1.Conformational Epitope Mapping of C-Reactive Protein in Solution by Hydrogen/Deuterium Exchange Mass Spectrometry
Hao-Feng SUN ; Jian-Yi LIU ; Qi ZHANG ; Hui JIAO ; Min ZHOU ; De-Wei SONG
Chinese Journal of Analytical Chemistry 2025;53(4):631-639
C-Reactive protein(CRP)is an important acute-phase response protein,which is widely used in the assessment of inflammation and cardiovascular disease risk,and acts as a pathogenic factor directly involved in the disease process of certain conditions.Therefore,developing immunosuppressants targeting CRP or investigating its pathogenic mechanisms is of significant importance.Most B-cell epitopes are conformational epitopes,and studying conformational epitopes is typically challenging.To date,no methods have been reported for mapping the conformational epitopes of CRP in solution.In this study,a rapid strategy was developed for studying conformational epitopes by combining hydrogen/deuterium exchange mass spectrometry(HDX-MS)with multiparametric prediction of B-cell epitopes and protein secondary structure analysis.This approach was successfully applied to the binding sites and allosteric targets of the 115 kDa full pentameric CRP and the clinically used monoclonal antibody(mAb)5A8.The results showed that the amino acid residues 84-103,138-146,and 165-173 together form the potential conformational epitopes for mAb 5A8 on CRP,while the amino acid residues 21-32 and 175-178 were identified as potential allosteric targets.The discovery of the mAb 5A8 binding sites and allosteric targets was crucial for improving clinical diagnostic capabilities.Experimental results demonstrated that this workflow allowed rapid conformational epitope mapping of CRP under near-physiological conditions,with advantages such as high speed,high sensitivity,and high throughput.
2.Mechanism of tight junctional function injury of testicular Sertoli cells induced by high-fat diet based on NF-κB/NLRP3 signaling pathway
Run-min MAO ; Hai-xia ZHAO ; Hai-li DUAN ; Zi-hui GAO ; Ya-nan QU ; Guo-qing FU ; Jian-min MAO ; Jian-ming SUN ; Chang-cheng ZHANG
Chinese Pharmacological Bulletin 2025;41(11):2134-2142
Aim To investigate the effect of high-fat diet on the tight junction function injury of Sertoli cells through the NF-κB/NLRP3 signaling pathway in mice and to explore the underlying mechanism.Methods Male C57BL/6J mice were fed with high-fat or normal diet for five months.The body and gonadal organ weight of mice were measured,and their indices were calculated.The sperm concentration,the sperm viabili-ty,the testicular histomorphology and the expression levels of tight junction proteins ZO-1,Occludin and Claudin-11 were measured.TM4 cells were treated with palmitic acid(PA)for 24 h.Cell viability was detected by CCK-8 method.Then,TM4 cells were di-vided into different groups treated with PA(0,50,100,200 and 300 μmnol·L-1),and the expression lev-els of tight junction proteins ZO-1,Occludin and Clau-din-11 were detected by Western blot.The tight junc-tion permeability of TM4 cells were detected by transepithelial electrical resistance(TEER)and FITC-dextran.The expression levels of mRNA and proteins for the NF-κB/NLRP3 pathway-related factors were de-tected by RT-qPCR and Western blot.Results The results from animal experiments showed that high-fat diet increased body weight and seminal vesicle weight of mice,and decreased testicular index,epididymal in-dex,sperm concentration and sperm motility of mice.High-fat diet also caused testicular tissue structure damage and down-regulated the expression levels of tight junction proteins ZO-1 and Occludin,without af-fecting the expression of Claudin-11.In vitro,PA sig-nificantly down-regulated the expression levels of ZO-1,Occludin and Claudin-11 in TM4 cells,increased the cell permeability,as well as up-regulated the mRNA and protein expression levels of NLRP3/NF-κB signa-ling pathway-related factors in TM4 cells.Conclusions High-fat diet can impair the function of tight junction of testicualr Sertoli cells,and the machanism may be related to the activation of the NF-κB/NLRP3 signaling pathway,resulting in Sertoli cell inflammation in mice.
3.Current research status of ferroptosis in endometriosis
Jiahua PENG ; Ruining LIANG ; Xin SONG ; Yu SUN ; Hui JIAN ; Xiaoquan LUO
Chinese Journal of Comparative Medicine 2025;35(1):139-146
Endometriosis presents a common challenge in global women's health.Ferroptosis,as an emerging form of regulated cell death,has recently attracted attention in relation to endometriosis.In terms of disease mechanisms,ferroptosis drives ovarian endometrial fibrosis via the induction of iron overload,and promotes disease progression by regulating multiple signaling pathways,such as p38 mitogen-activated protein kinase/signal transducer and activator of transcription 6(p38MAPK/STAT6),promote angiogenesis,autophagy,etc,fueling disease progression.In terms of infertility,ferroptosis affects embryo development and ovarian function,thereby reducing fertility.From a diagnostic perspective,high expression of ferroptosis-related genes provides potential biomarkers for the early diagnosis of endometriosis,effectively distinguishing patients from healthy individuals,and showing important clinical value.In terms of treatment strategies,non-natural compounds such as Erastin,as well as natural compounds such as resveratrol,ursolic acid,and baicalein,have shown potential therapeutic effects in relieving the pathological process and related symptoms of endometriosis.This review comprehensively elucidates the key role of ferroptosis in endometriosis in terms of the disease mechanisms,infertility,diagnosis,and treatment,and explores its potential as a diagnostic biomarker and therapeutic target,thus providing new theoretical support and treatment strategies for the management of endometriosis.
