1.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
2.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
3.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
4.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
5.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
6.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
7.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
8.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
9.The association between the severity of erectile dysfunction and left ventricular diastolic dysfunction in patients with and without cardiovascular disease
Chang Wan HYUN ; Jae Young HWANG ; Seong Woo YUN ; Tae Young PARK ; Sung Goo YOON ; Seung Bin KIM ; Tae Il NOH ; Sung Gu KANG ; Seok Ho KANG ; Dong-Hyuk CHO ; Ji Sung SHIM
Investigative and Clinical Urology 2024;65(2):165-172
Purpose:
Erectile dysfunction (ED) is considered a microvascular disorder and serves as an indicator for the potential development of cardiovascular disease (CVD). Although left ventricular diastolic dysfunction (LVDD) reflects early myocardial damage caused by microvascular disorders, the association between ED and LVDD remains poorly elucidated.
Materials and Methods:
A cross-sectional study was conducted on 123 patients with ED. They underwent RigiScan, and conventional echocardiography, and attempted International Index of Erectile Function (IIEF) questionnaire. ED severity was evaluated by measuring changes in the penile base circumference and duration of penile rigidity (≥70%) during erection. The early diastolic velocity of mitral inflow (E) and early diastolic velocity of the mitral annulus (e′) were measured using echocardiography. The patients were grouped based on the presence of CVD.
Results:
Among 123 patients, 29 had CVD and 94 did not. Patients with CVD exhibited more pronounced ED and more severe LVDD. Associations between increased penile circumference with echocardiographic parameters were more prominent in patients with CVD than in those without CVD (ΔTtop and e′ wave, r=0.508 and r=0.282, respectively, p for interaction=0.033; ΔTbase and E/e′ ratio, r=-0.338 and r=-0.293, respectively, p for interaction <0.001). In the multivariate linear regression, the increase of penile base circumference was an independent risk factor for LVDD (e′, B=0.503; E/e′ ratio, B=-1.416, respectively, p<0.001).
Conclusions
ED severity correlated well with LV diastolic dysfunction, particularly in the presence of CVD. This study highlighted the potential role of ED assessment as early indicator of CVD development.
10.Rebamipide Prevents the Hemoglobin Drop Related to MucosalDamaging Agents at a Level Comparable to Proton Pump Inhibitors
Ji Eun KIM ; Yeong Chan LEE ; Tae Se KIM ; Eun Ran KIM ; Sung Noh HONG ; Young-Ho KIM ; Kyunga KIM ; Dong Kyung CHANG
Gut and Liver 2024;18(6):1026-1036
Background/Aims:
The effect of proton pump inhibitors (PPIs) on the lower gastrointestinal (GI) tract is uncertain, with potential to worsen damage. This study aimed to find the best method for protecting the entire GI tract from mucosal damage.
Methods:
A retrospective cohort study at Samsung Medical Center (2002-2019) included 195,817 patients prescribed GI mucosa-damaging agents. The primary goal was to assess the effectiveness of GI protective agents in preventing significant hemoglobin drops (>2 g/dL), indicating overall GI mucosal damage. Self-controlled case series and landmark analysis were used to address biases in real-world data.
Results:
The incidence rate ratios for rebamipide, PPI, and histamine-2 receptor antagonist (H2RA) were 0.34, 0.33, and 0.52, respectively. Rebamipide showed a significantly lower incidence rate than H2RA and was comparable to PPIs. Landmark analysis revealed significant reductions in hemoglobin drop risk with rebamipide and H2RA, but not with PPI.
Conclusions
Rebamipide, like PPIs, was highly effective in preventing blood hemoglobin level decreases, as shown in real-world data. Rebamipide could be a comprehensive strategy for protecting the entire GI tract, especially when considering PPIs' potential side effects on the lower GI tract.

Result Analysis
Print
Save
E-mail