1.Application of femoral condyle sliding osteotomy in initial total knee arthroplasty.
Xin WANG ; Jian MA ; Songyan ZHANG ; Rui TAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):425-433
OBJECTIVE:
To investigate the effect of femoral condyle sliding osteotomy (FCSO) on the flexion gap and external rotation of the prosthesis in balancing coronal instability during initial total knee arthroplasty (TKA).
METHODS:
Between November 2021 and October 2024, FCSO technique was applied to balance the coronal medial and lateral spaces during initial TKA in 3 patients, including medial condyle sliding osteotomy (MCSO) and lateral condyle sliding osteotomy (LCSO). There were 1 male and 2 females with the age of 81, 68, and 68 years old. The affected knee has varus or valgus deformity, with tibia-femoral angles of 169.7°, 203.3°, and 162.2°, respectively. The hip-knee-ankle angle (HKA), range of motion (ROM), knee society scoring system (KSS), and pain visual analogue scale (VAS) score were used to evaluate joint function and pain relief. Based on model bone, the thickness and bone bed area of the medial and lateral femoral condyle osteotomy blocks in FCSO were measured. During TKA in 12 patients, the range of osteotomy block movement was evaluated. By simplifying the upward and forward movement of the osteotomy block into a geometric model, the impact of movement on the flexion gap and external rotation of the prosthesis was calculated.
RESULTS:
After application of FCSO during TKA, the limb alignment and medial and lateral balance at extension and flexion positions were restored in 3 patients. Three patients were followed up 23, 11, and 3 months, respectively. Postoperative HKA, pain VAS score, KSS score, and ROM all showed significant improvement compared to preoperative levels. The maximum thickness of osteotomy blocks by MCSO and LCSO was 17 and 12 mm, respectively. The simple upward movement of the osteotomy block mainly affected the extension gap, and had little effect on the flexion gap and external rotation of the prosthesis. Moving the osteotomy block forward at the same time had a significant impact on the flexion gap and external rotation of the prosthesis, especially on LCSO. Mild forward movement leaded to a decrease in external rotation of more than 3°, which had a serious impact on the patellar trajectory.
CONCLUSION
FCSO can effectively solve the problem of imbalance between the medial and lateral spaces during initial TKA, avoiding knee joint instability caused by excessive loosening and limiting the use of constrained condylar prosthesis. The distance for the downward movement of the osteotomy block in MCSO and LCSO was 3-5 mm and 6-8 mm, respectively, with 10-15 mm of space for forward movement and almost no space for backward movement. For MCSO, the upward and forward movement of the osteotomy block will increase the external rotation of the prosthesis, which is beneficial for improving the patellar trajectory and suitable for valgus knee. LCSO is suitable for varus knee, and the osteotomy block only slides vertically up and down without moving forward and backward.
Humans
;
Osteotomy/methods*
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Range of Motion, Articular
;
Femur/surgery*
;
Knee Joint/physiopathology*
;
Aged, 80 and over
;
Knee Prosthesis
;
Treatment Outcome
;
Osteoarthritis, Knee/surgery*
2.Expert consensus on the rational application of the biological clock in stomatology research
Kai YANG ; Moyi SUN ; Longjiang LI ; Zhangui TANG ; Guoxin REN ; Wei GUO ; Songsong ZHU ; Jia-Wei ZHENG ; Jie ZHANG ; Zhijun SUN ; Jie REN ; Jiawen ZHENG ; Xiaoqiang LV ; Hong TANG ; Dan CHEN ; Qing XI ; Xin HUANG ; Heming WU ; Hong MA ; Wei SHANG ; Jian MENG ; Jichen LI ; Chunjie LI ; Yi LI ; Ningbo ZHAO ; Xuemei TAN ; Yixin YANG ; Yadong WU ; Shilin YIN ; Zhiwei ZHANG
Journal of Practical Stomatology 2024;40(4):455-460
The biological clock(also known as the circadian rhythm)is the fundamental reliance for all organisms on Earth to adapt and survive in the Earth's rotation environment.Circadian rhythm is the most basic regulatory mechanism of life activities,and plays a key role in maintaining normal physiological and biochemical homeostasis,disease occurrence and treatment.Recent studies have shown that the biologi-cal clock plays an important role in the development of oral tissues and in the occurrence and treatment of oral diseases.Since there is cur-rently no guiding literature on the research methods of biological clock in stomatology,researchers mainly conduct research based on pub-lished references,which has led to controversy about the research methods of biological clock in stomatology,and there are many confusions about how to rationally apply the research methods of circadia rhythms.In view of this,this expert consensus summarizes the characteristics of the biological clock and analyzes the shortcomings of the current biological clock research in stomatology,and organizes relevant experts to summarize and recommend 10 principles as a reference for the rational implementation of the biological clock in stomatology research.
3.Evaluating the application efficiency of the MHSeqTyper47 kit in kinship identification
Lishuai TAN ; Xin JIN ; Yaosen FENG ; Kelai KANG ; Wenhua MA ; Mingguang LI ; Chi ZHANG ; Jie ZHAO ; Jian YE ; Le WANG
Chinese Journal of Forensic Medicine 2024;39(1):75-81
Objective To investigate the application value of the MHSeqTyper47 kit in kinship identification.Methods Multiplexed amplification and library preparation were performed for DNA samples from 113 related individuals by using the MHSeqTyper47 kit.The libraries were sequenced on a MiSeq FGx sequencer,and the data were analyzed using MHTyper for microhaplotype genotyping.The kinship indexes were calculated to evaluate the application efficiency of this kit in kinship identification and compared with those of the GlobalFilerTM kit.Results For the MHSeqTyper47 kit,the CPI values in trio identification were 1.43× 1011~6.15×1018.The CPI values in duo identification were 1.02× 105~1.53× 1013.The CFSI values in full sibling identification were 7.73×101~2.59×1016.Trios,duos and full siblings could be completely distinguished from unrelated pairs.The combined efficiency of these two kits in 2nd-degree kinship identification was 0.466 2.Conclusion The application value of MHSeqTyper47 kit is relatively higher in the identification of lst-degree kinships.If jointly used with the GlobalFilerrM kit,2nd-degree kinship identification could be achieved in some cases.
4.Influencing factors for colonoscopic compliance to colorectal cancer screening in outpatients
Xuejiao TAN ; Xin PENG ; Jian QIN ; Jiaxue LI ; Lina YE ; Ronghui PU ; Li LAI ; Jiajing MA ; Weigang CHEN
Chinese Journal of Digestive Endoscopy 2024;41(2):131-136
Objective:To explore the influencing factors for compliance to colonoscopy screening for colorectal cancer in outpatients.Methods:Patients aged 40-74 years who visited the outpatient gastroenterology department of 7 tertiary hospitals in 7 regions of Xinjiang from January 2022 to June 2022 were enrolled. Recommendations for colonoscopy screening were made according to the patient's medical conditions, and the questionnaire was used to collect information. The Chi-square test was used to compare the differences of compliant and non-compliant patients. Multivariate logistic regression was used to analyze the influencing factors of compliance to colonoscopy screening.Results:A total of 463 valid questionnaires were obtained from 7 centers, in which, 427 outpatients (92.2%) followed the recommendation for colonoscopy screening, and 36 (7.8%) did not. Chi-square test results showed that there were statistically significant differences between the two groups in gender, age, education, subjective cognition of intestinal polyps, personal history of colorectal polyps, family history of colorectal cancer, family history of colorectal polyps, abdominal pain or distension, and defecation habit or stool changes ( P<0.05). The results of multivariate regression analysis showed that the screening compliance of patients aged 40-49 years ( P=0.005, OR=0.141, 95% CI: 0.036-0.549) and 50-59 years ( P=0.039, OR=0.257, 95% CI: 0.071-0.932) was lower than that of patients aged 60-74 years. The screening compliance of patients with high school education ( P=0.011, OR=3.121, 95% CI: 1.304-7.473) and college education or above ( P=0.016, OR=3.544, 95% CI: 1.270-9.890) was higher than those with primary school education and below. Patients with personal history of colorectal polyps ( P=0.015, OR=12.288, 95% CI: 1.629-92.719), family history of colorectal cancer ( P=0.038, OR=8.506, 95% CI: 1.124-64.351) and changes in defecation habit or stool trait ( P=0.039, OR=4.794, 95% CI: 1.085-21.192) also had higher compliance. Conclusion:Age, educational level, personal history of colorectal polyps, and family history of colorectal cancer are related to colonoscopy screening compliance in outpatients of 7 tertiary hospitals in 7 regions of Xinjiang. The independent risk factors affecting compliance to colorectal cancer screening in outpatients are age of 40-59 years, lower educational level, no previous history of polyps or family history of colorectal cancer, and no defecation habit or stool changes.
5.Lessons and enlightments of health insurance drug renewal policy in some countries and regions
Xin-Ru HAN ; Kang-Ni ZENG ; Jia-Long TAN ; Jian WANG
Chinese Journal of Health Policy 2024;17(7):75-80
Objective:Summarizing and analyzing the rules of access and renewal of drugs in Australia,Japan,South Korea,and Chinese Taiwan,this paper aims to provide experience for the improvement of China's policy on national drug reimbursement list renewal.Methods:Through literature review,expert interviews,and other academic methods,it compares the different experience of drug renewal policy from the perspectives of the type,content,and renewal period.Results:Internationally representative national or regional medical insurance drug renewal policies are broadly categorized into single-drug price-volume agreements,joint price-volume agreements,and efficacy-based risk-sharing agreements.Conclusion:It is recommended that China should introduce new content such as joint measurement for renewal of exclusive drugs,combination consideration of quantity,price,and effectiveness,risk-sharing agreement for renewal of non-exclusive drugs,and placing an upper limit on the rate of reduction for the first renewal in its medical insurance policy.
6.Adverse Events in Total Artificial Heart for End-Stage Heart Failure:Insight From the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE)
Min Choon TAN ; Yong Hao YEO ; Jia Wei THAM ; Jian Liang TAN ; Hee Kong FONG ; Bryan E-Xin TAN ; Kwan S LEE ; Justin Z LEE
International Journal of Heart Failure 2024;6(2):76-81
Background and Objectives:
Real-world clinical data, outside of clinical trials and expert centers, on adverse events related to the use of SyncCardia total artificial heart (TAH) remain limited. We aim to analyze adverse events related to the use of SynCardia TAH reported to the Food and Drug Administration (FDA)’s Manufacturers and User Defined Experience (MAUDE) database.
Methods:
We reviewed the FDA’s MAUDE database for any adverse events involving the use of SynCardia TAH from 1/01/2012 to 9/30/2020. All the events were independently reviewed by three physicians.
Results:
A total of 1,512 adverse events were identified in 453 “injury and death” reports in the MAUDE database. The most common adverse events reported were infection (20.2%) and device malfunction (20.1%). These were followed by bleeding events (16.5%), respiratory failure (10.1%), cerebrovascular accident (CVA)/other neurological dysfunction (8.7%), renal dysfunction (7.5%), hepatic dysfunction (2.2%), thromboembolic events (1.8%), pericardial effusion (1.8%), and hemolysis (1%). Death was reported in 49.4% of all the reported cases (n=224/453).The most common cause of death was multiorgan failure (n=73, 32.6%), followed by CVA/other non-specific neurological dysfunction (n=44, 19.7%), sepsis (n=24, 10.7%), withdrawal of support (n=20, 8.9%), device malfunction (n=11, 4.9%), bleeding (n=7, 3.1%), respiratory failure (n=7, 3.1%), gastrointestinal disorder (n=6, 2.7%), and cardiomyopathy (n=3, 1.3%).
Conclusions
Infection was the most common adverse event following the implantation of TAH. Most of the deaths reported were due to multiorgan failure. Early recognition and management of any possible adverse events after the TAH implantation are essential to improve the procedural outcome and patient survival.
