1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.Ultrasound Findings Suggestive of Malignancy in Thyroid Nodules Classified as Follicular Lesion of Undetermined Significance or Follicular Neoplasm based on the 2017 Bethesda System for Reporting Thyroid Cytopathology
Heui Jin JUNG ; Na Lae EUN ; Eun Ju SON ; Jeong-Ah KIM ; Ji Hyun YOUK ; Hye Sun LEE ; Soyoung JEON
Journal of the Korean Society of Radiology 2025;86(1):114-126
Purpose:
To identify US findings suggestive of malignancy in thyroid nodules with follicular lesions of undetermined significance (FLUS) or follicular neoplasm (FN) on fine-needle aspiration cytology (FNAC) and evaluate the diagnostic performance.
Materials and Methods:
Seventy FLUS (n = 57) or FN (n = 13) nodules on FNAC that underwent surgical excision between February 2018 and November 2020 were selected. US findings were retrospectively reviewed. Orientation, margin, echogenicity, calcification, additional findings of the rim, echogenicity, heterogeneity of the solid portion, and the ratio of anterior posterior diameter to lateral diameter (criteria) were assessed. The diagnostic performances of US findings, criteria, and the Korean Society of Thyroid Radiology Thyroid Imaging Reporting and Data System (K-TIRADS) were evaluated using logistic regression analysis.
Results:
Microcalcification, homogeneous solid echotexture, and thickened rims were suggestive of malignancy. Our criteria showed a highest area under the ROC curve (AUC) value of 0.771, sensitivity of 97.14%, accuracy of 77.14%, positive predictive value of 93.33%, negative predictive value of 95.24%, and specificity of 97.14%. The criteria showed a significantly higher AUC value than K-TIRADS.
Conclusion
US findings of homogenous solid portions, thick rims, and microcalcifications suggested malignancy in nodules with FLUS or FN on FNAC. These additional US findings could improve the diagnostic performance of K-TIRADS.
3.A Nationwide Survey on Infection Prevention and Control in Acute Care Hospitals of Korea
Sun Hee NA ; Yubin SEO ; Hye Jin SHI ; In Sun HWANG ; Kyong A SHIN ; Kwang Yul SON ; Sung Ran KIM ; Myoungjin SHIN ; Hee-jung SON ; Ji Youn CHOI ; Heekyung CHUN ; Sook-Kyung PARK ; Jeongsuk SONG ; Namyi KIM ; Jacob LEE ; Joong Sik EOM
Journal of Korean Medical Science 2025;40(4):e41-
Background:
Healthcare-associated infections impose a significant burden on antibiotic usage, healthcare expenditures, and morbidity. Therefore, it is crucial to revise policies to minimize such losses. This nationwide survey aimed to evaluate infection prevention and control (IPC) components in healthcare facilities and encourage improvements in acute care hospitals with inadequate infection prevention settings. This study aims to enhance the infection control capabilities of healthcare facilities.
Methods:
From December 27, 2021, to May 13, 2022, we conducted a survey of 1,767 acute care hospitals in the Republic of Korea. A survey was conducted to evaluate the infection control components in 1,767 acute care hospitals. Infection control officers provided direct responses to a systematically developed questionnaire. Subsequently, 10% of the respondents were randomly selected for the site investigation.
Results:
Overall, 1,197 (67.7%) hospitals responded to the online survey. On-site investigations were conducted at 125 hospitals. Hospitals with ≥ 150 beds are advised to have an IPC team under Article 3 of the Medical Service Act; however, only 87.0% (598/687) of hospitals with ≥ 100 beds had one. Conversely, 22.7% (116/510) of hospitals with < 100 beds had an IPC team. Regulations for hand hygiene, waste management, healthcare worker protection and safety, environmental cleaning, standard precautions, and prevention of the transmission of multidrug-resistant pathogens were present in 84.2%, 80.1%, 77.4%, 76.2%, 75.8%, and 63.5% of the hospitals, respectively. Hospitals with < 100 beds had low availability of all categories of standard operating procedures.
Conclusion
This study is the first national survey of acute care hospitals in the Republic of Korea. The data presented in the current study will improve the understanding of IPC status and will help establish a survey system. Our survey provides a basis for improving policies related to IPC in healthcare facilities.
4.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
5.Ultrasound Findings Suggestive of Malignancy in Thyroid Nodules Classified as Follicular Lesion of Undetermined Significance or Follicular Neoplasm based on the 2017 Bethesda System for Reporting Thyroid Cytopathology
Heui Jin JUNG ; Na Lae EUN ; Eun Ju SON ; Jeong-Ah KIM ; Ji Hyun YOUK ; Hye Sun LEE ; Soyoung JEON
Journal of the Korean Society of Radiology 2025;86(1):114-126
Purpose:
To identify US findings suggestive of malignancy in thyroid nodules with follicular lesions of undetermined significance (FLUS) or follicular neoplasm (FN) on fine-needle aspiration cytology (FNAC) and evaluate the diagnostic performance.
Materials and Methods:
Seventy FLUS (n = 57) or FN (n = 13) nodules on FNAC that underwent surgical excision between February 2018 and November 2020 were selected. US findings were retrospectively reviewed. Orientation, margin, echogenicity, calcification, additional findings of the rim, echogenicity, heterogeneity of the solid portion, and the ratio of anterior posterior diameter to lateral diameter (criteria) were assessed. The diagnostic performances of US findings, criteria, and the Korean Society of Thyroid Radiology Thyroid Imaging Reporting and Data System (K-TIRADS) were evaluated using logistic regression analysis.
