1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Construction and stability analysis of finite element model for spinal canal reconstruction with miniplates fixation
Jian-Min CHEN ; Guo-Yin LIU ; Wei-Qian HUANG ; Zhong-Hua LIAN ; Er-Lai ZHANG ; Jian-Ning ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(3):271-277
Objective To establish the finite element model of spinal canal reconstruction and internal fixation,analysis influence of spinal canal reconstruction and internal fixation on spinal stability,and verify the effectiveness and reliability of spinal canal reconstruction and internal fixation in spinal canal surgery.Methods A 30-year-old male healthy volunteer with a height of 172 cm and weight of 75 kg was selected and his lumbar CT data were collected to establish a finite element model of normal lumbar Lo3-L,and the results were compared with in vitro solid results and published finite element analysis results to verify the validity of the model.They were divided into normal group,laminectomy group and spinal canal reconstruction group according to different treatment methods.Under the same boundary fixation and physiological load conditions,six kinds of ac-tivities were performed,including forward bending,backward extension,left bending,right bending,left rotation and right rota-tion,and the changes of range of motion(ROM)of L3-L4,L4-L5 segments and overall maximum ROM of L3-L5 were analyzed under the six conditions.Results The ROM displacement range of each segment of the constructed L3-L5 finite element model was consistent with the in vitro solid results and previous literature data,which confirms the validity of the model.In L3-L4,ROM of spinal canal reconstruction group was slightly increased than that of normal group during posterior extension(>5%dif-ference),and ROM of other conditions was similar to that of normal group(<5%difference).ROM in laminectomy group was significantly increase than that in normal group and spinal canal reconstruction group under the condition of flexion,extension,left and right rotation.In L4-L5,ROM in spinal canal reconstruction group was similar to that in normal group(<5%differ-ence),while ROM in laminectomy group was significantly higher than that in normal group and spinal canal reconstruction group(>5%difference).In the overall maximum ROM of L3-L5,spinal canal reconstruction group was only slightly higher than normal group under the condition of posterior extension(>5%difference),while laminectomy was significantly higher than normal group and spinal canal reconstruction group under the condition of anterior flexion,posterior extension,left and right rotation(>5%difference).The changes of each segment ROM and overall ROM of L3-L5 showed laminectomy group>spinal canal reconstruction group>normal group.Conclusion Laminectomy could seriously affect biomechanical stability of the spine,but application of spinal canal reconstruction and internal fixation could effectively reduce ROM displacement of the responsi-ble segment of spine and maintain its biomechanical stability.
8.Proximal femoral nail antirotation combined with locking plate in the treatment of femoral intertrochanteric fractures with lateral wall fractures
Shuo PENG ; Fei-Fei HUANG ; Li-Wei XIA ; Jian-Han HUANG ; Shi-Jing MENG
China Journal of Orthopaedics and Traumatology 2024;37(8):796-800
Objective To investigate the effect of locking plate internal fixation for the treatment of proximal lateral femoral wall fracture.Methods From January 2021 to June 2022,31 patients with intertrochanteric fractures and lateral wall fractures were treated.Among them,15 patients were treated with proximal femoral nail antirotation(PFNA)fixation including 3 males and 12 females with an average age of(75.87±7.46)years old;the other 16 patients were treated with 3.5 mm pre-curved screw locking plate fixtion for lateral wall fracture including 4 males and 12 females with an average age of(76.15±9.47)years old.After surgery,the surgical index,tip-apical distance(TAD),postoperative standing weight-bearing time,and fracture reduction were compared between two groups.Postoperative hip function was evaluated according to Harris hip score.Results All patients were followed up for an average of(12±5)months ranging from 7 to 17 months.The immediate postopera-tive neck angle ranged from 111° to 132°(119.3±8.3)°.Fracture reduction results were excellent in 11 cases,fair in 2,worse in 1 in PFNA group;excellent in 12,fair in 3,worse in 1 in PFNA+locking plate group.One case of the PFNA group had a spiral blade cut out through the femoral head.There were significant differences in the time of operation,the amount of blood loss during the operation,the length of incision between two groups(P<0.05).There was no significant difference in TAD and post-operative standing weight-bearing time between two groups(P>0.05).There were significant differences in Harris scores at 6 months after surgery between two groups(P<0.05).Conclusion The application of PFNA-assisted locking plate in the treat-ment of femoral intertrochanteric fractures with lateral wall fractures is effective,and can restore the integrity of lateral wall,im-prove the stability of PFNA internal fixation,and reduce postoperative complications.
