1.Effect and mechanism of Biejiajian Pill on subcutaneous xenograft tumor model of hepatocellular carcinoma Huh7 cells
Lu LU ; Huanling CHEN ; Jian XU ; Yuanqin DU ; Xiaoli LIU ; Yingsheng WU ; Chengting WU ; Wei BAN ; Jingjing HUANG ; Hongna HUANG
Journal of Clinical Hepatology 2026;42(1):125-133
ObjectiveTo investigate the inhibitory effect of Biejiajian Pills (BJJW) on the growth of liver cancer, as well as its potential mechanism in mediating the AMP-activated protein kinase (AMPK)/mammalian target of rapamycin (mTOR) pathway through mitochondrial energy metabolism. MethodsHuman hepatoma Huh7 cells were used to establish a nude mouse model of subcutaneous xenograft tumor. A total of 18 tumor-bearing nude mice were randomly divided into model group, BJJW group (2.2 g/kg), and metformin group (250 mg/kg), and the corresponding drug was given by gavage for 14 consecutive days. Tumor volume and weight were monitored during the experiment; HE staining was used to observe histopathological changes; the levels of reactive oxygen species (ROS) and adenosine triphosphate (ATP) in tumor tissue were measured; immunohistochemistry and Western blotting were used to measure the expression levels of proteins associated with the AMPK/mTOR pathway. A one-way analysis of variance was used for comparison of normally distributed continuous data between multiple groups, and the Tukey’s test was used for further comparison between two groups; the Kruskal-Wallis H test was used for comparison of non-normally distributed continuous data between multiple groups, and the Dunn’s test was used for further comparison between two groups. ResultsCompared with the model group, the BJJW group had a tumor inhibition rate of 45.73%, with significant reductions in both tumor volume and weight (P<0.01). Pathological examination showed that compared with the model group, the BJJW group had a significant reduction in the number of tumor cells and the presence of extensive necrosis. Mechanistic studies showed that compared with the model group, the BJJW group had a significant increase in ROS level (P<0.001) and a significant reduction in ATP level (P<0.001), as well as significant increases in p-AMPK/AMPK ratio (0.81±0.20 vs 0.13±0.04, P<0.01) and p-ULK1/ULK1 ratio (0.69±0.17 vs 0.18±0.13, P<0.01) and a significant reduction in p-mTOR/mTOR ratio (1.34±0.16 vs 3.20±0.62, P<0.01). ConclusionBJJW may inhibit the growth of liver cancer by inducing mitochondrial energy metabolism dysfunction, increasing the level of ROS, reducing the level of ATP, and activating the AMPK/mTOR signaling pathway.
2.Study on the efficacy and safety of Metformin hydrochloride enteric-coated capsules in patients with type 2 diabetes mellitus
Yiming WU ; Jian ZHANG ; Nan GU ; Qijuan DONG ; Ruiyun LIU ; Hong ZHANG ; Haixia LIU ; Yongcai ZHAO ; Lin CHENG ; Lianshan PU ; Fang BIAN ; Gang HE ; Quanmin LI ; Wei DU ; Zhaoling WANG ; Wei XU ; Liyong ZHONG ; Xiaohui GUO
Chinese Journal of Diabetes 2025;33(3):210-214
Objective To evaluate the efficacy and safety of enteric-coated metformin hydrochloride capsules(Junlida?)in patients with T2DM and poor glycemic control under lifestyle interventions.Methods In this study,419 patients with T2DM were recruited from 15 research centers from July 2020 to March 2022,and randomly divided into observation(Obs)group(n=209)and control group(Con,n=210)using a multicenter,randomized,double-blind,non-inferiority trial design.Patients in the Obs group were treated with enteric-coated Metformin hydrochloride capsules(Junlida?),and patients in the Con group were treated with Metformin hydrochloride tablets(Glucophage?).The optimal effective dose of 2 g/d was achieved within 4 weeks,and the reasonable dose was maintained until the end of treatment.The treatment period was 24 weeks.HbA1c and its compliance rate,FPG,and body weight were compared between the two groups in full analysis set(FAS)and protocol set(PPS).Safety and adverse events(AE)were evaluated in safety set(SS).Results A total of 414 participants were randomized(207 cases in Obs group and 207 cases in Con group).414 cases in FAS population(207 cases in Obs group and 207 cases in Con group),and 328 cases in PPS population(164 cases in Obs group and 164 cases in Con group),and 414 cases in SS population(207 cases in Obs group and 207 cases in Con group).After treatment,HbA1c,FPG and body weight were lower in both groups(P<0.05)in FAS and PPS.HbA1c compliance rate was not significantly different between the two groups in FAS and PPS(P>0.05).The results of non-inferiority test showed that the lower limit was>-0.4%in both FAS(-0.154,95%CI-0.384~0.069)and PPS(-0.139,95%CI-0.390~0.112),and the Obs group reached non-inferiority end point.The achievement rate,compliance rate,safety index and incidence of AE were not significantly different between the two groups(P>0.05).Conclusions Junlida? demonstrated non-inferiority to Glucophage? in glycemic control and can be safely and effectively used in patients with diabetes.
