1.Research on software development and smart manufacturing platform incorporating near-infrared spectroscopy for measuring traditional Chinese medicine manufacturing process.
Yan-Fei WU ; Hui XU ; Kai-Yi WANG ; Hui-Min FENG ; Xiao-Yi LIU ; Nan LI ; Zhi-Jian ZHONG ; Ze-Xiu ZHANG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(9):2324-2333
Process analytical technology(PAT) is a key means for digital transformation and upgrading of the traditional Chinese medicine(TCM) manufacturing process, serving as an important guarantee for consistent and controllable TCM product quality. Near-infrared(NIR) spectroscopy has become the core technology for measuring the TCM manufacturing process. By incorporating NIR spectroscopy into PAT and starting from the construction of a smart platform for the TCM manufacturing process, this paper systematically described the development history and innovative application of the combination of NIR spectroscopy with chemometrics in measuring the TCM manufacturing process by the research team over the past two decades. Additionally, it explored the application of a validation method based on accuracy profile(AP) in the practice of NIR spectroscopy. Furthermore, the software development progress driven by NIR spectroscopy supported by modeling technology was analyzed, and the prospect of integrating NIR spectroscopy in smart factory control platforms was exemplified with the construction practices of related platforms. By integrating with the smart platform, NIR spectroscopy could improve production efficiency and guarantee product quality. Finally, the prospect of the smart platform application in measuring the TCM manufacturing process was projected. It is believed that the software development for NIR spectroscopy and the smart manufacturing platform will provide strong technical support for TCM digitalization and industrialization.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/analysis*
;
Software
;
Medicine, Chinese Traditional
;
Quality Control
2.Identification of critical quality attributes related to property and flavor of Jianwei Xiaoshi Tablets based on T1R2/T1R3/TRPV1-HEMT biosensor.
Dong-Hong LIU ; Yan-Yu HAN ; Jing WANG ; Hai-Yang LI ; Xin-Yu GUO ; Hui-Min FENG ; Han HE ; Shuo-Shuo XU ; Zhi-Jian ZHONG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(14):3930-3937
The quality of traditional Chinese medicine(TCM) is a critical foundation for ensuring the stability of its efficacy, as well as the safety and effectiveness of its clinical use. The identification of critical quality attributes(CQAs) is one of the core components of TCM preparation quality control. This study focuses on Jianwei Xiaoshi Tablets and explores their CQAs related to property and flavor from the perspective of taste receptor proteins. Three taste receptor proteins, T1R2, T1R3, and TRPV1, were selected, and a biosensor based on high-electron-mobility transistor(HEMT) was constructed to detect the interactions between Jianwei Xiaoshi Tablets and taste receptor proteins. Simultaneously, liquid chromatography-mass spectrometry(LC-MS) technology was used to analyze the chemical composition of Jianwei Xiaoshi Tablets. In examining the interaction strength, the results indicated that the interaction between Jianwei Xiaoshi Tablets and TRPV1 protein was the strongest, followed by T1R3, with the interaction with T1R2 being relatively weaker. By combining biosensing technology with LC-MS, 16 chemical components were identified from Jianwei Xiaoshi Tablets, among which six were selected as CQAs for sweetness and seven for pungency. Further validation experiments demonstrated that CQAs such as hesperidin and hesperetin had strong interactions with their corresponding taste receptor proteins. Through the combined use of multiple technological approaches, this study successfully determined the property and flavor-related CQAs of Jianwei Xiaoshi Tablets. It provides novel ideas and approach for the identification of CQAs in TCM preparations and offers comprehensive theoretical support for TCM quality control, contributing to the improvement and development of TCM preparation quality control systems.
Drugs, Chinese Herbal/chemistry*
;
Biosensing Techniques/methods*
;
TRPV Cation Channels/chemistry*
;
Tablets/chemistry*
;
Receptors, G-Protein-Coupled/genetics*
;
Quality Control
;
Taste
;
Humans
;
Mass Spectrometry
3.Two cases of creatine deficiency syndrome caused by GAMT gene mutations and literature review.
