1.Randomized, double-blind, parallel-controlled, multicenter, equivalence clinical trial of Jiuwei Xifeng Granules(Os Draconis replaced by Ostreae Concha) for treating tic disorder in children.
Qiu-Han CAI ; Cheng-Liang ZHONG ; Si-Yuan HU ; Xin-Min LI ; Zhi-Chun XU ; Hui CHEN ; Ying HUA ; Jun-Hong WANG ; Ji-Hong TANG ; Bing-Xiang MA ; Xiu-Xia WANG ; Ai-Zhen WANG ; Meng-Qing WANG ; Wei ZHANG ; Chun WANG ; Yi-Qun TENG ; Yi-Hui SHAN ; Sheng-Xuan GUO
China Journal of Chinese Materia Medica 2025;50(6):1699-1705
Jiuwei Xifeng Granules have become a Chinese patent medicine in the market. Because the formula contains Os Draconis, a top-level protected fossil of ancient organisms, the formula was to be improved by replacing Os Draconis with Ostreae Concha. To evaluate whether the improved formula has the same effectiveness and safety as the original formula, a randomized, double-blind, parallel-controlled, equivalence clinical trial was conducted. This study enrolled 288 tic disorder(TD) of children and assigned them into two groups in 1∶1. The treatment group and control group took the modified formula and original formula, respectively. The treatment lasted for 6 weeks, and follow-up visits were conducted at weeks 2, 4, and 6. The primary efficacy endpoint was the difference in Yale global tic severity scale(YGTSS)-total tic severity(TTS) score from baseline after 6 weeks of treatment. The results showed that after 6 weeks of treatment, the declines in YGTSS-TSS score showed no statistically significant difference between the two groups. The difference in YGTSS-TSS score(treatment group-control group) and the 95%CI of the full analysis set(FAS) were-0.17[-1.42, 1.08] and those of per-protocol set(PPS) were 0.29[-0.97, 1.56], which were within the equivalence boundary [-3, 3]. The equivalence test was therefore concluded. The two groups showed no significant differences in the secondary efficacy endpoints of effective rate for TD, total score and factor scores of YGTSS, clinical global impressions-severity(CGI-S) score, traditional Chinese medicine(TCM) response rate, or symptom disappearance rate, and thus a complete evidence chain with the primary outcome was formed. A total of 6 adverse reactions were reported, including 4(2.82%) cases in the treatment group and 2(1.41%) cases in the control group, which showed no statistically significant difference between the two groups. No serious suspected unexpected adverse reactions were reported, and no laboratory test results indicated serious clinically significant abnormalities. The results support the replacement of Os Draconis by Ostreae Concha in the original formula, and the efficacy and safety of the modified formula are consistent with those of the original formula.
Adolescent
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Male
;
Double-Blind Method
;
Drugs, Chinese Herbal/therapeutic use*
;
Tic Disorders/drug therapy*
;
Treatment Outcome
2.Expression and Clinical Significance of lncRNA NCK1-AS1 in Acute Myeloid Leukemia.
Chen CHENG ; Zi-Jun XU ; Pei-Hui XIA ; Xiang-Mei WEN ; Ji-Chun MA ; Yu GU ; Di YU ; Jun QIAN ; Jiang LIN
Journal of Experimental Hematology 2025;33(2):352-358
OBJECTIVE:
To detect and analyze the expression and clinical significance of long non-coding RNA tyrosine kinase non-catalytic region adaptor protein 1-antisense RNA1 (NCK1-AS1) in patients with acute myeloid leukemia (AML).
METHODS:
89 AML patients and 23 healthy controls were included from the People's Hospital Affiliated to Jiangsu University. Real-time quantitative polymerase chain reaction (RT-qPCR) was used to detect the expression levels of NCK1-AS1 and NCK1 in bone marrow samples. The relationship between the expression of NCK1-AS1 and the clinical characteristics of patients were analyzed, as well as the correlation between NCK1-AS1 and NCK1.
RESULTS:
The expression level of NCK1-AS1 in all AML, non-M3 AML and cytogenetically normal AML (CN-AML) patients was significantly higher than that in the control group (P < 0.01, P < 0.05, P < 0.01, respectively). In non-M3 AML, patients with high NCK1-AS1 expression had a significantly lower hemoglobin level than those with low NCK1-AS1 expression (P =0.036), furthermore, NCK1-AS1 high patients had shorter overall survival than NCK1-AS1low patients (P =0.0378). Multivariate analysis showed that NCK1-AS1 expression was an independent adverse factor in patients with non-M3 AML ( HR =2.392, 95% CI :1.089-5.255, P =0.030). In addition, NCK1 expression was also significantly upregulated in all AML, non-M3 AML and CN-AML patients compared with controls (P < 0.01, P < 0.01, P < 0.001, respectively). There was a certain correlation between NCK1-AS1 and NCK1 expression (r =0.37, P =0.0058).
CONCLUSION
High expression of NCK1-AS1 in AML indicates poor prognosis of AML patients.
Humans
;
Leukemia, Myeloid, Acute/genetics*
;
RNA, Long Noncoding/genetics*
;
Oncogene Proteins/genetics*
;
Adaptor Proteins, Signal Transducing/genetics*
;
Prognosis
;
Male
;
Female
;
Middle Aged
;
Adult
;
Case-Control Studies
;
Clinical Relevance
3.Effect of high ligation of spermatic vein on leukocytes in expressed prostate secretion of patients with chronic prostatitis and varicocele.
Ji-Yang DING ; Peng ZHANG ; Chun-Hua NIU ; Hai-Yong LI ; Wen-Zhu XU ; Ying-Chen ZHANG ; Gang MA
National Journal of Andrology 2025;31(4):319-322
OBJECTIVE:
To investigate the effect of laparoscopic high ligation of spermatic cord vein in patients with chronic prostatitis and varicocele prostatitis.
