Objective:To establish an arsenic free fully automatic online digestion iodine analyzer detection method for urinary iodine (hereinafter referred to as the method).Methods:Based on the principle of iodine catalyzed antimony cerium redox reaction, a fully automatic online digestion iodine analyzer was used to determine the iodine content in urine. The effectiveness of the method in terms of detection limit, precision, accuracy (determination of urinary iodine primary standard reference materials GBW09108z and GBW09110f and spiked recovery experiment), and interference experiments was validated. The method was compared with the arsenic cerium catalytic spectrophotometry method recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:The linear range of the method was 0 - 300 μg/L, with a correlation coefficient │ r│> 0.999 5. The qualitative and quantitative detection limits were 7.41 and 18.01 μg/L, respectively. The relative standard deviation ( RSD) of urine samples with different iodine concentrations ranged from 1.0% to 1.7%. The results of the determination of iodine concentrations in urine using standard substances GBW09108z and GBW09110f were within the given standard range, with RSD < 2.5%. The range of spiked recovery rates for urine samples with different iodine concentrations was 101.3% to 104.8%, with an overall average spiked recovery rate of 103.0%. The average concentration of the baseline iodine standard solution was determined to be 116.21 μg/L, and the relative error of the concentration determination with the addition of interfering substances was less than 5.0%. The comparison results showed that there was no statistically significant difference in the measurement results between the two methods ( t = - 0.06, P = 0.952). Conclusions:The method adopts automated detection, which is simple to operate, labor-saving, and does not require the use of arsenic trioxide. It has high precision and accuracy, and is suitable for detection of large quantities of samples.
2.RCM method-based study on preventive maintenance strategy of heating,ventilation and air-conditioning system in pharmacy intravenous admixture services
Liu-liu ZONG ; Yun-zhi YANG ; Jing ZHAO ; Yun MO ; Dong-hui LAO ; Jian-zhong ZHANG ; Xiao-yu LI ; Qian-zhou LYU
Chinese Medical Equipment Journal 2025;46(10):78-83
Objective To propose a preventive maintenance strategy of the heating,ventilation and air-conditioning(HVAC)system in pharmacy intravenous admixture services(PIVAS)based on the reliability centered maintenance(RCM)method so as to provide references for PIVAS equipment maintenance.Methods Firstly,a HVAC system RCM review team was formed,and the failure modes and impacts of important functional components of the equipment were analyzed to clarify the consequences of the failure of each functional component under the premise of ensuring the safety and integrity of the equipment and with the goal of minimizing the loss of maintenance downtime and the consumption of maintenance resources.Secondly,with a standardized logical decision-making procedure the preventive maintenance strategy was determined and implemented based on the consequences of functional failure.Finally,statistical analyses were carried out on such equipment indicators as performance parameter qualification rate,failure rate and maintenance cost before and after the RCM method-based strategy was executed,in order to evaluate the efficacy of the strategy.Results The RCM method-based preventive maintenance strategy had the performance qualification rate increased from 97.47%to 99.06%(χ2=24.139,P<0.01),the failure rate decreased from 0.24%to 0.03%(χ2=13.519,P<0.01)and the maintenance cost reduced by 11.5%,from RMB 134,200 to 118,700.Conclusion The RCM method-based preventive maintenance strategy provides reliable equipment for PIVAS and lowers the maintenance cost effectively,and references are given for the development of automated and intelligent equipment maintenance strategies for PIVAS.[Chinese Medical Equipment Journal,2025,46(10):78-83]
3.RCM method-based study on preventive maintenance strategy of heating,ventilation and air-conditioning system in pharmacy intravenous admixture services
Liu-liu ZONG ; Yun-zhi YANG ; Jing ZHAO ; Yun MO ; Dong-hui LAO ; Jian-zhong ZHANG ; Xiao-yu LI ; Qian-zhou LYU
Chinese Medical Equipment Journal 2025;46(10):78-83
Objective To propose a preventive maintenance strategy of the heating,ventilation and air-conditioning(HVAC)system in pharmacy intravenous admixture services(PIVAS)based on the reliability centered maintenance(RCM)method so as to provide references for PIVAS equipment maintenance.Methods Firstly,a HVAC system RCM review team was formed,and the failure modes and impacts of important functional components of the equipment were analyzed to clarify the consequences of the failure of each functional component under the premise of ensuring the safety and integrity of the equipment and with the goal of minimizing the loss of maintenance downtime and the consumption of maintenance resources.Secondly,with a standardized logical decision-making procedure the preventive maintenance strategy was determined and implemented based on the consequences of functional failure.Finally,statistical analyses were carried out on such equipment indicators as performance parameter qualification rate,failure rate and maintenance cost before and after the RCM method-based strategy was executed,in order to evaluate the efficacy of the strategy.Results The RCM method-based preventive maintenance strategy had the performance qualification rate increased from 97.47%to 99.06%(χ2=24.139,P<0.01),the failure rate decreased from 0.24%to 0.03%(χ2=13.519,P<0.01)and the maintenance cost reduced by 11.5%,from RMB 134,200 to 118,700.Conclusion The RCM method-based preventive maintenance strategy provides reliable equipment for PIVAS and lowers the maintenance cost effectively,and references are given for the development of automated and intelligent equipment maintenance strategies for PIVAS.