Ting-Ting ZHAO ; Zou PAN ; Jian-Min ZHONG ; Hai-Yun TANG ; Fei YIN ; Jing PENG ; Chen CHEN
Chinese Journal of Contemporary Pediatrics 2025;27(3):340-346
OBJECTIVES:
To summarize the clinical manifestations and genetic characteristics of creatine deficiency syndrome (CDS) caused by GAMT gene mutations.
METHODS:
A retrospective analysis was conducted on the clinical and genetic data of two children diagnosed with GAMT deficiency-type CDS at the Children's Medical Center of Xiangya Hospital, Central South University, from December 2020 to December 2024.
RESULTS:
The two patients presented with symptoms in infancy, and both had compound heterozygous mutations in the GAMT gene. Case 1 exhibited seizures and intellectual disability, while Case 2 had intellectual disability and attention-deficit hyperactivity disorder. Magnetic resonance spectroscopy of cranial MRI in both patients indicated reduced creatine peaks. After creatine treatment, seizures in Case 1 were controlled, but both patients continued to experience intellectual disabilities and behavioral issues. As of December 2024, a total of 21 cases have been reported in China (including this study), and 115 cases have been reported abroad. All patients exhibited developmental delay or intellectual disabilities, with 66.9% (91/136) experiencing seizures, 33.8% (46/136) presenting with motor disorders, and 36.8% (50/136) having behavioral problems. Seventy-five percent (102/136) of patients received creatine treatment, leading to significant improvements in seizures and motor disorders, although cognitive improvement was not substantial.
CONCLUSIONS
GAMT deficiency-type CDS is rare and presents with nonspecific clinical features. Timely diagnosis facilitates targeted treatment, which can partially improve prognosis.
Child
;
Female
;
Humans
;
Male
;
Creatine/deficiency*
;
Guanidinoacetate N-Methyltransferase/deficiency*
;
Intellectual Disability/genetics*
;
Mutation
;
Retrospective Studies
;
Rhabdomyolysis/genetics*
;
Language Development Disorders
;
Movement Disorders/congenital*
4.Effects of continued use of targeted therapy on patients with pulmonary arterial hypertension and complicated by hemoptysis.
Zhong-Chao WANG ; Xiu-Min HAN ; Yao ZUO ; Na DONG ; Jian-Ming WANG ; Li-Li MENG ; Jia-Wang XIAO ; Ming ZHAO ; Yuan MI ; Qi-Guang WANG
Journal of Geriatric Cardiology 2025;22(3):404-410
5.Diagnostic Value of Transrectal Contrast-Enhanced Ultrasound for Rectal Cancer With Intestinal Stenosis.
Qin FANG ; Qin-Xue LIU ; Min-Ying ZHONG ; Wei-Jun HUANG ; Yi-de QIU ; Guo-Liang JIAN
Acta Academiae Medicinae Sinicae 2025;47(5):738-743
Objective To evaluate the diagnostic value of transrectal contrast-enhanced ultrasound (CEUS) for rectal cancer with intestinal stenosis caused by tumors. Methods Forty-nine patients with rectal cancer underwent transrectal CEUS and magnetic resonance imaging (MRI) before surgery.Intraoperative tumor localization and postoperative pathological results were taken as the gold standard for diagnosis.The differences in T stage,localization,and tumor length of rectal cancer were compared between the two methods. Results The total accuracy rates of transrectal CEUS and MRI in diagnosing T stage were 75.5% (36/49) and 67.3% (33/49),which had no significant difference (χ2=0.8,P=0.371).The total accuracy rates of transrectal CEUS and MRI in judging tumor localization were 79.5% (39/49) and 77.5% (38/49),which had no significant difference (χ2=0.061,P=0.806).The measurement results of tumor length in pathological examination had no significant difference from the transrectal CEUS results (t=1.42,P=0.162) but a significant difference from the MRI results (t=3.38,P=0.001).Furthermore,transrectal CEUS detected 8 (16.3%) cases of colonic polyps among the 49 patients,while MRI did not detect colon lesions. Conclusions Transrectal CEUS has good consistency with MRI in T staging and localization judgement of rectal cancer with intestinal stenosis,and this method can more accurately evaluate the tumor length and simultaneously evaluate whether there is a lesion in the entire colon at the proximal end of stenosis.It can be used as a supplementary examination before rectal cancer treatment in clinical practice.