METHODS:
A total of 90 varicocele patients were selected from January 2016 to December 2020, including 33 patients with chronic prostatitis. Changes of white blood cell count, National Institutes of Health chronic prostatitis symptom index (NIH-CPSI) score and serum testosterone level in the expressed prostate secretion (EPS) were observed before and after the operation of laparoscopic high ligation of spermatic vein.
RESULTS:
All patients were followed up three months after the surgery. There was no significant difference in the white blood cell counts in EPS, NIH-CPSI score, and serum testosterone level in patients with varicocele-only who underwent high ligation surgery after the operation. However, the white blood cell count in the EPS of patients with chronic prostatitis was lower than that before 3 months of operation ( [12.39±4.23]×109/L vs [21.36±5.05]×109/L). The NIH-CPSI score was significantly lower than that before operation ( [12.71±6.21] vs [26.76±8.43]). And the serum testosterone level was higher than that before operation ([4.34±1.77]ng/ml vs [2.36±1.05]ng/ml).
CONCLUSION
Laparoscopic high ligation of the spermatic vein in patients with chronic prostatitis and varicocele could effectively reduce the number of white blood cells in the EPS, boost the level of serum testosterone and improves symptoms of chronic prostatitis.
Male
;
Humans
;
Varicocele/surgery*
;
Prostatitis/blood*
;
Ligation
;
Spermatic Cord/blood supply*
;
Testosterone/blood*
;
Chronic Disease
;
Prostate/metabolism*
;
Veins/surgery*
;
Leukocyte Count
;
Leukocytes
;
Laparoscopy
;
Adult
4.Atomic Fluorescence Dispersion Detection Technique Based on Area Array Single Photon Counting Imaging Detector
Chen TAO ; Hong-Ji ZHANG ; Chun-Sheng LI ; Ling-Ping HE ; Zhen-Yu MA ; Bo CHEN ; Ran ZHANG
Chinese Journal of Analytical Chemistry 2025;53(2):187-194
The single photon counting imaging detector based on microchannel plate(MCP)has the characteristics of high sensitivity and low dark count rate,and has been applied to the optical remote sensing detection of weak ultraviolet spectral signals in space.In this work,by using planar array single photon counting imaging detector as the detector,flat-field concave grating as the splitter,and electrodeless discharge lamp(EDL)as the excitation light source,a dispersion detection system suitable for hydride generation-atomic fluorescence spectrometry(HG-AFS)was developed.The wavelength calibration of the system was carried out,and the negative high pressure and EDL stability time of the planar array single photon counting imaging detector were analyzed and optimized.The characteristic emission spectral lines of As and Bi elements excited in the wavelength range of 180-320 nm were analyzed,and the scattering interference in the wavelength range of 257.3-306.7 nm was discussed.The results showed that the AFS dispersion detection system based on the planar array single photon counting imaging detector could detect and analyze the HG-AFS fluorescence signal initially,and the influence of scattering interference on the detection results was effectively avoided.The system had the advantages including simple structure,no refrigeration and temperature control,no moving parts and simultaneous measurement of multi-band.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.PI3K/Akt pathway-based investigation of total Astragalus saponins on sarcopenia in a rat model of type 2 diabetes mellitus
Lei-Lei MA ; Ji-An LI ; Wen-Xuan XU ; Jing-Ya WANG ; Zhao-Yang TIAN ; Jia-Yu LI ; Ru-Jie HAN ; Xiao-Jin LA ; Chun-Yu TIAN ; Hong CHANG ; Zi-Yang DAI ; Bi-Wei ZHANG
Chinese Traditional Patent Medicine 2024;46(11):3612-3619
AIM To investigate the effects of total Astragalus saponins on the improvement of sarcopenia in a rat model of type 2 diabetes mellitus(T2DM).METHODS The rats were divided into the normal group for a normal feeding and the model group for the feeding of high-sugar and high-fat diet combined with intraperitoneal injection of STZ to establish a T2DM model.The successful model rats were randomly divided into the model group,the metformin group(0.2 g/kg)and the total Astragalus saponins group(80 mg/kg),and given corresponding doses of drugs by gavage.After 12 weeks administration,the rats had their FBG,postprandial blood glucose(PG2h)and wet weight of skeletal muscle measured;their serum levels of INS,C-peptide(C-P),IGF-1,TNF-α and IL-1β detected by ELISA;their morphological changes of skeletal muscle observed by HE staining;their protein expressions of PI3K,p-Akt,mTOR,S6K1,FoxO1 and Murf1 in skeletal muscle detected by Western blot;and their mRNA expressions of Pi3k,Akt and mtor in skeletal muscle detected by RT-qPCR method.RESULTS Compared with the model group,the total Astragalus saponins group displayed decreased levels of FBG,PG2h,OGTT-AUC,HOMA-IR,TNF-α and IL-1β(P<0.01);increased levels of INS,C-P,IGF-1 and wet weight of skeletal muscle(P<0.05,P<0.01);improved skeletal muscle atrophy and increased protein expressions of PI3K,p-Akt,mTOR and S6K1 in skeletal muscle(P<0.05,P<0.01);decreased protein expressions of FoxO1 and Murf1(P<0.05,P<0.01);and increased mRNA expressions of Pi3k,Akt and mtor(P<0.01).CONCLUSION The improvement effects of total Astragalus saponins on sarcopenia in T2DM rats may be associated with the regulation of PI3K/Akt/mTOR and PI3K/Akt/FoxO1 pathways.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.

Result Analysis