1.Construction and characterization of recombinant human coagulation factor Ⅶ stable transfected cell lines
Xiaoxiao LI ; Jiabin CHEN ; Jiajun LIU ; Zhifei ZHANG ; Sen ZOU ; Lihua ZHU ; Zhaoyong YANG
Acta Universitatis Medicinalis Anhui 2026;61(1):16-22
ObjectiveTo construct a stable monoclonal human embryonic kidney 293 (HEK293) cell line expressing recombinant human coagulation factor Ⅶ (rhFⅦ) and evaluate the expression level and procoagulant bioactivity of rhFⅦ. MethodsThe plasmid pCDNA3.1-EGFP-FⅦ was transfected into HEK293 cells to verify the effectiveness of the transfection system. The plasmid pCDNA3.1-FⅦ was transfected into HEK293 cells, and monoclonal stable transfected cell lines were selected using geneticin (G418). The transcription of the FⅦ gene was identified by reverse transcription polymerase chain reaction (RT-PCR). The expression level of rhFⅦ in the supernatant of the monoclonal stable transfected cell line was detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot. The concentration of rhFⅦ was determined by enzyme-linked immunosorbent assay (ELISA), and the procoagulant activity of rhFⅦ was measured by human coagulation factor Ⅶ potency assay. ResultsHEK293 cells transfected with pcDNA3.1-EGFP-FⅦ showed green fluorescence, indicating that rhFⅦ was successfully expressed in the supernatant of HEK293 cells after transient transfection with pcDNA3.1-FⅦ. The monoclonal stable transfected cell line was obtained by G418 screening. RT-PCR identified that the FⅦ gene was integrated into the genome of the monoclonal stable transfected cell line. The cell viability was good as detected by Cell Counting Kit-8, and a single band of rhFⅦ was obtained by purification of the cell supernatant. The highest rhFⅦ expression was (1.27±0.09) mg/L, and the highest procoagulant activity was (380.29±13.80)%. ConclusionThe monoclonal HEK293 cell lines which can express rhFⅦ protein efficiently and stably with excellent procoagulant bioactivity is successfully screened.
2.Influencing factors of work-related musculoskeletal disorders in the three body parts among workers of a power grid enterprise
Leyi XU ; Huilin QIN ; Wayi CHEN ; Mingyu LI ; Yanan WANG ; Cuiju WEN ; Jiabin CHEN
China Occupational Medicine 2026;53(1):43-49
Objective To investigate the prevalence and influencing factors of work-related musculoskeletal disorders (WMSDs) in neck, shoulders and lower back among power grid workers. Methods A total of 371 workers from a power grid enterprise in Guangdong Province were selected as the research subjects using the convenience sampling method. A cross-sectional survey of WMSDs in the neck, shoulders and waist of the workers was conducted using the modified Musculoskeletal Disorders Questionnaire. Results The overall prevalence of WMSDs among the power grid workers was 62.8%, with prevalence of 37.2%, 33.7% and 32.1% for WMSDs in neck, shoulders and lower back, respectively. Binary logistic regression analysis showed that power grid workers who did not maintain a good sitting posture or were unable to maintain good sitting posture over prolonged periods had a higher risk of neck WMSDs than those who maintained a good sitting posture (both P<0.01). A higher frequency of head-down posture during work was associated with an increased risk of neck WMSDs (both P<0.05). Female workers had a higher risk of shoulder WMSDs than male workers (P<0.05). A higher frequency of early awakening with inability to fall back asleep, as well as a higher frequency of head-down posture during work, were both associated with an increased risk of shoulder WMSDs (all P<0.05). Workers with a sedentary habit had a higher risk of shoulder WMSDs than those without (P<0.01). Workers with insufficient rest time had a higher risk of shoulder WMSDs than those with sufficient rest time (P<0.01). Both maintenance workers and managers had a higher risk of lower back WMSDs than workers in other occupational categories (all P<0.05). Workers who experienced nocturnal awakening with difficulty falling back asleep at frequency of several times per year, ≥1 time /month, ≥1 time /week, had higher risk of lower back WMSDs than those who never experienced such problem (all P<0.05). Workers with a sedentary habit and those uncertain about having a sedentary habit both had a higher risk of lower back WMSDs than those without (both P<0.05). Greater forward neck flexion during work was associated with an increased risk of lower back WMSDs (both P<0.05). Workers who occasionally tilted their necks to the side while working had a higher risk of lower back WMSDs than those who did not (P<0.05). Conclusion WMSDs are highly prevalent among power grid workers, particularly affecting the neck, shoulder, and waist. Influencing factors include individual characteristics, behavioral habits, work organization, work posture, and workload. Maintaining proper posture and adequate rest may reduce the risk of WMSDs.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
6.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
7.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
8.Analyzing the occupational health literacy level and its influencing factors among workers in non-metallic mineral product industry in Yunfu City
Xiaoyue CHEN ; Xiaotang SU ; Jiabin CHEN ; Min YANG ; Huiqing CHEN ; Xiaoyi LI ; Jichao CHEN
China Occupational Medicine 2025;52(1):94-98
Objective To analyze the occupational health literacy (OHL) level and its influencing factors of workers in non-metallic mineral product industry in Yunfu City. Methods A total of 947 frontline workers from 24 non-metallic mineral products enterprises in Yunfu City were selected as the research subjects using the stratified random sampling method. The OHL level of the workers were assessed using the Occupational Health Literacy Questionnaire of National Key Populations. Results The overall OHL level of the research subjects was 58.3% (552/947). The OHL levels across four dimensions, from highest to lowest, were basic knowledge of occupational health protection (94.7%), healthy work practices and behaviors (81.8%), legal knowledge of occupational health (65.5%), and basic skills of occupational health protection (25.9%). The results of binary logistic regression analysis showed that workers with 2.0-<10.0 years and ≥10 years of work experience had higher OHL levels than those with <2.0 years of work experience (all P<0.01). Workers with a high school education or above had higher OHL levels than those with a junior high school education or below (all P<0.01). Workers in large- and medium-sized enterprises had higher OHL levels than those in small and micro-sized enterprises (both P<0.01). Conclusion The OHL levels of workers in Yunfu City's non-metallic mineral products industry can be further improved, particularly the occupational health protection skills and related legal knowledge. Workers with short seniority, low educational level, and in small and micro enterprises should be the key groups for improving OHL levels.
