1.Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
Hee Jun PARK ; Hyo Jeong KANG ; So Yeon KIM ; Seonghun YOON ; Seunghee BAEK ; In Hye SONG ; Hyeon Ji JANG ; Jong Keon JANG
Ultrasonography 2025;44(1):83-91
Purpose:
This study assessed the impact of hepatic fibrosis on the diagnostic performance of the controlled attenuation parameter (CAP) in quantifying hepatic steatosis in patients with chronic hepatitis B (CHB).
Methods:
CHB patients who underwent liver stiffness measurement (LSM) and CAP assessment using transient elastography before liver resection between 2019 and 2022 were retrospectively evaluated. Clinical data included body mass index (BMI) and laboratory parameters. The histologically determined hepatic fat fraction (HFF) and fibrosis stages were reviewed by pathologists blinded to clinical and radiologic data. The Pearson correlation coefficient between CAP and HFF was calculated. The diagnostic performance of CAP for significant hepatic steatosis (HFF ≥10%) was assessed using areas under the receiver operating curve (AUCs), stratified by fibrosis stages (F0-1 vs. F2-4). Factors significantly associated with CAP were determined by univariable and multivariable linear regression analyses.
Results:
Among 399 CHB patients (median age 59 years; 306 men), 16.3% showed significant steatosis. HFF ranged from 0% to 60%. Of these patients, 9.8%, 19.8%, 29.3%, and 41.1% had fibrosis stages F0-1, F2, F3, and F4, respectively. CAP positively correlated with HFF (r=0.445, P<0.001). The AUC of CAP for diagnosing significant steatosis was 0.786 (95% confidence interval [CI], 0.726 to 0.845) overall, and significantly lower in F2-4 (0.772; 95% CI, 0.708 to 0.836) than in F0-1 (0.924; 95% CI, 0.835 to 1.000) (P=0.006). Multivariable analysis showed that BMI (P<0.001) and HFF (P<0.001) significantly affected CAP, whereas LSM and fibrosis stages did not.
Conclusion
CAP evaluations of significant hepatic steatosis are less reliable in CHB patients with significant or more advanced (F2-4) than with no or mild (F0-1) fibrosis.
2.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
3.Hepatocellular carcinoma in Korea: an analysis of the 2016-2018 Korean Nationwide Cancer Registry
Jihyun AN ; Young CHANG ; Gwang Hyeon CHOI ; Won SOHN ; Jeong Eun SONG ; Hyunjae SHIN ; Jae Hyun YOON ; Jun Sik YOON ; Hye Young JANG ; Eun Ju CHO ; Ji Won HAN ; Suk Kyun HONG ; Ju-Yeon CHO ; Kyu-Won JUNG ; Eun Hye PARK ; Eunyang KIM ; Bo Hyun KIM
Journal of Liver Cancer 2025;25(1):109-122
Background:
s/Aims: Hepatocellular carcinoma (HCC) is the sixth most common cancer and second leading cause of cancer-related deaths in South Korea. This study evaluated the characteristics of Korean patients newly diagnosed with HCC in 2016-2018.
Methods:
Data from the Korean Primary Liver Cancer Registry (KPLCR), a representative database of patients newly diagnosed with HCC in South Korea, were analyzed. This study investigated 4,462 patients with HCC registered in the KPLCR in 2016-2018.
Results:
The median patient age was 63 years (interquartile range, 55-72). 79.7% of patients were male. Hepatitis B infection was the most common underlying liver disease (54.5%). The Barcelona Clinic Liver Cancer (BCLC) staging system classified patients as follows: stage 0 (14.9%), A (28.8%), B (7.5%), C (39.0%), and D (9.8%). The median overall survival was 3.72 years (95% confidence interval, 3.47-4.14), with 1-, 3-, and 5-year overall survival rates of 71.3%, 54.1%, and 44.3%, respectively. In 2016-2018, there was a significant shift toward BCLC stage 0-A and Child-Turcotte-Pugh liver function class A (P<0.05), although survival rates did not differ by diagnosis year. In the treatment group (n=4,389), the most common initial treatments were transarterial therapy (31.7%), surgical resection (24.9%), best supportive care (18.9%), and local ablation therapy (10.5%).
