1.Pre-operative risk assessment of hepatocellular carcinoma recurrence in liver transplant recipients by non-invasive detection of pre-existing genetic lesions
Suqin YANG ; Sunbin LING ; Jianhua LI ; Yan WANG ; Jiapei WANG ; Qiwei HUANG ; Fanming LIU ; Yiqi ZHUANG ; Yingyu ZHENG ; Rui WANG ; Zhe YANG ; Xiaoping ZHENG ; Kai WANG ; Zhikun LIU ; Jun CHEN ; Jianguo WANG ; Haiyang XIE ; Lin ZHOU ; Leiming CHEN ; Guoqiang CAO ; Dandan CHEN ; Junfang JI ; Bin ZHAO ; Chao JIANG ; Di LU ; Xuyong WEI ; Hangjin JIANG ; Qiaonan SHAN ; Hengbo SHI ; Yong-Zhen XU ; Shusen ZHENG ; Zhengxin WANG ; Shengda LIN ; Xiao XU
Clinical and Molecular Hepatology 2026;32(2):884-903
Background/Aims:
Liver transplantation (LT) following total hepatectomy is a life-saving treatment for hepatocellular carcinoma (HCC). The HCC recurrence after LT hinders the effectiveness of the procedure. The objective of this study is to develop a pre-operative risk stratification model based on a liquid biopsy.
Methods:
We conducted a comprehensive multi-omics study of 260 HCC patients from three centers, including clinical data, low-coverage whole-genome sequencing of cell-free DNA (cfDNA) from plasma, as well as whole-exome, single-nucleus RNA, and spatial transcriptomics from matched tumor and non-tumor tissues.
Results:
We identified cfDNA-derived copy number alteration (CNA) signatures associated with post-transplant recurrence. By integrating cfDNA-derived CNA profiles with single-cell transcriptomic data, we traced recurrence-associated cfDNA to a distinct subpopulation of malignant cells within the primary tumor. These cells were embedded in a pro-metastatic microenvironment of specialized endothelial subtypes and cancer-associated fibroblasts. Notably, most recurrence-associated lesions were detectable in cfDNA prior to liver transplantation (LT). Building on these insights, we developed the ZJU Criteria based on CNA fragments and tumor markers, a pre-LT risk prediction tool that integrates conventional clinical factors with cfDNA-derived CNA signatures, and validated it using internal and independent external cohorts.
Conclusion
Our findings suggest that post-transplant recurrence commonly originates from advanced subclones that emerge late during tumor evolution. The ZJU Criteria provides an accurate, non-invasive strategy that significantly improves pre-LT risk stratification and clinical decision-making for patients with HCC.
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.Analysis of polonium-210 activity concentration in seafood from eastern coastal areas of China and its dose assessment
Ziyuan HE ; Liangliang YIN ; Yuhan XIE ; Yanqin JI
Chinese Journal of Radiological Health 2026;35(3):349-353
Objective To establish an alpha spectrometric method for the analysis of polonium-210 (210Po) in seafood, determine the activity concentration of 210Po in seafood from China’s eastern coastal areas, and assess the corresponding radiation doses. Methods A total of 21 types of seafood belonging to four categories (fish, shrimp, crab, and shellfish) were collected from eastern coastal cities in China. The activity concentration of 210Po in different tissues of the seafood was analyzed using the 209Po tracer-α spectrometry method. The annual effective dose was then estimated by combining seafood consumption rates and dose conversion factors. Results The activity concentrations of 210Po in the edible parts of fish, shrimp, and shellfish samples ranged from 0.65 to 17.89 Bq/kg, 0.81 to 5.95 Bq/kg, and 0.73 to 44.09 Bq/kg, respectively. In whole crab samples, the range was 1.77 to 11.43 Bq/kg. The activity concentration of 210Po in crab samples (whole crab) ranged from 1.77 to 11.43 Bq/kg. 210Po activity was mainly enriched in the head, internal organs, and shell. The annual effective ingestion dose for different age groups ranged from 91.39 to 251.33 μSv/a. Conclusion The annual effective dose resulting from 210Po ingestion via seafood consumption for residents in China’s eastern coastal regions is lower than the annual effective dose reference level recommended by the IAEA.
