1.Dosimetric comparison of 4 different volumetric modulated arc therapy plans for hippocampal-sparing prophylactic cranial irradiation
Meijiao WANG ; Jiacheng LIU ; Kaining YAO ; Yichen PU ; Jian GONG ; Fan JIANG ; Yi DU
Chinese Journal of Medical Physics 2025;42(7):853-862
Objective To quantitatively compare the dosimetric differences among 4 volumetric modulated arc therapy(VMAT)plans by analyzing the number of arcs and collimator angle settings,aiming to establish a standardized planning template for hippocampal-sparing prophylactic cranial irradiation(HS-PCI)in clinic and improve both planning quality and clinical efficiency.Methods Twenty HS-PCI patients were enrolled,with 4 VMAT plans(V2c,V2p,V3,and V4)for each patient.The differences in target dose,organs-at-risk dose,and monitor units were compared.Results V4 plan had the highest PTV D98%and V95%,and the differences of PTV D98%in V2c vs V2p,V2c vs V4,and PTV V95%in V2c vs V4 were statistically significant(P<0.05).Meanwhile,V4 plan had the lowest PTV Dmax and Dmin doses.Specifically,statistically significant differences were observed in PTV Dmax in V4 vs V2c,V4 vs V2p,V4 vs V3,as well as PTV Dmin in V2c vs V2p,V2c vs V3,V2c vs V4,V2p vs V4(P<0.05).The PTV Dmean was the highest in V2p plan,with statistically significant differences observed in V2c vs V2p,V2c vs V4,V2p vs V3,and V3 vs V4(P<0.05).The highest PTV D2%dose was observed in V2p plan,and the differences in V2c vs V2p,V2c vs V4,V2p vs V3,V3 vs V4 were statistically significant(P<0.05).The homogeneity index and conformity index were close in 4 plans(P=0.946,P=0.380).V4 plan had the lowest Dmax,Dmean,and Dmin of the hippocampus,with significant differences in hippocampal Dmax in V4 vs V2c,V4 vs V2p,hippocampal Dmean in V4 vs V2c,V4 vs V2p,V3 vs V2c,and hippocampal Dmin in V2c vs V2p/V3/V4,and V4 vs V2p(P<0.05).V3 plan had the lowest Dmax for bilateral lenses,and V4 plan showed the lowest Dmax for lenses with a 3 mm expansion,with significant differences between V2c and V2p/V3/V4(P<0.05).V4 plan had the lowest dose for the right optic nerve,with significant differences in V4 vs V2p,and V4 vs V3(P<0.05).No significant differences were observed for the left optic nerve and optic chiasm.The monitor units in V2p plan was the lowest.Conclusion When differences in organs-at-risk doses and plan quality parameters are insignificant,V2p plan is recommended as it can ensure treatment quality while reducing delivery time.
2.Dosimetric comparison of 4 different volumetric modulated arc therapy plans for hippocampal-sparing prophylactic cranial irradiation
Meijiao WANG ; Jiacheng LIU ; Kaining YAO ; Yichen PU ; Jian GONG ; Fan JIANG ; Yi DU
Chinese Journal of Medical Physics 2025;42(7):853-862
Objective To quantitatively compare the dosimetric differences among 4 volumetric modulated arc therapy(VMAT)plans by analyzing the number of arcs and collimator angle settings,aiming to establish a standardized planning template for hippocampal-sparing prophylactic cranial irradiation(HS-PCI)in clinic and improve both planning quality and clinical efficiency.Methods Twenty HS-PCI patients were enrolled,with 4 VMAT plans(V2c,V2p,V3,and V4)for each patient.The differences in target dose,organs-at-risk dose,and monitor units were compared.Results V4 plan had the highest PTV D98%and V95%,and the differences of PTV D98%in V2c vs V2p,V2c vs V4,and PTV V95%in V2c vs V4 were statistically significant(P<0.05).Meanwhile,V4 plan had the lowest PTV Dmax and Dmin doses.Specifically,statistically significant differences were observed in PTV Dmax in V4 vs V2c,V4 vs V2p,V4 vs V3,as well as PTV Dmin in V2c vs V2p,V2c vs V3,V2c vs V4,V2p vs V4(P<0.05).The PTV Dmean was the highest in V2p plan,with statistically significant differences observed in V2c vs V2p,V2c vs V4,V2p vs V3,and V3 vs V4(P<0.05).The highest PTV D2%dose was observed in V2p plan,and the differences in V2c vs V2p,V2c vs V4,V2p vs V3,V3 vs V4 were statistically significant(P<0.05).The homogeneity index and conformity index were close in 4 plans(P=0.946,P=0.380).V4 plan had the lowest Dmax,Dmean,and Dmin of the hippocampus,with significant differences in hippocampal Dmax in V4 vs V2c,V4 vs V2p,hippocampal Dmean in V4 vs V2c,V4 vs V2p,V3 vs V2c,and hippocampal Dmin in V2c vs V2p/V3/V4,and V4 vs V2p(P<0.05).V3 plan had the lowest Dmax for bilateral lenses,and V4 plan showed the lowest Dmax for lenses with a 3 mm expansion,with significant differences between V2c and V2p/V3/V4(P<0.05).V4 plan had the lowest dose for the right optic nerve,with significant differences in V4 vs V2p,and V4 vs V3(P<0.05).No significant differences were observed for the left optic nerve and optic chiasm.The monitor units in V2p plan was the lowest.Conclusion When differences in organs-at-risk doses and plan quality parameters are insignificant,V2p plan is recommended as it can ensure treatment quality while reducing delivery time.
3.Bioinformatics analysis of HBV s gene mutation in blood donor
Jiacheng FAN ; Qing LI ; Xiuli CHEN ; Shixiang LIU ; Ye CHEN
Chinese Journal of Blood Transfusion 2024;37(8):933-939
Objective To analyze the infectious indicators,HBV s gene mutations and changes in bioinformatics char-acteristics of HBV DNA+/HBsAg-blood donor.Methods A sample of HBV DNA+/HBsAg-was screened by PCR meth-od,and HBsAg/HBsAb/HBeAg/HBeAb/HBcAb of HBV in the sample were detected by ELISA and chemiluminescence methods.The mutation of the HBVs gene fragment in the sample was sequenced and analyzed,and the bioinformatics analy-sis was performed using analysis software.Results The sample showed HBV DNA+,HBsAg-,HBsAb+,HBeAg+,HBe-Ab-and HBcAb+,with an amino acid unit point mutation(P151L)occurred in the HBV s gene,and the spatial structure changed.Conclusion The spatial structural changes in the gene sequence of HBVs may be the reason for the appearance of serological HBsAg-/HBsAb+/HBV DNA+in the test results.
4.Ghrelin affects feed intake and body weight of mice through CART neurons in lat-eral hypothalamic nucleus
Xiaojuan CAO ; Haodong LIU ; Penghui LI ; Jiacheng LI ; Qi FAN ; Xing WANG ; Yu-Jie CHEN ; Rihan HAI ; Xiaoyu ZHANG ; Chenguang DU
Chinese Journal of Veterinary Science 2024;44(6):1268-1273
Ghrelin is a hormone produced by the stomach that regulates energy metabolism after acting on the central nervous system.Cocaine amphetamine-regulated transcriptional peptide(CART)neurons participate in the regulation of feeding behavior and energy balance.It is known that CART neurons are influenced by hormones to regulate energy homeostasis,but whether ghre-lin exerts its pro-appetite function by influencing CART neurons is unknown.Therefore,this study focuses on the role of VMHCART neurons in the regulation of feeding and relative body weight by ghrelin.Firstly,the whole brain expression of CART was determined by immunofluorescence.Then the effect of intraperitoneal injection of ghrelin on the expression of DMHCART neurons was evalua-ted.Finally,the ghrelin was delivered to DMH and the changes of food intake and relative body weight of mice were measured.CART immunoreactive neurons were detected in medial preoptic nucleus(MPA),arcuate nucleus(ARC),dorsomedial hypothalamic nucleus(DMH),thalamic pa-raventricular nucleus(PVT)and raphe nucleus(ROb).Compared with the control group,periph-eral injection of ghrelin significantly increased the expression of DMHC ART immunoreactive neurons(P=0.037 3).DMH long-term injection of ghrelin resulted in an increase in body weight(P=0.004 0)and feed intake(P=0.023 1).The results provide anatomical evidence for the whole brain distribution of CART,which proves that ghrelin affects feed intake and body weight of mice through CART neurons in DMH,suggesting that specific neuron types and regional specificity are involved in ghrelin regulation of feed intake and energy homeostasis.
5.Projection pathway of VGlut2 neurons from paraventricular nucleus
Xing WANG ; Haodong LIU ; Penghui LI ; Jiacheng LI ; Qi FAN ; Rui YAN ; Yang HE ; Ming ZHANG ; Xin ZHOU ; Chenguang DU
Chinese Journal of Veterinary Science 2024;44(7):1514-1520
Vesicular glutamate transporter 2(VGlut2)is expressed in the PVN of the hypothalamic paraventricular nucleus(PVNVG1ut2)as an excitatory neurotransmitter,which regulates food intake and energy metabolism and plays an important role in maintaining homeostasis.However,it is not clear that the upstream and downstream projection network of PVNVGut2 neurons hinders the anal-ysis of glutamatergic neuron circuit function.Anterograde and retrograde tracer viruses were injec-ted into the PVN of VGlut2 mice by stereotactic brain injection technique to find the input and output nuclei of PVNVGlut2 neurons.Anterograde tracing results showed that PVNVGlut2 neurons pro-jected to the downstream medial amygdala(MeAD)and arcuate nucleus(ARC).Retrograde trac-ing results showed that PVNVGlut2 received input from the prefrontal nucleus(Pr),the reticular tegmental nucleus(RtTg),and the hypoglossal nucleus(12N).In addition,VGlut2 was found to be co-expressed with neuronal nitric oxide synthase(nNOS)neurons in the PVN.The anatomical net-work of PVNVG1ut2 neurons was analyzed by virus tracking tool,which laid the anatomical founda-tion for further study on the functional regulation of PVNVGlut2.
6.Locking compression plating for treatment of periprosthetic distal femur fractures in the aged
Yake LIU ; Zhenyu ZHOU ; Ran TAO ; Yi CAO ; Jianwei ZHU ; Youhua WANG ; Yue LU ; Hua XU ; Jiacheng XU ; Hongdong MA ; Jining SHEN ; Fengxiang ZHAO ; Kefan WU ; Fan LIU
Chinese Journal of Orthopaedic Trauma 2024;26(9):790-796
Objective:To explore the clinical outcomes of locking compression plating (LCP) in the treatment of periprosthetic fracture (PPF) of the distal femur in the aged patients.Methods:A retrospective study was performed to analyze the 31 aged patients who had been treated at Department of Orthopedic Surgery, The Affiliated Hospital to Nantong University for PPF of the distal femur with LCP between June 2012 and May 2023. There were 27 females and 4 males with an age of (80.2±6.1) years. According to the Unified Classification System (UCS), 18 PPFs were classified as type Ⅴ.3B1 and 6 PPFs as type Ⅴ.3B2 after total knee arthroplasty and 7 PPFs as type Ⅳ.3C after total hip arthroplasty. The patients were fixated with a lateral single plate in 25 cases, and with lateral and medial dual plates in 6 cases. The surgical time, intraoperative blood loss, hospitalization time, postoperative weight-bearing time, fracture healing time, and knee joint function and complications during follow-up were recorded.Results:For the 25 patients undergoing fixation with a lateral single plate, the surgical time was (58.7±7.9) minutes, the intraoperative blood loss (78.0±15.1) mL, the hospitalization time (6.9±1.6) days, the postoperative weight-bearing time (5.9±1.4) days, and the follow-up time 37 (15, 51) months. For the 6 patients undergoing fixation with lateral and medial dual plates, the surgical time was (186.6±9.8) minutes, the intraoperative blood loss (1,256.7±231.2) mL, the hospitalization time (17.8±3.3) days, the postoperative weight-bearing time (3.6±0.6) days, and the follow-up time 17 (16, 21) months. The fracture healing time was (14.9±2.0) and (18.7±2.6) weeks, respectively, for patients fixed with single and double steel plates. By the scoring criteria of the American Hospital for Special Surgery (HSS), the knee joint function was evaluated at the last follow-up as excellent in 10 cases and as good in 15 cases for the 25 patients undergoing fixation with a lateral single plate, and as good for all the 6 patients undergoing fixation with lateral and medial dual plates. No patient experienced such complications as incision infection, bone nonunion, or internal fixation failure during the follow-up period.Conclusions:LCP fixation can achieve satisfactory outcomes in the treatment of PPF of the distal femur in the aged patients. As fixation with a single lateral femoral plate is suitable for most of the aged patients with PPF of the distal femur, it can be used as the first choice. Fixation with dual plates can provide stronger stability, but its indications should be strictly controlled.