9.Early gait analysis after total knee arthroplasty based on artificial intelligence dynamic image recognition
Ming ZHANG ; Ya-Nan SUI ; Cheng WANG ; Hao-Chong ZHANG ; Zhi-Wei CAI ; Quan-Lei ZHANG ; Yu ZHANG ; Tian-Tian XIA ; Xiao-Ran ZU ; Yi-Jian HUANG ; Cong-Shu HUANG ; Xiang LI
China Journal of Orthopaedics and Traumatology 2024;37(9):855-861
Objective To explore early postoperative gait characteristics and clinical outcomes after total knee arthroplasty(TKA).Methods From February 2023 to July 2023,26 patients with unilateral knee osteoarthritis(KOA)were treated with TKA,including 4 males and 22 females,aged from 57 to 85 years old with an average of(67.58±6.49)years old;body mass in-dex(BMI)ranged from 18.83 to 38.28 kg·m-2 with an average of(26.43±4.15)kg·m-2;14 patients on the left side,12 pa-tients on the right side;according to Kellgren-Lawrence(K-L)classification,6 patients with grade Ⅲ and 20 patients with grade Ⅳ;the courses of disease ranged from 1 to 14 years with an average of(5.54±3.29)years.Images and videos of standing up and walking,walking side shot,squatting and supine kneeling were taken with smart phones before operation and 6 weeks after operation.The human posture estimation framework OpenPose were used to analyze stride frequency,step length,step length,step speed,active knee knee bending angle,stride length,double support phase time,as well as maximum hip flexion angle and maximum knee bending angle on squatting position.Western Ontario and McMaster Universities(WOMAC)arthritis index and Knee Society Score(KSS)were used to evaluate clinical efficacy of knee joint.Results All patients were followed up for 5 to 7 weeks with an average of(6.00±0.57)weeks.The total score of WOMAC decreased from(64.85±11.54)before op-eration to(45.81±7.91)at 6 weeks after operation(P<0.001).The total KSS was increased from(101.19±9.58)before opera-tion to(125.50±10.32)at 6 weeks after operation(P<0.001).The gait speed,stride frequency and stride length of the affected side before operation were(0.32±0.10)m·s-1,(96.35±24.18)steps·min-1,(0.72±0.14)m,respectively;and increased to(0.48±0.11)m·s 1,(104.20±22.53)steps·min-1,(0.79±0.10)m at 6 weeks after operation(P<0.05).The lower limb support time and active knee bending angle decreased from(0.31±0.38)sand(125.21±11.64)° before operation to(0.11±0.04)s and(120.01±13.35)° at 6 weeks after operation(P<0.05).Eleven patients could able to complete squat before operation,13 patients could able to complete at 6 weeks after operation,and 9 patients could able to complete both before operation and 6 weeks after operation.In 9 patients,the maximum bending angle of crouching position was increased from 76.29° to 124.11° before operation to 91.35° to 134.12° at 6 weeks after operation,and the maximum bending angle of hip was increased from 103.70° to 147.25° before operation to 118.61° to 149.48° at 6 weeks after operation.Conclusion Gait analysis technology based on artificial intelligence image recognition is a safe and effective method to quantitatively identify the changes of pa-tients'gait.Knee pain of KOA was relieved and the function was improved,the supporting ability of the affected limb was im-proved after TKA,and the patient's stride frequency,stride length and stride speed were improved,and the overall movement rhythm of both lower limbs are more coordinated.
10.Percutaneous closure of patent foramen ovale in a low-level position using Amplatzer ADO Ⅱ occluder:a case report
Hai-Bo HU ; Hao-Jia HUANG ; Zheng-Wei LI ; Jian-Hua LÜ ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(6):346-348
Low-level patent foramen ovale nonocclusion(PFO)is a rare type of PFO in which the PFO opening is low during transcatheter closure of PFO and the distance between the PFO left atrial opening and the root of the septal side of the mitral valve is less than 9 mm,and the smallest model of the current double-disk PFO occluder(18/18)commonly used in clinical practice for low-level PFOs can touch the mitral valve,resulting in increased risk of mitral regurgitation or leaflet abrasion.The risk of mitral regurgitation or leaflet abrasion is increased,and transcatheter closure of PFO procedure can only be abandoned when encountered intraoperatively.In this article,we present a case of successful transcatheter closure of a low-level PFO using the Amplatzer ADOⅡ occluder,which provides new ideas and strategies to deel wtih this rare type of PFO.

Result Analysis
Print
Save