1.Technique and Application of Deep Learning-based EEG Denoising
Bao-Lian SHAN ; Hai-Qing YU ; Yong-Zhi HUANG ; Jia-Yuan MENG ; Min-Peng XU ; Tzyy-Ping JUNG ; Dong MING
Progress in Biochemistry and Biophysics 2026;53(8):2147-2160
Electroencephalography (EEG) is a non-invasive neurophysiological monitoring technique. It records the electrical activity of the cerebral cortex using electrodes placed on the scalp surface. Owing to its high safety, portability, and millisecond-level temporal resolution, EEG has been widely utilized in a variety of fields, including clinical diagnosis, brain-computer interfaces (BCIs), and cognitive neuroscience research. However, due to its microvolt-level amplitude, EEG is highly susceptible to various artifacts, including electrooculographic (EOG), electrocardiographic (ECG), electromyographic (EMG), and power line interference (PLI). These artifacts can obscure genuine neural activity and introduce spurious electrophysiological features. Consequently, they may compromise EEG signal quality, thereby reducing the reliability of downstream analyses. To address this issue, numerous EEG artifact removal methods have been developed, including both traditional denoising techniques and deep learning-based approaches. Traditional EEG denoising methods have long served as the primary solutions for artifact removal. Representative approaches include filtering, regression, and blind source separation. Although these methods have demonstrated effectiveness in specific scenarios, they suffer from several inherent limitations. Filtering assumes that artifacts and EEG signals can be separated in the frequency domain, but many artifacts, such as EOG and EMG, overlap with EEG spectra, which may lead to the loss of valuable neural information. Regression methods require high-quality artifact references to estimate and subtract contaminations, limiting their effectiveness in reference-free scenarios. Blind source separation can remove artifacts without external references, but it typically requires the number of EEG channels to exceed the number of sources, restricting its application in single- or low-channel EEG recordings. Deep learning-based EEG denoising methods address these limitations effectively. First, they learn the nonlinear mapping between contaminated and clean EEG directly from data in an end-to-end manner. This approach does not rely on assumptions about spectral separability, thereby preserving neural activity more completely. Second, the reference information is incorporated during the training phase, allowing the trained model to perform artifact removal independently without external references. Third, deep learning models can be flexibly designed to accommodate various recording setups, achieving robust denoising for both high-density and single-channel EEG. Collectively, these advantages enable deep learning-based methods to overcome the main challenges of traditional approaches, providing more accurate and reliable EEG signal recovery. The superior denoising performance of deep learning-based EEG denoising methods has attracted increasing attention in EEG artifact removal research. As a result, many deep learning-based denoising methods have been developed and successfully applied in neural engineering areas. However, a systematic review of the techniques and applications in this field is still lacking. To address this gap, this paper reviews recent advances in deep learning-based EEG denoising from four perspectives: technical principle, benchmark dataset, denoising model, and evaluation method. Representative applications in neural signal analysis and BCI decoding are also summarized. Furthermore, the advantage, existing challenge, and future research direction of deep learning-based EEG denoising are discussed. This review aims to provide valuable theoretical insights and technical guidance for researchers. It is also expected to promote further advances and broader applications of deep learning-based EEG denoising techniques.
2.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
3.miR-142a-3p Reduces Autophagy in TCMK-1 Cells and Enhances Pyroptosis by Targeting ATG16L1
Xing ZHAO ; Fei YU ; Rui-Yang YUAN ; Ya-Ru YANG ; Jia-Yan LIU ; Hai-Mai DING ; Xue-Ming ZHANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(7):1031-1039
The incidence rate of kidney diseases in China has always remained high.At present,the clinical treat-ment mainly focuses on symptomatic treatment to delay the progression of the disease,and there is a lack of eco-nomical and effective treatment methods.MicroRNA plays an important regulatory role in the occurrence and devel-opment of diseases.This study aims to explore the role and regulatory mechanism of miR-142a-3p in adriamycin(ADR)-induced renal tubular epithelial cell(TCMK-1)injury,with a focus on its potential as a therapeutic target for ADR nephropathy.First,cell viability was assessed using the CCK-8 kit,and a mouse renal tubular epithelial cell model induced by ADR was established.Subsequently,alterations in miR-142a-3p and its target gene ATG16L1 mRNA levels were quantified using RT-qPCR.Western blotting was used to detect the protein levels of autophagy marker proteins and pyroptosis marker proteins.Monodansylcadaverin(MDC)staining was performed and the autophagy of cells was detected by flow cytometry.The results showed that the relative expression of miR-142a-3p in TCMK-1 cells induced by ADR was increased and the relative expression of its target gene ATG16L1 was decreased(P<0.0001).Western blotting results showed that the levels of p62(P<0.001)and pyroptosis-related proteins(P<0.001)were increased,while the protein levels of autophagy-related proteins were decreased(P<0.05).The flow cytometry results showed that there was no difference in the mean fluorescence intensity of autoph-agosomes between the ADR group and the autophagosome inhibitor group(3-MA group)(P>0.05),indicating that after ADR induction,cell autophagy was inhibited and pyroptosis was enhanced.When the expression of miR-142a-3p was inhibited by transfecting miR-142a-3p inhibitor,the relative expression level of the target gene ATG16L1 was restored(P<0.001).Western blotting showed that the protein level of p62(P<0.01)and pyropto-sis-related proteins(P<0.01)were decreased,and the protein level of autophagy-related proteins was restored(P<0.001).Flow cytometry results further indicated that cell autophagy was restored(P<0.0001).In conclusion,ADR targets A TG1 6L1 through miR-142a-3p to reduce the autophagy level of TCMK-1,and simultaneously activates GSDMD-mediated pyroptosis.
4.Effect of endometrial thickness on obstetric and neonatal outcomes of monoparous pregnancy in fresh cleavage-embryo transfer
Li-juan SUN ; Jia-ping PAN ; Shan-shan LIANG ; Mei-yuan HUANG ; Kai-li ZHU ; Xiao-ming TENG ; Hai-xia WU
Fudan University Journal of Medical Sciences 2025;52(1):63-70
Objective To investigate the association of endometrial thickness(EMT)with obstetric and neonatal outcomes of monoparous pregnancy in fresh cleavage embryos transfer.Methods A total of 1 845 patients of monoparous pregnancy after fresh cleavage embryos transfer cycles from Jan 2016 to Mar 2022 at Shanghai First Maternity and Infant Hospital,Tongji Universtiy were analyzed retrospectively.Patients were categorized into three groups by EMT on transferation day:≤8 mm(group A),8-14 mm(group B)and≥14 mm(group C).The primary outcomes were preterm birth(PTB),birth weight and birth weight z-score,small-for-gestation age,large-for-gestation age,very low birth weight,low birth weight and macrosomia.The second outcomes were pregnancy and perinatal complications.The relationship between EMT and adverse neonatal outcomes was estimated by Logistic regression analysis.Results The rate of ectopic pregnancy was increased significantly in group A.No significant differences were found among the three groups in gestation age,birth weight,birth weight z-score,PTB,small for gestation age,large for gestation age,low birth weight,very low birth weight and macrosomia.Compared with group B,the odds of adverse neonatal outcomes did not show significant differences before and after adjustment in both group A and group C by Logistic regression analysis.Conclusion Thinner EMT in fresh cleavage embryos transfer is associated with higher rate of ectopic pregnancy,while it is not independently associated with adverse perinatal outcomes.
5.Research progress on effects of orexin and its receptor antagonists on epilepsy
Chen-shuo JIA ; Yuan-yuan LIU ; Jing ZHANG ; Ai-ping ZHENG ; Zeng-ming WANG ; Qiao WANG
Chinese Pharmacological Bulletin 2025;41(10):1823-1830
Epilepsy is a chronic neurological disorder caused by an imbalance between excitation and inhibition in the central nervous system.Recently,the role of the orexin system in the pathogenesis of epilepsy has garnered significant attention.Orex-in primarily regulates arousal states and enhances neuronal excit-ability through activation of OX1-R/OX2-R receptors.Studies have shown that elevated orexin levels lower the seizure thresh-old,while orexin receptor antagonists(ORAs)exhibit potential antiepileptic effects.ORAs suppress epileptiform discharges by reducing glutamate release,enhancing GABAergic inhibitory effects,and modulating the thalamocortical circuit.Animal ex-periments and preliminary clinical studies demonstrate that OX1R antagonists decrease excitatory synaptic transmission,whereas OX2 R antagonists primarily strengthen GABA-mediated inhibition.With the widespread application of ORAs in sleep disorders,exploring their clinical value as antiepileptic drugs will become a key focus for future research.This review summa-rizes the role of the orexin system in epileptogenesis and discus-ses the research progress and future directions of ORAs as poten-tial antiepileptic agents.
6.Incidence rates and high-risk factors of different typies of patient-ventilator asynchrony under assisted mechanical ventilation
Qimin CHEN ; Jiaoyangzi LIU ; Jia YUAN ; Dehua HE ; Ming LIU ; Caixue PAN ; Ying LIU ; Yan TANG ; Xu LIU ; Xianjun CHEN ; Chuan XIAO ; Shuwen LI ; Wei LI ; Daixiu GAO ; Feng SHEN
The Journal of Practical Medicine 2025;41(10):1509-1516
Objective To investigate the incidence and types of patient-ventilator asynchrony(PVA)in mechanically ventilated patients within the intensive care unit(ICU),and to identify associated high-risk factors,thereby providing a basis for reducing PVA,enhancing mechanical ventilation efficiency,and refining ventilation strategies.Methods A prospective observational study was conducted among patients admitted to the general ICU of the Affiliated Hospital of Guizhou Medical University from October to December 2024 who were receiving mechanical ventilation.Inclusion criteria were as follows:age ≥18 years and mechanical ventilation duration ≥12 hours.Exclusion criteria included complete controlled mechanical ventilation,palliative care or do-not-resuscitate status,and lack of informed consent.Senior respiratory therapists performed daily bedside observations of ventilator waveforms for 10~15 minutes between 08:00 and 12:00.PVA was diagnosed based on pressure-time and flow-time waveforms,with the types of PVA being recorded.Demographic and clinical data,including age,sex,body mass index(BMI),primary diagnosis,comorbidities,APACHEⅡ score at ICU admission,blood gas analysis,ventila-tion mode and parameters,analgesia and sedation status,duration of mechanical ventilation,and length of ICU stay,were collected.The incidence and types of PVA during the observation period were analyzed.Univariate and multivariate logistic regression analyses were performed to identify high-risk factors for PVA.Clinical outcomes were compared between patients with and without PVA.Results A total of 105 patients and 453 episodes of assisted mechanical ventilation waveforms were analyzed.Among these,60.95%(64/105)experienced at least one episode of PVA.Of the 453 ventilation waveforms assessed,35.76%(162/453)demonstrated PVA.The types of PVA,ranked by incidence,were as follows:cycling mismatch(12.58%,57/453),double triggering(11.92%,54/453),ineffective triggering(9.49%,43/453),flow starvation(5.30%,24/453),and exhalation flow limitation(1.77%,8/453).The incidence of PVA varied significantly across different ventilation modes:45.7%in volume-assist/control ventilation(V-A/C),38.1%in pressure-assist/control ventilation(P-A/C),42.9%in synchronized intermittent mandatory ventilation(SIMV),and 16.7%in pressure support ventilation(PSV)(P<0.001).Multi-variate logistic regression analysis revealed that the mechanical ventilation mode[reference:PSV;V-A/C:OR=4.687,95%CI:2.140~10.263,P<0.001;P-A/C:OR=2.922,95%CI:1.489~5.734,P=0.002;SIMV:OR=4.682,95%CI:1.758~12.466,P=0.002]and actual respiratory rate(OR=1.07,95%CI:1.016~1.127,P=0.011)were significant high-risk factors for PVA.Patients with PVA had a significantly longer duration of mechanical ventilation[8.21(5.35,13.91)days vs.3.00(1.96,5.71)days,P<0.001]compared to those without PVA.Conclusions PVA is commonly observed in ICU patients receiving assisted invasive mechanical ventilation,with cycling mismatch,double triggering,and ineffective triggering being the most prevalent types.The incidence of PVA tends to be lower when using the PSV mode.Clinically,real-time monitoring of patient-ventilator synchrony via ventilator waveforms,along with the optimization of ventilator modes and parameters,should be employed to minimize the occurrence of PVA and enhance the efficiency of mechanical ventilation.
7.Clinical analysis of autologous hematopoietic stem cell transplantation for diffuse large B-cell lymphoma
Akebaer SAIBIYA ; Gang CHEN ; Jianli XU ; Kaile ZHANG ; Ruixue YANG ; Chunxia HAN ; Jia HOU ; Ming JIANG ; Hailong YUAN
Journal of Leukemia & Lymphoma 2025;34(6):342-348
Objective:To investigate the therapeutic efficacy of autologous hematopoietic stem cell transplantation (auto-HSCT) for treatment of diffuse large B-cell lymphoma (DLBCL) and the factors affecting the prognosis.Methods:A retrospective case series study was conducted. The clinical data of 51 patients with DLBCL who underwent auto-HSCT in the First Affiliated Hospital of Xinjiang Medical University from March 2019 to January 2024 were retrospectively analyzed. Patients were divided into high-risk group (19 cases) and non-high-risk group (low-risk, low-moderate-risk and moderate-high-risk groups, 32 cases) based on different risk stratifications; patients were divided into the germinal center B-cell (GCB) group (29 cases) and non-GCB group (22 cases) based on different cellular origins; patients were divided into BEAM group (39 cases) and BeEAM group (12 cases) based on different conditioning regimens before auto-HSCT; patients were divided into auto-HSCT consolidation therapy group (41 cases) and auto-HSCT after relapsed/refractory group (10 cases) based on different transplantation timings. The Kaplan-Meier method was used for survival analysis and log-rank was used for subgroup comparison.Results:All 51 patients achieved the hematopoietic reconstitution with no transplantation-related death within 100 d. Before auto-HSCT, 39 cases achieved complete remission and 12 cases (23.5%) achieved partial remission. After auto-HSCT, all cases achieved complete remission. Follow-up was until May 31, 2024, and the median follow-up time [ M ( Q1, Q3)] of 51 DLBCL patients was 33 (8, 43) months. After 51 DLBCL patients receiving auto-HSCT, 7 patients relapsed and 6 cases died including 3 cases with relapse-related death and 3 cases with non relapse-related death. The 3-year progression-free survival (PFS) and overall survival (OS) rates were 78.5% (95% CI: 64.4%-92.6%) and 85.5% (95% CI: 73.2%-97.8%), respectively. The 3-year PFS rate was 94.7% (95% CI: 84.7%-104.7%) in the high-risk group, 82.2% (95% CI: 67.9%-96.5%) in the non-high-risk group, and the difference in the PFS was not statistically significant between the high-risk group and the non-high-risk group ( P = 0.158). The 3-year PFS rate was 80.1% (95% CI: 64.4%-95.8%) in the GCB group, 88.1% (95% CI: 72.3%-104.2%) in the non-GCB group, and the difference in PFS was not statistically significant between the 2 groups ( P = 0.803). The 3-year PFS rate was 84.9% (95% CI: 72.6%-97.2%) in BEAM group, 61.1% (95% CI: 25.0%-97.2%) in the BeEAM group, and the difference in PFS was not statistically significant between the 2 groups ( P = 0.106). The 3-year PFS rate was 85.4% (95% CI: 73.4%-97.4%) in the auto-HSCT consolidation therapy group, 64.3% (95% CI: 31.4%-96.4%) in the auto-HSCT after relapsed/refractory group, and the difference in PFS was not statistically significant between the 2 groups ( P = 0.171). Conclusions:auto-HSCT is an effective therapy method for DLBCL.
8.Multicolor Fluorescent Copper Nanoclusters/Starch Composites and Their Application in Fingermark Development
Chuan-Jun YUAN ; Ming LI ; Yi-Fei SUN ; Jia-Ming LYU ; Zhi-Bo GAO ; Shi-Qiang SUN ; Pei-Liang HAN ; Feng-He LIU
Chinese Journal of Analytical Chemistry 2025;53(1):55-64,中插1-中插3
On the basis of that the fluorescence wavelength of copper nanoclusters(CuNCs)could cover the entire visible region,multicolor fluorescent CuNCs/starch composites were prepared and applied in fingermark development.With L-glutathione as the reducing agent and protective ligand,blue emissive and orange emissive CuNCs solutions were obtained in alkaline solutions at 90℃and 25℃,respectively.With the aggregation-induced emission effect induced by ethanol as a poor solvent,the fluorescence of orange emissive CuNCs with a higher intensity was achieved in an ethanol-water solution.With ascorbic acid as the reducing agent and 3-mercaptopropionic acid as the protective agent,green emissive CuNCs solution was prepared in an acid solution.Particle morphologies,chemical compositions and optical properties of these three CuNCs above were investigated using physical characterization and spectroscopic analysis,indicating that well-dispersed CuNCs had excellent photoluminescent properties.These CuNCs solutions were combined with starch to form composite powders by simply drying.The influences of the type of CuNCs and the ratio of CuNCs to starch on the emission wavelength and fluorescence intensity of the products were studied.The obtained CuNCs/starch composites could emit blue,green and orange fluorescence under 365 nm ultraviolet light,respectively,which were suitable for fingermark development.Minutiae and partial level-3 features of latent fingermarks could be effectively developed.High-quality fluorescence fingermark images would be captured using appropriate optical filters to eliminate background interference of various substrates.
9.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
10.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.