1.Key factors for successful eruption of the mandibular third molar after extraction of the mandibular second molar
Jung Jin PARK ; Yoonjeong NOH ; Yoon Jeong CHOI ; Jae Hyun PARK ; Ji Hyun LEE ; Chooryung Judi CHUNG ; Kyung-Ho KIM
The Korean Journal of Orthodontics 2025;55(2):154-163
Objective:
Extraction of the mandibular second molar (L7) and substitution by the mandibular third molar (L8) is an effective treatment option. This study aimed to evaluate spontaneously erupted L8 occlusion after L7 extraction, and identify the influencing factors.
Methods:
This study assessed 46 L8 from 28 patients using dental study models, panoramic radiographs, and lateral cephalograms obtained during L7 extraction (T1) and completion of L8 eruption (T2). At T2, samples were categorized as acceptable (A-group) or unacceptable (U-group) based on the American Board of Orthodontics index.L8 angulation and position, retromolar space, distance between the Xi point and mandibular first molar (L6), and Nolla stage were compared between the groups to identify the predictive factors for successful eruption.
Results:
At T2, 58.7% of L8 exhibited acceptable occlusion. Age at T1 was significantly higher in the U-group than that in the A-group. Angles ∠6-MnP and ∠8-MnP differed significantly between the groups at T2. Xi-L6 distance was considerably longer in the A-group than that in the U-group at T1 and T2. Younger age at extraction and Xi-L6 distance at T1 affected the acceptable occlusion.
Conclusions
Younger age at L7 extraction and adequate eruption space (Xi-L6 distance) appear to be the key factors for achieving acceptable L8 occlusion.
2.Preliminary study on change in the upper airway dimension in growing patients with Pierre-Robin sequence
Su-Ji YOON ; Il-Hyung YANG ; Su-Jung KIM ; Seung-Hak BAEK
The Korean Journal of Orthodontics 2025;55(2):105-119
Objective:
This study aimed to evaluate the changes in upper airway (UA) dimensions in growing patients with Pierre-Robin sequence (PRS).
Methods:
The subjects were 23 PRS patients who had not undergone growth modification therapy or surgical intervention. Their lateral cephalograms were obtained longitudinally at mean ages of 8.81 (T0) and 14.05 (T1). Patients were categorized based on their SNB value at T0 (Criteria: –2 SD): Group-1 (very retrusive mandible, n = 13) and Group-2 (moderately retrusive mandible, n = 10). Skeletal and UA variables at T0 and T1, as well as ∆T0-T1, were statistically analyzed.
Results:
At T0, Group-1 exhibited more retrusive maxilla and mandible (SNA, P < 0.01; SNB, P < 0.001), a more hyperdivergent pattern (facial height ratio, P < 0.05), and a more posteriorly positioned hyoid bone (H-PTV, P < 0.05), while Group-1 showed larger UA spaces (superior pharyngeal airway space [SPAS] and inferior pharyngeal airway space, all P < 0.05) than Group 2, which might indicate the existence of a compensatory response to maintain the UA patency.At T1, Group-1 maintained significantly retrusive maxilla and mandible (SNA and SNB, all P < 0.01), exhibited a less anteriorly positioned tongue (TT-PTV, P < 0.05), and displayed a more obtuse soft palate angle (SPA, P < 0.05) than Group-2.Between T0 and T1, Group-1 demonstrated significant increases in the hyoid symphysis distance (∆H-RGN, P < 0.001), tongue length (∆TGL, P < 0.01), and pharyngeal UA spaces (∆SPAS and ∆PNS-ad2, all P < 0.001).
Conclusions
Even in growing PRS patients with severe mandibular retrusion, the UA dimensions increased due to forward growth of the mandible, repositioning of tongue and hyoid bone, and existence of compensatory mechanism.
3.Comparison of Finasteride and Dutasteride on Risk of Prostate Cancer in Patients with Benign Prostatic Hyperplasia: A Pooled Analysis of 15Real-world Databases
Dae Yul YANG ; Won-Woo SEO ; Rae Woong PARK ; Sang Youl RHEE ; Jae Myung CHA ; Yoon Soo HAH ; Chang Won JEONG ; Kyung-Jin KIM ; Hyeon-Jong YANG ; Do Kyung KIM ; Ji Yong HA
The World Journal of Men's Health 2025;43(1):188-196
Purpose:
Finasteride and dutasteride are used to treat benign prostatic hyperplasia (BPH) and reduce the risk of developing prostate cancer. Finasteride blocks only the type 2 form of 5-alpha-reductase, whereas dutasteride blocks both type 1 and 2 forms of the enzyme. Previous studies suggest the possibility that dutasteride may be superior to finasteride in preventing prostate cancer. We directly compared the effects of finasteride and dutasteride on the risk of prostate cancer in patients with BPH using a pooled analysis of 15 real-world databases.