4.Analysis of the Therapeutic Differences Among Different Treatment Regimens of Lung-Boosting Moxibustion for Stable Chronic Obstructive Pulmonary Disease
Jiaxin XU ; Zile JI ; Peng ZHANG ; Jianya YANG ; Yang XIE ; Suyun LI
Journal of Traditional Chinese Medicine 2026;67(17):1868-1876
ObjectiveTo observe the clinical efficacy and safety of lung-boosting moxibustion with different moxibustion doses in the treatment of stable chronic obstructive pulmonary disease (COPD). MethodsA total of 240 stable COPD patients with lung qi deficiency, lung-spleen qi deficiency, or lung-kidney qi deficiency syndrome were enrolled, all receiving standardized western medical treatment and lung-boosting moxibustion. According to the thickness of the moxa wool, the thickness of the ginger paste, and the treatment duration, patients were randomly divided into eight groups, which were Group A (3.0 cm thickness moxa, 2.5 cm ginger mud, 60 min treatment time), Group B (3.0 cm thickness moxa, 2.5 cm ginger mud, 90 min treatment time), Group C (2.0 cm thickness moxa, 2.5 cm ginger mud, 60 min treatment time), Group D (2.0 cm thickness moxa, 2.5 cm ginger mud, 90 min treatment time), Group E (3.0 cm thickness moxa, 2.0 cm ginger mud, 60 min treatment time), Group F (3.0 cm thickness moxa, 2.0 cm ginger mud, 90 min treatment time), Group G (2.0 cm thickness moxa, 2.0 cm ginger mud, 60 min treatment time), Group H (2.0cm thickness moxa, 2.0cm ginger mud, 90 min treatment time). Treatment was performed once every 15 days for 3 months, with a total of six sessions. The primary outcomes were the scores of the clinical symptoms and signs questionnaire for stable COPD before and after treatment, comprising seven symptom domains (cough, sputum production, wheezing, chest tightness, shortness of breath, fatigue, and cyanosis) and the total score. The secondary outcomes included the scores of the modified COPD patient-reported outcome questionnaire (mCOPD-PRO) involving the physical, psychological, and environmental domains and the total score, the scores of the modified Effectiveness Satisfaction Questionnaire for COPD (mESQ-COPD) involving clinical symptoms, work and daily living capacity, environmental adaptability, treatment efficacy, and the total score before and after treatment, the moxibustion sensation scores (heat sensation score and special sensation intensity score) during treatment, and cutaneous temperature (the maximum temperature achieved, the duration of temperature maintained at ≥43 ℃, and the time required to reach 43 ℃). The safety evaluation was carried out after treatment. ResultsDuring the study, 18 patients withdrew, and 222 patients were included in the per-protocol set for analysis, including 27 in Group A, 28 in Group B, 28 in Group C, 29 in Group D, 27 in Group E, 28 in Group F, 27 in Group G, and 28 in Group H. After treatment, the total score on the clinical symptoms and signs questionnaire, as well as the cough and chest tightness symptom scores in Group F were significantly lower than those in other groups (P<0.05). Group F demonstrated statistically lower total mCOPD-PRO score and physical domain score (P<0.05), lower total mESQ-COPD score and the scores for clinical symptoms and treatment efficacy (P < 0.05), as well as higher heat sensation score (P<0.05) than other groups. The maximum temperature was significantly higher in Group E and Group F than in the other groups, while the duration of temperature maintained at ≥43 ℃ was significantly longer in Group F than other groups, and the time required to reach 43 ℃ was significantly shorter in Group E and Group F than in Groups C, D, G, and H (P<0.05). No significant abnormalities were observed in routine blood tests, liver function, renal function, urinalysis, or electrocardiograms before and after treatment in any group. No serious adverse events occurred during the treatment period. ConclusionThere are differences in the efficacy of different moxibustion doses of lung-boosting moxibustion in the treatment of stable COPD. Moxibustion with 3.0 cm thickness moxa, 2.0 cm ginger mud, and 90 min treatment time can obtain relatively superior efficacy while demonstrating a favorable safety profile.
