1.Multifocal IOL Power Calculation Using the Barrett True-K Formula After Radial Keratotomy: A Case Report
Ji Hoon BAN ; Myung Ho CHO ; Jae Hyun KIM ; Jong Soo LEE
Journal of the Korean Ophthalmological Society 2026;67(2):67-72
Purpose:
To report the clinical utility of the Barrett True-K formula in predicting multifocal intraocular lens (IOL) power in a patient with corneal deformation caused by radial keratotomy (RK), where postoperative refractive power prediction is challenging.Case summary: A 61-year-old male who underwent RK 30 years ago presented for cataract surgery. Slit-lamp examination showed eight RK incisions in each eye. Refractive error was +3.25 D sph; -1.75 D cyl, axis 70 in the right eye and +2.75 D sph; -1.00 D cyl, axis 110 in the left. Uncorrected visual acuity was 0.32 in the right eye and 0.63 in the left. IOL power was calculated using the Barrett True-K formula on the IOLMaster 700, with a target refraction of -0.25 D, and a multifocal IOL was implanted. Six months after cataract surgery, both eyes achieved a fraction close to emmetropia, with best corrected visual acuity of 0.63 in the right eye and 1.0 in the left. No significant refractive shifts or other complications were observed during surgery or 6-month follow-up.
Conclusions
The Barrett True-K formula, which measures the actual corneal refractive power to compensate for corneal deformation, is expected to be clinically useful for multifocal IOL implantation during cataract surgery in eyes after RK.
2.The Korean Rectal Cancer Multidisciplinary Committee Clinical Practice Guidelines for Rectal Cancer version 2.0
Hyo Seon RYU ; Hyun Jung KIM ; Dong Hyun KANG ; Yoo-Kang KWAK ; Han Deok KWAK ; Yoon-Hye KWON ; Dalyon KIM ; Baek-Hui KIM ; Jae Hyun KIM ; Ji Hun KIM ; Jin Won KIM ; Tae Hyung KIM ; Hae Young KIM ; Soo Min NAM ; Gyoung Tae NOH ; Jun Woo BONG ; Nak Song SUNG ; Seon Hui SHIN ; Kil-Yong LEE ; Sung Chul LEE ; Sea-Won LEE ; Jung Won LEE ; Jong Min LEE ; Myung Hoon IHN ; Joo Han LIM ; Woong Bae JI ; Dae Hee PYO ; Young Ki HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2026;42(1):4-33
Rectal cancer, which accounts for approximately 40% of colorectal cancers, remains a major clinical concern. Recent advances in diagnostic imaging, surgical techniques, radiotherapy, and systemic treatment have steadily improved rectal cancer outcomes. Considering this, the Korean Rectal Cancer Multidisciplinary (KRCM) Committee has aimed to provide clinicians and policymakers with up-to-date, evidence-based clinical practice guidelines to support optimal decision-making, reflecting current evidence, the Korean healthcare context, and patient values and preferences. The Clinical Practice Guidelines for Rectal Cancer version 2.0 were developed through multidisciplinary collaboration with related academic societies, building upon and updating the KRCM Clinical Practice Guidelines version 1.0 (titled “Multidisciplinary guidelines for the management of rectal cancer”). These consensus guidelines of the KRCM were established based on a comprehensive literature review, evidence synthesis, with recommendation development guided by the GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology, and consideration of applicability in real-world clinical practice under the national health insurance system. Each recommendation has been presented with its strength and level of evidence.
3.Seasonal Trends of Major Respiratory, Gastrointestinal, and Other Viral Infections in Korea: An Analysis Before, During, and After the Coronavirus Disease 2019Pandemic
Su-Kyung LEE ; Ji Hyun KIM ; Hyun Soo KIM
Annals of Laboratory Medicine 2026;46(2):124-135
Some viral infections display distinct seasonal patterns influenced by factors such as climate, human behavior, and viral characteristics. In this review, we investigated the seasonality of 15 viral infections in Korea. We analyzed viruses for which national surveillance data are available from the Korea Disease Control and Prevention Agency, including influenza virus, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, metapneumovirus, human bocavirus, seasonal coronaviruses, enterovirus, adenovirus, norovirus, rotavirus, Japanese encephalitis virus, Hantaan virus, varicella–zoster virus, and mumps virus. In temperate climates, such as that in Korea, winter peaks are commonly observed for influenza, RSV, and norovirus infections, whereas enteroviruses are more prevalent in summer and early autumn. Parainfluenza viruses exhibit type-specific seasonality (circulating in warmer months from spring to autumn). During the coronavirus disease 2019 pandemic (2020– 2021), the incidence of most respiratory and gastrointestinal viral infections analyzed in this study declined substantially owing to non-pharmaceutical interventions, such as social distancing and mask-wearing. After the preventive measures were relaxed, many viruses initially exhibited delayed or atypical seasonal peaks. However, by 2024, the seasonality of most, but not all, viral infections had largely returned to their pre-pandemic patterns. We also reviewed factors influencing viral seasonality, including climatic conditions, vector activity, human behavior, immunity, and viral genetic variation. These findings highlight the dynamic nature of viral seasonality and reinforce the importance of timely surveillance and flexible public health responses tailored to each country’s epidemiological landscape.
4.High-Resolution Chromosomal Microarray with Diagnostic Potential for Detecting Exon-Level Copy Number Variations Using Targeted and Non-targeted Approaches
Yeseul KIM ; Jee-Soo LEE ; Boram KIM ; Man Jin KIM ; Sung Im CHO ; Seung Won CHAE ; Ho Seob SHIN ; Hoyeon LEE ; Ji Yeon KIM ; Moon-Woo SEONG
Annals of Laboratory Medicine 2026;46(2):190-199
Background:
Copy number variations (CNVs) play an important role in human genetic disorders. Detection of exon-level CNVs is crucial for accurate clinical diagnosis. The CytoScan XON Array, a high-resolution microarray, was recently developed to detect exonic CNVs of various genes.