Results:
Microcalcification, homogeneous solid echotexture, and thickened rims were suggestive of malignancy. Our criteria showed a highest area under the ROC curve (AUC) value of 0.771, sensitivity of 97.14%, accuracy of 77.14%, positive predictive value of 93.33%, negative predictive value of 95.24%, and specificity of 97.14%. The criteria showed a significantly higher AUC value than K-TIRADS.
Conclusion
US findings of homogenous solid portions, thick rims, and microcalcifications suggested malignancy in nodules with FLUS or FN on FNAC. These additional US findings could improve the diagnostic performance of K-TIRADS.
6.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
7.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
8.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
9.A Nationwide Survey on Infection Prevention and Control in Acute Care Hospitals of Korea
Sun Hee NA ; Yubin SEO ; Hye Jin SHI ; In Sun HWANG ; Kyong A SHIN ; Kwang Yul SON ; Sung Ran KIM ; Myoungjin SHIN ; Hee-jung SON ; Ji Youn CHOI ; Heekyung CHUN ; Sook-Kyung PARK ; Jeongsuk SONG ; Namyi KIM ; Jacob LEE ; Joong Sik EOM
Journal of Korean Medical Science 2025;40(4):e41-
Background:
Healthcare-associated infections impose a significant burden on antibiotic usage, healthcare expenditures, and morbidity. Therefore, it is crucial to revise policies to minimize such losses. This nationwide survey aimed to evaluate infection prevention and control (IPC) components in healthcare facilities and encourage improvements in acute care hospitals with inadequate infection prevention settings. This study aims to enhance the infection control capabilities of healthcare facilities.
Methods:
From December 27, 2021, to May 13, 2022, we conducted a survey of 1,767 acute care hospitals in the Republic of Korea. A survey was conducted to evaluate the infection control components in 1,767 acute care hospitals. Infection control officers provided direct responses to a systematically developed questionnaire. Subsequently, 10% of the respondents were randomly selected for the site investigation.
Results:
Overall, 1,197 (67.7%) hospitals responded to the online survey. On-site investigations were conducted at 125 hospitals. Hospitals with ≥ 150 beds are advised to have an IPC team under Article 3 of the Medical Service Act; however, only 87.0% (598/687) of hospitals with ≥ 100 beds had one. Conversely, 22.7% (116/510) of hospitals with < 100 beds had an IPC team. Regulations for hand hygiene, waste management, healthcare worker protection and safety, environmental cleaning, standard precautions, and prevention of the transmission of multidrug-resistant pathogens were present in 84.2%, 80.1%, 77.4%, 76.2%, 75.8%, and 63.5% of the hospitals, respectively. Hospitals with < 100 beds had low availability of all categories of standard operating procedures.
Conclusion
This study is the first national survey of acute care hospitals in the Republic of Korea. The data presented in the current study will improve the understanding of IPC status and will help establish a survey system. Our survey provides a basis for improving policies related to IPC in healthcare facilities.
10.A Nationwide Survey on Infection Prevention and Control in Acute Care Hospitals of Korea
Sun Hee NA ; Yubin SEO ; Hye Jin SHI ; In Sun HWANG ; Kyong A SHIN ; Kwang Yul SON ; Sung Ran KIM ; Myoungjin SHIN ; Hee-jung SON ; Ji Youn CHOI ; Heekyung CHUN ; Sook-Kyung PARK ; Jeongsuk SONG ; Namyi KIM ; Jacob LEE ; Joong Sik EOM
Journal of Korean Medical Science 2025;40(4):e41-
Background:
Healthcare-associated infections impose a significant burden on antibiotic usage, healthcare expenditures, and morbidity. Therefore, it is crucial to revise policies to minimize such losses. This nationwide survey aimed to evaluate infection prevention and control (IPC) components in healthcare facilities and encourage improvements in acute care hospitals with inadequate infection prevention settings. This study aims to enhance the infection control capabilities of healthcare facilities.
Methods:
From December 27, 2021, to May 13, 2022, we conducted a survey of 1,767 acute care hospitals in the Republic of Korea. A survey was conducted to evaluate the infection control components in 1,767 acute care hospitals. Infection control officers provided direct responses to a systematically developed questionnaire. Subsequently, 10% of the respondents were randomly selected for the site investigation.
Results:
Overall, 1,197 (67.7%) hospitals responded to the online survey. On-site investigations were conducted at 125 hospitals. Hospitals with ≥ 150 beds are advised to have an IPC team under Article 3 of the Medical Service Act; however, only 87.0% (598/687) of hospitals with ≥ 100 beds had one. Conversely, 22.7% (116/510) of hospitals with < 100 beds had an IPC team. Regulations for hand hygiene, waste management, healthcare worker protection and safety, environmental cleaning, standard precautions, and prevention of the transmission of multidrug-resistant pathogens were present in 84.2%, 80.1%, 77.4%, 76.2%, 75.8%, and 63.5% of the hospitals, respectively. Hospitals with < 100 beds had low availability of all categories of standard operating procedures.
Conclusion
This study is the first national survey of acute care hospitals in the Republic of Korea. The data presented in the current study will improve the understanding of IPC status and will help establish a survey system. Our survey provides a basis for improving policies related to IPC in healthcare facilities.

Result Analysis
Print
Save
E-mail