4.Non-coding RNAs in alcohol-associated liver disease
Ge ZENG ; Hui GAO ; Yanchao JIANG ; Nazmul HUDA ; Themis THOUDAM ; Zhihong YANG ; Jing MA ; Jian SUN ; Suthat LIANGPUNSAKUL
Liver Research 2025;9(2):81-93
Non-coding RNAs(ncRNAs),encompassing microRNAs(miRNAs),long non-coding RNAs(lncRNAs),and circular RNAs(circRNAs),have emerged as critical regulators of gene expression and cellular function.In alcohol-associated liver disease(ALD),chronic alcohol consumption disrupts the expression and function of ncRNAs in the liver and circulation,contributing to the disease's pathogenesis and progression.Dysregulated ncRNAs influence key pathways involved in hepatocyte injury,lipid metabolism,inflam-mation,and hepatic stellate cell(HSC)activation,thereby exacerbating steatosis,inflammation,and fibrosis.Furthermore,extracellular vesicles play a pivotal role in mediating ncRNA-driven intercellular communication,amplifying liver damage and fibrosis.This review provides a comprehensive overview of the multifaceted roles of ncRNAs in ALD,with a focus on their mechanistic contributions to disease development and progression.Additionally,we discuss the potential of ncRNAs as diagnostic biomarkers and therapeutic targets,emphasizing their translational relevance in addressing the burden of ALD.
5.A detection method of arsenic free fully automatic online digestion iodine analyzer for urinary iodine
Xiuxiu SUN ; Ji'an XIE ; Shudong XU ; Jian JIANG ; Ying WEI ; Ruihan ZONG ; Ningning CHEN ; Hui LIU
Chinese Journal of Endemiology 2025;44(11):920-924
Objective:To establish an arsenic free fully automatic online digestion iodine analyzer detection method for urinary iodine (hereinafter referred to as the method).Methods:Based on the principle of iodine catalyzed antimony cerium redox reaction, a fully automatic online digestion iodine analyzer was used to determine the iodine content in urine. The effectiveness of the method in terms of detection limit, precision, accuracy (determination of urinary iodine primary standard reference materials GBW09108z and GBW09110f and spiked recovery experiment), and interference experiments was validated. The method was compared with the arsenic cerium catalytic spectrophotometry method recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:The linear range of the method was 0 - 300 μg/L, with a correlation coefficient │ r│> 0.999 5. The qualitative and quantitative detection limits were 7.41 and 18.01 μg/L, respectively. The relative standard deviation ( RSD) of urine samples with different iodine concentrations ranged from 1.0% to 1.7%. The results of the determination of iodine concentrations in urine using standard substances GBW09108z and GBW09110f were within the given standard range, with RSD < 2.5%. The range of spiked recovery rates for urine samples with different iodine concentrations was 101.3% to 104.8%, with an overall average spiked recovery rate of 103.0%. The average concentration of the baseline iodine standard solution was determined to be 116.21 μg/L, and the relative error of the concentration determination with the addition of interfering substances was less than 5.0%. The comparison results showed that there was no statistically significant difference in the measurement results between the two methods ( t = - 0.06, P = 0.952). Conclusions:The method adopts automated detection, which is simple to operate, labor-saving, and does not require the use of arsenic trioxide. It has high precision and accuracy, and is suitable for detection of large quantities of samples.
6.Research on dry and wet durability of reusable surgical gowns
Ze-chen LIN ; Min WAN ; Yu-peng SUN ; Hui-jie SUN ; Jian-jun SUN ; Qing ZHANG ; Bo ZHANG ; An-ning LI ; Fu-xin DU
Chinese Medical Equipment Journal 2025;46(6):28-33
Objective To explore the changes of durability properties of reusable surgical gowns when used in dry and wet conditions.Methods Reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material were selected as test samples,and a Martindale abrasion and pilling tester was used as the basic test platform and modified to form fixtures suitable for the wet state environment.The reusable surgical gowns underwent abrasion experiments in wet and dry conditions to observe the changes in their fiber structure,and were subjected to water penetration resistance and swelling strength tests.Results Visually the reusable surgical gowns had few changes of the microscopic textile fiber structure in dry and wet conditions,and the gowns made of single-layer polyster fiber gained advantages over the outer layers of those of 3-layer composite material in abrasion resistance with the same friction cycles.In dry and wet conditions,the hydrostatic pressure values of the gowns of single-layer polyster fiber gradually decreased with the increase of the degree of abrasion,which were always lower than those of the gowns of 3-layer composite material;the swelling strength of the gowns of single-layer polyster fiber was always greater than that of the gowns of 3-layer composite material,which decreased with the deterioration of the wear more significantly than that of the gowns of 3-layer composite material.Conclusion The reusable surgical gowns made of single-layer polyester fiber or 3-layer composite material have few differences in durability and protective properties at the early stages of ablation in dry and wet conditions.The durability of the gowns decreases as the degree of wear increases,while the trend of the decrease is slowing down until the fabric breaks down and completely loses its barrier effect.[Chinese Medical Equipment Journal,2025,46(6):28-33]
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail