1.Intramedullary administration of tranexamic acid reduces bleeding in proximal femoral nail antirotation surgery for intertrochanteric fractures in elderly individuals: A randomized controlled trial.
Xiang-Ping LUO ; Jian PENG ; Ling ZHOU ; Hao LIAO ; Xiao-Chun JIANG ; Xiong TANG ; Dun TANG ; Chao LIU ; Jian-Hui LIU
Chinese Journal of Traumatology 2025;28(3):201-207
PURPOSE:
Intertrochanteric fractures undergoing proximal femoral nail antirotation (PFNA) surgery are associated with significant hidden blood loss. This study aimed to explore whether intramedullary administration of tranexamic acid (TXA) can reduce bleeding in PFNA surgery for intertrochanteric fractures in elderly individuals.
METHODS:
A randomized controlled trial was conducted from January 2019 to December 2022. Patients aged over 60 years with intertrochanteric fractures who underwent intramedullary fixation surgery with PFNA were eligible for inclusion and grouped according to random numbers. A total of 249 patients were initially enrolled, of which 83 were randomly allocated to the TXA group and 82 were allocated to the saline group. The TXA group received intramedullary perfusion of TXA after the bone marrow was reamed. The primary outcomes were total peri-operative blood loss and post-operative transfusion rate. The occurrence of adverse events was also recorded. Continuous data was analyzed by unpaired t-test or Mann-Whitney U test, and categorical data was analyzed by Pearson Chi-square test.
RESULTS:
The total peri-operative blood loss (mL) in the TXA group was significantly lower than that in the saline group (577.23 ± 358.02 vs. 716.89 ± 420.30, p = 0.031). The post-operative transfusion rate was 30.67% in the TXA group and 47.95% in the saline group (p = 0.031). The extent of post-operative deep venous thrombosis and the 3-month mortality rate were similar between the 2 groups.
CONCLUSION
We observed that intramedullary administration of TXA in PFNA surgery for intertrochanteric fractures in elderly individuals resulted in less peri-operative blood loss and decreased transfusion rate, without any adverse effects, and is, thus, recommended.
Humans
;
Tranexamic Acid/administration & dosage*
;
Hip Fractures/surgery*
;
Male
;
Aged
;
Female
;
Fracture Fixation, Intramedullary/adverse effects*
;
Blood Loss, Surgical/prevention & control*
;
Antifibrinolytic Agents/administration & dosage*
;
Aged, 80 and over
;
Bone Nails
;
Middle Aged
;
Blood Transfusion/statistics & numerical data*
2.Progress in Basic Research on Acupuncture and Moxibustion Based on Non-coding RNA
Ying WEI ; Jian XIONG ; Xiao LI ; Jinqun HU ; Yi ZHAO ; Yuxin SUN ; Fayang LING ; Yu LIU ; Liyuan YANG ; Fanrong LIANG ; Wenchuan QI
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(3):174-179
Acupuncture and moxibustion therapy is a kind of treatment and health care method with original advantages of China.With the rapid development of epigenetics and systems biology technology,non-coding RNA(ncRNA)related research has made continuous breakthroughs in the field of acupuncture and moxibustion.This article collected the basic research literature on acupuncture and moxibustion related to ncRNA,and reviewed the research subsystems related to microRNA(miRNA),long chain non coding RNA(lncRNA)and circular RNA(circRNA).NcRNAs are widely involved in the growth,development and reproduction of the organism,as well as in the occurrence and development of various diseases,which fits with the multi-layer,multi-pathway and multi-target action network of acupuncture and moxibustion therapy.Taking ncRNAs as the breakthrough point to explore the mechanism of acupuncture and moxibustion in depth is not only conducive to promoting the exploration of new targets of acupuncture and moxibustion effect,but also can reveal the epigenetic regulation axis of acupuncture and moxibustion effect molecules,and provide ideas and methods for clinical diagnosis and treatment of diseases and evaluation of efficacy.
3.Chemical constituents from the stems and barks of Maytenus variabilis
Ting HE ; Bing-qian LIU ; Jian-feng CHEN ; Xiao-qin YU ; Cheng-xiong LIU ; Kun ZOU ; Fan CHENG
Chinese Traditional Patent Medicine 2025;47(5):1539-1547
AIM To study the chemical constituents from the stems and barks of Maytenus variabilis(Hemsl.)C.Y.Cheng.METHODS The 95%ethanol extract from the stems and barks of M.variabilis was isolated and purified by silica gel,Sephadex LH-20 and semi preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.RESULTS Twenty-three compounds were isolated and identified as β-amyrin(1),3β-acetoxyolean-12-en-11-one(2),ursa-12-ene-11-one-3-ol octocosate(3),friedelin(4),canophyllol(5),pinoresinol(6),medioresinol(7),isolariciresinol(8),dihydrodehydrodiconiferyl alcohol(9),vanillic acid(10),7R,8S-5-methoxydihydrodehydroconiferyl alcohol(11),β-hydroxypropiovanillone(12),triptregeline B(13),triptregeline E(14),(+)-evofolin B(15),2,5-dimethoxybenzoquinone(16),olean-12-ene-3,11-dione(17),β-sitosterol(18),(-)-(7R,7'R,7"S,8S,8'S,8"S)-4',4"-dihydroxy-3,3',3",5-tetramethoxy-7,9',7',9-diepoxy-4,8"-oxy-8,8'-sesquineolignan-7",9"-diol(19),phyllostadimer B(20),rayalinol(21),lyoniresinol(22),dihydrobuddlenol B(23).CONCLUSION Compounds 3,9-11,13-14,16,19-21,23 are isolated from genus Maytenus for the first time,and compounds 2,4-5,7-8,12,15,17,22 are first found from this plant.
4.Chemical constituents from Anaphalis margaritacea and their antioxidant activity
Bing-qian LIU ; Biao LI ; Jian-feng CHEN ; Xiao-qin YU ; Cheng-xiong LIU ; Kun ZOU ; Fan CHENG
Chinese Traditional Patent Medicine 2025;47(11):3651-3660
AIM To study the chemical constituents of Anaphalis margaritacea(L.)Benth.& Hook.f.and their antioxidant activities.METHODS Separation and purification were performed using silica gel,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The antioxidant activity was determined by DPPH method and ABTS method.RESULTS Twenty-three compounds were isolated and identified as trans-tilidroside(1),4'-hydroxydehydrokawain(2),apigenin(3),3-O-kaempferol-3-O-acetyl-6-O-(p-coumamoyl)-α-D-glucopyranoside(4),kaempferol(5),quercetin-3-O-β-D-(6-O-Z-p-coumamoyl)-glucopyranoside(6),tiliroside(7),kaempferol-3-O-β-D-glucoside(8),3,5-dihydroxy-7,8-dimethoxyflavone(9),bis(2-ethylhexyl)adipate(10),3,5-dihydroxy-6,7,8-trimethoxyflavone(11),stigmasterol(12),myriophylloside B(13),1-hexadecanol(14),chlorogenic acid(15),4-hydroxy-N-{ 4-[3-(4-hydroxyphenyl)-E-acryloylamino]-butyl}-benzamide(16),3,6-dimethylpiperazine-2,5-dione(17),β-adenosine(18),5,6-dehydrokawain(19),kaempferol-3-O-(2",6"-di-O-E-p-coumaroyl)-β-D-glucopyranoside(20),kaempferol-3-O-(3"-O-E-p-coumaroyl)-(6"-O-E-feruloyl)-β-D-glucopyranoside(21),4,5-di-caffeoylquinic acid butyl ester(22),3,4-di-caffeoylquinic acid butyl ester(23).The IC50 values of compounds 1,7,22-23 against DPPH free radicals were(24.67±1.63)-(53.41±1.61)μmol/L,and the IC50 values of compounds 8,21-23 against ABTS+free radicals were(15.22±0.89)-(41.66±6.29)μmol/L.CONCLUSION Compounds 9,19-23 are isolated from genus Anaphalis for the first time,and 2,10,13,14,16,17,19-23 are first isolated from this plant.Compounds 1,7-8,21-23 have strong antioxidant activity.
