1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Development and clinical translation of intelligent assistive devices for minimally invasive thoracic surgery
Jiwei ZHU ; Honghai MA ; Chunlin ZHOU ; Zhehao HE ; Tong SHEN ; Haojie YU ; Luming WANG ; Jian HU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(07):1013-1022
Although video-assisted thoracoscopic surgery (VATS) offers clear advantages, including minimal trauma and rapid recovery, stable intraoperative visualization still depends heavily on the camera assistant. Traditional manual endoscope holding is therefore susceptible to several limitations, including image instability, assistant fatigue, and poor coordination with the primary surgeon. Operating in complex and confined anatomical spaces with a rigid thoracoscope further increases the demands on hand-eye coordination. Thoracoscopic camera-holding technology has progressively evolved from passive support systems to active camera holders and robot-assisted thoracic surgery (RATS) platforms, and is now advancing toward artificial intelligence-driven tracking and intelligent control. Based on this, a series of devices, including multifunctional intelligent assistant arms and active camera-holding arms for thoracic surgery, have been developed and have attracted increasing attention. This article reviews the development of intelligent camera-holding assistant arms and discusses related advances and future directions in the field.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields.
5.Clinical Safety Monitoring of 3 035 Cases of Juvenile Feilike Mixture After Marketing in Hospital
Jian ZHU ; Zhong WANG ; Jing LIU ; Jun LIU ; Wei YANG ; Yanan YU ; Hongli WU ; Sha ZHOU ; Zhiyu PAN ; Guang WU ; Mengmeng WU ; Zhiwei JING
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):194-200
ObjectiveTo explore the clinical safety of Feilike Mixture (FLK) in the real world. MethodsThe safety of all children who received FLK from 29 institutions in 12 provinces between January 21,2021 and December 25,2021 was evaluated through prospective centralized surveillance and a nested case control study. ResultsA total of 3 035 juveniles were included. There were 29 research centers involved,which are distributed across 12 provinces,including one traditional Chinese medicine (TCM) hospital and 28 general hospitals. The average age among the juveniles was (4.77±3.56) years old,and the average weight was (21.81±12.97) kg. Among them,119 cases (3.92%) of juveniles had a history of allergies. Acute bronchitis was the main diagnosis for juveniles,with 1 656 cases (54.46%). FLK was first used in 2 016 cases (66.43%),and 142 juvenile patients had special dosages,accounting for 4.68%. Among them,92 adverse drug reactions (ADRs) occurred,including 73 cases of gastrointestinal system disorders,10 cases of metabolic and nutritional disorders,eight cases of skin and subcutaneous tissue diseases,two cases of vascular and lymphatic disorders,and one case of systemic diseases and various reactions at the administration site. The manifestations of ADRs were mainly diarrhea,stool discoloration,and vomiting,and no serious ADRs occurred. The results of multi-factor analysis indicated that special dosages (the use of FLK)[odds ratio (OR) of 2.642, 95% confidence interval (CI) of 1.105-6.323],combined administration: spleen aminopeptide (OR of 4.978, 95%CI of 1.200-20.655),and reason for combined administration: anti-infection (OR of 1.814, 95%CI of 1.071-3.075) were the risk factors for ADRs caused by FLK. Conclusion92 ADRs occurred among 3 035 juveniles using FLK. The incidence of ADRs caused by FLK was 3.03%,and the severity was mainly mild or moderate. Generally,the prognosis was favorable after symptomatic treatment such as drug withdrawal or dosage reduction,suggesting that FLK has good clinical safety.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Effect of preoperative intestinal prehabilitation on the recovery of delayed postoperative ileus in sarcopenic gastric cancer patients
Jian-Jun WU ; Guo-Zhong YAO ; Chu-Ming ZHU ; Jiang YAN ; Yu SHEN ; Shai-Di TANG ; Die WU
Parenteral & Enteral Nutrition 2025;32(5):283-287,292