[Chinese Medical Equipment Journal,2025,46(10):78-83]
4.A detection method of arsenic free fully automatic online digestion iodine analyzer for urinary iodine
Xiuxiu SUN ; Ji'an XIE ; Shudong XU ; Jian JIANG ; Ying WEI ; Ruihan ZONG ; Ningning CHEN ; Hui LIU
Chinese Journal of Endemiology 2025;44(11):920-924
Objective:To establish an arsenic free fully automatic online digestion iodine analyzer detection method for urinary iodine (hereinafter referred to as the method).Methods:Based on the principle of iodine catalyzed antimony cerium redox reaction, a fully automatic online digestion iodine analyzer was used to determine the iodine content in urine. The effectiveness of the method in terms of detection limit, precision, accuracy (determination of urinary iodine primary standard reference materials GBW09108z and GBW09110f and spiked recovery experiment), and interference experiments was validated. The method was compared with the arsenic cerium catalytic spectrophotometry method recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:The linear range of the method was 0 - 300 μg/L, with a correlation coefficient │ r│> 0.999 5. The qualitative and quantitative detection limits were 7.41 and 18.01 μg/L, respectively. The relative standard deviation ( RSD) of urine samples with different iodine concentrations ranged from 1.0% to 1.7%. The results of the determination of iodine concentrations in urine using standard substances GBW09108z and GBW09110f were within the given standard range, with RSD < 2.5%. The range of spiked recovery rates for urine samples with different iodine concentrations was 101.3% to 104.8%, with an overall average spiked recovery rate of 103.0%. The average concentration of the baseline iodine standard solution was determined to be 116.21 μg/L, and the relative error of the concentration determination with the addition of interfering substances was less than 5.0%. The comparison results showed that there was no statistically significant difference in the measurement results between the two methods ( t = - 0.06, P = 0.952). Conclusions:The method adopts automated detection, which is simple to operate, labor-saving, and does not require the use of arsenic trioxide. It has high precision and accuracy, and is suitable for detection of large quantities of samples.
5.The Genetic Polymorphism and Structural Analysis of 47 Microhaplotypes in a Jiangsu Changshu Chinese Han Population
Kun-Peng PAN ; Yao-Sen FENG ; Wen-Shuai YU ; Zong-Wei LIU ; Yi-Ren YAO ; Jie ZHAO ; Ke-Lai KANG ; Chi ZHANG ; Le WANG ; Jian WU
Progress in Biochemistry and Biophysics 2024;51(2):423-434
ObjectiveTo investigate the genetic polymorphism and structure of 47 autosomal microhaplotypes in the Han population in Changshu City, Jiangsu Province, and to evaluate the forensic efficiencies and forensic parameters. MethodsThe DNA library of unrelated individual samples was prepared according to MHSeqTyper47 kit manual and sequenced on the MiSeq FGx platform. Microhaplotype genotyping and sequencing depth statistics were processed using MHTyper. The genetic information of samples was then evaluated. The fixation index and genetic distance between the Jiangsu Changshu population and the reference populations in the 1000 Genomes Project phase 3 (1KG) were calculated, and forensic parameters were evaluated. ResultsThe fixation index and genetic distance between the Han population in Changshu, Jiangsu, and the CHB (Han Chinese in Beijing, China) reference population in 1KG were the lowest. The effective allele number (Ae) of each locus is also the closest between the two populations. The combined matching probability (CMP) of the Changshu Han population is close to the 5 populations of the East Asian reference super-population in 1KG, which is 1.25×10-36, and the combined probability of exclusion reached 0.999 999 999 964 1. ConclusionThis study reported the genetic polymorphism and allele frequency of 47 microhaplotypes in a Han population in Changshu City, Jiangsu Province. This information provides a data basis for 47 microhaplotypes in forensic applications. In addition, the polymorphism differences between the 1KG reference population and the Han population in Changshu, Jiangsu were compared, and the genetic structure of 47 microhaplotypes in the Han population in Changshu, Jiangsu was revealed. In general, the reference data of the East Asian super-population in 1KG is more in line with the genetic characteristics of Han population in Changshu, Jiangsu.
6.Effect of Yiguan Decoction on the efficacy of M1 bone marrow-derived macrophages in treatment of liver cirrhosis rats and its mechanism
Mengyao ZONG ; Xun JIAN ; Danyang WANG ; Yannan XU ; Xinrui ZHENG ; Feifei XING ; Gaofeng CHEN ; Jiamei CHEN ; Ping LIU ; Yongping MU
Journal of Clinical Hepatology 2024;40(8):1612-1619
Objective To investigate the effect and mechanism of Yiguan Decoction(YGJD)on the efficacy of M1 bone marrow-derived macrophages(M1-BMDMs)in the treatment of rats with liver cirrhosis induced by 2-AAF/CCl4.Methods BMDMs were isolated and induced into M1-BMDMs by lipopolysaccharide.A total of 50 male Wistar rats were randomly divided into normal group with 5 rats and model group with 45 rats.The rats for modeling were given subcutaneous injection of 50%CCl4 twice a week.Since week 7,the rats for modeling were randomly divided into model group(M group),YGJD group,M1-BMDM group,M1-BMDM+YGJD group,and sorafenib(SORA)group,and they were given subcutaneous injection of 30%CCl4 to maintain the progression of liver cirrhosis and intragastric administration of 2-AAF.CCR2 inhibitors were added to the drinking water,and each group was given the corresponding intervention.Related samples were collected at week 9.The rats were observed in terms of serum liver function parameters,liver pathology,hydroxyproline(Hyp)content in liver tissue,hepatic stellate cell activation,hepatic fibrosis and inflammation factors,and the expression levels of molecules associated with the Wnt signaling pathway.A one-way analysis of variance was used for comparison of continuous data between multiple groups,and the least significant difference t-test was used for further comparison between two groups.Results Compared with the M group,the M1-BMDM+YGJD group had significant reductions in the serum levels of alanine aminotransferase,aspartate aminotransferase,and total bilirubin(TBil)(all P<0.05)and a significant increase in the content of albumin(Alb)(P<0.05),and compared with the M1-BMDM group,the M1-BMDM+YGJD group had a significant reduction in the serum level of TBil(P<0.05)and a significant increase in the serum level of Alb(P<0.05).Compared with the M1-BMDM group,the M1-BMDM+YGJD group had significant reductions in the expression levels of CD68 and TNF-α(P<0.05).Compared with the M1-BMDM group,the M1-BMDM+YGJD group had significant reductions in Hyp content and Sirius red positive area(P<0.05).As for the non-canonical Wnt signaling pathway molecules,compared with the M1-BMDM group,the M1-BMDM+YGJD group had significantly lower mRNA and protein expression levels of Wnt5a(P<0.05)and mRNA expression level of Fzd2(P<0.05),as well as significant reductions in the mRNA expression levels of Wnt4,Wnt5b,and Fzd3(P<0.05),while there were no significant changes in the mRNA expression levels of the canonical Wnt signaling pathway molecules β-catenin,LRP5,LRP6,Fzd5,and TCF.Conclusion YGJD can enhance the therapeutic effect of M1-BMDMs on rats with liver cirrhosis induced by 2-AAF/CCl4,possibly by inhibiting the non-canonical Wnt5a/Fzd2 signaling pathway,which provides new ideas for the synergistic effect of traditional Chinese medicine on M1-BMDMs in the treatment of liver cirrhosis.
7.Phenylpropanoids from Brandisia hancei and their antioxidant activities
Chang-Fen LI ; Bin-Bin LIAO ; Zong-Xu LIU ; Hong-Yun WANG ; Xin-Jian ZHANG ; Ai-Xue ZUO
Chinese Traditional Patent Medicine 2024;46(8):2623-2630
AIM To study the phenylpropanoids from Brandisia hancei Hook.f.and their antioxidant activities.METHODS The extract from B.hancei was isolated and purified by Rp-C18,MCI,semi-preparative HPLC,silica gel and Sephadex LH-20,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The cytotoxicities was determined by MTT method,and the antioxidant activities were determined by DPPH and ABTS+free radical scavenging methods.RESULTS Fifteen phenylpropanoids were isolated and identified as(+)-pinonesinol(1),(-)-medioresinol(2),(-)-syringaresinol(3),buddlenol D(4),(7R,7'R,7″S,8S,8'S,8″S)-4',5″-dihydroxy-3,5,3',4″-tetramethoxy-7,9':7',9-diepoxy-4,8″-oxy-8,8'-sesquineo-lignan-7″,9″-diol(5),(-)-(7R,7'R,7″R,8S,8'S,8″S)-4',4″-dihydroxy-3,3',3″,5-tetramethoxy-7,9':7',9-diepoxy-4,8″-oxy-8,8'-sesquineolignan-7″,9″-diol(6),hedyotol A(7),dracunculifoside R(8),acteoside(9),isoacteoside(10),arenarioside(11),isomartynoside(12),curcasinlignan B(13),erythro-2,3-bis(4-hydroxy-3-methoxyphenyl)-3-ethoxypropan-l-ol(14),citrusin C(15).Compounds 1-4 and 9-10 had no obvious cytotoxicity to HepG2 hepatoma cells.Compounds 1,3,9,10 and 12 had strong scavenging activities against DPPH radicals.Compounds 1-3,9-10,12 and 14 showed strong scavenging activities against ABTS+radical.CONCLUSION Compounds 1-8 and 12-15 are isolated from genus Brandisia for the first time.The phenylpropanoids from B.hancei show strong antioxidant activities.
