1.Construction and characterization of recombinant human coagulation factor Ⅶ stable transfected cell lines
Xiaoxiao LI ; Jiabin CHEN ; Jiajun LIU ; Zhifei ZHANG ; Sen ZOU ; Lihua ZHU ; Zhaoyong YANG
Acta Universitatis Medicinalis Anhui 2026;61(1):16-22
ObjectiveTo construct a stable monoclonal human embryonic kidney 293 (HEK293) cell line expressing recombinant human coagulation factor Ⅶ (rhFⅦ) and evaluate the expression level and procoagulant bioactivity of rhFⅦ. MethodsThe plasmid pCDNA3.1-EGFP-FⅦ was transfected into HEK293 cells to verify the effectiveness of the transfection system. The plasmid pCDNA3.1-FⅦ was transfected into HEK293 cells, and monoclonal stable transfected cell lines were selected using geneticin (G418). The transcription of the FⅦ gene was identified by reverse transcription polymerase chain reaction (RT-PCR). The expression level of rhFⅦ in the supernatant of the monoclonal stable transfected cell line was detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot. The concentration of rhFⅦ was determined by enzyme-linked immunosorbent assay (ELISA), and the procoagulant activity of rhFⅦ was measured by human coagulation factor Ⅶ potency assay. ResultsHEK293 cells transfected with pcDNA3.1-EGFP-FⅦ showed green fluorescence, indicating that rhFⅦ was successfully expressed in the supernatant of HEK293 cells after transient transfection with pcDNA3.1-FⅦ. The monoclonal stable transfected cell line was obtained by G418 screening. RT-PCR identified that the FⅦ gene was integrated into the genome of the monoclonal stable transfected cell line. The cell viability was good as detected by Cell Counting Kit-8, and a single band of rhFⅦ was obtained by purification of the cell supernatant. The highest rhFⅦ expression was (1.27±0.09) mg/L, and the highest procoagulant activity was (380.29±13.80)%. ConclusionThe monoclonal HEK293 cell lines which can express rhFⅦ protein efficiently and stably with excellent procoagulant bioactivity is successfully screened.
2.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Analyzing occupational hazard factors monitoring in key industry workplaces in a city from 2019 to 2023
Liecong HU ; Zheng MA ; Quanjin ZHONG ; Manlian CHEN ; Peishan CHEN ; Jiabin CHEN ; Shibiao SU ; Jinguang XIONG
China Occupational Medicine 2025;52(1):89-93
Objective To analyze the monitoring status of occupational hazard factors in key industry workplaces in a city of the Pearl River Delta area from 2019 to 2023. Methods A total of 1 548 enterprises in 12 key industries of the city were selected as the research subjects using the judgmental sampling method. Their monitoring data for dust, chemical factors, and noise, along with the occupational health management status of the enterprises were analyzed. Results Among the 1 548 enterprises, large and medium-sized enterprises accounted for 2.7% and 13.4%, while small and micro enterprises accounted for 83.9%. A total of 474 enterprises exceeded the national limit in the detection of occupational hazard factors, with an exceedance rate of 30.6%. The rates of workers exposed to occupational hazard factors, dust, chemical factors, and noise were 29.4%, 6.9%, 21.0%, and 13.0%, respectively, all showing a downward trend year by year (all P<0.05). The training rates for occupational health among enterprise managers, responsible persons, and workers were 84.1%, 84.2%, and 91.2%, respectively. The detection rates for abnormal occupational health examinations among workers exposed to dust, chemical factors, and noise were 0.2%, 0.3%, and 0.5%, respectively. The setting rates of warning signs and warning instructions among enterprises for dust, chemical toxins, and noise were 87.3%, 91.1%, and 89.5%, respectively. The setting rates for dust, toxic chemical, and noise control facilities were 72.4%, 75.4%, and 46.0%, with effectiveness rates of 70.5%, 56.6%, and 55.2%, respectively. The distribution rates of personal protective dust masks, gas masks, and noise earplugs/earmuffs were 91.9%, 83.8%, and 86.4%, with wearing rates of 80.8%, 70.5%, and 76.4%, respectively. The detection rates of exceeding national limits for dust, chemical factors, and noise in the work site of occupational hazard factors were15.2%, 1.0%, and 21.6%, respectively. The detection rates of exceeding national limits for dust, chemical factors, and noise in the workplace of occupational hazard factors were 2.4%, 2.5%, and 12.3%, respectively. The exceedance rate for noise in work site showed an upward trend year by year (P<0.01). Conclusion Occupational disease prevention and control work in the key industries of this city needs strengthening. It is essential to further enhance the regular monitoring and preventive measures of occupational hazard factors in enterprises, improve protective measures, strengthen the use of personal protective equipment, and enhance occupational health training and supervision, to effectively reduce the risk of occupational diseases and protect workers' occupational health rights.