Objective:To evaluate the effects and underlying mechanisms of preoperative intestinal microbiota modulation on the recovery of prolonged postoperative ileus(PPOI)in gastric cancer patients with sarcopenia Methods:Skeletal muscle mass(SMM)was assessed using bioelectrical impedance analysis(BIA),and the skeletal muscle index(SMI)was calculated.A total of 156 gastric cancer patients with sarcopenia who underwent surgery at the Department of Gastrointestinal Surgery,Liyang People's Hospital,from January 2022 to December 2024 were randomly assigned to either the control group or the experimental group.The control group received conventional prehabilitation interventions,including nutritional support,respiratory function training,and physical exercise.The experimental group received probiotic-based intestinal microbiota modulation in addition to conventional prehabilitation interventions.Postoperative recovery indicators,including time to first flatus,incidence of postoperative complications,length of hospital stay,and hospitalization costs,were compared between the two groups.Results:Among the 156 sarcopenic gastric cancer patients,121 were male,and 35 were female.Statistically significant differences were observed between the two groups in terms of time to first flatus,incidence of postoperative complications,and length of hospital stay(P<0.05).Postoperative complications occurred in 38 patients(24.3%),with 10 cases(6.4%)in the experimental group and 28 cases(17.9%)in the control group.The time to first flatus in the experimental group was significantly shorter than in the control group(48.0 hours vs 72.0 hours,P<0.001).Conclusion:Preoperative intestinal microbiota modulation significantly reduces the incidence of PPOI and postoperative complications in gastric cancer patients with low SMI,thereby promoting postoperative gastrointestinal function recovery.
8.Simultaneous Determination of 50 Kinds of Steroid Hormones in Surface Water by Online Solid Phase Extraction Coupled with Ultra Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Fang-Xi XU ; He NIU ; Yu-Tao GE ; Guo-Hua ZHU ; Hang-Bin LYU ; Jin-Song LI ; Lang-Sha YI ; Jian-Jie FU ; Gui-Bin JIANG
Chinese Journal of Analytical Chemistry 2025;53(6):998-1009,中插22-中插41
A novel analytical method was developed in this study by combining online solid phase extraction with ultra performance liquid chromatography-tandem mass spectrometry(Online SPE-UPLC-MS/MS)for simultaneous determination of 50 kinds of steroid hormones in surface water.Specifically,after high-speed centrifugation of 4 mL water samples,the supernatant was directly injected into an Oasis HLB online SPE column for enrichment and purification.Subsequently,the target compounds were transferred to the analytical column via valve switching for separation and analysis.The chromatographic separation was performed on a Thermo Acclaim RSLC C18 column(100 mm×2.1 mm,2.2 μm),using a mobile phase composed of 5 mmol/L ammonium fluoride aqueous solution and acetonitrile.Mass spectrometric detection was conducted in positive ion mode,utilizing multiple reaction monitoring(MRM)with quantification achieved by the internal standard method.The method validation demonstrated that the limits of detection(LOD)for the 50 kinds of steroid hormones ranged from 0.02 to 0.50 ng/L,while the limits of quantification(LOQ)were between 0.08 and 1.67 ng/L.The average recoveries in surface water samples at spiked concentrations of 5,20 and 200 ng/L were between 74.1%and 119%,with relative standard deviations(RSDs)of 0.2%to 9.9%.This method was applied to analyze 11 surface water samples collected from sites surrounding a pharmaceutical and chemical industrial park.A total of 44 kinds of steroid hormones were detected,with concentrations ranging from 0.11 to 88.6 ng/L,revealing the presence of hormone contamination in the environmental waters surrounding industrial areas.Compared with the traditional offline SPE methods,the proposed online SPE technique significantly reduced sample volume requirements and pretreatment time,while minimizing the loss of target compounds during the pretreatment process.Moreover,compared to reported online SPE techniques,this method achieved high-throughput analysis of multiple classes of steroid hormones,with lower detection limits and higher recoveries.Overall,this method provided rapid sample preparation,high sensitivity,and excellent stability,making it suitable for the direct analysis of trace steroid hormones in surface water.
