1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Discussion on processing time for Polygonatum kingianum based on analysis of correlation between sugar components and color changes
GUO Hong ; YAO Rui ; LI Zhe ; FAN Jing ; WANG Ying ; GUO Xiaohan ; CHEN Jia ; DUAN Baozhong ; YANG Jianbo ; JING Wenguang ; CHENG Xianlong ; WEI Feng
Drug Standards of China 2026;27(1):0083-0091
Objective: To investigate the correlation between color parameters (L*, a*, b*, Eab*) and the contents of reducing sugars, total polysaccharides, total oligosaccharides, as well as four saccharides (fructose, glucose, sucrose, and kestose) during the nine cycles of steaming and sun-drying processing of Polygonatum kingianum, and to preliminarily explore the optimal processing duration.
Methods: The color changes were objectively evaluated using a colorimeter. The anthrone-sulfuric acid method was employed to determine total polysaccharides and oligosaccharides. The 3,5-dinitrosalicylic acid (DNS) colorimetric method was used to measure total reducing sugar content. High-performance liquid chromatography coupled with charged aerosol detection (HPLC-CAD) was applied for quantitative analysis of fructose, glucose, sucrose, and kestose. Multivariate statistical analysis was conducted to assess samples from different processing stages.
Results: Significant variations in color and component contents were observed across processing stages. The herbal pieces progressively darkened with increased processing cycles: brightness (L*) and total color difference (Eab*) initially decreased then stabilized, while a* (red-green) and b* (yellow-blue) values first increased then declined. Total polysaccharides and oligosaccharides showed overall decreasing trends, whereas reducing sugars initially increased before stabilizing. Fructose and glucose levels rose continuously, while sucrose and kestose decreased progressively, becoming undetectable after five cycles.
Conclusion: The chromatic alteration and saccharide composition of P. kingianum showed significant correlation with processing duration. Both total color difference (Eab*) and reducing sugar content stabilized after four processing cycles (12 hours), suggesting that four cycles of steaming and sun-drying may represent the optimal processing duration.
3.Analytical research on processing techniques of Polygoni Multiflori Radix Praeparata based on chemical composition and color changes correlation
YAO Rui ; GUO Hong ; LI Zhe ; GUO Xiaohan ; ZHANG Xiaoshu ; DUAN Baozhong ; YANG Jianbo ; CHEN Jia ; JING Wenguang ; CHENG Xianlong ; WEI Feng
Drug Standards of China 2026;27(1):0100-0108
Objective: To investigate the correlation between the color parameters (L*, a*, b*, Eab* values) of Polygoni Multiflori Radix Praeparata powder prepared by different processing techniques and the contents of 2,3,5,4’-tetrahydroxystilbene-2-O-β-D-glucopyranoside, emodin, physcion, emodin-8-O-β-D-glucopyranoside, physcion-8-O-β-D-glucopyranoside.
Methods: The L*, a*, b* and Eab* values of Polygoni Multiflori Radix Praeparata powder prepared by different processing techniques were determined by spectrophotometer, and the contents of the five components were determined by high performance liquid chromatography. Secondly, SPSS 26.0 software and Simca 14.1 software were used to analyze the correlation.
Results: Through the hierarchical cluster analysis (HCA), it was found that the steamed samples and black bean steamed samples could be obviously divided into two categories: raw products and processed products. The processed products could be further divided into 2-8 h and 12-48 h. Pearson correlation analysis showed that the content of stilbene glycoside was significantly positively correlated with L*, a* and b* values (P<0.01). The a* value was significantly positively correlated with the content of emodin and physcion (P<0.01). Emodin-8-O-β-D-glucoside was positively correlated with L* value and b* value, while physcion-8-O-β-D-glucoside was negatively correlated with a* value. Partial least squares discriminant analysis (PLS) showed that 2,3,5,4’-tetrahydroxystilbene-2-O-β-D-glucoside (VIP=1.69) and emodin-8-O-β-D-glucoside (VIP=1.06) were the key variables affecting chromaticity characteristics (P<0.01).
Conclusion: The three processes of steaming, black bean steaming and black bean stewing are consistent in composition transformation and chromaticity variation, and stilbene glycoside can be used as a specific index component to characterize the processed color. Chromatic parameters can effectively reflect the processing progression and serve as quality monitoring indicators during production.