5.Analyzing the occupational health literacy level and its influencing factors among workers in non-metallic mineral product industry in Yunfu City
Xiaoyue CHEN ; Xiaotang SU ; Jiabin CHEN ; Min YANG ; Huiqing CHEN ; Xiaoyi LI ; Jichao CHEN
China Occupational Medicine 2025;52(1):94-98
Objective To analyze the occupational health literacy (OHL) level and its influencing factors of workers in non-metallic mineral product industry in Yunfu City. Methods A total of 947 frontline workers from 24 non-metallic mineral products enterprises in Yunfu City were selected as the research subjects using the stratified random sampling method. The OHL level of the workers were assessed using the Occupational Health Literacy Questionnaire of National Key Populations. Results The overall OHL level of the research subjects was 58.3% (552/947). The OHL levels across four dimensions, from highest to lowest, were basic knowledge of occupational health protection (94.7%), healthy work practices and behaviors (81.8%), legal knowledge of occupational health (65.5%), and basic skills of occupational health protection (25.9%). The results of binary logistic regression analysis showed that workers with 2.0-<10.0 years and ≥10 years of work experience had higher OHL levels than those with <2.0 years of work experience (all P<0.01). Workers with a high school education or above had higher OHL levels than those with a junior high school education or below (all P<0.01). Workers in large- and medium-sized enterprises had higher OHL levels than those in small and micro-sized enterprises (both P<0.01). Conclusion The OHL levels of workers in Yunfu City's non-metallic mineral products industry can be further improved, particularly the occupational health protection skills and related legal knowledge. Workers with short seniority, low educational level, and in small and micro enterprises should be the key groups for improving OHL levels.
6.Analysis of a case of regulatory violations by an occupational health examination institution
Chanchan QI ; Ruiyan HUANG ; Chaoting ZHAO ; Leyi XU ; Jianyong LU ; Xiaoyi LI ; Jiabin CHEN
China Occupational Medicine 2025;52(1):106-109
Objective To analyze a case of violations by an occupational medical examination (OME) institution and to explore the key control points for the supervision and management of OME institutions, as well as the core role of quality assessment in this context. Methods An OME institution suspected of illegal activities was used as the study subject. Retrospective analysis was conducted. Clues of suspected violations were identified by an on-site quality assessment. After investigation and verification by the local health authorities, legal action was taken against the institution for its violations. Results During an on-site quality assessment, the Guangdong Province OME quality control expert group discovered that the OME institution violated regulations, including unqualified personnel file, exceeding the scope of services category, issuing false reports, failing to report suspected occupational diseases on time, and failing to notify workers about suspected occupational diseases as required. The evidence was then submitted to the Guangdong Province OME Quality Control Center, which subsequently forwarded the case to local health administration department for filing and investigation. After the investigation, penalties were imposed on the OME institution for its illegal activities. Conclusion The key supervision and inspection points in the quality assessment of OME institutions include personnel file configuration, the quality control management system and its implementation, the quality of OME reports, and information reporting. Quality assessment plays a pivotal role in ensuring the legal and compliant practice of OME institutions, safeguarding the health rights and interests of workers, and enhancing the overall standard of the OME industry.
7.Life's Essential 8 metrics and prognosis in patients with renal insufficiency: Results from the National Health and Nutrition Examination Survey, 2007-2018.
Weihua CHEN ; Guitao XIAO ; Shan DING ; Shanshan SHI ; Yuxiong PAN ; Jiabin TU ; Yanbin ZHANG ; Ying LIAO ; Liling CHEN ; Kaihong CHEN ; Rongchong HUANG
Chinese Medical Journal 2025;138(21):2824-2831
BACKGROUND:
The benefits of ideal cardiovascular-health metrics (ICVHMs) in patients with renal insufficiency remain unclear. This study aimed to investigate the associations between ICVHM and prognosis in a renal insufficiency population.