Conclusions
Between 2016 and 2018, HCC tended to be diagnosed at earlier stages, with better liver function in later years. However, since approximately half of the patients remained diagnosed at an advanced stage, more rigorous and optimized HCC screening strategies should be implemented.
4.Predicting Mortality and Cirrhosis-Related Complications with MELD3.0: A Multicenter Cohort Analysis
Jihye LIM ; Ji Hoon KIM ; Ahlim LEE ; Ji Won HAN ; Soon Kyu LEE ; Hyun YANG ; Heechul NAM ; Hae Lim LEE ; Do Seon SONG ; Sung Won LEE ; Hee Yeon KIM ; Jung Hyun KWON ; Chang Wook KIM ; U Im CHANG ; Soon Woo NAM ; Seok-Hwan KIM ; Pil Soo SUNG ; Jeong Won JANG ; Si Hyun BAE ; Jong Young CHOI ; Seung Kew YOON ; Myeong Jun SONG
Gut and Liver 2025;19(3):427-437
Background/Aims:
This study aimed to evaluate the performance of the Model for End-Stage Liver Disease (MELD) 3.0 for predicting mortality and liver-related complications compared with the Child-Pugh classification, albumin-bilirubin (ALBI) grade, the MELD, and the MELD sodium (MELDNa) score.
Methods:
We evaluated a multicenter retrospective cohort of incorporated patients with cirrhosis between 2013 and 2019. We conducted comparisons of the area under the receiver operating characteristic curve (AUROC) of the MELD3.0 and other models for predicting 3-month mortality. Additionally, we assessed the risk of cirrhosis-related complications according to the MELD3.0 score.
Results:
A total of 3,314 patients were included. The mean age was 55.9±11.3 years, and 70.2% of the patients were male. Within the initial 3 months, 220 patients (6.6%) died, and the MELD3.0had the best predictive performance among the tested models, with an AUROC of 0.851, outperforming the Child-Pugh classification, ALBI grade, MELD, and MELDNa. A high MELD3.0score was associated with an increased risk of mortality. Compared with that of the group with a MELD3.0 score <10 points, the adjusted hazard ratio of the group with a score of 10–20 pointswas 2.176, and that for the group with a score of ≥20 points was 4.892. Each 1-point increase inthe MELD3.0 score increased the risk of cirrhosis-related complications by 1.033-fold. The risk of hepatorenal syndrome showed the highest increase, with an adjusted hazard ratio of 1.149, followed by hepatic encephalopathy and ascites.
Conclusions
The MELD3.0 demonstrated robust prognostic performance in predicting mortality in patients with cirrhosis. Moreover, the MELD3.0 score was linked to cirrhosis-related complications, particularly those involving kidney function, such as hepatorenal syndrome and ascites.
5.Incidentally detected bilateral sub-internal limiting membrane hemorrhages in typical hemolytic uremic syndrome: a case report
Childhood Kidney Diseases 2025;29(1):32-38
We present an incidentally detected case of bilateral sub-internal limiting membrane (ILM) hemorrhage secondary to typical hemolytic uremic syndrome (HUS) along with a literature review. A 4-year-old girl presented to our emergency department with bloody diarrhea, abdominal pain, fever, and oliguria. HUS was suspected based on clinical symptoms and laboratory findings suggestive of hemolytic anemia, thrombocytopenia, and acute kidney injury. Supportive management, including intermittent dialysis, was provided during admission. However, the patient exhibited central nervous system involvement and presented with a seizure. Despite the absence of visual symptoms, a fundus examination revealed unexpected bilateral sub-ILM hemorrhages and a cotton wool spot in the right eye. Blood dyscrasia improved with repeated hemodialysis and red blood cell transfusions. The sub-ILM hemorrhage gradually resolved, as observed on consecutive fundus photographs. Multimodal retinal imaging revealed healthy capillary structures without evidence of macular ischemia or fibrosis. Typical HUS can be accompanied by a sub-ILM hemorrhage without preceding symptoms. The absence of visual symptoms, despite significant retinal abnormalities, emphasizes the importance of immediate and routine fundus examinations in patients with typical HUS. This proactive approach improves early detection of ocular involvement, enabling prompt intervention to manage potential visual complications, and ultimately improving patient outcomes.