Materials and Methods:
We conducted a multicenter, cohort study of new-users of finasteride and dutasteride. We include patients who were prescribed 5 mg finasteride or dutasteride for the first time to treat BPH and had at least 180 days of prescription. We excluded patients with a history of prostate cancer or a prostate-specific antigen level ≥ 4 ng/mL before the study drug prescription. Cox regression analysis was performed to examine the hazard ratio (HR) for prostate cancer after propensity score (PS) matching.
Results:
A total of 8,284 patients of new-users of finasteride and 8,670 patients of new-users of dutasteride were included across the 15 databases. In the overall population, compared to dutasteride, finasteride was associated with a lower risk of prostate cancer in both on-treatment and intent-to-treat time-at-risk periods. After 1:1 PS matching, 4,897 patients using finasteride and 4,897 patients using dutasteride were enrolled in the present study. No significant differences were observed for risk of prostate cancer between finasteride and dutasteride both on-treatment (HR=0.66, 95% confidence interval [CI]: 0.44–1.00; p=0.051) and intent-to-treat time-at-risk periods (HR=0.87, 95% CI: 0.67–1.14; p=0.310).
Conclusions
Using real-world databases, the present study demonstrated that dutasteride was not associated with a lower risk of prostate cancer than finasteride in patients with BPH.
4.The Application of L-Serine-Incorporated Gelatin Sponge into the Calvarial Defect of the Ovariectomized Rats
Yoon-Jo LEE ; Ji-Hyeon OH ; Suyeon PARK ; Jongho CHOI ; Min-Ho HONG ; HaeYong KWEON ; Weon-Sik CHAE ; Xiangguo CHE ; Je-Yong CHOI ; Seong-Gon KIM
Tissue Engineering and Regenerative Medicine 2025;22(1):91-104
BACKGROUND:
Osteoporosis, characterized by decreased bone mineral density due to an imbalance between osteoblast and osteoclast activity, poses significant challenges in bone healing, particularly in postmenopausal women. Current treatments, such as bisphosphonates, are effective but associated with adverse effects like medication-related osteonecrosis of the jaw, necessitating safer alternatives.
METHODS:
This study investigated the use of L-serine-incorporated gelatin sponges for bone regeneration in calvarial defects in an ovariectomized rat model of osteoporosis. Thirty rats were divided into three groups: a control group, a group treated with a gelatin sponge containing an amino acid mixture, and a group treated with a gelatin sponge containing L-serine. Bone regeneration was assessed using micro-computed tomography (micro-CT) and histological analyses.
RESULTS:
The L-serine group showed a significant increase in bone volume (BV) and bone area compared to the control and amino acid groups. The bone volume to total volume (BV/TV) ratio was also significantly higher in the L-serine group.Immunohistochemical analysis demonstrated that L-serine treatment suppressed the expression of cathepsin K, a marker of osteoclast activity, while increasing serine racemase activity.
CONCLUSION
These findings suggest that L-serine-incorporated gelatin sponges not only enhance bone formation but also inhibit osteoclast-mediated bone resorption, providing a promising and safer alternative to current therapies for osteoporosis-related bone defects. Further research is needed to explore its clinical applications in human patients.
5.Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
Hee Jun PARK ; Hyo Jeong KANG ; So Yeon KIM ; Seonghun YOON ; Seunghee BAEK ; In Hye SONG ; Hyeon Ji JANG ; Jong Keon JANG
Ultrasonography 2025;44(1):83-91
Purpose:
This study assessed the impact of hepatic fibrosis on the diagnostic performance of the controlled attenuation parameter (CAP) in quantifying hepatic steatosis in patients with chronic hepatitis B (CHB).
Methods:
CHB patients who underwent liver stiffness measurement (LSM) and CAP assessment using transient elastography before liver resection between 2019 and 2022 were retrospectively evaluated. Clinical data included body mass index (BMI) and laboratory parameters. The histologically determined hepatic fat fraction (HFF) and fibrosis stages were reviewed by pathologists blinded to clinical and radiologic data. The Pearson correlation coefficient between CAP and HFF was calculated. The diagnostic performance of CAP for significant hepatic steatosis (HFF ≥10%) was assessed using areas under the receiver operating curve (AUCs), stratified by fibrosis stages (F0-1 vs. F2-4). Factors significantly associated with CAP were determined by univariable and multivariable linear regression analyses.
