1.Comparison of Efficacy and Mechanism in Warming Yang and Dispersing Cold of Aconiti Radix Lateralis Praeparata Processed by ZHANG Zhongjing's Method and Pharmacopoeia Method
Mingjie JIAO ; Qian CHEN ; Shuyu YAN ; Yiyan SONG ; Jia ZHANG ; Fei LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):207-217
ObjectiveTo investigate the therapeutic effects and mechanism of decoctions from four kinds of processed products of Aconiti Radix Lateralis Praeparata(ARLP) in deficiency-cold syndrome. MethodsA total of 36 SD rats were randomly divided into the control group, model group, Shengfupian(SFP) group, Paofuzi(PFZ) group, Heishunpian(HSP) group and Paofupian(PFP) group with 6 rats in each group. Except for the control group, rats in other groups were administered hydrocortisone sodium succinate via intramuscular injection to induce a cold deficiency syndrome model. After 14 consecutive days, each ARLP decoction pieces was administered via continuous gastric lavage at a dose of 12 g·kg-1·d-1 for 7 d, while the control and model groups received an equivalent volume of physiological saline. After the end of administration, body weight, spleen weight and thymus weight were measured for calculating the spleen and thymus indexes. Hematoxylin-eosin(HE) staining was used to observe the pathological morphology of adrenal tissue. The fully automatic biochemistry analyzer was used to measure the total cholesterol(TC), triglyceride(TG), lactic dehydrogenase(LDH) and lactate(LAC) levels in serum. Enzyme-linked immunosorbent assay(ELISA) was employed to measure the contents of 17-hydroxycorticosteroid(17-OHCS), cortisol(CORT), triiodothyronine(T3), thyroxine(T4), thyrotropin(TSH), immunoglobulin(Ig) M, IgG, cyclic adenosine monophosphate(cAMP) and cyclic guanosine monophosphate(cGMP). Western blot was used to measure the protein expression levels of protein kinase A(PKA), cAMP response element-binding protein(CREB), silent information regulator 1(Sirt1) and peroxisome proliferator-activated receptor γ coactivator-1α(PGC-1α). And high performance liquid chromatography(HPLC) was used to determine the content of major alkaloids, followed by Pearson correlation analysis with pharmacodynamic indicators. ResultsAfter modeling, compare with the control group, the model rats exhibited symptoms such as lethargy and loose stools, mild abnormalities were observed in adrenal tissue structure, and both spleen and thymus indices were significantly reduced(P<0.01). Thyroid, adrenal and immune system functions were suppressed, with decreased serum cAMP level and significantly elevated cGMP level(P<0.01). Compared with the model group, the adrenal injury by hydrocortisone sodium succinate were repaired and the spleen index were increased significantly in all four ARLP groups(P<0.05, P<0.01). The thymus index in SFP and PFZ groups were increased significantly(P<0.05). The contents of T3, TSH, 17-OHCS and CORT were increased significantly in SFP and PFZ groups(P<0.05). In addition, the content of IgG in SFP, PFZ and PFP groups were increased significantly(P<0.01), while the content of IgM in PFZ and HSP groups were also increased significantly(P<0.05). Regarding the cyclic nucleotide system, PFZ significantly elevated cAMP level while reducing cGMP level(P<0.05), exhibiting the most pronounced effect among the four decoction pieces. For energy metabolism indicators, PFZ significantly improved abnormal markers including TC, TG, LDH, and LAC(P<0.05). HSP showed marked improvement effects on TG, LDH, and LAC(P<0.05). Both PFZ and SFP significantly elevated the expression levels of PKA, CREB, Sirt1, and PGC-1α proteins(P<0.01). Additionally, the diester alkaloids in ARLP showed a strong positive correlation with TG, IgG, and CORT, a strong negative correlation with LAC, a moderate positive correlation with T4, and moderate negative correlations with cAMP and spleen index. Monomeric alkaloids showed strong positive correlations with TG and IgG, strong negative correlations with LAC, moderate positive correlations with CORT and T4, and moderate negative correlations with cAMP and spleen index. However, the content of water-soluble alkaloids showed strong positive correlations with TC, LDH, 17-OHCS, T3, TSH, and thymus index, moderate positive correlations with cAMP, CORT, T4, and spleen index, and moderate negative correlation with cGMP. ConclusionAmong different processed ARLP decoction pieces, PFZ processed according to ZHANG Zhongjing's method exhibits the most potent warming and cold-dispelling effects. Its pharmacological actions are mediated through regulating the thyroid, adrenal, immune, cyclic nucleotide systems, and material-energy metabolism pathways. Among these, water-soluble alkaloids show strong or moderate correlations with more indicators of deficiency-cold syndrome and exhibit the highest content in PFZ. Therefore, PFZ processed according to ZHANG Zhongjing's method may exert its warming and cold-dispelling effects through water-soluble alkaloids.
2.Establishment of visualized LAMP assay targeting rcsA gene for rapid detection of Klebsiella pneumoniae
Yushan CHEN ; Qian HU ; Lin XIANG ; Jia YAN ; Jiawei LIU ; Qiguang LI ; Linhai LI ; Lingqing XU
Chinese Journal of Nosocomiology 2025;35(10):1450-1454
OBJECTIVE To establish a visualized loop-mediated isothermal amplification(LAMP)for rapid detec-tion of Klebsiella pneumoniae and evaluate the sensitivity and specificity of the detection method.METHODS To-tally4 specific LAMP primers were designed by targeting to rcsA gene of the K.pneumoniae.The reaction condi-tions(temperature,time)and the parameters of the reaction system were optimized,the reaction was made visu-alized by using chimeric fluorescent dye SYBR Green Ⅰ.The optimal reactions conditions and reaction systems were determined based on the results of visualization and agarose gel electrophoresis.The optimized conditions and systems were used to test the sensitivity by diluting DNA template on a 10-fold gradient,meanwhile,the specifici-ty of the method was evaluated by detecting K.pneumoniae and other ten species of common bacteria and fungi.RESULTS The optimal reaction temperature was 63 ℃ after the optimization,with the reaction time 35 min;the concentration of buffer solution in the reaction system was determined as 0.8×,with the concentration of magne-sium ion 8 mmol/L,the concentration of dNTPs 1.4 mmol/L,the ratio of internal to external primers 6∶1,the concentration of Bst DNA polymerase 0.32 U/μl,the concentration of betaine 0.75 mmol/L.For the test of sensi-tivity,the method could detect the template with the concentration of 1.5 ng/μl.For the test of specificity,only the detection of K.pneumoniae could display positive visualized result and positive electrophoretic band.CONCLUSIONS The visualized LAMP with high specificity and sensitivity for rapid detection of K.pneumoniae is successfully established,facilitating the observation of the detection result without the use of precise instruments.It is suitable for the detection in grass-root laboratories after successful preliminary application in clinical detection.
3.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
4.Establishment of a LC-MS/MS method for detecting gamma-aminobutyric acid in plasma and its clinical application
Jia-qian QIN ; Lei CAO ; Ying-fei PENG ; Fang-jun CHEN ; Bai-shen PAN ; Bei-li WANG ; Wei GUO
Fudan University Journal of Medical Sciences 2025;52(5):708-716
Objective To establish a stable liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for detecting gamma-aminobutyric acid(GABA)in plasma,and to evaluate the value of GABA detection in the diagnosis of sleep disorders.Methods GABA was detected using a UPLC Xevo TQs system.The method was pre-validated and its performance was verified to establish a reference range for healthy individuals.The difference in plasma GABA levels between apparently healthy individuals and patients with sleep disorders was compared.Results We employed deuterated compounds as isotopic internal standards and utilized an Amide chromatographic column for separation.The mobile phase was 0.050%formic acid in water and 90%acetonitrile in water containing 0.175%formic acid and 5 mmol/L ammonium acetate with gradient elution in the column temperature of 35℃.The linear range for the detection of GABA by LC-MS/MS was 0.05-10.00 μmol/L,with a lower limit of quantification of 0.02 μmol/L,the inter-day CV<3.00%and intra assay CV<4.00%,respectively,and the recovery rate was 101.06%-109.02%.The reference ranges for plasma GABA were established by analyzing 300 healthy controls stratified by age:18-34 years(0.08-0.15 μmol/L),35-49 years(0.10-0.20 μmol/L),and≥50 years(0.12-0.23 μmol/L).Then plasma GABA was used as a biomarker for auxiliary diagnosis of sleep disorders in analyzing 221 patients and 300 healthy controls,which revealed that AUC values were 0.510(P=0.850),0.686(P=0.002),and 0.890(P<0.001)in the groups of 18-34 years,35-49 years,and≥50 years,respectively,with optimal cut-off values of 0.09,0.10 and 0.11 μmol/L.Conclusion A reliable LC-MS/MS method for detecting GABA has been established,which can detect plasma GABA levels sensitively and accurately and can be used in assisting the clinical diagnosis of sleep disorders.
5.Establishment of visualized LAMP assay targeting rcsA gene for rapid detection of Klebsiella pneumoniae
Yushan CHEN ; Qian HU ; Lin XIANG ; Jia YAN ; Jiawei LIU ; Qiguang LI ; Linhai LI ; Lingqing XU
Chinese Journal of Nosocomiology 2025;35(10):1450-1454
OBJECTIVE To establish a visualized loop-mediated isothermal amplification(LAMP)for rapid detec-tion of Klebsiella pneumoniae and evaluate the sensitivity and specificity of the detection method.METHODS To-tally4 specific LAMP primers were designed by targeting to rcsA gene of the K.pneumoniae.The reaction condi-tions(temperature,time)and the parameters of the reaction system were optimized,the reaction was made visu-alized by using chimeric fluorescent dye SYBR Green Ⅰ.The optimal reactions conditions and reaction systems were determined based on the results of visualization and agarose gel electrophoresis.The optimized conditions and systems were used to test the sensitivity by diluting DNA template on a 10-fold gradient,meanwhile,the specifici-ty of the method was evaluated by detecting K.pneumoniae and other ten species of common bacteria and fungi.RESULTS The optimal reaction temperature was 63 ℃ after the optimization,with the reaction time 35 min;the concentration of buffer solution in the reaction system was determined as 0.8×,with the concentration of magne-sium ion 8 mmol/L,the concentration of dNTPs 1.4 mmol/L,the ratio of internal to external primers 6∶1,the concentration of Bst DNA polymerase 0.32 U/μl,the concentration of betaine 0.75 mmol/L.For the test of sensi-tivity,the method could detect the template with the concentration of 1.5 ng/μl.For the test of specificity,only the detection of K.pneumoniae could display positive visualized result and positive electrophoretic band.CONCLUSIONS The visualized LAMP with high specificity and sensitivity for rapid detection of K.pneumoniae is successfully established,facilitating the observation of the detection result without the use of precise instruments.It is suitable for the detection in grass-root laboratories after successful preliminary application in clinical detection.
6.Effect of dodecanoylcarnitine and myristoleic acid on the cellular function of mouse alveolar epithelial cell line of MLE-12
Yuan MA ; Ting ZHANG ; Zhi-long JIANG ; Jia-meng GAO ; Yu-hao QIAN ; Zhi-hong CHEN
Fudan University Journal of Medical Sciences 2025;52(3):333-342
Objective To explore the effects of dodecanoylcarnitine(DA)and myristoleic acid(MA)on the function of mouse alveolar epithelial cell line MLE-12 and their underlying mechanisms.Methods An inflammatory model was established by stimulating MLE-12 cells with IL-4.The expression levels of DA,MA,and sphingosine-1-phosphate(S1P)in the cell supernatant were detected by ELISA.MLE-12 cells were separately intervened with DA and MA.RT-PCR and flow cytometry were used to detect the expression changes of inflammatory factors IL-6 and tumor necrosis factor-α(TNF-α)and the level of intracellular reactive oxygen species(ROS).Additionally,Western blot was performed to detect the expression of key proteins such as p38 mitogen-activated protein kinase(p-38 MAPK)and src homology 2 domain-containing phosphatase 1(SHP-1).To explore the role of S1PR2 in the effects of DA and MA,MLE-12 cells were pretreated with the S1PR2 inhibitor JTE-013,and the above experiments were repeated.Results IL-4 stimulation significantly upregulated the levels of DA,MA,and S1P in MLE-12 cells(P<0.05).DA/MA treatment groups exhibited significantly increased expression of IL-6 and TNF-α compared with the control group(P<0.05),along with elevated ROS levels(P<0.05).Western blot analysis revealed that DA/MA promoted SHP-1 dephosphorylation and phosphorylated p38 MAPK activation in MLE-12 cells.Notably,JTE-013 pre-treatment completely reversed these effects(P<0.05).Conclusion Asthma-related metabolites DA and MA exacerbate the inflammatory and oxidative stress responses of MLE-12 cells by activating the S1PR2 receptor,promoting the dephosphorylation of SHP-1 and the activation of the p-p38 MAPK pathway.This study reveals the core regulatory role of S1PR2 in this pathway as well.
7.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
8.Effect of dodecanoylcarnitine and myristoleic acid on the cellular function of mouse alveolar epithelial cell line of MLE-12
Yuan MA ; Ting ZHANG ; Zhi-long JIANG ; Jia-meng GAO ; Yu-hao QIAN ; Zhi-hong CHEN
Fudan University Journal of Medical Sciences 2025;52(3):333-342
Objective To explore the effects of dodecanoylcarnitine(DA)and myristoleic acid(MA)on the function of mouse alveolar epithelial cell line MLE-12 and their underlying mechanisms.Methods An inflammatory model was established by stimulating MLE-12 cells with IL-4.The expression levels of DA,MA,and sphingosine-1-phosphate(S1P)in the cell supernatant were detected by ELISA.MLE-12 cells were separately intervened with DA and MA.RT-PCR and flow cytometry were used to detect the expression changes of inflammatory factors IL-6 and tumor necrosis factor-α(TNF-α)and the level of intracellular reactive oxygen species(ROS).Additionally,Western blot was performed to detect the expression of key proteins such as p38 mitogen-activated protein kinase(p-38 MAPK)and src homology 2 domain-containing phosphatase 1(SHP-1).To explore the role of S1PR2 in the effects of DA and MA,MLE-12 cells were pretreated with the S1PR2 inhibitor JTE-013,and the above experiments were repeated.Results IL-4 stimulation significantly upregulated the levels of DA,MA,and S1P in MLE-12 cells(P<0.05).DA/MA treatment groups exhibited significantly increased expression of IL-6 and TNF-α compared with the control group(P<0.05),along with elevated ROS levels(P<0.05).Western blot analysis revealed that DA/MA promoted SHP-1 dephosphorylation and phosphorylated p38 MAPK activation in MLE-12 cells.Notably,JTE-013 pre-treatment completely reversed these effects(P<0.05).Conclusion Asthma-related metabolites DA and MA exacerbate the inflammatory and oxidative stress responses of MLE-12 cells by activating the S1PR2 receptor,promoting the dephosphorylation of SHP-1 and the activation of the p-p38 MAPK pathway.This study reveals the core regulatory role of S1PR2 in this pathway as well.
9.Study on performance evaluation method for lubricating coatings of intravascular catheters
Hong-jian CHEN ; Chong-chong AI ; Yuan-yu LI ; Li-ping HUANG ; Jia-qi NIE ; Chang-bin WANG ; Qian YANG ; Yu-xin BI ; Wen-bo LU
Chinese Medical Equipment Journal 2025;46(1):66-72
Three evaluation methods were recommended for the key properties of the intravascular catheter lubricating coating such as stability,lubricity and integrity,including insoluble particle test method,friction test procedure and appearance detection method.Fifteen batches of microcatheters produced by different manufacturers were selected for testing to clarify the three methods in test principle,step,result,characteristic.References were provided for the design,production,evaluation and regulation of intravascular catheters with lubricant coatings.[Chinese Medical Equipment Journal,2025,46(1):66-72]
10.Establishment of a LC-MS/MS method for detecting gamma-aminobutyric acid in plasma and its clinical application
Jia-qian QIN ; Lei CAO ; Ying-fei PENG ; Fang-jun CHEN ; Bai-shen PAN ; Bei-li WANG ; Wei GUO
Fudan University Journal of Medical Sciences 2025;52(5):708-716
Objective To establish a stable liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for detecting gamma-aminobutyric acid(GABA)in plasma,and to evaluate the value of GABA detection in the diagnosis of sleep disorders.Methods GABA was detected using a UPLC Xevo TQs system.The method was pre-validated and its performance was verified to establish a reference range for healthy individuals.The difference in plasma GABA levels between apparently healthy individuals and patients with sleep disorders was compared.Results We employed deuterated compounds as isotopic internal standards and utilized an Amide chromatographic column for separation.The mobile phase was 0.050%formic acid in water and 90%acetonitrile in water containing 0.175%formic acid and 5 mmol/L ammonium acetate with gradient elution in the column temperature of 35℃.The linear range for the detection of GABA by LC-MS/MS was 0.05-10.00 μmol/L,with a lower limit of quantification of 0.02 μmol/L,the inter-day CV<3.00%and intra assay CV<4.00%,respectively,and the recovery rate was 101.06%-109.02%.The reference ranges for plasma GABA were established by analyzing 300 healthy controls stratified by age:18-34 years(0.08-0.15 μmol/L),35-49 years(0.10-0.20 μmol/L),and≥50 years(0.12-0.23 μmol/L).Then plasma GABA was used as a biomarker for auxiliary diagnosis of sleep disorders in analyzing 221 patients and 300 healthy controls,which revealed that AUC values were 0.510(P=0.850),0.686(P=0.002),and 0.890(P<0.001)in the groups of 18-34 years,35-49 years,and≥50 years,respectively,with optimal cut-off values of 0.09,0.10 and 0.11 μmol/L.Conclusion A reliable LC-MS/MS method for detecting GABA has been established,which can detect plasma GABA levels sensitively and accurately and can be used in assisting the clinical diagnosis of sleep disorders.

Result Analysis
Print
Save
E-mail