3.Application of Auto-prescription combined with low-dose contrast and iterative reconstruction algorithm in the CT angiography of thoracodorsal artery
Jian HE ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Deshuo DONG ; Zhiming MA ; Changyu DU
Journal of Practical Radiology 2025;41(5):861-865
Objective To explore the application value of Auto-prescription combined with low-dose contrast and adaptive statisti-cal iterative reconstruction-Veo(ASIR-V)algorithm in the computed tomography angiography(CTA)of thoracodorsal artery(TDA).Methods A total of 100 patients who underwent TDA CTA examination were prospectively selected.A tube voltage of 120 kVp and contrast agent of 1.5 mL/kg were used for group A(50 cases),and images were reconstructed with 40% post-set ASIR-V.The Auto-prescription for tube voltage and contrast agent of 1.2 mL/kg were used for group B(50 cases),while images were reconstruc-ted with 40%,60%,and 80% post-set ASIR-V,labeled as subgroups B1 to B3.The objective and subjective evaluation results of the images were compared between and within groups.Results Group A had an effective dose(ED)of 2.98(2.65,4.03)mSv,while group B had an ED of 1.92(1.44,3.33)mSv.The iodine intake in group B was lower than that in group A,and the CT value of the axillary artery in group B was significantly higher than that in group A(P<0.001).With the increased of ASIR-V level in group B,the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images gradually increased(P<0.05).In terms of subjec-tive scores on axial images,both subgroups B2 and B3 were superior to group A(P<0.001);with the increased of ASIR-V level in group B,subjective scores of axial images increased first and then decreased,among which subjective score of subgroup B2 was the highest and the differences were statistically significant(P<0.001).In terms of subjective scores on three-dimensional image quality,subgroups B1 to B3 were superior to group A(P<0.001).Conclusion The use of Auto-prescription combined with low-dose con-trast and 60% ASIR-V can significantly optimize the display of TDA,and reduce the radiation dose and contrast agent dose to a certain extent.
4.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.
5.The feasibility of bone mineral density screening using a proximal femur radiomics model derived from abdomen-pelvic CT scans
Changyu DU ; Yijun LIU ; Shigeng WANG ; Xiaoyu TONG ; Yong FAN ; Wei WEI ; Anliang CHEN ; Jian HE
Journal of Practical Radiology 2025;41(2):310-314
Objective To develop an automated bone mineral density(BMD)assessment model based on proximal femur images from abdomen-pelvic CT scans and to analyze its application value in opportunistic osteoporosis(OP)screening.Methods A retrospective selection was conducted on 351 patients who underwent abdomen-pelvic plain CT examination.The patients were randomly divided into training set(n=245)and test set(n=106)in a ratio of 7∶3.All images were transferred to a quantitative computed tomography(QCT)post-processing workstation to measure the BMD of the left proximal femur.According to the QCT BMD T-score,the patients were divided into osteoporosis(T-score-2.5),osteopenia(-2.5<T-score<-1)and normal bone density(T-score≥-1).The left proximal femur was dissected using an automatic segmentation model,and two three-class BMD assessment radiomics models were constructed using random forest(RF)and logistic regression(LR)classifiers,respectively.The receiver operating characteristic(ROC)curves were generated,and the area under the curve(AUC),sensitivity,specificity and other metrics were calculated to evaluate the diagnostic performance of the two models.The DeLong test was used to compare differences between the models.Results In the test set,the AUC of the RF and LR models for identifying osteoporosis were 0.953 and 0.954,respectively.The AUC for identifying osteopenia were 0.894 and 0.870,and the AUC for identifying normal bone density were 0.975 and 0.982,respectively.The comparison of model performance showed no statistically significant differences between the RF and LR models in identifying the three bone states in both the training and test sets(P>0.05).Conclusion Both the RF and LR radiomics models,constructed based on abdomen-pelvic plain CT scans,can be used for opportunistic BMD screening with high diagnostic efficiency.
6.Single nucleotide polymorphism typing of Yersinia pestis in natural plague foci around Qinghai Lake
Sheng LI ; Juan JIN ; Jian HE ; Xiao-yan YANG ; Ji-xiang BAI ; You-quan XIN ; Li ZHANG ; Xiao-lu ZHANG ; Wen-qi DU ; Wei LI
Chinese Journal of Zoonoses 2025;41(6):592-596
This study was aimed at determining the molecular characteristics of Yersinia pestis in the natural plague foci around Qinghai Lake through single nucleotide polymorphism technology,to lay a foundation for molecular epidemiological and source-tracing analysis of Y.pestis in this area.Using the whole genome sequencing technology,we obtained the whole genome sequences of 84 representative Y.pestis strains.Using the sequences of Y.pestis and Yersinia pseudotuberculosis IP32953 from the NCBI database as references,we compared and analyzed the 2 298 SNP loci of these strains.From 1957 to 2020,84 representative strains of Y.pestis from the natural plague foci around Qinghai Lake were divided into two clades:1.IN2 and 3.ANT1.The 1.IN2 clade was the characteristic population of Y.pestis throughout all epidemic years in this area.Additionally,analysis of the SNP distribution and hosts in the region indicated that the 1.IN2 clade was located in five counties except Wulan,whereas the 3.ANT1 clade was isolated from Himalayan marmot and dog in two counties.In conclusion,the population structure of SNP of Y.pestis in the natural plague foci around Qinghai Lake is relatively simple,and SNP analysis of Y.pestis provided a scientific basis for tracing plague epidemic sources and formulating plague prevention and control measures in this area.
7.Single nucleotide polymorphism typing of Yersinia pestis in natural plague foci around Qinghai Lake
Sheng LI ; Juan JIN ; Jian HE ; Xiao-yan YANG ; Ji-xiang BAI ; You-quan XIN ; Li ZHANG ; Xiao-lu ZHANG ; Wen-qi DU ; Wei LI
Chinese Journal of Zoonoses 2025;41(6):592-596
This study was aimed at determining the molecular characteristics of Yersinia pestis in the natural plague foci around Qinghai Lake through single nucleotide polymorphism technology,to lay a foundation for molecular epidemiological and source-tracing analysis of Y.pestis in this area.Using the whole genome sequencing technology,we obtained the whole genome sequences of 84 representative Y.pestis strains.Using the sequences of Y.pestis and Yersinia pseudotuberculosis IP32953 from the NCBI database as references,we compared and analyzed the 2 298 SNP loci of these strains.From 1957 to 2020,84 representative strains of Y.pestis from the natural plague foci around Qinghai Lake were divided into two clades:1.IN2 and 3.ANT1.The 1.IN2 clade was the characteristic population of Y.pestis throughout all epidemic years in this area.Additionally,analysis of the SNP distribution and hosts in the region indicated that the 1.IN2 clade was located in five counties except Wulan,whereas the 3.ANT1 clade was isolated from Himalayan marmot and dog in two counties.In conclusion,the population structure of SNP of Y.pestis in the natural plague foci around Qinghai Lake is relatively simple,and SNP analysis of Y.pestis provided a scientific basis for tracing plague epidemic sources and formulating plague prevention and control measures in this area.
8.Artificial intelligence in epidemiology: a decade-long bibliometric analysis
Conghui WANG ; Ziming YANG ; Wei SHI ; Chengwei XI ; Shucheng SI ; Liuliu WU ; Jian DU ; Shengfeng WANG ; Siyan ZHAN
Chinese Journal of Epidemiology 2025;46(9):1650-1659
Objective:To describe the hotspots and application trends of artificial intelligence (AI) in epidemiology in the past decade and analyze its advantages and challenges.Methods:The literatures with AI and epidemiology related keywords were systematically retrieved from Web of Science and China National Knowledge Infrastructure from 2014 to 2024. CiteSpace was used for bibliometric analysis of publication volume, keyword co-occurrence, clustering, emergence and cited literature co-occurrence analysis.Results:A total of 5 389 English papers and 1 659 Chinese papers were included, showing an increasing publication trend. High-frequency Chinese keywords included prediction, influencing factor, and machine learning, while English keywords frequently used were machine learning, prediction, and artificial intelligence. The Chinese keywords formed 14 clusters such as epidemiological characteristic, dietary pattern, and elderly individual, and the English keywords formed 21 clusters including prediction model, risk factor, and adult. In international studies, health policy, COVID-19, and digital health were the emerging frontier keywords. Eleven core papers were selected, covering key areas like traffic accident risk assessment, public health big data application, and deep learning in medical diagnosis.Conclusions:This study systematically summarized the research hotspots and development trends of AI applications in epidemiology over the past decade by using bibliometric methods, which indicated that current AI-based epidemiological studies are still in the exploratory phase, with the coexisting of both advantages and challenges. Continued attention should be paid to the future development of this field.
9.Deep learning image reconstruction algorithm combined with a large reconstruction matrix for low-dose CT screening of lung nodules
Changyu DU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN ; Yijun LIU
Journal of Practical Radiology 2025;41(11):1886-1890
Objective To explore the application value of deep learning image reconstruction(DLIR)algorithm combined with a large reconstruction matrix in lung nodules screening using low-dose computed tomography(LDCT)of the chest.Methods Patients who underwent LDCT scans were prospectively enrolled.The control group(group A)used the iterative reconstruction(IR)algorithm(Karl)with a reconstruction level of Karl 5,reconstructed images of 512×512(group A1)matrix,and 1 024 × 1 024(group A2)matrix.The experimental group employed DLIR combined with 512×512(group B)matrix and 1 024 × 1 024(group C)matrix for image reconstruction at levels 1-5,which were recorded as groups B1-5 and groups C1-5.The CT values and standard deviation(SD)values of the lung parenchyma and tracheal air were measured,and the signal-to-noise ratio(SNR)was calculated.The overall lung image quality was scored on a Likert 5-point scale,and the subgroup with the best lung image quality was selected.The lung nodule detec-tion rate and clarity were compared with group A1.Results Under the same reconstruction matrix,the CT values of the tracheal air and lung parenchyma in the experimental group showed no significant difference compared to the control group,while the SD values were lower and SNR were higher(P<0.05).Within groups B and C,as the DLIR level increased,the SD values of the tracheal air and lung paren-chyma gradually decreased,and SNR gradually improved(P<0.05).Subjective scores for the image quality in groups B and C initially increased and then decreased,with group B3 and group C4 showed the best image quality.No difference was observed in objective eval-uation between the two groups,but the subjective image quality score of group C4 was superior to group B3(P<0.05).Subjective eval-uation of lung nodule display in group C4 was better than in group A1(P<0.05).Conclusion DLIR algorithm combined with a large reconstruction matrix is feasible for lung nodules screening in chest LDCT,reducing image noise while improving lung nodules clarity,demonstrating significant clinical value.
10.The construction and application of a trauma limb salvage map in Shaanxi province.
Meng WANG ; Jian-Min LIU ; Xing-Bo DANG ; Long-Yang MA ; Gong-Liang DU ; Wei HU
Chinese Journal of Traumatology 2025;28(4):235-240
Trauma is an important cause of death in young- and middle-aged people. Trauma is comprehensive and includes many surgical specialties, and the surgical techniques of these specialties have long been mature. To reduce the mortality and disability rate of trauma patients, it is necessary to improve trauma management. Trauma has attracted attention in China and trauma treatment and care developed rapidly in recent years. To decrease traumatic mortality and disability rates, our team is committed to building an efficient trauma system in Shaanxi province and has successfully developed a trauma limb salvage map to address the high rates of amputation and disability in patients with limb injuries. This article elaborates on the construction experience of a trauma limb salvage map and its application details in Shaanxi province of China.
Humans
;
China
;
Limb Salvage/methods*
;
Wounds and Injuries/surgery*
;
Male
;
Extremities/injuries*
;
Adult
;
Amputation, Surgical
;
Middle Aged
;
Female

Result Analysis
Print
Save
E-mail