1.Construction and characterization of recombinant human coagulation factor Ⅶ stable transfected cell lines
Xiaoxiao LI ; Jiabin CHEN ; Jiajun LIU ; Zhifei ZHANG ; Sen ZOU ; Lihua ZHU ; Zhaoyong YANG
Acta Universitatis Medicinalis Anhui 2026;61(1):16-22
ObjectiveTo construct a stable monoclonal human embryonic kidney 293 (HEK293) cell line expressing recombinant human coagulation factor Ⅶ (rhFⅦ) and evaluate the expression level and procoagulant bioactivity of rhFⅦ. MethodsThe plasmid pCDNA3.1-EGFP-FⅦ was transfected into HEK293 cells to verify the effectiveness of the transfection system. The plasmid pCDNA3.1-FⅦ was transfected into HEK293 cells, and monoclonal stable transfected cell lines were selected using geneticin (G418). The transcription of the FⅦ gene was identified by reverse transcription polymerase chain reaction (RT-PCR). The expression level of rhFⅦ in the supernatant of the monoclonal stable transfected cell line was detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot. The concentration of rhFⅦ was determined by enzyme-linked immunosorbent assay (ELISA), and the procoagulant activity of rhFⅦ was measured by human coagulation factor Ⅶ potency assay. ResultsHEK293 cells transfected with pcDNA3.1-EGFP-FⅦ showed green fluorescence, indicating that rhFⅦ was successfully expressed in the supernatant of HEK293 cells after transient transfection with pcDNA3.1-FⅦ. The monoclonal stable transfected cell line was obtained by G418 screening. RT-PCR identified that the FⅦ gene was integrated into the genome of the monoclonal stable transfected cell line. The cell viability was good as detected by Cell Counting Kit-8, and a single band of rhFⅦ was obtained by purification of the cell supernatant. The highest rhFⅦ expression was (1.27±0.09) mg/L, and the highest procoagulant activity was (380.29±13.80)%. ConclusionThe monoclonal HEK293 cell lines which can express rhFⅦ protein efficiently and stably with excellent procoagulant bioactivity is successfully screened.
2.Expression of PKMYT1 in glioma and its association with prognosis,drug sensitivity,and immune infiltration
Huiping XIE ; Jiajun LIU ; Jiabin CHEN ; Lihua ZHU ; Zhifei ZHANG ; Zhaoyong YANG
Chinese Journal of Cancer Biotherapy 2025;32(5):498-509
Objective:To analyze by bioinformatics the association between the expression of membrane-associated tyrosine/threonine protein kinase 1(PKMYT1)in glioma with its prognostic value,biological function,drug sensitivity,gene mutation,and immune infiltration.Methods:The differential expression of PKMYT1 was analyzed based on the Chinese Glioma Genome Atlas database(CGGA)and the Cancer Genome Atlas database(TCGA).Pathways likely to be enriched for PKMYT1 were predicted by gene ontology analysis(GO)and gene set enrichment analysis(GSEA).PKMYT1 was subjected to Pearson correlation and gene set variation analysis(GSVA)with cell cycle-related genes and gene sets.The survival prognosis,gene mutation,drug sensitivity and immune infiltration were further analyzed for PKMYT1 high and low expression groups of glioma patients.Results:PKMYT1 was significantly highly expressed in WHO high-grade glioma(P<0.000 1),IDH wild-type glioma(P<0.05),and glioblastoma(P<0.000 1).Overall survival(OS)of patients in the PKMYT1 low expression group was significantly higher than that of the high expression group(P<0.05).Cox regression analysis showed that PKMYT1 expression level was an independent prognostic factor for OS(P<0.05).GO and GSEA analyses showed that the gene sets co-expressed with PKMYT1 were mainly enriched in signaling pathways such as cell cycle,DNA replication and DNA damage repair.Pearson correlation and GSVA analyses showed that the expression of PKMYT1 was significantly and positively correlated with the cell cycle-related genes,gene sets and cell cycle checkpoint genes(P<0.01).Drug sensitivity analysis revealed that patients in the PKMYT1 high expression group had high sensitivity osimertinib,dabrafenib,carmustine and cediranib(P<0.05).Mutation analysis revealed that the IDH1 gene had a higher mutation frequency in the PKMYT1 low expression group.The results of immune infiltration analysis showed that PKMYT1 expression was significantly positively correlated with glioma stroma score(r=0.13,P<0.001),immune score(r=0.11,P<0.01)and ESTIMATE score(r=0.13,P<0.001);and was significantly positively correlated with immune cell infiltration level of regulatory T(Treg)cells and M2-type macrophages(P<0.05).Conclusion:Patients with high PKMYT1 expression have a poorer prognosis,and the mechanism may be related to tumor immune infiltration and cell cycle regulation.PKMYT1 is expected to be a potential target for the diagnosis and treatment of glioma.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
6.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
7.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
8.Analyzing occupational hazard factors monitoring in key industry workplaces in a city from 2019 to 2023
Liecong HU ; Zheng MA ; Quanjin ZHONG ; Manlian CHEN ; Peishan CHEN ; Jiabin CHEN ; Shibiao SU ; Jinguang XIONG
China Occupational Medicine 2025;52(1):89-93
Objective To analyze the monitoring status of occupational hazard factors in key industry workplaces in a city of the Pearl River Delta area from 2019 to 2023. Methods A total of 1 548 enterprises in 12 key industries of the city were selected as the research subjects using the judgmental sampling method. Their monitoring data for dust, chemical factors, and noise, along with the occupational health management status of the enterprises were analyzed. Results Among the 1 548 enterprises, large and medium-sized enterprises accounted for 2.7% and 13.4%, while small and micro enterprises accounted for 83.9%. A total of 474 enterprises exceeded the national limit in the detection of occupational hazard factors, with an exceedance rate of 30.6%. The rates of workers exposed to occupational hazard factors, dust, chemical factors, and noise were 29.4%, 6.9%, 21.0%, and 13.0%, respectively, all showing a downward trend year by year (all P<0.05). The training rates for occupational health among enterprise managers, responsible persons, and workers were 84.1%, 84.2%, and 91.2%, respectively. The detection rates for abnormal occupational health examinations among workers exposed to dust, chemical factors, and noise were 0.2%, 0.3%, and 0.5%, respectively. The setting rates of warning signs and warning instructions among enterprises for dust, chemical toxins, and noise were 87.3%, 91.1%, and 89.5%, respectively. The setting rates for dust, toxic chemical, and noise control facilities were 72.4%, 75.4%, and 46.0%, with effectiveness rates of 70.5%, 56.6%, and 55.2%, respectively. The distribution rates of personal protective dust masks, gas masks, and noise earplugs/earmuffs were 91.9%, 83.8%, and 86.4%, with wearing rates of 80.8%, 70.5%, and 76.4%, respectively. The detection rates of exceeding national limits for dust, chemical factors, and noise in the work site of occupational hazard factors were15.2%, 1.0%, and 21.6%, respectively. The detection rates of exceeding national limits for dust, chemical factors, and noise in the workplace of occupational hazard factors were 2.4%, 2.5%, and 12.3%, respectively. The exceedance rate for noise in work site showed an upward trend year by year (P<0.01). Conclusion Occupational disease prevention and control work in the key industries of this city needs strengthening. It is essential to further enhance the regular monitoring and preventive measures of occupational hazard factors in enterprises, improve protective measures, strengthen the use of personal protective equipment, and enhance occupational health training and supervision, to effectively reduce the risk of occupational diseases and protect workers' occupational health rights.
9.Analyzing the occupational health literacy level and its influencing factors among workers in non-metallic mineral product industry in Yunfu City
Xiaoyue CHEN ; Xiaotang SU ; Jiabin CHEN ; Min YANG ; Huiqing CHEN ; Xiaoyi LI ; Jichao CHEN
China Occupational Medicine 2025;52(1):94-98
Objective To analyze the occupational health literacy (OHL) level and its influencing factors of workers in non-metallic mineral product industry in Yunfu City. Methods A total of 947 frontline workers from 24 non-metallic mineral products enterprises in Yunfu City were selected as the research subjects using the stratified random sampling method. The OHL level of the workers were assessed using the Occupational Health Literacy Questionnaire of National Key Populations. Results The overall OHL level of the research subjects was 58.3% (552/947). The OHL levels across four dimensions, from highest to lowest, were basic knowledge of occupational health protection (94.7%), healthy work practices and behaviors (81.8%), legal knowledge of occupational health (65.5%), and basic skills of occupational health protection (25.9%). The results of binary logistic regression analysis showed that workers with 2.0-<10.0 years and ≥10 years of work experience had higher OHL levels than those with <2.0 years of work experience (all P<0.01). Workers with a high school education or above had higher OHL levels than those with a junior high school education or below (all P<0.01). Workers in large- and medium-sized enterprises had higher OHL levels than those in small and micro-sized enterprises (both P<0.01). Conclusion The OHL levels of workers in Yunfu City's non-metallic mineral products industry can be further improved, particularly the occupational health protection skills and related legal knowledge. Workers with short seniority, low educational level, and in small and micro enterprises should be the key groups for improving OHL levels.
10.Analysis of a case of regulatory violations by an occupational health examination institution
Chanchan QI ; Ruiyan HUANG ; Chaoting ZHAO ; Leyi XU ; Jianyong LU ; Xiaoyi LI ; Jiabin CHEN
China Occupational Medicine 2025;52(1):106-109
Objective To analyze a case of violations by an occupational medical examination (OME) institution and to explore the key control points for the supervision and management of OME institutions, as well as the core role of quality assessment in this context. Methods An OME institution suspected of illegal activities was used as the study subject. Retrospective analysis was conducted. Clues of suspected violations were identified by an on-site quality assessment. After investigation and verification by the local health authorities, legal action was taken against the institution for its violations. Results During an on-site quality assessment, the Guangdong Province OME quality control expert group discovered that the OME institution violated regulations, including unqualified personnel file, exceeding the scope of services category, issuing false reports, failing to report suspected occupational diseases on time, and failing to notify workers about suspected occupational diseases as required. The evidence was then submitted to the Guangdong Province OME Quality Control Center, which subsequently forwarded the case to local health administration department for filing and investigation. After the investigation, penalties were imposed on the OME institution for its illegal activities. Conclusion The key supervision and inspection points in the quality assessment of OME institutions include personnel file configuration, the quality control management system and its implementation, the quality of OME reports, and information reporting. Quality assessment plays a pivotal role in ensuring the legal and compliant practice of OME institutions, safeguarding the health rights and interests of workers, and enhancing the overall standard of the OME industry.

Result Analysis
Print
Save
E-mail