5.The application value of digital PCR and next-generation sequencing technology in the etiological diagnosis of sepsis patients
Jian SHI ; Jing LEI ; Zeshi LIU ; Chaoliang XIONG ; Tian LI ; Yan GENG
Chinese Journal of Microbiology and Immunology 2025;45(3):256-263
Objective:To explore the value of droplet digital PCR (ddPCR) and next-generation sequencing (NGS) technology in the pathogenetic diagnosis of sepsis patients, and to provide a reference basis for the early diagnosis of sepsis.Methods:A retrospective analysis was used to collect the clinical data of 53 patients with suspected sepsis admitted to the intensive care unit (ICU) of the Second Affiliated Hospital of Xi'an Jiaotong University from February to August 2023, and the blood was collected for blood culture, ddPCR and NGS detection simultaneously.Results:After excluding viral infections, the blood culture positive rate was 18.87%(10/53), the ddPCR positive rate was 47.17% (25/53), and the NGS positive rate was 41.51%(22/53). When using the ddPCR detection range as a reference, the ddPCR positivity rate was 98.11% (52/53), while the NGS positivity rate was 84.91%(45/53). There was a statistically significant difference in the positivity rate between the two groups ( P<0.05). Using blood culture as a reference, the sensitivity (60.00% vs 70.00%) and specificity (65.11% vs 69.77%) of ddPCR and NGS were in good agreement. In terms of pathogen detection, NGS had a wider detection range than ddPCR (34 species vs 21 species), and the difference was statistically significant (χ 2=55.000, P<0.001). In terms of time-consumption, blood culture took 66.93 h on average, while ddPCR was faster than NGS (about 4 h vs 20 h ). In terms of antimicrobial resistance (AMR) gene detection, five resistant strains were detected by both ddPCR and NGS, ddPCR detected two AMR genes, namely blaKPC and mecA, while NGS detected five AMR genes. Among them, except for blaKPC which was detected outside the target range in ddPCR, the other four AMR genes were also detected by ddPCR. Conclusions:Compared with blood culture, ddPCR and NGS have good application value in the etiological diagnosis of sepsis. Specifically, ddPCR has a higher detection rate of pathogens and takes less time. On the other hand, NGS has a wider detection range, especially for the discovery of some rare bacteria or pathogens that are difficult to be cultured routinely.
6.Synthesis and Identification of Saturated Arsenic-containing Hydrocarbons
Jia-Jia CHEN ; Ying-Xiong ZHONG ; Xin-Huang KANG ; Chun-Mei DENG ; Bing-Bing SONG ; Xiao-Fei LIU ; Zhuo WANG ; Rui LI ; Jian-Ping CHEN ; Xue-Jing JIA ; Sai-Yi ZHONG
Chinese Journal of Analytical Chemistry 2025;53(3):472-480
Arsenic is a semi-metal,and lipid-soluble arsenic compounds are one of the widespread forms in the environment and food chain,but there is a lack of standards for lipid-soluble arsenic compounds,which is one of the bottlenecks in the current analytical detection and toxicological studies of organic arsenic.In this study,four saturated arsenic-containing hydrocarbons,AsHC 318,AsHC 332,AsHC 346,and AsHC 374(The number is relative molecular mass),were successfully synthesized in three steps by using dimethylarsinic acid,potassium iodide,sodium hydroxide,and four brominated alkanes(1-Bromotetradecane,1-bromopentadecane,1-bromohexadecane,and 1-bromooctadecane)as raw materials.The structures of these four saturated arsenic-containing hydrocarbons were characterized by proton nuclear magnetic resonance(1H NMR)spectroscopy,13C nuclear magnetic resonance(13C NMR)spectroscopy,and high-resolution mass spectrometry(HR-MS).The yields of the method were 8%-10%,and the synthesized compounds could be used in subsequent toxicity evaluation experiments to assess the toxic effects and mechanisms of action of arsenic-containing hydrocarbons.This study provided an effective method for synthesis of arsenic-containing hydrocarbons,enriching the synthesis methods of arsenic-containing hydrocarbons,and provided raw materials for the subsequent toxicological studies of arsenic-containing hydrocarbons.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail