1.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effects of curcumol on iron death and epithelial-mesenchymal transition in hepatic stellate cells
Lei WANG ; Jin-Biao HUANG ; Yan-Qing HUANG ; Ze-Yu WANG ; Jia-Hui WANG ; Yang ZHENG ; Wei-Sheng LUO ; Tie-Jian ZHAO
The Chinese Journal of Clinical Pharmacology 2024;40(4):539-543
Objective To elucidate the effect of curcumol on hepatic stellate cell iron death and epithelial-mesenchymal transition(EMT),and to investigate the molecular mechanism of its anti-liver fibrosis effect.Methods A model of hepatic stellate cell activation was constructed using normal cultured hepatic stellate cells in vitro,and the cells were divided into blank group and experimental-L,-M,-H groups.The blank group was given DMEM complete culture solution for normal culture;the experimental-L,-M,-H groups were given DMEM complete culture solution containing 12.5,25.0 and 50.0 mg·L-1 curcumol for 48 h of intervention.The effects of curcumol on the proliferation of hepatic stellate cells was observed by CCK-8.The expression levels of glutathione peroxidase 4(GPX4)and solute carrier family 7 member 11(SLC7A11)were detected by Western blot.The expression levels of E-cadherin and N-cadherin were detected by immunofluorescence.Results The cell proliferation rates of the experimental-M,-H groups and blank group were(68.97±5.61)%,(61.91±4.40)%and(118.07±10.01)%;the relative expression levels of GPX4 were 0.37±0.04,0.28±0.03 and 0.58±0.05;the relative expression levels of SLC7A11 were 0.38±0.04,0.28±0.03 and 0.60±0.05;E-cadherin levels were 6.76±1.09,9.57±1.73 and 2.05±0.72;N-cadherin levels were 5.66±0.66,3.44±0.78 and 10.37±0.66.The differences of above indicators were statistically significant between the blank group and the experimental-M,-H groups(P<0.05,P<0.01).Conclusion Curcumol promotes iron death in hepatic stellate cells,thereby inhibiting hepatic stellate cell EMT,which may be its molecular mechanism to prevent and treat liver fibrosis.
8.Early outcomes of self-expanding interventional pulmonary valve in transthoracic implantation: A prospective clinical study
Ying HUANG ; Ziqin ZHOU ; Yong ZHANG ; Xiaohua LI ; Nianjin XIE ; Hongwen FEI ; Hui LIU ; Junfei ZHAO ; Jian ZHUANG ; Jimei CHEN ; Shusheng WEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):872-877
Objective To evaluate early outcomes of transthoracic pulmonary valve implantation for the treatment of moderate and severe pulmonary regurgitation by using homemade self-expanding valve (SalusTM). Methods Patients with severe pulmonary regurgitation who underwent transthoracic pulmonary valve implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to November 25, 2022 were prospectively enrolled. The early postoperative complications and improvement of valve and heart function were summarized and analyzed. Results A total of 25 patients were enrolled, including 16 males and 9 females, with an average age of 24.5±1.5 years and an average weight of 57.0±3.0 kg. The mean systolic diameters of the bifurcation near the main pulmonary artery, the stenosis of the middle segment of the aorta and near the valve of the right ventricular outflow tract of the patients were 31.8±7.4 mm, 30.6±5.9 mm and 38.4±8.0 mm, respectively. All patients were successfully implanted with valves, and there were no serious complications such as death, coronary compression, stent fracture, valve displacement and infective endocarditis in the early postoperative period. The indexed left atrial longitudinal diameter, indexed right atrial longitudinal diameter, and indexed right ventricular outflow tract anteroposterior diameter decreased significantly after the operation. The degree of tricuspid and pulmonary valve regurgitation and the indexed regurgitation area decreased significantly. The above differences were statistically significant (P<0.05). Conclusion The early outcomes of transthoracic pulmonary valve implantation with homemade self-expanding pulmonary valve (SalusTM) in the treatment of severe pulmonary regurgitation is relatively good, and the long-term outcomes need to be verified by the long-term follow-up studies with large samples.
9.Domestic self-expanding interventional pulmonary valve stent in transthoracic implantation for pulmonary valve regurgitation: A prospective cohort study
Ziqin ZHOU ; Taoran HUANG ; Naijimuding ABUDUREXITI ; Yong ZHANG ; Haiyun YUAN ; Nianjin XIE ; Hongwen FEI ; Hui LIU ; Jian ZHUANG ; Jimei CHEN ; Shusheng WEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1305-1312
Objective To analyze and summarize the early and medium-term outcomes of self-expanding interventional pulmonary valve stent (SalusTM) for right ventricular outflow tract dysfunction with severe pulmonary valve regurgitation. Methods We established strict enrollment and follow-up criteria. Patients who received interventional pulmonary valve in transthoracic implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to July 18, 2023 were prospectively included, and all clinical data of patients were collected and analyzed. Results A total of 38 patients with severe pulmonary regurgitation were included, with 23 (60.5%) males and 15 (39.5%) females. The mean age was 24.08±8.12 years, and the mean weight was 57.66±13.54 kg. The preoperative mean right ventricular end-diastolic volume index (RVEDVI) and right ventricular end-systolic volume index (RVESVI) were 151.83±42.84 mL/m2 and 83.34±33.05 mL/m2, respectively. All patients successfully underwent transcatheter self-expandable pulmonary valve implantation, with 3 (7.9%) patients experiencing valve stent displacement during the procedure. Perioperative complications included 1 (2.6%) patient of postoperative inferior wall myocardial infarction and 1 (2.6%) patient of poor wound healing. The median follow-up time was 12.00 (6.00, 17.50) months. During the follow-up period, there were no deaths or reinterventions, and no patients had recurrent severe pulmonary regurgitation. Three (7.9%) patients experienced chest tightness and chest pain, and 1 (2.6%) patient developed frequent ventricular premature beats. Compared with preoperative values, the right atrial diameter, right ventricular diameter, and tricuspid annular plane systolic excursion were significantly reduced at 6 months and 1 year postoperatively, with improvement in the degree of pulmonary regurgitation (P<0.01). Compared with preoperative values, RVEDVI and RVESVI decreased to 109.51±17.13 mL/m2 and 55.88±15.66 mL/m2, respectively, at 1 year postoperatively (P<0.01). Conclusion Self-expanding interventional pulmonary valve in transthoracic implantation is safe and effective for severe pulmonary valve regurgitation and shows good clinical and hemodynamic results in one-year outcome.
10.Investigation of metabolites of 2-methyl-dechloroketamine in vitro
Jun-hui RU ; Feng HUANG ; Hao WU ; Min-hao WANG ; Xing KE ; Jian-hong GAO ; Yi-lei FAN
Acta Pharmaceutica Sinica 2024;59(5):1357-1363
The abuse of novel phenylcyclohexylpyridine drugs poses a significant threat to societal safety. The novel psychoactive substance 2-methyl-deschloroketamine (2-MDCK), belonging to the phenylcyclohexylpyridine class, has recently surfaced as a new compound. However, there is a lack of understanding regarding its metabolic pathways and the identification of suitable biomarkers. In this study, a human liver microsomal model was established, and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) technology was applied to investigate the