4.The SMAD-Pathway Mediates HMGB1-Induced Proliferation and Metastatic Progression in Cutaneous Squamous Cell Carcinoma Cells
De-De LIAN ; Xue Mei LI ; Yu-Xi JIA ; Ming-Wei ZHOU ; Xiang-Ru CHEN ; Yang-Yang TIAN ; Min LI ; Ming-Hui SUN ; Ye ZHAO ; Hong-Jun LI ; Qing-Ling ZHANG
Annals of Dermatology 2026;38(1):51-58
Background:
High-mobility group box protein 1 (HMGB1) is a chromatin-binding protein involved in arthritis, ischemia, sepsis, atherosclerosis, neurodegenerative disorders, meningitis, and cancer. HMGB1 exhibits dual roles in cancer, acting as either a tumor suppressor or oncoprotein depending on context.
Objective:
This research aimed to elucidate HMGB1’s functional significance in cutaneous squamous cell carcinoma (cSCC).
Methods:
We overexpressed HMGB1 in cSCC cell lines using recombinant adenovirus and examined its effects on cell proliferation, colony formation, and cell migration.
Results:
Immunohistochemical analysis revealed elevated HMGB1 expression levels in cSCC tissue relative to normal epidermis. To assess the influence of HMGB1, we employed recombinant adenoviruses expressing HMGB1 to transduce SCC cell lines (SCC12 and SCC13). Enhanced HMGB1 expression significantly promoted cellular proliferation and colony formation capacity.Notably, HMGB1 overexpression elevated the levels of proliferation regulators, including P63, SOX2, CDK4 and CDK6. Furthermore, HMGB1 overexpression substantially enhanced tumor invasiveness, accompanied by upregulation of epithelial-mesenchymal transition (EMT) biomarkers. Mechanistically, overexpression of HMGB1 enhanced transforming growth factor-β signaling by increasing phosphorylation of SMAD2/3, the key mediators of EMT.
Conclusion
These data imply that HMGB1 acts as a tumor-promoting factor in cSCC.
5.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
6.The Effect of Platelet Irradiation on the Efficacy and Safety of Platelet Transfusion in Children with Hematological Disorders
Xin CHEN ; Qin LIU ; Hao LI ; Jia WANG ; Hong-Bing HU
Journal of Experimental Hematology 2025;33(6):1774-1778
Objective:To investigate the effect of platelet irradiation on the efficacy and safety of platelet transfusion in children with hematological disorders.Methods:The platelet transfusion of 56 pediatric patients in the Hematology Department of Wuhan Children's Hospital from January to December 2023 were retrospective analyzed.According to whether the platelets transfused by the patient have been irradiated,they are divided into irradiation group and non irradiation group.The effect of platelet irradiation on efficacy rate of transfusion and incidence of transfusion adverse reactions was analyzed.Results:Fifty-six patients with hematological disorders received 608 platelet transfusions,with 83 transfusions ineffective and an inefficiency rate of 13.65%.Twenty-nine times of adverse transfusion reactions occurred,with a transfusion reaction incidence rate of 4.77%.The 24-hour CCI value of the irradiation group was lower than that of the non irradiation group(Z=4.120,P<0.01),and the effective rate of transfusion in the irradiation group was lower than that in the non irradiation group(x2=8.595,P<0.01).The incidence of adverse reactions during transfusion in the irradiation group was lower than that in the non irradiation group(x2=4.153,P<0.05).In children with acute leukemia,there were statistical differences in 24 h CCI,the effective rate of transfusion,and adverse transfusion reactions between the irradiation and non-irradiation groups.Conclusion:Platelet irradiation can reduce the effective rate of platelet transfusion in children with hematological disorders,but can reduce the incidence of adverse transfusion reactions.To ensure the safety of blood use for pediatric patients,it is recommended to transfuse irradiated platelets to individuals who are susceptible to transfusion associated graft-versus-host disease(TA-GVHD),especially children with acute leukemia.
