journal 2025;46(2):24-30
Objective To design an 8-channel gene analyzer to take the place of the widely used gene analyzer with problems in inconvenient consumable replacement and short storage time of electrophoresis polymer.Methods The 8-channel gene analyzer had its mechanical components composed of an automatic sample loading table,a polymer injection module,a high-voltage temperature control module,an optical module and an integrated U box,its electrical control system made up of a host computer(an embedded computer)and three slave computers(a sampling control board,a polymer injection control board and a high-voltage temperature control board).The automatic sample loading table involved in four motors and transmission systems for x,y,z directions and optical alignment,the transmission systems adopted mainly belt drive mode and the optical alignment motor had its threads with an anti-backlash structure;the polymer injuection module was manipulated by the polymer injection control board,and the polymer block was made of highly transparent acrylic material;the high-voltage temperature control module realized the regulation of electrophoresis voltage and the detection of electrophoresis current by the low-ripple precision high-voltage power supply,and controlled the temperature of the heating furnace by the proportional-integral-differential(PID)algorithm;the optical module consisted of an excitation module and a light-receiving module,which had the base of the reflector made of low expansion coefficient alloy material;the integrated U box had the electrophoresis polymer,capillary array,polymer block and anode buffer in a plastic housing;the host computer had the data acquisition software programmed with C# and C++,and the slave computers were controlled by STM32 SCM.Results The 8-channel gene analyzer had no significant differences with the widely used ABI3500 gene analyzer in resolution,precision accuracy and clinical results.Conclusion The 8-channel gene analyzer gains advantages in consumable replacement and storage time of electrophoresis polymer,and can meet the requirements for gene sequencing.[Chinese Medical Equipment Journal,2025,46(2):24-30]
7.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
8.Quality evaluation of"Sangdi"based on HPLC fingerprints combined with chemometrics
Ping LIU ; Shi-ying LUO ; Meng-jia LI ; Xiao-yan TAN ; Jian-bin SUN ; Wei-zao LUO ; Ce TANG ; Yi ZHANG
Chinese Traditional Patent Medicine 2025;47(1):14-21
AIM To evaluate the quality of Tibetan medicine"Sangdi"based on HPLC fingerprints combined with chemometrics.METHODS The analysis was performed on a 30 ℃ thermostatic Welch Ultimate AQ-C18 column(250 mm × 4.6 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1 mL/min in a gradient elution manner,and the detection wavelength was set at 245 nm,after which cluster analysis,principal component analysis and orthogonal partial least squares discriminant analysis were performed,the contents of gentiopicroside,sweroside,mangiferin,isoorientin,8-hydroxy-1,3,5-trimethoxyxanthone(R2)and 1,8-dihydroxy-3,7-dimethoxyxanthone(R3)were determined.RESULTS There were 18 common peaks in the fingerprints for 15 batches of samples with the similarities of more than 0.90.Six constituents showed good linear relationships within their own ranges(R 2 ≥ 0.999 2),whose average recoveries were 96.93%-103.58%with the RSDs of 0.82%-2.9%.Various batches of samples were clustered into 2 categories,4 principal components demonstrated the accumulative variance contribution rate of 86.404%,mangiferin,gentiopicroside and isoorientin were taken as quality difference markers.CONCLUSION This stable,reliable and reproducibe method can provide a reference for the comprehensive quality evaluation of"Sangdi".
9.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
10.Targeted screening and profiling of massive components of colistimethate sodium by two-dimensional-liquid chromatography-mass spectrometry based on self-constructed compound database.
Xuan LI ; Minwen HUANG ; Yue-Mei ZHAO ; Wenxin LIU ; Nan HU ; Jie ZHOU ; Zi-Yi WANG ; Sheng TANG ; Jian-Bin PAN ; Hian Kee LEE ; Yao-Zuo YUAN ; Taijun HANG ; Hai-Wei SHI ; Hongyuan CHEN
Journal of Pharmaceutical Analysis 2025;15(2):101072-101072
In-depth study of the components of polymyxins is the key to controlling the quality of this class of antibiotics. Similarities and variations of components present significant analytical challenges. A two-dimensional (2D) liquid chromatography-mass spectrometr (LC-MS) method was established for screening and comprehensive profiling of compositions of the antibiotic colistimethate sodium (CMS). A high concentration of phosphate buffer mobile phase was used in the first-dimensional LC system to get the components well separated. For efficient and high-accuracy screening of CMS, a targeted method based on a self-constructed high resolution (HR) mass spectrum database of CMS components was established. The database was built based on the commercial MassHunter Personal Compound Database and Library (PCDL) software and its accuracy of the compound matching result was verified with six known components before being applied to genuine sample screening. On this basis, the unknown peaks in the CMS chromatograms were deduced and assigned. The molecular formula, group composition, and origins of a total of 99 compounds, of which the combined area percentage accounted for more than 95% of CMS components, were deduced by this 2D-LC-MS method combined with the MassHunter PCDL. This profiling method was highly efficient and could distinguish hundreds of components within 3 h, providing reliable results for quality control of this kind of complex drugs.

Result Analysis
Print
Save
E-mail