1.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
3.Higher Physical Activity is Associated with Reduced Lower Urinary Tract Symptoms in Korean Men
Seo Eun HWANG ; Jae Moon YUN ; Su Hwan CHO ; Kyungha MIN ; Ji Young KIM ; Hyuktae KWON ; Jin Ho PARK
The World Journal of Men's Health 2025;43(1):166-173
Purpose:
Identifying and managing risk factors for lower urinary tract symptoms (LUTS) is crucial because it impacts the quality of life of elderly individuals. Lifestyle factors, including physical activity (PA), and their relationship with LUTS have not been well studied. This objective of this study was to investigate the association between PA and LUTS.
Materials and Methods:
A total of 7,296 men were included in this cross-sectional study. PA was quantified in metabolic equivalent (MET)-hours per week, and LUTS severity was assessed using the international prostate symptom score. Logistic regression was used to analyze the association between PA and LUTS, including voiding and storage symptoms.
Results:
The average age of the participants was 57.8 years, and the prevalence of LUTS was 41.3%. After adjusting for potential confounders, PA was inversely associated with the prevalence and severity of moderate-to-severe LUTS, showing a dose-response pattern (all p for trend <0.01). Compared to the minimal activity group, which engaged in <5 MET-hours per week of PA, the odds ratios for moderate to severe LUTS were 0.83 (95% confidence interval [CI]: 0.72–0.97) for men engaging in 15–30 MET-hours per week, 0.82 (95% CI: 0.71–0.95) for 30–60 MET-hours per week, and 0.72 (95% CI: 0.62–0.84) for ≥60 MET-hours per week. The possible protective effect of PA was still observed in the additional analysis for voiding and storage symptoms showing the same dose-response pattern (all p for trend <0.01).
Conclusions
A higher PA level was associated with a lower prevalence and severity of total, voiding, and storage LUTS in a dose-dependent manner in Korean men.
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
5.Higher Physical Activity is Associated with Reduced Lower Urinary Tract Symptoms in Korean Men
Seo Eun HWANG ; Jae Moon YUN ; Su Hwan CHO ; Kyungha MIN ; Ji Young KIM ; Hyuktae KWON ; Jin Ho PARK
The World Journal of Men's Health 2025;43(1):166-173
Purpose:
Identifying and managing risk factors for lower urinary tract symptoms (LUTS) is crucial because it impacts the quality of life of elderly individuals. Lifestyle factors, including physical activity (PA), and their relationship with LUTS have not been well studied. This objective of this study was to investigate the association between PA and LUTS.
Materials and Methods:
A total of 7,296 men were included in this cross-sectional study. PA was quantified in metabolic equivalent (MET)-hours per week, and LUTS severity was assessed using the international prostate symptom score. Logistic regression was used to analyze the association between PA and LUTS, including voiding and storage symptoms.
Results:
The average age of the participants was 57.8 years, and the prevalence of LUTS was 41.3%. After adjusting for potential confounders, PA was inversely associated with the prevalence and severity of moderate-to-severe LUTS, showing a dose-response pattern (all p for trend <0.01). Compared to the minimal activity group, which engaged in <5 MET-hours per week of PA, the odds ratios for moderate to severe LUTS were 0.83 (95% confidence interval [CI]: 0.72–0.97) for men engaging in 15–30 MET-hours per week, 0.82 (95% CI: 0.71–0.95) for 30–60 MET-hours per week, and 0.72 (95% CI: 0.62–0.84) for ≥60 MET-hours per week. The possible protective effect of PA was still observed in the additional analysis for voiding and storage symptoms showing the same dose-response pattern (all p for trend <0.01).
Conclusions
A higher PA level was associated with a lower prevalence and severity of total, voiding, and storage LUTS in a dose-dependent manner in Korean men.
6.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
8.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
9.Clinicopathological Correlations of Neurodegenerative Diseases in the National Brain Biobank of Korea
Young Hee JUNG ; Jun Pyo KIM ; Hee Jin KIM ; Hyemin JANG ; Hyun Jeong HAN ; Young Ho KOH ; Duk L. NA ; Yeon-Lim SUH ; Gi Yeong HUH ; Jae-Kyung WON ; Seong-Ik KIM ; Ji-Young CHOI ; Sang Won SEO ; Sung-Hye PARK ; Eun-Joo KIM
Journal of Clinical Neurology 2025;21(3):190-200
Background:
and Purpose The National Brain Biobank of Korea (NBBK) is a brain bank consortium supported by the Korea Disease Control and Prevention Agency and the Korea National Institute of Health, and was launched in 2015 to support research into neurodegenerative disease dementia (NDD). This study aimed to introduce the NBBK and describes clinicopathological correlations based on analyses of data collected from the NBBK.
Methods:
Four hospital-based brain banks have been established in South Korea: Samsung Medical Center Brain Bank (SMCBB), Seoul National University Hospital Brain Bank (SNUHBB), Pusan National University Hospital Brain Bank (PNUHBB), and Myongji Hospital Brain Bank (MJHBB). Clinical and pathological data were collected from these brain banks using standardized protocols. The prevalence rates of clinical and pathological diagnoses were analyzed in order to characterize the clinicopathological correlations.
Results:
Between August 2016 and December 2023, 185 brain specimens were collected and pathologically evaluated (SNUHBB: 117; PNUHBB: 27; SMCBB: 34; MJHBB: 7). The age at consent was 70.8±12.6 years, and the age at autopsy was 71.7±12.4 years. The four-most-common clinical diagnoses were Alzheimer’s disease (AD) dementia (20.0%), idiopathic Parkinson’s disease (15.1%), unspecified dementia (11.9%), and cognitively unimpaired (CU) (11.4%).Most cases of unspecified dementia had a pathological diagnosis of central nervous system (CNS) vasculopathy (31.8%) or AD (31.8%). Remarkably, only 14.2% of CU cases had normal pathological findings. The three-most-common pathological diagnoses were AD (26.5%), CNS vasculopathy (14.1%), and Lewy body disease (13.5%).
Conclusions
These clinical and neuropathological findings provide a deeper understanding of the mechanisms underlying NDD in South Korea.
10.Erratum: Korean Gastric Cancer Association-Led Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ;
Journal of Gastric Cancer 2025;25(2):400-402

Result Analysis
Print
Save
E-mail