Humans
;
Rectal Neoplasms/complications*
;
Male
;
Middle Aged
;
Female
;
Aged
;
Contrast Media
;
Ultrasonography
;
Adult
;
Magnetic Resonance Imaging
;
Constriction, Pathologic/diagnostic imaging*
;
Aged, 80 and over
;
Intestinal Obstruction/etiology*
6.Diagnostic Value of Intestinal Ultrasound for Patients With Chronic Abdominal Pain or Diarrhea.
Ke-Xin CHEN ; Min-Ying ZHONG ; Qin-Xue LIU ; Guo-Liang JIAN
Acta Academiae Medicinae Sinicae 2025;47(5):751-757
Objective To evaluate the diagnostic value of intestinal ultrasound (IUS) for organic lesions in the intestines of patients with chronic abdominal pain or diarrhea. Methods The IUS signs in 263 patients with chronic abdominal pain or diarrhea were retrospectively analyzed.With the endoscopic examination results as the gold standard,comparison was performed for the IUS signs between the groups with positive and negative endoscopic results,as well as between the inflammatory bowel disease group and the non-specific intestinal inflammation group of positive cases.Furthermore,the detection rates of IUS in different intestinal segments were analyzed to evaluate the accuracy of IUS in the diagnosis and localization of intestinal lesions. Results Among the 263 patients,194 (73.8%) and 69 (26.2%) patients were in the groups with positive and negative endoscopic results,respectively.The diagnosis sensitivity,specificity,and accuracy of IUS were 82.0%,71.0%,and 79.1%,respectively.The proportions of positive IUS signs in the group with positive endoscopic results were higher than that in the group with negative endoscopic results (all P<0.001).The proportions of positive IUS signs in the inflammatory bowel disease group were higher than those in the non-specific bowel inflammation group (all P<0.001).When the lesion was located in the ileum,ileocecal region,and colon,IUS demonstrated good consistency with endoscopic results in locating the lesion (kappa=0.642,0.686,and 0.601,respectively),with sensitivity and specificity of 82.7% (95%CI=75.4%-88.6%) and 81.5% (95%CI=73.5%-87.9%),73.7% (95%CI=62.3%-83.1%) and 93.0% (95%CI=88.4%-96.2%),and 68.9% (95%CI=58.3%-78.2%) and 89.6% (95%CI=84.1%-93.7%),respectively. Conclusions IUS can be used for screening the patients with chronic abdominal pain or diarrhea to detect organic lesions in the intestines. Moreover,it can effectively locate the affected intestinal segment,which is helpful for the monitoring and follow-up of intestinal diseases.