7.Standardized scheme for deploying and withdrawing surgical module of new-type tent hospital system
Zeng-biao SU ; Bin-hong PEI ; Er-xiang XU ; Hai-ying CHEN ; Jia-na CHEN ; Jin-shen PAN ; Yi-feng HUANG ; Qian XU
Chinese Medical Equipment Journal 2025;46(2):74-79
Objective To explore the scheme for the deployment and withdrawal of the surgical module of the new-type tent hospital system.Methods A set of standardized scheme for deploying and withdrawing the surgical module of the new-type tent hosital system was proposed and implemented in terms of labor division,operation precedure,operation technique and precaution.The operating time,number of operational errors and number of equipment damages were recorded for each of the five deployment and withdrawal operations before and after the program was executed,and the team members'immediate heart rate,percentage of maximum heart rate(MHR)and rating of perceived exercise(RPE)at the end of the operation were recorded after the program was implemented.SPSS 26.0 software was used for statistical analysis.Results The standardized scheme had the deployment time shortened from(85.15±11.430)min to(58.23±8.513)min,withdrawal time decreased from(65.36±9.369)min to(48.92±7.129)min,with the differences being statistically significant(P<0.05);the numbers of operatio-nal errors and equipment damages were both reduced when compared with those before the implementation of the schemce;the immediate heart rate of the team members at the end of the operation ranged from 43 to 157 beats/min,with an average value of 151.1 beats/min,the individual MHR percentages were from 75%to 87%,with an average value of 81.1%,and the RPE scores were from 14 to 17,with an average value of 15.3,which all could be categorized as moderate-operation intensity.Condusion The standardized deployment and withdrawal scheme for the surgical module meets the needs of actual combat and training assessment,and thus is worthy promoting in medical institutions equipped with the surgical module of the new-type tent hosital system.[Chinese Medical Equipment Journal,2025,46(2):74-79]
8.Guideline for assessment and maintenance of intrinsic capacity in older adults
Wenjing LIU ; Zhiwen WANG ; Yuelin YU ; Xin REN ; Hui JU ; Hong CHEN ; Junxin WANG ; Shan-shan CHEN ; Jia ZHOU ; Mo YI ; Wenxia WANG ; Lingjuan ZHANG ; Siye CHEN ; Yufan YANG ; Xiaomeng WANG ; Hong SUN
Chinese Journal of Nursing 2025;60(3):261-265
Objective This study aims to develop a guideline for assessing and maintaining intrinsic capacity in older adults,offer recommendations to professionals regarding these assessments,and encourage the implementation of evidence-based clinical practices across various settings,including communities,hospitals,nursing homes,and other geriatric care environments.Methods An evidence-based approach guided the collection of questions through a lit-erature review.Preliminary recommendations were developed through a systematic search of domestic and interna-tional guideline networks,professional association websites,and comprehensive databases.Subsequently,the recom-mendations were revised,and the consensus was achieved through a round of expert consensus meetings and 3 rounds of expert correspondence,culminating in the formation of the guidelines.Results The developed guideline encompasses 2 aspects and 5 dimensions of assessment and maintenance,comprising a total of 28 questions and 39 recommendations.Specifically,6 questions and 9 recommendations were formulated for the cognitive dimension,5 questions and 7 recommendations for the locomotion dimension,6 questions and 7 recommendations for the vitality dimension,6 questions and 9 recommendations for the psychological dimension,and 5 questions and 7 recommenda-tions for the sensory dimension.Among these,34 are classified as strong recommendations,while 5 are categorized as weak recommendations.Conclusion The guideline offers scientifically robust,acceptable,and comprehensible rec-ommendations that equip the professionals with a foundation for decision-making aiming at preserving the intrinsic capacity of older adults.
9.Quality consistency evaluation of Tongmai preparations
Jia-hui XU ; Yu-hong LIU ; Zhi-fang HUANG ; Yun-hua LIU ; Yan CHEN ; Ting-ting XU ; Jin-hai YI
Chinese Traditional Patent Medicine 2025;47(3):709-716
AIM To evaluate the quality consistency of Tongmai Granules,Tongmai Tablets,Tongmai Capsules and Tongmai Oral Liquid.METHODS The HPLC fingerprints were established,after which the contents of danshensu,protocatechuic aldehyde,3'-hydroxy puerarin,puerarin,puerarin apioside,daidzin,ferulic acid,salvianolic acid B and salvianolic acid A were determined,and cluster analysis and principal component analysis were adopted in the quality analysis from the perspective of daily intake.RESULTS There were 21 common peaks in the fingerprints for 39 batches of samples with the similarities of 0.765-0.997.Various batches of samples were clustered into 5 categories,2 principal components demonstrated the accumulative variance contribution rate of 83.53% .The daily intakes of various constituents in different dosage forms exhibited obvious differences,especially for that of salvianolic acid B,which were low in tablets and capsules,and their heterogeneities existed among the same dosage forms.CONCLUSION This simple and accurate method can provide a reference for the quality evaluation of Tongmai preparations from different manufacturers.
