1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Investigation and determination of relative correction factor of pre-vitamin D
Jieming SHI ; Cheng WANG ; Liwen ZHANG ; Shunling DONG ; Jian LE ; Song YUAN ; Yihong LU ; Dandan WANG ; Wankui XU ; Shufeng ZHENG
Drug Standards of China 2024;25(2):147-153
Objective:To determine the relative correction factor of pre-vitamin D and simplify the calculation method of vitamin D assay.Methods:By studying the calculation method of vitamin D content in drug standards of various countries,HPLC was used to determine the relative correction factor of pre-vitamin D,and the influencing factors of determination were investigated.Results:The relative correction factors of pre-vitamin D at 254 nm and 265nm wavelength were determined by statistical analysis of 7 laboratories in China.Conclusion:Using the pre-vi-tamin D relative correction factor method to calculate the total amount of vitamin D simplified the experimental steps can be simplified by the pre-vitamin D relative correction factor method to calculate the total amount of vitamin D and the random operating errors can be avoided.The method is rapid and accurate,and lay a solid foundation for further improving the standard of vitamin D preparations.
7.The correlation between amplitude of low frequency fluctuation of spontaneous brain activity in resting-state and cognitive fusion in patients with major depressive disorder
Xiao DONG ; Huichang QIAN ; Xiaoman CHENG ; Xiaozheng LIU ; Jiehua MA ; Dandan LIU ; Jian LIU
Chinese Journal of Behavioral Medicine and Brain Science 2024;33(5):406-411
Objective:Based on the pathological model of acceptance and commitment therapy(ACT), to explore the correlation between cognitive fusion and resting-state spontaneous brain activity amplitude of low frequency fluctuation in patients with major depressive disorder(MDD).Methods:Patients with MDD ( n=19) and healthy controls (HCs, n=19)matched with gender, age, and years of education were enrolled from August 2022 to May 2023 in Hangzhou Seventh People's Hospital. 17-item Hamilton depression rating scale(HAMD-17) and cognitive fusion questionnaire(CFQ) were used to estimate the depressive symptoms and cognitive fusion of the participants. The amplitude of low frequency fluctuation(ALFF) data were collected on a 1.5 T-GE scanner. Based on DPABI v7.0 software of MATLAB 7.11.0 (R2018b), two independent sample t-test was used to compare the ALFF of the MDD group and HC group. ALFF values and the cognitive fusion scale scores were investigated by Pearson correlation analysis. Results:Compared with HCs, ALFF in patients with MDD was decreased relatively in the left triangular part of the inferior frontal gyrus(MNI: x, y, z=-36, 24, 21; t=-2.107, P=0.042), the right cuneus(CUN; MNI: x, y, z=12, -87, 24; t=-8.635, P<0.001) as well as the left calcarine fissure and surrounding cortex(MNI: x, y, z=-18, -57, 6; t=-14.188, P<0.001), while increased relatively in left superior occipital gyrus(MNI: x, y, z=-21, -72, 33; t=-7.253, P<0.001). There was a significant negative correlation between cognitive fusion and ALFF values of abnormal activity in left IFGtriang (belonging to ECN)( r=-0.57, P<0.05). Conclusion:There is a correlation between cognitive fusion and resting-state spontaneous brain activity ALFF in patients with MDD. Both cognitive fusion and depressive symptoms may affect patients' cognitive control deficits through multiple sources.
8.Association of Triglyceride Glucose-Derived Indices with Recurrent Events Following Atherosclerotic Cardiovascular Disease
Sha LI ; Hui-Hui LIU ; Yan ZHANG ; Meng ZHANG ; Hui-Wen ZHANG ; Cheng-Gang ZHU ; Yuan-Lin GUO ; Na-Qiong WU ; Rui-Xia XU ; Qian DONG ; Ke-Fei DOU ; Jie QIAN ; Jian-Jun LI
Journal of Obesity & Metabolic Syndrome 2024;33(2):133-142
Background:
Triglyceride glucose (TyG) and TyG-body mass index (TyG-BMI) are reliable surrogate indices of insulin resistance and used for risk stratification and outcome prediction in patients with atherosclerotic cardiovascular disease (ASCVD). Here, we inserted estimated average glucose (eAG) into the TyG (TyAG) and TyG-BMI (TyAG-BMI) as derived parameters and explored their clinical significance in cardiovascular risk prediction.