Humans
;
Diarrhea/diagnostic imaging*
;
Female
;
Male
;
Abdominal Pain/diagnostic imaging*
;
Middle Aged
;
Adult
;
Ultrasonography
;
Retrospective Studies
;
Aged
;
Young Adult
;
Intestines/diagnostic imaging*
;
Adolescent
;
Chronic Disease
;
Sensitivity and Specificity
;
Aged, 80 and over
7.Bioequivalence study of ezetimibe tablets in Chinese healthy subjects
Pei-Yue ZHAO ; Tian-Cai ZHANG ; Yu-Ning ZHANG ; Ya-Fei LI ; Shou-Ren ZHAO ; Jian-Chang HE ; Li-Chun DONG ; Min SUN ; Yan-Jun HU ; Jing LAN ; Wen-Zhong LIANG
The Chinese Journal of Clinical Pharmacology 2024;40(16):2378-2382
Objective To evaluate the bioequivalence and safety of ezetimibe tablets in healthy Chinese subjects.Methods The study was designed as a single-center,randomized,open-label,two-period,two-way crossover,single-dose trail.Subjects who met the enrollment criteria were randomized into fasting administration group and postprandial administration group and received a single oral dose of 10 mg of the subject presparation of ezetimibe tablets or the reference presparation per cycle.The blood concentrations of ezetimibe and ezetimibe-glucuronide conjugate were measured by high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS),and the bioequivalence of the 2 preparations was evaluated using the WinNonlin 7.0 software.Pharmacokinetic parameters were calculated to evaluate the bioequivalence of the 2 preparations.The occurrence of all adverse events was also recorded to evaluate the safety.Results The main pharmacokinetic parameters of total ezetimibe in the plasma of the test and the reference after a single fasted administration:Cmax were(118.79±35.30)and(180.79±51.78)nmol·mL-1;tmax were 1.40 and 1.04 h;t1/2 were(15.33±5.57)and(17.38±7.24)h;AUC0-t were(1 523.90±371.21)and(1 690.99±553.40)nmol·mL-1·h;AUC0-∞ were(1 608.70±441.28),(1 807.15±630.00)nmol·mL-1·h.The main pharmacokinetic parameters of total ezetimibe in plasma of test and reference after a single meal:Cmax were(269.18±82.94)and(273.93±87.78)nmol·mL-1;Tmax were 1.15 and 1.08 h;t1/2 were(22.53±16.33)and(16.02±5.84)h;AUC0_twere(1 463.37±366.03),(1 263.96±271.01)nmol·mL-1·h;AUC0-∞ were(1 639.01±466.53),(1 349.97±281.39)nmol·mL-1·h.The main pharmacokinetic parameters Cmax,AUC0-tand AUC0-∞ of the two preparations were analyzed by variance analysis after logarithmic transformation.In the fasting administration group,the 90%CI of the log-transformed geometric mean ratios were within the bioequivalent range for the remaining parameters in the fasting dosing group,except for the Cmax of ezetimibe and total ezetimibe,which were below the lower bioequivalent range.The Cmax of ezetimibe,ezetimibe-glucuronide,and total ezetimibe in the postprandial dosing group was within the equivalence range,and the 90%CI of the remaining parameters were not within the equivalence range for bioequivalence.Conclusion This test can not determine whether the test preparation and the reference preparation of ezetimibe tablets have bioequivalence,and further clinical trials are needed to verify it.
8.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.
9.Construction and stability analysis of finite element model for spinal canal reconstruction with miniplates fixation
Jian-Min CHEN ; Guo-Yin LIU ; Wei-Qian HUANG ; Zhong-Hua LIAN ; Er-Lai ZHANG ; Jian-Ning ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(3):271-277
Objective To establish the finite element model of spinal canal reconstruction and internal fixation,analysis influence of spinal canal reconstruction and internal fixation on spinal stability,and verify the effectiveness and reliability of spinal canal reconstruction and internal fixation in spinal canal surgery.Methods A 30-year-old male healthy volunteer with a height of 172 cm and weight of 75 kg was selected and his lumbar CT data were collected to establish a finite element model of normal lumbar Lo3-L,and the results were compared with in vitro solid results and published finite element analysis results to verify the validity of the model.They were divided into normal group,laminectomy group and spinal canal reconstruction group according to different treatment methods.Under the same boundary fixation and physiological load conditions,six kinds of ac-tivities were performed,including forward bending,backward extension,left bending,right bending,left rotation and right rota-tion,and the changes of range of motion(ROM)of L3-L4,L4-L5 segments and overall maximum ROM of L3-L5 were analyzed under the six conditions.Results The ROM displacement range of each segment of the constructed L3-L5 finite element model was consistent with the in vitro solid results and previous literature data,which confirms the validity of the model.In L3-L4,ROM of spinal canal reconstruction group was slightly increased than that of normal group during posterior extension(>5%dif-ference),and ROM of other conditions was similar to that of normal group(<5%difference).ROM in laminectomy group was significantly increase than that in normal group and spinal canal reconstruction group under the condition of flexion,extension,left and right rotation.In L4-L5,ROM in spinal canal reconstruction group was similar to that in normal group(<5%differ-ence),while ROM in laminectomy group was significantly higher than that in normal group and spinal canal reconstruction group(>5%difference).In the overall maximum ROM of L3-L5,spinal canal reconstruction group was only slightly higher than normal group under the condition of posterior extension(>5%difference),while laminectomy was significantly higher than normal group and spinal canal reconstruction group under the condition of anterior flexion,posterior extension,left and right rotation(>5%difference).The changes of each segment ROM and overall ROM of L3-L5 showed laminectomy group>spinal canal reconstruction group>normal group.Conclusion Laminectomy could seriously affect biomechanical stability of the spine,but application of spinal canal reconstruction and internal fixation could effectively reduce ROM displacement of the responsi-ble segment of spine and maintain its biomechanical stability.