Results:
Among 399 CHB patients (median age 59 years; 306 men), 16.3% showed significant steatosis. HFF ranged from 0% to 60%. Of these patients, 9.8%, 19.8%, 29.3%, and 41.1% had fibrosis stages F0-1, F2, F3, and F4, respectively. CAP positively correlated with HFF (r=0.445, P<0.001). The AUC of CAP for diagnosing significant steatosis was 0.786 (95% confidence interval [CI], 0.726 to 0.845) overall, and significantly lower in F2-4 (0.772; 95% CI, 0.708 to 0.836) than in F0-1 (0.924; 95% CI, 0.835 to 1.000) (P=0.006). Multivariable analysis showed that BMI (P<0.001) and HFF (P<0.001) significantly affected CAP, whereas LSM and fibrosis stages did not.
Conclusion
CAP evaluations of significant hepatic steatosis are less reliable in CHB patients with significant or more advanced (F2-4) than with no or mild (F0-1) fibrosis.
6.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
7.Artificial Intelligence-Based Early Prediction of Acute Respiratory Failure in the Emergency Department Using Biosignal and Clinical Data
Changho HAN ; Yun Jung JUNG ; Ji Eun PARK ; Wou Young CHUNG ; Dukyong YOON
Yonsei Medical Journal 2025;66(2):121-130
Purpose:
Early identification of patients at risk for acute respiratory failure (ARF) could help clinicians devise preventive strategies. Analyzing biosignals with artificial intelligence (AI) can uncover hidden information and variability within time series. We aimed to develop and validate AI models to predict ARF within 72 h after emergency department admission, primarily using highresolution biosignals collected within 4 h of arrival.
Materials and Methods:
Our AI model, built on convolutional recurrent neural networks, combines biosignal feature extraction and sequence modeling. The model was developed and internally validated with data from 5284 admissions [1085 (20.5%) positive for ARF], and externally validated using data from 144 admissions [7 (4.9%) positive for ARF] from another institution. We defined ARF as the application of advanced respiratory support devices.
Results:
Our AI model performed well in predicting ARF, achieving area under the receiver operating characteristic curve (AUROC) of 0.840 and 0.743 in internal and external validations, respectively. It outperformed the Modified Early Warning Score (MEWS) and XGBoost models built only with clinical variables. High predictive ability for mortality was observed, with AUROC up to 0.809. A 10% increase in AI prediction scores was associated with 1.44-fold and 1.42-fold increases in ARF risk and mortality risk, respectively, even after adjusting for MEWS and demographic variables.
Conclusion
Our AI model demonstrates high predictive accuracy and significant associations with clinical outcomes. Our AI model has the potential to promptly aid in triage decisions. Our study shows that using AI to analyze biosignals advances disease detection and prediction.
8.Hepatocellular carcinoma in Korea: an analysis of the 2016-2018 Korean Nationwide Cancer Registry
Jihyun AN ; Young CHANG ; Gwang Hyeon CHOI ; Won SOHN ; Jeong Eun SONG ; Hyunjae SHIN ; Jae Hyun YOON ; Jun Sik YOON ; Hye Young JANG ; Eun Ju CHO ; Ji Won HAN ; Suk Kyun HONG ; Ju-Yeon CHO ; Kyu-Won JUNG ; Eun Hye PARK ; Eunyang KIM ; Bo Hyun KIM
Journal of Liver Cancer 2025;25(1):109-122
Background:
s/Aims: Hepatocellular carcinoma (HCC) is the sixth most common cancer and second leading cause of cancer-related deaths in South Korea. This study evaluated the characteristics of Korean patients newly diagnosed with HCC in 2016-2018.
Methods:
Data from the Korean Primary Liver Cancer Registry (KPLCR), a representative database of patients newly diagnosed with HCC in South Korea, were analyzed. This study investigated 4,462 patients with HCC registered in the KPLCR in 2016-2018.
