1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Construction of an infectious disease risk assessment system for childcare institutions in Shanghai
Lyulan HUANG ; Ruobing HAN ; Liang TIAN ; Junhua FAN ; Yan WANG ; Ning JIANG ; Renyi ZHU ; Jian CHEN
Shanghai Journal of Preventive Medicine 2025;37(8):692-696
ObjectiveTo explore the construction of a risk assessment indicator system for common infectious diseases in Shanghai’s childcare institutions, and to provide a reference standard for the prevention and control of infectious diseases, staff training and system construction in childcare institutions. MethodsBy combining the Delphi method with the literature review and expert consultation, the hierarchical dimensions and items at all levels of the risk assessment indicator system for common infectious diseases in Shanghai’s childcare institutions were constructed, and the weighting coefficients were determined by analytic hierarchy process. ResultsA total of 14 experts from the field of childcare institutions, infectious disease control, child healthcare and health supervision participated in the Delphi consultation. The system consisted of four core dimensions: organizational management, team building, hardware equipment, and infectious disease surveillance and disposal, with the weighting coefficients of 0.285 9, 0.261 6, 0.204 3 and 0.248 2, respectively. The evaluation indicator system consisted of 4 primary indicators, 15 secondary indicators and 45 tertiary items. The positivity coefficients of the two rounds of Delphi consultation were 0.93 and 1.00, the authority coefficients were both 0.81, and the Kendall’s coefficient of concordance were 0.44 and 0.49, respectively (P<0.01). ConclusionThe high expert engagement and coordination indicate that organizational management and team building remain the critical priorities for infectious disease prevention and control in Shanghai’s childcare institutions. It is recommended to strengthen financial investment, improve institutional mechanisms, and enhance personnel reserves and capacity building for healthcare teachers, thereby systematically upgrading the infectious disease control capabilities of childcare institutions.
7.Correlation of CD200-CD200R axis and diseases and its research progress
Han XU ; Yu-xin BI ; Gui-xia LI ; Jian LI ; Liu-li WANG ; Rui-jia HAO ; Xue-min ZHENG ; Rui-jing HUANG ; Jin HAN ; Fei LI ; Gen-bei WANG
Acta Pharmaceutica Sinica 2024;59(4):822-830
CD200 and its receptor CD200R constitute an endogenous inhibitory signal. The binding of CD200 and CD200R can regulate the immune response to pathogenic stimuli, which has received much attention in recent years. It has been found that CD200-CD200R is involved in the regulation of many kinds of pathological inflammation, including autoimmune diseases, cardiac cerebrovascular disease, infection and tumor. This paper reviews the protein structure, distribution, expression, biological function of CD200-CD200R and the correlation with diseases, and analyses the current status and development ideas of CD200-CD200R as drug targets. It aims to provide theoretical support for new drug research and development based on this target.
8.Pharmacokinetics of wogonin-aloperine cocrystal in rats
Zhong-shui XIE ; Chun-xue JIA ; Yu-lu LIANG ; Xiao-jun ZHAO ; Bin-ran LI ; Jing-zhong HAN ; Hong-juan WANG ; Jian-mei HUANG
Acta Pharmaceutica Sinica 2024;59(9):2606-2611
Pharmaceutical cocrystals is an advanced technology to improve the physicochemical and biological properties of drugs. However, there are few studies on the
9.Separation and determination of chiral and achiral impurities in glimepiride tablets by supercritical fluid chromatography
Han CHEN ; Li-ju YU ; Yan-hua FENG ; Si-li LIU ; Li-li HUANG ; Jian-ping ZHU ; Ming DENG
Acta Pharmaceutica Sinica 2024;59(8):2337-2342
Separation and determination of chiral and achiral impurities in glimepiride tablets by supercritical fluid chromatography. Chiral and achiral impurities were separated on a ACQUITY UPC2 TrefoilTM CEL1 column (150 mm × 3.0 mm, 2.5 μm) maintained at 30 ℃ with the mobile phase containing a mixture of CO2 and methanol-isopropanol (1∶1) at 1 mL·min-1, and the detection wavelength was set at 228 nm. The back pressure was set at 13.8 MPa. The injection volume was 5 μL. In the chromatogram of the system suitability solution, the peaks elute in the following order: impurity Ⅳ, impurity Ⅴ, glimepiride, impurity Ⅲ, impurity Ⅰ and impurity Ⅱ. The six substances were separated successfully in 6 min using the proposed method with a resolution factor of 2.9, 1.6, 3.0, 2.0, 6.4. The impurity Ⅰ-Ⅴ detection limit (S/N = 3) was 0.17, 0.10, 0.06, 0.15, 0.10 μg·mL-1, respectively. Good linear relationship was established between the peak response and the concentration in the range of 0.48-51.30 μg·mL-1 for all impurities. The spiked recovery of impurity Ⅰ-Ⅴ was found to be acceptable for 99.9%, 98.9%, 102.1%, 100.1%, 96.3% (
10.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.