10.Analysis of the therapeutic effect of trochanteric flip osteotomy combined with Kocher-Langenbeck approach for high acetabular posterior wall fracture
Xiao-Pan WANG ; Xiao-Tian CHEN ; Ren-Jie LI ; Le-Yu LIU ; Xiu-Song DAI ; Jian-Zhong GUAN ; Min WU ; Xiao-Dong CHEN
China Journal of Orthopaedics and Traumatology 2024;37(7):706-712
Objective Evaluation of the clinical efficacy of f trochanteric flip osteotomy combined with Kocher-Langen-beck approach for high acetabular posterior wall fracture.Methods Between January 2020 and December 2022,20 patients with high acetabular posterior wall fractures were retrospectively analyzed,including 12 males and 8 females,aged 18 to 75 years old.They were divided into two groups according to the different surgical methods.Ten patients were treated with greater trochanteric osteotomy combined with Kocher-Langenbeck approach as the observation group,including 5 males and 5 fe-males,aged from 18 to 75 years old.Ten patients were treated with Kocher-Langenbeck approach alone as the control group,including 7 males and 3 females,aged from 18 to 71 years old.Matta reduction criteria were used to evaluate the reduction quality of the two groups,and Harris score was used to compare the hip function of the two groups at the latest follow-up.The operation time,blood loss and postoperative complications of the two groups were analyzed.Results All patients were followed up for 10 to 24 months.According to the Matta fracture reduction quality evaluation criteria,the observation group achieved anatomical reduction in 6 cases,satisfactory reduction in 3 cases,and unsatisfactory reduction in 1 case,while the control group only achieved anatomical reduction in 3 cases,satisfactory reduction in 3 cases,and unsatisfactory reduction in 4 cases.At the final follow-up,the Harris hip score ranged from 71.4 to 96.6 in the observation group and 65.3 to 94.5 in the control group.According to the results of Harris score.The hip joint function of the observation group was excellent in 6 cases,good in 3 cases,and fair in 1 case.The hip joint function of the control group was excellent in 2 cases,good in 3 cases,fair in 3 cases,and poor in 2 cases.In the observation group,the intraoperative blood loss ranged from 300 to 700 ml,and the operation dura-tion ranged from 120 to 180 min;in the control group,the intraoperative blood loss ranged from 300 to 650 ml,and the opera-tion duration ranged from 100 to 180 min.Complications in the observation group included 1 case of traumatic arthritis and 1 case of heterotopic ossification,while complications in the control group included 3 cases of traumatic arthritis,3 cases of het-erotopic ossification and 1 case of hip abduction weakness.Conclusions Trochanteric flip osteotomy combined with the Kocher-Langenbeck approach significantly improved anatomical fracture reduction rates,enhanced excellent and good hip joint function outcomes,and reduced surgical complication incidence compared to the Kocher-Langenbeck approach alone.Clinical application of this combined approach is promising,although larger studies are needed for further validation.

Result Analysis
Print
Save
E-mail