1.Successful desensitization to contrast media in a patient with recurrent hypersensitivity to multiple iodinated contrast agents: A case report
Jeong Min PARK ; Sun Young PAIK ; Jiung JEONG ; Young-Chan KIM ; Heung-Woo PARK ; Sang-Heon CHO ; Hye-Ryun KANG ; Ji-Hyang LEE
Allergy, Asthma & Respiratory Disease 2026;14(2):97-100
Hypersensitivity reactions (HSRs) to iodinated contrast media (ICM) can range from mild cutaneous symptoms to life-threatening anaphylaxis. In patients with a history of ICM hypersensitivity, avoidance of the culprit agent is generally recommended. This case report describes a successful desensitization in a 56-year-old man with recurrent HSRs to multiple agents including ioversol, iohexol, iobitridol, and iopamidol. Intradermal testing was performed to identify potentially safe alternatives; however, all tested agents, including iohexol, ioversol, iobitridol, iopamidol, iodixanol, iomeprol, and iopromide, yielded positive results. Given the clinical necessity of transcatheter arterial chemoembolization, a 13-step rapid desensitization protocol with iodixanol was implemented. The procedure was completed without any breakthrough reactions. This case highlights desensitization as a feasible and effective strategy for patients with hypersensitivity to multiple ICM agents.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
4.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
8.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
9.Comparative analysis of surgical outcomes of laparoscopic appendectomy performed by six surgeons with different subspecialties: a retrospective cohort study using risk-adjusted cumulative summation
Ji Hyeong SONG ; Inyoung NA ; Song-Yi KIM ; Youn Ju LEE ; Sun Jong HAN ; Sang Il YOUN ; Sa-Hong MIN ; Jin Soo KIM
Annals of Surgical Treatment and Research 2025;109(3):207-214
Purpose:
Laparoscopic appendectomy, a routine surgical procedure for acute appendicitis, is commonly performed in general hospitals. However, postoperative outcomes based on surgical subspecialty have not been well established. This study aimed to compare surgical outcomes of laparoscopic appendectomy across different surgical subspecialties using risk-adjusted cumulative summation (RA-CUSUM) analysis.
Methods:
A retrospective analysis was conducted on 631 patients undergoing laparoscopic appendectomy between July 2020 and December 2022. Surgeons were categorized into gastrointestinal (GI) or non-GI groups and senior or young groups. Surgical failure was defined as operation time exceeding the mean plus 2 standard deviations, presence of postoperative complications, or readmission within 30 days after surgery. RA-CUSUM analysis was employed to evaluate surgical failure within each group.
Results:
The GI group performed more partial cecectomies (P = 0.017) and had longer operation times (P = 0.019) than the non-GI group. The senior group exhibited shorter operation time (P < 0.001), reduced length of stay (P = 0.011), and a higher complication rate (P < 0.001) than the young group. RA-CUSUM analysis indicated a decrease in surgical failure as accumulation progressed in both senior and young groups, as well as in the GI and non-GI groups.
Conclusion
Outcomes of laparoscopic appendectomy varied by subspecialty and length of experience. However, each surgeon showed trends of decreasing surgical failure over time. These results suggest that the surgeon’s subspecialty minimally affects the outcomes of laparoscopic appendectomy, reflecting its fundamental nature within general surgery.
10.Multiple Bone Metastasis Occurred 35 Years after Initial Lobectomy in a Patient with Follicular Thyroid Carcinoma: a Case Report
International Journal of Thyroidology 2025;18(1):90-95
Differentiated thyroid cancer (DTC), which primarily consists of papillary thyroid cancer (80%) and follicular thyroid cancer (10–20%) worldwide, is the most common form of thyroid cancer originating from follicular cells. Although DTC generally has a favorable prognosis, patient survival rates significantly decrease with distant metastases, which occur particularly in FTC through hematogenous spread. A 67-year-old female patient presented with back and thigh pain in October 2020, leading to the discovery of an L2 vertebral osteolytic lesion, with a history of thyroid lobectomy 35 years prior. Multiple bone metastases were identified through FDG PET/CT, and biopsy confirmed metastatic FTC, leading to completion thyroidectomy which revealed an 8 mm encapsulated follicular variant of PTC. The patient underwent three sessions of radioactive iodine therapy (RAIT) with a cumulative dose of 500 mCi and external beam radiation for bone metastasis. Despite treatment, subsequent imaging showed no significant improvement in metastatic lesions, and the patient developed persistent bicytopenia. Given the limited treatment response and ongoing complications, further high-dose RAIT was discontinued, and the patient continued follow-up with regular tumor marker assays and imaging studies. This case illustrates the importance of considering thyroid cancer when investigating bone metastasis with an unknown primary site. Furthermore, it highlights the necessity of accurate diagnosis, proper treatment, and vigilant follow-up in FTC management, particularly regarding the possibility of delayed distant metastasis in DTC patients.

Result Analysis
Print
Save
E-mail