5.Distribution characteristics, source apportionment, and health risk assessment of metals and metalloids in PM2.5 in a southern city in 2019
Yaxin QU ; Suli HUANG ; Chao WANG ; Jie JIANG ; Jiajia JI ; Daokui FANG ; Shaohua XIE ; Xiaoheng LI ; Ning LIU
Journal of Environmental and Occupational Medicine 2025;42(2):196-204
Background Metals and metalloids in fine particulate matter (PM2.5) may cause damage to the respiratory and circulatory systems of the human body, and long-term exposure is prone to causing chronic poisoning, cancer, and other adverse effects. Objective To assess the distribution characteristics of metals and metalloids in outdoor PM2.5 in a southern city of China, conduct source apportionment, and evaluate the associated health risks, thereby providing theoretical support for further pollution control measures. Methods PM2.5 samples were collected in districts A, B, and C of a southern China city, and the concentrations of 17 metals and metalloids were detected by inductively coupled plasma-mass spectrometry (ICP-MS). Pollution sources were assessed through enrichment factor and principal components analysis, and the main pollution sources were quantified using absolute principal component scores-multivariate linear regression (APCS-MLR). Health risks were evaluated based on the Technical guide for environmental health risk assessment of chemical exposure (WS/T777—2021). Results The ambient air PM2.5 concentrations in the city were higher in winter and spring, and lower in summer and autumn. The annual average concentrations of ambient PM2.5 in districts A, B, and C were 36.7, 31.9, and 24.4 μg·m−3, respectively. The ambient PM2.5 levels in districts B and C were below the second-grade limit set by the Ambient air quality standards (GB 3095—2012). The enrichment factors of cadmium (Cd), aluminum (Al), and antimony (Sb) were greater than 10, those of copper (Cu), lead (Pb), arsenic (As), nickel (Ni), mercury (Hg), and molybdenum (Mo) fell between 1 and 10, and those of manganese (Mn), vanadium (V), chromium (Cr), cobalt (Co), barium (Ba), beryllium (Be), and uranium (U) were below or equal to 1. The comprehensive evaluation of source analysis showed that the main pollution sources in districts A and C and the whole city were coal-burning. In district B, the main pollution source was also coal combustion, followed by industrial process sources and dust sources. The carcinogenic risks of As and Cr were between 1×10−6 and 1×10−4. However, the hazard quotients for 15 metals and metalloids in terms of non-carcinogenic risk were below 1. Conclusion Cr and As in the atmospheric PM2.5 of the city present a certain risk of cancer and should be paid attention to. In addition, preventive control measures should be taken against relevant pollution sources such as industrial emission, dust, and coal burning.
6.Concept,Organizational Structure,and Medical Model of the Traditional Chinese Medicine Myocardial Infarction Unit
Jun LI ; Jialiang GAO ; Jie WANG ; Zhenpeng ZHANG ; Xinyuan WU ; Ji WU ; Zicong XIE ; Jingrun CUI ; Haoqiang HE ; Yuqing TAN ; Chunkun YANG
Journal of Traditional Chinese Medicine 2025;66(9):873-877
The traditional Chinese medicine (TCM) myocardial infarction (MI) unit is a standardized, regulated, and continuous integrated care unit guided by TCM theory and built upon existing chest pain centers or emergency care units. This unit emphasizes multidisciplinary collaboration and forms a restructured clinical entity without altering current departmental settings, offering comprehensive diagnostic and therapeutic services with full participation of TCM in the treatment of MI. Its core medical model is patient-centered and disease-focused, providing horizontally integrated TCM-based care across multiple specialties and vertically constructing a full-cycle treatment unit for MI, delivering prevention, treatment, and rehabilitation during the acute, stable, and recovery phases. Additionally, the unit establishes a TCM-featured education and prevention mechanism for MI to guide patients in proactive health management, reduce the incidence of myocardial infarction, and improve quality of life.