Results:
The median patient age was 63 years (interquartile range, 55-72). 79.7% of patients were male. Hepatitis B infection was the most common underlying liver disease (54.5%). The Barcelona Clinic Liver Cancer (BCLC) staging system classified patients as follows: stage 0 (14.9%), A (28.8%), B (7.5%), C (39.0%), and D (9.8%). The median overall survival was 3.72 years (95% confidence interval, 3.47-4.14), with 1-, 3-, and 5-year overall survival rates of 71.3%, 54.1%, and 44.3%, respectively. In 2016-2018, there was a significant shift toward BCLC stage 0-A and Child-Turcotte-Pugh liver function class A (P<0.05), although survival rates did not differ by diagnosis year. In the treatment group (n=4,389), the most common initial treatments were transarterial therapy (31.7%), surgical resection (24.9%), best supportive care (18.9%), and local ablation therapy (10.5%).
Conclusions
Between 2016 and 2018, HCC tended to be diagnosed at earlier stages, with better liver function in later years. However, since approximately half of the patients remained diagnosed at an advanced stage, more rigorous and optimized HCC screening strategies should be implemented.
9.Sleep Tracking of Two Smartwatches Against Self-Reported Logs for Circadian Rhythm and Sleep Quality Assessment in Healthy Adults
Ji-Eun PARK ; Jayeun KIM ; Hoseok KIM ; Eunkyoung AHN ; Kyuhyun YOON
Journal of Sleep Medicine 2025;22(1):8-16
Although many wearable devices are used to assess sleep, their accuracy remains controversial. This study aimed to investigate the accuracy of the Actiwatch, a research-grade device, and the Fitbit, a consumer-grade device, against sleep diaries to assess sleep patterns. Methods: Twenty participants wore Fitbit and Actiwatch for two weeks and tracked their sleep patterns using sleep diaries. Total sleep time (TST), time-in-bed (TIB), sleep efficiency (SE), sleep onset latency (SOL), and wake after sleep onset (WASO) from the two devices and sleep diaries were analyzed using analysis of variance and Bland-Altman analysis. Results: The TIB measured by the sleep log, Fitbit, and Actiwatch were 420.9 minutes, 417.3 minutes, and 567.4 minutes, respectively. Compared to the sleep log, the Fitbit underestimated TST, TIB, and SE, with significant differences observed for TST (p<0.001) and SE (p<0.001), but not for TIB. The Actiwatch overestimated TIB (p<0.001) and TST (p=0.02) and underestimated SE (p<0.001) compared to the sleep log. The difference between the Fitbit and Actiwatch was significant for TST, TIB, and SE (all p<0.001). Conclusions: The Fitbit showed a smaller difference than the Actiwatch when compared with the sleep logs. The Fitbit could be used as a tool to assess sleep patterns in the clinic as well as in daily life.
10.Association between Skeletal Muscle Mass and Ocular Perfusion Pressure in Glaucoma
Jisoo KANG ; Ji Hong KIM ; Yu Jeong KIM ; Han Woong LIM ; Jooyoung YOON ; Won June LEE
Korean Journal of Ophthalmology 2025;39(3):246-260
Purpose:
This study aimed to investigate the relationship between body composition and glaucoma by analyzing the associations between anthropometric and ocular parameters.
Methods:
A total of 494 eyes from 247 patients were reviewed from a general health examination database at a tertiary hospital. Anthropometric parameters were assessed using a multifrequency bioelectrical impedance device. Mean ocular perfusion pressure (MOPP) was calculated based on systolic and diastolic blood pressures and intraocular pressure (IOP). Retinal thickness and other ocular parameters were analyzed for their association with body composition.
Results:
A total of 221 eyes from 221 patients, including 104 with glaucoma, were enrolled in the final analysis. The prevalence of sarcopenia was significantly higher in patients with glaucomatous damage than in those without (p = 0.025). Higher IOP showed significant associations with lower MOPP (p < 0.001), higher body mass index (BMI; p = 0.001), and higher waist to hip ratio (p = 0.001). Retinal thickness was not significantly associated with body composition parameters, including BMI and appendicular lean mass adjusted with squared height. Higher MOPP was significantly correlated with lower IOP (p < 0.001), higher BMI (p < 0.001), higher waist to hip ratio (p < 0.001), and higher appendicular lean mass divided by squared height (p = 0.009).
Conclusions
Skeletal muscle mass and BMI were significantly associated with MOPP. Since low MOPP is a known risk factor for glaucoma, its association with skeletal muscle mass may indicate a relationship between systemic muscle health, ocular blood perfusion, and glaucomatous damage. Further large-scale studies are needed to validate these associations between skeletal muscle mass and glaucoma and explore their clinical implications.

Result Analysis
Print
Save
E-mail