8.Analysis of constituents absorbed into blood and brain from Zhishe Tongluo Capsules
Xiao-Yan ZHANG ; Yang LIU ; Xiao-Ting WANG ; Hai-Feng WANG ; Zhi-Biao DI ; Jian-Fang SONG ; Shi-Yu ZONG ; Hong ZHANG
Chinese Traditional Patent Medicine 2024;46(11):3579-3584
AIM To analyze the constituents absorbed into blood and brain from Zhishe Tongluo Capsules.METHODS Sixteen rats were randomly assigned into four groups and given intragastric administration(3.1 g/kg),after which the cerebral ischemia-reperfusion injury(MACO)model was established,the blood and brain tissues were collected,and UHPLC-Q Exactive Focus MS/MS was adopted in the identification of prototype constituents.RESULTS Total 70 constituents were identified,20 of which were found in the blood,mainly including flavonoids,tanshinones and Ligusticum chuanxiong phthalides,and 7 of them could enter the brain through blood-brain barrier.Compared with the normal administration group,the MACO administration group demonstrated added constituents absorbed into blood containing 3-hydroxybenzoic acid,calycosin-7-glucoside,curcumenol,senkyunolide B,dihydrotanshinone I and cryptotanshinone;removed constituents absorbed into brain containing puerarin,elemicin,sedanolide,and added those containing salvianolic acid A,senkyunolide I,dihydrotanshinone I in the left brain tissues(infarcted side).CONCLUSION The constituents absorbed into blood and brain from Zhishe Tongluo Capsules,along with the enhanced absorptions of phthalides,quinones and phenols in MACO rats in vivo may be the active substances for treating cerebral infarction.
9.Analysis of verification results of protective effects of hearing protectors in different industries.
Han Xue SHI ; Shi Biao SU ; Ming LIU ; Rong Zong LI ; Tian Jian WANG ; Bin XIAO
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(5):333-337
Objective: To get insight into the current practice of noise reduction effect of workers as they wore hearing protectors in different domestic enterprises and the possible affected factors. Methods: From October 2020 to April 2021, using a random sampling method, 1197 workers exposed to noise in petrochemical factories, textile factories, and parts manufacturing factories were selected as the study subjects. The noise reduction effect of hearing protectors worn by workers in daily use was tested using a hearing protector suitability testing system. The personal sound attenuation level (PAR) was compared among workers in three enterprises, Targeted intervention and repetitive testing were conducted for workers who did not meet the noise reduction effect required by the enterprise, and the changes in PAR of workers before and after the intervention were compared. The comparison of baseline PARs between two or more groups was performed using the Mann Whitney test, the comparison of baseline PARs with post intervention PARs was performed using the Wilcoxon signed rank sum test, and the comparison of qualitative data between two or more groups was performed using the Chi square test. Results: The median baseline PAR for all workers was 15 dB. Men, age<30 years old, education level at or above college level, working experience of 5 to 15 years, and those who used hearing protectors for 5 to 15 years had higher PARs, with statistically significant differences (P<0.05). The median difference in baseline PAR among workers from three enterprises was statistically significant (H=175.06, P<0.01). The median PAR of subjects who did not pass the baseline increased from 3 dB to 21 dB after intervention (Z=-27.92, P<0.01) . Conclusion: Some workers wearing hearing protectors do not meet the required PAR, and low PARs may be related to incorrect wearing methods and incorrect selection of hearing protectors. As a tool for testing, training, and assisting in selection, the hearing protector suitability testing system is of great significance for worker hearing protection.
Male
;
Humans
;
Adult
;
Hearing Loss, Noise-Induced/prevention & control*
;
Ear Protective Devices
;
Noise, Occupational/prevention & control*
;
Hearing
;
Audiometry

Result Analysis
Print
Save
E-mail