8.Analysis of anxiety and depressive status and influencing factors in patients with colorectal polyps in part of Xinjiang area
Xuejiao TAN ; Yaqiong PENG ; Xin PENG ; Miaomiao LUO ; Jian QIN ; Jiaxue LI ; Lina YE ; Ronghui PU ; Li LAI ; Jiajing MA ; Qinglin ZHANG ; Fang LIU ; Weigang CHEN
Chinese Journal of Digestion 2023;43(7):472-480
Objective:To investigated the prevalence of anxiety and depression symptoms in patients with colorectal polyps in part of Xinjiang area and to explore the associated influencing factors related to psychological status, and to provide evidence and clues to promote the diagnosis and treatment of psychosomatic diseases in digestive system.Methods:From December 2021 to June 2022, at the First Affiliated Hospital of Shihezi University, the Fourth Division Hospital of Xinjiang Production and Construction Corps, the Third Division Hospital of Xinjiang Production and Construction Corps (Kashgar Hospital), the Thirteenth Division Red Star Hospital of Xinjiang Production and Construction Corps, the Tenth Division Beitun Hospital of Xinjiang Production and Construction Corps, the Seventh Division Hospital of Xinjiang Production and Construction Corps, the Fifth Division Hospital of Xinjiang Production and Construction Corps, patients who underwent colonoscopy and colorectal polyps detected were enrolled. The generalized anxiety disorder scale-7 (GAD-7) was used to screen anxiety symptoms, and the patient health questionaire-8 (PHQ-8) was performed to screen depression symptoms, and the general situation questionnaire was used to collect clinical information of patients. The questionnairs were completed via the Questionnaire Star platform or paper questionnaire, and a database was established. The patients were divided into groups according to whether with anxiety and depression symptoms. Multivariable logistic regression models was performed to analyze the factors related to anxiety and depression.Results:A total of 516 questionnaires were distributed and collected, among which 9 questionnaires were incomplete and 507 questionnaires were valid, the effective rate of questionnaires was 98.26%. The detection rates of anxiety and depression symptoms in 507 patients with colorectal polyps were 21.50%(109/507) and 19.33%(98/507), respectively. The results of multivariable logistic analysis revealed that female ( OR=3.87, 95% confidence interval (95% CI) 2.30 to 6.51, P<0.001), maximum diameter of polyp ( OR=1.74, 95% CI 1.14 to 2.67, P=0.011), perception of polyps as cancer ( OR=13.96, 95% CI 1.48 to 132.07, P=0.022), and the occurrence of gastrointestinal symptoms after polyp detection ( OR=5.43, 95% CI 1.74 to 16.92, P=0.004) were independent risk factors of anxiety in patients with colorectal polyps. Female ( OR=2.42, 95% CI 1.47 to 4.00, P=0.001), the number of polyps ( OR=1.07, 95% CI 1.01 to 1.13, P=0.028) and the count of gastrointestinal symptoms ( OR=2.04, 95% CI 1.34 to 3.10, P=0.001) were independent risk factors of depression in patients with colorectal polyps. Conclusion:Gender, polyp size, number of polyps, disease perception, and concomitant gastrointestinal symptoms are associated with anxiety and depression in patients with colorectal polyps.
9.Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study
Tong TAN ; Hongxiang WU ; Bingqi FU ; Nianjin XIE ; Haijiang GUO ; Xin ZANG ; Xiaoyi LI ; Haozhong LIU ; Ruobing WANG ; Jian LIU ; Huanlei HUANG ; Jimei CHEN ; Jian ZHUANG ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(02):214-220
Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. Methods From November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. Results All patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. Conclusion Transcatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.
10.PROSI Mutation With Clinical Heterogeneity in Protein S Deficiency:Report of One Case.
Xin-Yu WEI ; Juan WANG ; Bang-Yun TAN ; Zi-Jian LI
Acta Academiae Medicinae Sinicae 2023;45(5):863-866
Reduced protein S activity is one of the high-risk factors for venous thromboembolism.Hereditary protein S deficiency is an autosomal dominant disorder caused by mutations in the PROS1 gene.We reported a female patient with a mutation of c.292 G>T in exon 3 of the PROS1 gene,which was identified by sequencing.The genealogical analysis revealed that the mutation probably originated from the patient's mother.After searching against the PROS1 gene mutation database and the relevant literature,we confirmed that this mutation was reported for the first time internationally.
Humans
;
Female
;
Protein S/genetics*
;
Protein S Deficiency/genetics*
;
Pedigree
;
Mutation

Result Analysis
Print
Save
E-mail