6.Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
Hee Jun PARK ; Hyo Jeong KANG ; So Yeon KIM ; Seonghun YOON ; Seunghee BAEK ; In Hye SONG ; Hyeon Ji JANG ; Jong Keon JANG
Ultrasonography 2025;44(1):83-91
Purpose:
This study assessed the impact of hepatic fibrosis on the diagnostic performance of the controlled attenuation parameter (CAP) in quantifying hepatic steatosis in patients with chronic hepatitis B (CHB).
Methods:
CHB patients who underwent liver stiffness measurement (LSM) and CAP assessment using transient elastography before liver resection between 2019 and 2022 were retrospectively evaluated. Clinical data included body mass index (BMI) and laboratory parameters. The histologically determined hepatic fat fraction (HFF) and fibrosis stages were reviewed by pathologists blinded to clinical and radiologic data. The Pearson correlation coefficient between CAP and HFF was calculated. The diagnostic performance of CAP for significant hepatic steatosis (HFF ≥10%) was assessed using areas under the receiver operating curve (AUCs), stratified by fibrosis stages (F0-1 vs. F2-4). Factors significantly associated with CAP were determined by univariable and multivariable linear regression analyses.
Results:
Among 399 CHB patients (median age 59 years; 306 men), 16.3% showed significant steatosis. HFF ranged from 0% to 60%. Of these patients, 9.8%, 19.8%, 29.3%, and 41.1% had fibrosis stages F0-1, F2, F3, and F4, respectively. CAP positively correlated with HFF (r=0.445, P<0.001). The AUC of CAP for diagnosing significant steatosis was 0.786 (95% confidence interval [CI], 0.726 to 0.845) overall, and significantly lower in F2-4 (0.772; 95% CI, 0.708 to 0.836) than in F0-1 (0.924; 95% CI, 0.835 to 1.000) (P=0.006). Multivariable analysis showed that BMI (P<0.001) and HFF (P<0.001) significantly affected CAP, whereas LSM and fibrosis stages did not.
Conclusion
CAP evaluations of significant hepatic steatosis are less reliable in CHB patients with significant or more advanced (F2-4) than with no or mild (F0-1) fibrosis.
7.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
8.Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
Hee Jun PARK ; Hyo Jeong KANG ; So Yeon KIM ; Seonghun YOON ; Seunghee BAEK ; In Hye SONG ; Hyeon Ji JANG ; Jong Keon JANG
Ultrasonography 2025;44(1):83-91
Purpose:
This study assessed the impact of hepatic fibrosis on the diagnostic performance of the controlled attenuation parameter (CAP) in quantifying hepatic steatosis in patients with chronic hepatitis B (CHB).
Methods:
CHB patients who underwent liver stiffness measurement (LSM) and CAP assessment using transient elastography before liver resection between 2019 and 2022 were retrospectively evaluated. Clinical data included body mass index (BMI) and laboratory parameters. The histologically determined hepatic fat fraction (HFF) and fibrosis stages were reviewed by pathologists blinded to clinical and radiologic data. The Pearson correlation coefficient between CAP and HFF was calculated. The diagnostic performance of CAP for significant hepatic steatosis (HFF ≥10%) was assessed using areas under the receiver operating curve (AUCs), stratified by fibrosis stages (F0-1 vs. F2-4). Factors significantly associated with CAP were determined by univariable and multivariable linear regression analyses.
Results:
Among 399 CHB patients (median age 59 years; 306 men), 16.3% showed significant steatosis. HFF ranged from 0% to 60%. Of these patients, 9.8%, 19.8%, 29.3%, and 41.1% had fibrosis stages F0-1, F2, F3, and F4, respectively. CAP positively correlated with HFF (r=0.445, P<0.001). The AUC of CAP for diagnosing significant steatosis was 0.786 (95% confidence interval [CI], 0.726 to 0.845) overall, and significantly lower in F2-4 (0.772; 95% CI, 0.708 to 0.836) than in F0-1 (0.924; 95% CI, 0.835 to 1.000) (P=0.006). Multivariable analysis showed that BMI (P<0.001) and HFF (P<0.001) significantly affected CAP, whereas LSM and fibrosis stages did not.
Conclusion
CAP evaluations of significant hepatic steatosis are less reliable in CHB patients with significant or more advanced (F2-4) than with no or mild (F0-1) fibrosis.
9.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
10.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.

Result Analysis
Print
Save
E-mail