7.Analysis of detection of repeat blood donors with unqualified alanine aminotransferase
Zijian ZENG ; Fenfang LIAO ; Junmou XIE ; Zhiting WAN ; Rongsong DU ; Zhongping LI ; Haojian LIANG ; Shijie LI ; Yanli JI ; Huaqin LIANG ; Hao WANG
Chinese Journal of Blood Transfusion 2025;38(4):482-487
[Objective] To retrospectively analyze the detection results of alanine aminotransferase (ALT) unqualified repeat blood donors in Guangzhou, so as to provide evidence for further expanding the repeat blood donor pool, reducing the rate of blood discarding and improving the qualified rate of blood test. [Methods] Blood donors with unqualified ALT in Guangzhou Blood Center from January 2018 to April 2024 were selected as the research objects. The past blood donation and population characteristics were analyzed according to the number of blood donations and ALT unqualified times. [Results] Among repeat blood donors with previous ALT disqualification, 99.5% to 99.7% did not have reactive markers for transfusion-transmitted diseases (TTD), which was higher than the rate among first-time blood donors with unqualified ALT (95.8%) (P<0.05). The rate of single-item ALT disqualification in repeat blood donors was higher in males than in females (P<0.05); it also varied by age (18-25 years > 26-35 years > 36-45 years > over 45 years) (P<0.05); and by quarter (third and fourth quarters > first and second quarters) (P<0.05). The ALT unqualified rate was significantly higher whole blood donors than that of platelet donors and returning blood donors (P<0.05). The overall ALT level (51.0 U/L), individual ALT level (56.0 U/L) and individual ALT unqualified rate (66.7%) of repeat blood donors with multiple ALT disqualifications were higher than those of repeat blood donors with single-item ALT disqualifications (26.0 U/L, 38.5 U/L, and 33.3%, respectively) (P<0.05). Moreover, as the number of ALT disqualifications increased, the overall level of ALT in repeat blood donors also increased (P<0.05), and the average level of individual ALT and individual ALT unqualified ratio tended to increase. Repeat blood donors with frequent ALT disqualifications had higher ALT levels (69.0 U/L). [Conclusion] The ALT unqualified rates of repeat blood donors were mostly non-specific elevation without TTD. Repeat blood donors with multiple ALT disqualifications tend to have continuous high ALT. Moreover, and with the increase of ALT disqualifications times, the overall ALT levels the average individual ALT levels and individual ALT unqualified rates showed an increasing trend.