METHODS:
The trial enrolled 29,682 participants from the US National Health and Nutrition Examination Survey (NHANES), 2007-2018, with mortality follow-up through December 31, 2019. Participants were divided into three groups based on estimated glomerular filtration rates. Cardiovascular health was assessed using new "Life's Essential 8" metrics. Cox regression analyses based on NHANES data were used to determine the associations between ICVHMs and cardiovascular mortality in patients with renal insufficiency.
RESULTS:
During a mean follow-up of 6.58 years, ideal cardiovascular health (hazard ratio [HR] = 0.42; 95% confidence interval [CI]; 0.25-0.70) and ideal health behavior (HR = 0.53; 95% CI; 0.39-0.73) reduced cardiovascular mortality in participants with renal insufficiency. For each one ICVHM increment, a 25% reduction in cardiovascular mortality was recorded (95% CI; 0.69-0.82). When compared with participants with normal renal function, for those with mild renal insufficiency, the HR for cardiovascular mortality gradually decreased from 1.47 (95% CI; 0.85-2.52) in those who had ≤1 ICVHMs to 0.30 (95% CI; 0.12-0.77) in participants who had >6 ICVHMs.
CONCLUSIONS
From an ICVHM perspective, enhanced cardiovascular benefits were observed in individuals with renal insufficiency, coupled with a reduced risk of all-cause mortality. Furthermore, when compared with individuals with normal renal function, increased ICVHMs can mitigate adverse risks associated with renal impairment.
Humans
;
Male
;
Female
;
Nutrition Surveys
;
Middle Aged
;
Renal Insufficiency/physiopathology*
;
Aged
;
Prognosis
;
Adult
;
Cardiovascular Diseases/mortality*
;
Glomerular Filtration Rate/physiology*
;
Proportional Hazards Models
8.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
9.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
10.Effect of platelet-rich fibrin combined with sulfadiazine silver dressing on healing time and curative effect of chronic refractory wounds
Jiabin HUANG ; Chengning LI ; Yunteng YOU ; Minxi CHEN ; Jiurao LIN
Journal of Navy Medicine 2025;46(2):174-178
Objective To explore the effect of platelet-rich fibrin(PRF)combined with sulfadiazine silver dressing on healing time and curative effect of chronic refractory wounds.Methods A total of 126 patients with chronic refractory wounds who were treated in Ningde City Hospital from December 1,2022 to December 1,2023 were selected as research objects.They were randomly divided into control group and experimental group according to odd-even number,with 63 cases in each group.The control group was treated with sulfadiazine silver dressing,and the experimental group was treated with PRF and sulfadiazine silver dressing.The curative effect,wound recovery,serum inflammatory cytokine levels and complications were compared between the two groups.Results The total effective rate of the experimental group was significantly higher than that of the control group([96.83%,61/63]vs[77.78%,49/63],χ2=10.309,P<0.05).The frequency of dressing changes and wound healing time in the experimental group were significantly less than those in the control group([4.44±1.53]times vs[9.16±2.23]times,[15.35±2.29]d vs[20.25±3.24]d,P<0.05).The reduction of wound area in the experimental group was significantly higher than that in the control group([14.95±2.80]cm2 vs[11.21±2.35]cm2,P<0.05).There was no significant difference in serum inflammatory cytokine levels between the two groups before treatment(t=0.209,0.295,0.088,P>0.05).After 14 of treatment,the levels of CRP,PCT,and IL-6 were decreased in both groups,and the levels of CRP,PCT,and IL-6 in the experimental group were significantly lower than those in the control group([1.14±0.86]mg/L vs[2.11±0.75]mg/L,[4.07±0.56]μg/L vs[4.96±0.71]μg/L,[61.54±25.33]ng/L vs[84.48±24.76]ng/L,t=6.748,7.809,5.140,P<0.05).The total incidence of complications in the experimental group was significantly lower than that in the control group(9.52%vs 25.40%,χ2=5.507,P<0.05).Conclusion PRF combined with sulfadiazine silver dressing can increase curative effects,accelerate wound healing,improve serum inflammatory markers,and reduce complications in patients with chronic refractory wounds.

Result Analysis
Print
Save
E-mail