10.Distribution and resistance profiles of bacterial strains isolated from cerebrospinal fluid in hospitals across China:results from the CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Juan MA ; Lixia ZHANG ; Yang YANG ; Fupin HU ; Demei ZHU ; Han SHEN ; Wanqing ZHOU ; Wenen LIU ; Yanming LI ; Yi XIE ; Mei KANG ; Dawen GUO ; Jinying ZHAO ; Zhidong HU ; Jin LI ; Shanmei WANG ; Yafei CHU ; Yunsong YU ; Jie LIN ; Yingchun XU ; Xiaojiang ZHANG ; Jihong LI ; Bin SHAN ; Yan DU ; Ping JI ; Fengbo ZHANG ; Chao ZHUO ; Danhong SU ; Lianhua WEI ; Fengmei ZOU ; Xiaobo MA ; Yanping ZHENG ; Yuanhong XU ; Ying HUANG ; Yunzhuo CHU ; Sufei TIAN ; Hua YU ; Xiangning HUANG ; Sufang GUO ; Xuesong XU ; Chao YAN ; Fangfang HU ; Yan JIN ; Chunhong SHAO ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Fang DONG ; Zhiyong LÜ ; Lei ZHU ; Jinhua MENG ; Shuping ZHOU ; Yan ZHOU ; Chuanqing WANG ; Pan FU ; Yunjian HU ; Xiaoman AI ; Ziyong SUN ; Zhongju CHEN ; Hong ZHANG ; Chun WANG ; Yuxing NI ; Jingyong SUN ; Kaizhen WEN ; Yirong ZHANG ; Ruyi GUO ; Yan ZHU ; Jinju DUAN ; Jianbang KANG ; Xuefei HU ; Shifu WANG ; Yunsheng CHEN ; Qing MENG ; Yong ZHAO ; Ping GONG ; Ruizhong WANG ; Hua FANG ; Jilu SHEN ; Jiangshan LIU ; Hongqin GU ; Jiao FENG ; Shunhong XUE ; Bixia YU ; Wen HE ; Lin JIANG ; Longfeng LIAO ; Chunlei YUE ; Wenhui HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(3):279-289
Objective To investigate the distribution and antimicrobial resistance profiles of common pathogens isolated from cerebrospinal fluid(CSF)in CHINET program from 2015 to 2021.Methods The bacterial strains isolated from CSF were identified in accordance with clinical microbiology practice standards.Antimicrobial susceptibility test was conducted using Kirby-Bauer method and automated systems per the unified CHINET protocol.Results A total of 14 014 bacterial strains were isolated from CSF samples from 2015 to 2021,including the strains isolated from inpatients(95.3%)and from outpatient and emergency care patients(4.7%).Overall,19.6%of the isolates were from children and 80.4%were from adults.Gram-positive and Gram-negative bacteria accounted for 68.0%and 32.0%,respectively.Coagulase negative Staphylococcus accounted for 73.0%of the total Gram-positive bacterial isolates.The prevalence of MRSA was 38.2%in children and 45.6%in adults.The prevalence of MRCNS was 67.6%in adults and 69.5%in children.A small number of vancomycin-resistant Enterococcus faecium(2.2%)and linezolid-resistant Enterococcus faecalis(3.1%)were isolated from adult patients.The resistance rates of Escherichia coli and Klebsiella pneumoniae to ceftriaxone were 52.2%and 76.4%in children,70.5%and 63.5%in adults.The prevalence of carbapenem-resistant E.coli and K.pneumoniae(CRKP)was 1.3%and 47.7%in children,6.4%and 47.9%in adults.The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)and Pseudomonas aeruginosa(CRPA)was 74.0%and 37.1%in children,81.7%and 39.9%in adults.Conclusions The data derived from antimicrobial resistance surveillance are crucial for clinicians to make evidence-based decisions regarding antibiotic therapy.Attention should be paid to the Gram-negative bacteria,especially CRKP and CRAB in central nervous system(CNS)infections.Ongoing antimicrobial resistance surveillance is helpful for optimizing antibiotic use in CNS infections.

Result Analysis
Print
Save
E-mail