Methods:
This was a population-based cohort study of 9,944 Chinese patients with ASCVD. The baseline admission fasting glucose and A1C-derived eAG values were recorded. Cardiovascular events (CVEs) that occurred during an average of 38.5 months of follow-up were recorded. We stratified the patients into four groups by quartiles of the parameters. Baseline data and outcomes were analyzed.
Results:
Distribution of the TyAG and TyAG-BMI indices shifted slightly toward higher values (the right side) compared with TyG and TyG-BMI, respectively. The baseline levels of cardiovascular risk factors and coronary severity increased with quartile of TyG, TyAG, TyG-BMI, and TyAG-BMI (all P<0.001). The multivariate-adjusted hazard ratios for CVEs when the highest and lowest quartiles were compared from low to high were 1.02 (95% confidence interval [CI], 0.77 to 1.36; TyG), 1.29 (95% CI, 0.97 to 1.73; TyAG), 1.59 (95% CI, 1.01 to 2.58; TyG-BMI), and 1.91 (95% CI, 1.16 to 3.15; TyAG-BMI). The latter two showed statistical significance.
Conclusion
This study suggests that TyAG and TyAG-BMI exhibit more information than TyG and TyG-BMI in disease progression among patients with ASCVD. The TyAG-BMI index provided better predictive performance for CVEs than other parameters.
9.Robotic visualization system-assisted microsurgical reconstruction of the reproductive tract in male rats
Zheng LI ; Jian-Jun DONG ; Ming LIU ; Xun-Zhu WU ; Ren-Feng JIA ; San-Wei GUO ; Kai MENG ; Chen-Cheng YAO ; Er-Lei ZHI ; Gang LIU ; Da-Xian TAN ; Zheng LI ; Peng LI
National Journal of Andrology 2024;30(8):675-680
Objective:To evaluate the safety and efficiency of robotic visualization system(RVS)-assisted microsurgical re-construction of the reproductive tract in male rats and the satisfaction of the surgeons.Methods:We randomly divided 8 adult male SD rats into an experimental and a control group,the former treated by RVS-assisted microsurgical vasoepididymostomy(VE)or vaso-vasostomy(VV),and the latter by VE or VV under the standard operating microscope(SOM).We compared the operation time,me-chanical patency and anastomosis leakage immediately after surgery,and the surgeons'satisfaction between the two groups.Results:No statistically significant difference was observed the operation time between the experimental and the control groups,and no anasto-mosis leakage occurred after VV in either group.The rate of mechanical patency immediately after surgery was 100%in both groups,and that of anastomosis leakage after VE was 16.7%in the experimental group and 14.3%in the control.Compared with the control group,the experimental group achieved dramatically higher scores on visual comfort(3.00±0.76 vs 4.00±0.53,P<0.05),neck/back comfort(2.75±1.16 vs 4.38±1.06,P<0.01)and man-machine interaction(3.88±1.55 va 4.88±0.35,P<0.05).There were no statistically significant differences in the scores on image definition and operating room suitability between the two groups.Conclusion:RVS can be used in microsurgical reconstruction of the reproductive tract in male rats and,with its advantages over SOM in ergonomic design and image definition,has a potential application value in male reproductive system micosurgery.
10.Formulation and Analysis on the Standard of Automation and Information Technology
Xun YU ; Jiancun ZHEN ; Liyan MIAO ; Zongqi CHENG ; Wei ZHANG ; Rongsheng ZHAO ; Lan ZHANG ; Xiaoyang LU ; Jian ZHANG ; Dong LIU ; Aizong SHEN ; Weihua LAI ; Jingcheng HE
Herald of Medicine 2024;43(7):1074-1078
To improve patient-centered pharmaceutical management and pharmaceutical service capabilities in the pharmaceutical department of medical institutions,automation and information technology are indispensable.The Pharmacy Administration-Automation and Information Technology is one of the social organization standards of the Chinese Hospital Association as part 4-4 of Pharmaceutical Administration and Pharmaceutical Practice in Healthcare,which standardizes 32 key elements in four aspects:basic requirements for automation construction in medical institutions,construction of automation hardware equipment,construction of intelligent information platform,and quality management and continuous improvement.It can be used to guide medical institutions at all levels to select and optimize pharmacy automation equipment and information platforms.This article introduced the construction methods and contents of the pharmacy automation and information technology standards,to deepen the understanding of peers on this standard and promote its implementation.This article aimed to promote the modernization,informatization,and intelligence of pharmaceutical services in medical institutions,and improve the quality and efficiency of overall medical pharmaceutical administration and service.

Result Analysis
Print
Save
E-mail