7.Clinical features and progress in diagnosis and treatment of mild autonomous cortisol secretion
Shiming WANG ; Weiwei FAN ; Jiacheng JIN ; Xinqing HAO ; Jianbo WANG
Chinese Journal of Urology 2024;45(4):325-328
Mild autonomous cortisol secretion (MACS) is a condition indicated by biochemical testing for autonomous cortisol secretion, yet it lacks the classical signs of Cushing's Syndrome, such as moon face, buffalo hump, plethoric appearance, and purple striae. It is predominantly observed in middle-aged women and is commonly associated with adrenal incidentalomas. Due to the lack of significant clinical signs, the diagnosis of MACS primarily relies on hormonal testing. Patients with MACS often present with comorbidities such as hypertension, diabetes, and osteoporosis. For those with comorbid conditions, surgical treatment is the principal therapeutic approach. This article summarizes recent national and international guidelines and research to elucidate the updates to the diagnostic criteria for MACS, with a particular focus on the interpretation of the 1 mg overnight dexamethasone suppression test results. It also details the treatment and follow-up strategies for MACS. Furthermore, the article highlights the urgent need for more extensive prospective studies to refine the existing diagnostic criteria and to develop surgical guidelines for a wider range of patients with MACS.
8.Amylin regulates feeding through locus coeruleus
Qi FAN ; Haodong LIU ; Penghui LI ; Jiacheng LI ; Xing WANG ; Chenguang DU
Chinese Journal of Veterinary Science 2024;44(12):2605-2611
Amylin exerts a satiety-limiting effect on food intake by influencing the regulation of en-ergy metabolism in the central nucleus.However,the binding sites of amylin are widely distributed throughout the central nervous system,and it remains unclear whether the locus coeruleus(LC)responds to amylin stimulation.Therefore,this experiment aims to confirm whether amylin exerts its inhibitory effect on food intake through the LC following localized damage to the LC nucleus.The results indicate that amylin,while suppressing appetite,activates c-Fos neurons and tyrosine hydroxylase(TH)within the LC,leading to increased heat production in the interscapular brown adipose tissue(IBAT)of mice.However,after LC damage,the central feeding inhibition mediated by amylin is alleviated,although it is weaker compared to the group with solely LC damage,and the thermogenic capacity of IBAT is reduced.Thus,the study demonstrates that the LC is also one of the sites of action for exogenous amylin and is crucial for maintaining amylin-induced thermo-genesis.These findings expand the understanding of amylin's central actions and ultimately provide potential targets for obesity treatment.
9.Acceptance and commissioning tests for big bore CT simulator and quality control scheme
Meijiao WANG ; Jiacheng LIU ; Kaining YAO ; Jian GONG ; Zhongsu FENG ; Fan JIANG ; Shun ZHOU ; Yichen PU ; Jixiang CHEN ; Hao WU ; Yi DU
Chinese Journal of Medical Physics 2024;41(12):1460-1472
CT simulator has the functions such as original coordination positioning and radiotherapy resetting,and it can provide image and cooridiate information for radiotherapy.Through electronic density calibration,tissue inhomogeneity correction is carried out for supporting dose calculation in treatment planning system.With reference to relevant national standards,international guidelines,clinical functions of CT simulator and the practical experience of the center,a set of acceptance and commissioning testing scheme suitable for big bore CT simulator is presented,aiming to guide and assist the newly opened department in conducting comprehensive,safe and feasible acceptance and commissioning tests.The scheme includes the reference methods and tolerance standards of CT simulator machinery,image quality,radiation dose,radiotherapy related items and safety,so as to ensure the safety and accuracy of CT simulation and survival benefits.
10.Acceptance and commissioning tests for big bore CT simulator and quality control scheme
Meijiao WANG ; Jiacheng LIU ; Kaining YAO ; Jian GONG ; Zhongsu FENG ; Fan JIANG ; Shun ZHOU ; Yichen PU ; Jixiang CHEN ; Hao WU ; Yi DU
Chinese Journal of Medical Physics 2024;41(12):1460-1472
CT simulator has the functions such as original coordination positioning and radiotherapy resetting,and it can provide image and cooridiate information for radiotherapy.Through electronic density calibration,tissue inhomogeneity correction is carried out for supporting dose calculation in treatment planning system.With reference to relevant national standards,international guidelines,clinical functions of CT simulator and the practical experience of the center,a set of acceptance and commissioning testing scheme suitable for big bore CT simulator is presented,aiming to guide and assist the newly opened department in conducting comprehensive,safe and feasible acceptance and commissioning tests.The scheme includes the reference methods and tolerance standards of CT simulator machinery,image quality,radiation dose,radiotherapy related items and safety,so as to ensure the safety and accuracy of CT simulation and survival benefits.

Result Analysis
Print
Save
E-mail