9.Analysis of a case of regulatory violations by an occupational health examination institution
Chanchan QI ; Ruiyan HUANG ; Chaoting ZHAO ; Leyi XU ; Jianyong LU ; Xiaoyi LI ; Jiabin CHEN
China Occupational Medicine 2025;52(1):106-109
Objective To analyze a case of violations by an occupational medical examination (OME) institution and to explore the key control points for the supervision and management of OME institutions, as well as the core role of quality assessment in this context. Methods An OME institution suspected of illegal activities was used as the study subject. Retrospective analysis was conducted. Clues of suspected violations were identified by an on-site quality assessment. After investigation and verification by the local health authorities, legal action was taken against the institution for its violations. Results During an on-site quality assessment, the Guangdong Province OME quality control expert group discovered that the OME institution violated regulations, including unqualified personnel file, exceeding the scope of services category, issuing false reports, failing to report suspected occupational diseases on time, and failing to notify workers about suspected occupational diseases as required. The evidence was then submitted to the Guangdong Province OME Quality Control Center, which subsequently forwarded the case to local health administration department for filing and investigation. After the investigation, penalties were imposed on the OME institution for its illegal activities. Conclusion The key supervision and inspection points in the quality assessment of OME institutions include personnel file configuration, the quality control management system and its implementation, the quality of OME reports, and information reporting. Quality assessment plays a pivotal role in ensuring the legal and compliant practice of OME institutions, safeguarding the health rights and interests of workers, and enhancing the overall standard of the OME industry.
10.Efficacy of Ureteral Dilation Versus Ureteral Reimplantation for Primary Obstructed Megaureter in Children
Jiabin JIANG ; Yin ZHANG ; Ye ZHANG ; Xiang FANG ; Daolong LI ; Peng TANG ; Tengyun LONG ; Min CHAO
Journal of Sun Yat-sen University(Medical Sciences) 2025;46(4):686-692
[Objective]To evaluate the efficacy of ureteral dilation versus ureteral reimplantation in treating pediatric primary obstructive megaureter(POM).[Methods]A retrospective analysis was conducted on clinical data of 53 pediatric patients with POM treated in the Department of Urology,Anhui Provincial Children's Hospital from April 2019 to September 2023.The cohort included 37 boys and 16 girls with 5 bilateral and 48 unilateral cases.The age ranged from 1 to 157 months,with a median age of 17.00(5.50-48.00)months.Patients were assigned to 3 groups based on the management of the ureteral stricture segment:dilation group(18 cases,19 sides),Cohen group(20 cases,24 sides),and Lich-Gregoir group(15 cases,15 sides).The duration of the operations,postoperative hospital stays,postoperative indwelling catheters,postoperative D-J stents;changes in renal pelvis anteroposterior diameter and ureteral diameter;and postoperative complications were compared to evaluate the therapeutic effects.[Results]All 53 patients successfully underwent surgery.The dilation group showed significantly shorter operative time,postoperative hospital stay,and postoperative catheterization duration compared to the Cohen and Lich-Gregoir groups(P<0.05).However,the postoperative D-J stent time was longer in the dilation group than in the other 2 groups(P<0.05).Upon follow-ups for 6-12 months after stent removal,all groups demonstrated statistically significant reductions in renal pelvis anteroposterior diameter and ureteral diameter compared to preoperative values(P<0.05).No significant differences were observed among the 3 groups in hydronephrosis resolution rates(P>0.05).Additionally,the incidence of postoperative complications(urinary tract infection,vesicoureteral reflux,and reoperation for restenosis)did not differ significantly among the groups(P>0.05).[Conclusions]Ureteral dilation demonstrated non-inferior short-term clinical efficacy compared to ureteral reimplantation in managing POM in pediatric patients.With reduced operative time,minimal invasiveness,and technical simplicity,ureteral dilation may be considered a preferential treatment option for children with POM.

Result Analysis
Print
Save
E-mail