9.Exploration of the application of vehicle-mounted 5G remote mobile robotic surgical system in thyroid surgery
Meng WANG ; Wen TIAN ; Qingqing HE ; Guolou LI ; Jian ZHU ; Xiaodong MA ; Wei WEI ; Qiongqiong TAN ; Jinzhi HU ; Yingying WANG ; Peng ZHOU ; Gang WANG ; Yixin LIU ; Hejun WANG ; Yu LIU ; Lihu LIU
International Journal of Surgery 2025;52(1):28-32
Objective:To investigate the feasibility and safety of implementing a domestic vehicle-mounted remote mobile robotic surgical system in thyroid surgery applications, integrated with 5G communication technology.Methods:Using the main system located on the vehicle-mounted mobile robot operating platform of the 960th Hospital of PLA Joint Logistics Support Force and the slave system of Weifang Traditional Chinese Hospital, the remote radical thyroidectomy 5G communication technology, and analyze the clinical and information transmission data of two female patients who underwent remote mobile robot thyroid cancer surgery on October 21, 2024 at Weifang Traditional Chinese Medicine Hospital.Results:The remote radical thyroidectomy was conducted by the robosurgeons utilizing a vehicle-mounted mobile robotic surgical system, and the procedure was successfully completed without necessitating intermediate open surgery. The operation durations for patient 1 and patient 2 were 135 minutes and 108 minutes, respectively, with 7 and 13 lymph nodes dissected, respectively. The average delay in surgical data transmission was recorded at 61.9 milliseconds, with no instances of signal interruption or frame loss. The procedure proceeded smoothly, without any jamming, and the audio and video transmissions were consistently clear. Follow up for 21 days after surgery showed no complications such as hoarseness, skin damage, or lymphatic fistula.Conclusion:The implementation of a vehicle-mounted remote mobile robotic surgery system for thyroid surgery has demonstrated safety and feasibility. Furthermore, the utilization of the 5G network offers rapid data transmission and minimal latency, closely approximating the therapeutic efficacy of traditional robotic thyroidectomy.
10.Analysis of dosimetric characteristics of proton radiotherapy in 4 cases of breast cancer
Chengqiang LI ; Yungang WANG ; Yishan YU ; Shizhang WU ; Cheng TAO ; Xingmin MA ; Tianyuan DAI ; Jinghao DUAN ; Jinhu CHEN ; Tong BAI ; Jian ZHU
Journal of International Oncology 2025;52(7):448-454
Objective:To explore the dosimetric characteristics of proton and photon radiotherapy in the treatment of breast cancer.Methods:Four female breast cancer patients who needed radiotherapy at Shandong Cancer Hospital and Institute from January 2024 to May 2024 were selected as the research subjects. The target area ranges of 4 patients were left-sided breast cancer with lymph node involvement, left-sided breast cancer with lymph node involvement and internal mammary node, right-sided breast cancer with lymph node involvement and internal mammary node and synchronous bilateral breast cancer. Intensity modulated proton therapy (IMPT) and intensity modulated radiation therapy (IMRT) plans were designed respectively based on the prescribed dose in the target area and the limits of organs at risk (tomotherapy plan for bilateral breasts). The conformity index (CI), homogeneity index (HI), gradient index (GI) and organs at risk doses were evaluated. The dosimetric characteristics of IMPT and photon radiotherapy were compared.Results:Both IMPT and photon radiotherapy plans of the 4 breast cancer cases met the clinical dose requirements. The HI value of IMPT plans (0.10-0.14) was comparable to that of photon radiotherapy plans (0.10-0.12), and the average CI of the photon radiotherapy plans was 0.10 higher than that of the IMPT plans, and the average GI was 0.55 lower than that of the IMPT plans. The D mean of ipsilateral lung and heart of IMPT was lower, especially in the low-dose area (V 0-3), which was significantly lower than the photon radiotherapy plans, D mean of ipsilateral lung was reduced by 12.2%, 6.1%, 16.1% and 34.8%, respectively, D mean of heart was reduced by 47.2%, 57.0%, 72.4% and 83.0%, respectively. The ipsilateral lung V 20 of IMPT was not lower than photon radiotherapy plans (unilateral breast: IMPT was 30.0%-34.0%, IMRT was 29.0%-35.9%) . Conclusions:IMPT significantly reduces the D mean to the ipsilateral lung and heart while ensuring dose coverage of the target in breast cancer, preventing more volume of surrounding normal tissues from being irradiated. However, IMPT does not show much more advantage than photon radiotherapy plans in the ipsilateral lung V 20.

Result Analysis
Print
Save
E-mail