8.Application and optimization of HDEHP extraction chromatography in the determination of strontium-90 in seafood
Cen SHI ; Yuhan XIE ; Yuxin QIAN ; Yanqin JI
Chinese Journal of Radiological Health 2025;34(2):231-236
Objective To evaluate the environmental radioactive safety level in China, monitor the radioactivity of strontium-90 (90Sr) in seafood from selected marine regions of China, and optimize the di-(2-ethylhexyl)phosphoric acid (HDEHP) extraction chromatography method for determining Sr-90 in seafood. Methods In 2023, seafoods of fish, shrimp, shellfish, and seaweed were collected from the Shandong Province (Bohai Sea and Yellow Sea) and Hainan Province (South China Sea). The levels of Sr in the samples were determined by inductively coupled plasma atomic emission spectrometer (ICP-AES). The 90Sr separation were performed using HDEHP extraction chromatography, while the recovery of 90Sr were determined by the gravitmetry with the assistant of ICP-AES. Results The content of strontium in seafoods varies greatly, and excessive strontium and calcium in seafood may lead to overestimated recovery due to insufficient leaching during chromatographic separation by HDEHP extraction. Therefore, the yttrium content in the eluent should be analyzed by ICP . The radioactivity of 90Sr in seafood from the sea areas in Shandong Province was 0.22-1.85 Bq/kg (dry weight), and that of seafood from Hainan Province was 0.19-1.82 Bq/kg (dry weight). Conclusion For the analysis of shirmp and seaweed samples, the recovery rate of 90Sr should be analyzed using both gravimetry and ICP-AES. There is no significant linear correlation between total Sr and 90Sr in seafood. There is no significant difference in 90Sr radioactivity between the seafood samples collected from Shandong and Hainan. The 90Sr radioactivity levels of all 28 samples are below the limit specified in the Limited concentrations of radioactive materials in foods (GB 14882—1994) and are within the range of environmental background fluctuations.
9.Analysis of the 2023 national interlaboratory comparison for measurement of gross α and gross β radioactivity in water
Liangliang YIN ; Yuhan XIE ; Yuxin QIAN ; Cen SHI ; Yanqin JI
Chinese Journal of Radiological Health 2025;34(2):237-241
Objective To organize a nationwide interlaboratory comparison for measurement of gross α and gross β radioactivity in water, and improve the laboratory analysis of gross α and gross β radioactivity in water. Methods A unified comparison protocol was developed by the organizers. The groundwater with high natural radioactivity was used as water sample and distributed randomly to the participating laboratories. The participating laboratories used routine analytical methods to measure the samples and provided information such as analytical results, original records, and test reports. The results were evaluated using z-score. Results A total of 76 laboratories participated in the comparison, all employing the evaporation concentration-α/β counting method. Among them, 69 laboratories achieved |z| ≤ 2 for both gross α and gross β radioactivity measurements, and 32 laboratories achieved |z| ≤ 0.50 for both gross α and gross β radioactivity measurements. There were 69 laboratories with qualified results and 30 laboratories with excellent results, yielding a qualified rate of 90.8% and an excellent rate of 39.5%. Seven laboratories showed unqualified results and the unqualified rate was 9.2%. Conclusion Most laboratories have the ability to analyze gross α and gross β radioactivity in water. The main reasons for the deviation in comparison results are calibration efficiency, errors in the total residue mass caused by improper water sample processing operations. By analyzing the main technical problems existed in unqualified laboratories, their ability for measurement of gross α and gross β radioactivity in water has been improved.
10.Design of detection gloves for orthopedic manipulation
Liu-peng SHI ; Bin SHI ; Sheng-nan CAO ; Ji-qing WANG ; Liang-yu XIE ; Guo-dong SUN
Chinese Medical Equipment Journal 2025;46(7):27-33
Objective To design a pairs of detection gloves for orthopedic manipulation to solve the problems of orthopedic manipulation in accurate,visual and quantitative description and reproduction in teaching.Methods The orthopedic manipulation detection gloves were mainly composed of a detection body worn on the hands,a main control module and a data visualization system.The detection body was made of multi-layer flexible materials such as rubber,cotton and non-woven fabrics,which integrated inertial sensors,pressure sensors and a data acquisition device;the main control module consisted of a filter circuit,an A/D converter(MCP3008)and a main controller(ARM-STM32 microcontroller);the data visualization system was designed based on the Unity 3D platform.Results The orthopedic manipulation detection gloves effectively detected the rotation angle of the knuckle during the orthopedic process with a high accuracy rate.Conclusion The orthopedic manipulation detection gloves can quantitatively display the abstract orthopedic manipulation,and can provide support for intelligent orthopedic teaching and orthopedic manipulation optimization.[Chinese Medical Equipment Journal,2025,46(7):27-33]

Result Analysis
Print
Save
E-mail