1.Evaluation of different detection methods for decline pattern of syphilis antibody in non-congenital syphilis children
Jingxuan XU ; Wenhong PENG ; Jiali WANG ; Yunfang QIAN ; Xianhua ZHAO ; Ning LENG ; Yong YANG ; Lei CHU ; Erfu XIE
Chinese Journal of Clinical Laboratory Science 2025;43(2):88-91
Objective To explore the application values of different detection methods in monitoring the decline pattern of syphilis-spe-cific antibody in the non-congenital syphilis children.Methods A total of 80 non-congenital syphilis children were included in the study.The serum specimens were collected after birth,and the syphilis-specific antibodies were detected using electrochemilumines-cence immunoassay(ECLIA),western blotting(WB),treponema pallidum particle agglutination assay(TPPA),enzyme-linked im-munosorbent assay(ELISA),and toluidine red unheated serum test(TRUST).Follow-up was conducted every three months until the positive results of ELISA and TRUST turned to negative.Results The results of ECLIA showed that the syphilis-specific antibody lev-els in the non-congenital syphilis children declined to 25%of the level at birth within 2 to 3 months,and the rate of decline was inde-pendent of the initial concentration.WB analysis indicated that the specific IgG bands in non-congenital syphilis children at birth were consistent with those of their mother,and the sequence of specific antibodies decline was as follows:TPN47,TPN15,TPN45,and TPN17.Due to methodological limitations,the absorbance values of ELISA showed no significant change during the first three months after birth when high concentrations of antibodies were present in the samples,but it showed high sensitivity in the detection for the samples with low-concentration of syphilis antibodies.The detection rates of ECLIA,TPPA,and WB were compared by using ELISA as the reference method.At birth,the detection rates of syphilis antibodies were 100%,100%,and 90%,respectively.In 3 months after birth,the detection rates were 100%,100%,and 75%.In 6 months after birth,,they were 100%,46%,and 15%.In 9 months after birth,they were 83%,33%,and 0%.The positive rate of TRUST was 17.5%at birth.and turned to negative in 3 month of follow-up.Conclusion Syphilis specific IgG antibodies may fully transferred to the fetus and decline in a predictable pattern after birth.The comprehensive analysis for the results of the four methods suggested that dynamic detection using ECLIA method could be used to pre-dict the risk of non-congenital syphilis or terminate the follow-up at 3 months,while the seroconversion detected by WB was earlier than that by TPPA,while ELISA required the longest follow-up period.
2.Evaluation of different detection methods for decline pattern of syphilis antibody in non-congenital syphilis children
Jingxuan XU ; Wenhong PENG ; Jiali WANG ; Yunfang QIAN ; Xianhua ZHAO ; Ning LENG ; Yong YANG ; Lei CHU ; Erfu XIE
Chinese Journal of Clinical Laboratory Science 2025;43(2):88-91
Objective To explore the application values of different detection methods in monitoring the decline pattern of syphilis-spe-cific antibody in the non-congenital syphilis children.Methods A total of 80 non-congenital syphilis children were included in the study.The serum specimens were collected after birth,and the syphilis-specific antibodies were detected using electrochemilumines-cence immunoassay(ECLIA),western blotting(WB),treponema pallidum particle agglutination assay(TPPA),enzyme-linked im-munosorbent assay(ELISA),and toluidine red unheated serum test(TRUST).Follow-up was conducted every three months until the positive results of ELISA and TRUST turned to negative.Results The results of ECLIA showed that the syphilis-specific antibody lev-els in the non-congenital syphilis children declined to 25%of the level at birth within 2 to 3 months,and the rate of decline was inde-pendent of the initial concentration.WB analysis indicated that the specific IgG bands in non-congenital syphilis children at birth were consistent with those of their mother,and the sequence of specific antibodies decline was as follows:TPN47,TPN15,TPN45,and TPN17.Due to methodological limitations,the absorbance values of ELISA showed no significant change during the first three months after birth when high concentrations of antibodies were present in the samples,but it showed high sensitivity in the detection for the samples with low-concentration of syphilis antibodies.The detection rates of ECLIA,TPPA,and WB were compared by using ELISA as the reference method.At birth,the detection rates of syphilis antibodies were 100%,100%,and 90%,respectively.In 3 months after birth,the detection rates were 100%,100%,and 75%.In 6 months after birth,,they were 100%,46%,and 15%.In 9 months after birth,they were 83%,33%,and 0%.The positive rate of TRUST was 17.5%at birth.and turned to negative in 3 month of follow-up.Conclusion Syphilis specific IgG antibodies may fully transferred to the fetus and decline in a predictable pattern after birth.The comprehensive analysis for the results of the four methods suggested that dynamic detection using ECLIA method could be used to pre-dict the risk of non-congenital syphilis or terminate the follow-up at 3 months,while the seroconversion detected by WB was earlier than that by TPPA,while ELISA required the longest follow-up period.
3.The feasibility and safety of simultaneous bilateral adrenal vein sampling using 4F-MPA1 catheter via right elbow vein access:preliminary results in 51 patients
Qingan LI ; Qinghe WANG ; Ming YU ; Luhong LI ; Junwei WEN ; Shuangyu SHEN ; Jiali CHU ; Junxia WU ; Yi JIN ; Yuanhao LI
Journal of Interventional Radiology 2024;33(2):176-181
Objective To discuss the feasibility and safety of simultaneous bilateral adrenal vein sampling(AVS)using two 4F-MPA1 catheters via right elbow vein access.Methods A total of 51 consecutive patients with primary aldosteronism,who received simultaneous bilateral AVS using two 4F-MPA1 catheters(one of the two catheters was shaped into pig tail figure)via right elbow vein access at Xiangyang Municipal Central Hospital between October 2021 and October 2022,were enrolled in this study.The used catheter,the success rate of simultaneous bilateral AVS,and the incidence of complications rate were calculated.Results The 4F-MPA1 catheter was used for all of the right AVS,while a specially shaped 4F-MPA1 catheter was used for the main trunk vein AVS of the left adrenal gland and the central vein AVS of the left adrenal gland.The success rate of simultaneous bilateral AVS was 92.2%(47/51).Adrenal hematoma occurred in one patient(1.96%).Conclusion The technique of simultaneous bilateral AVS using two 4F-MPA1 catheters via right elbow vein access is simple to operate,less traumatic,and clinically safe and feasible.However,due to the small sample used in this study,the clinical value of this technique still needs further investigation and verification.