Methods:
We evaluated the clinical performance of the CytoScan XON Array using 59 patient samples with previously identified CNVs, confirmed via methods including multiple ligation-dependent probe amplification (MLPA), gene-dose PCR, and mRNA assay. Concordance between CytoScan XON and orthogonal methods was evaluated in target regions, and diagnostic utility was compared with that of genome sequencing (GS)-based CNV calling tools through analysis of false-positive CNVs in non-target genomic regions.
Results:
For target regions, the CytoScan XON Array achieved concordance rates of 89.8% and 92.5% at the exon and gene levels, respectively, for all CNV calls. Concordance was higher for multi-exon CNVs (100%) than that for single-exon CNVs (82.6%, P = 0.03). For non-target regions, false-positive CNV calls were reduced to fewer than 0.01 per gene per person through filtering strategies. The array exhibited false-positive detection rates within dosage-sensitive genes comparable with those of GS-based tools.
Conclusions
The CytoScan XON Array, a reliable tool for detecting exon-level CNVs in target regions, can serve as a complementary approach to GS-based CNV calling tools for genome-wide CNV screening with high resolution. However, its performance for single-exon CNVs requires further optimization. Cross-validation with GS-based CNV calling tools is recommended to improve diagnostic accuracy.
5.Acute health effects of accidental exposure to lithium hydroxide at a battery material production plant
Chul Gab LEE ; Soo Hyeong PARK ; Ji Won KANG ; Si Woo HWANG ; Hyeo Na KIM ; Hyeon Kyeong KO
Annals of Occupational and Environmental Medicine 2026;38(1):e6-
Background:
Lithium hydroxide (LiOH) is increasingly used in electric vehicle battery production; however, its health effects in the work environment remain underreported. This study characterizes the acute health effects on workers following accidental occupational exposure to LiOH at a Korean lithium plant in March 2024.
Methods:
We analyzed health effects from two LiOH exposure accidents on March 6 and 9, 2024, involving 50–100 kg powder spills. Two datasets were examined: acute symptoms from 115 workers who visited hospitals immediately after exposure, and a symptom severity survey from 474 workers conducted 2 weeks post-exposure. Workers were stratified by distance from the leak source (<10 m, 10–20 m, >20 m) and respirator use. Univariate general linear modeling was applied to analyze the relationship between symptom occurrence and both the distance from the exposure source and respirator use.
Results:
Among workers visiting hospitals immediately, local irritation symptoms predominated: sore throat (58.3%), cough (28.7%), and skin dermatoses (17.4%). Systemic symptoms included headache (45.2%), nausea (18.3%), chest tightness (12.2%), and dizziness (9.6%). Two-week follow-up revealed overall symptom improvement; severe cough decreased from 22.2% to 10.1%. However, despite general improvement, a significant portion of workers reported persistent respiratory issues, including cough (28.7%) and sputum production (31.0%). Symptom severity showed a significant dose-response relationship with proximity to the source (p < 0.001). While respirator use offered initial protection (p = 0.021), this effect was not statistically significant after 2 weeks.
Conclusions
Occupational LiOH exposure caused acute irritation and systemic symptoms, demonstrating immediate tissue damage consistent with its alkalinity and systemic toxicity upon absorption. As lithium battery production expands globally, these results emphasize the necessity for developing specific occupational exposure limits and medical surveillance guidelines for lithium compounds.
6.Percutaneous Endoscopic Debridement and Drainage for Infectious Spondylodiscitis Under Local Anesthesia
Ji-Ho JUNG ; Jong-Hoon JEONG ; Jong-Hwan HONG ; Moon-Soo HAN ; Jung-Kil LEE
Journal of Minimally Invasive Spine Surgery and Technique 2026;11(1):163-168
This video demonstrates the surgical technique of percutaneous endoscopic debridement and drainage (PEDD) for infectious spondylodiscitis performed under local anesthesia. Two representative cases are presented. The first case underwent transforaminal PEDD for L2–3 infectious spondylodiscitis, and the second case underwent combined transforaminal PEDD and drainage of a psoas abscess. In both cases, needle insertion was guided by C-arm fluoroscopy, followed by root block, discography, serial dilation, and insertion of a 3.7-mm endoscope. Under endoscopic visualization, necrotic disc material and infected granulation tissue were removed, and samples were collected for culture and biopsy. The procedure also enabled safe placement of a drainage catheter into the abscess cavity. Postoperatively, one patient improved with intravenous antibiotics after identification of Streptococcus constellatus, while the other was diagnosed with tuberculous spondylodiscitis and treated with antituberculosis therapy. Both patients showed gradual improvement in back pain and normalization of inflammatory markers. This video provides a detailed step-by-step guide to PEDD, highlighting its diagnostic and therapeutic advantages in infectious spondylodiscitis, as well as its educational value for surgeons learning full-endoscopic spine surgery.
7.Comparative analysis of hematological changes in patients with rheumatoid arthritis treated with different Janus kinase inhibitors: a real-world study
Soo Min AHN ; Ji Seon OH ; Yong-Gil KIM ; Chang-Keun LEE ; Bin YOO ; Seokchan HONG
Journal of Rheumatic Diseases 2026;33(2):86-94
Objective:
Janus kinase (JAK) inhibitors are widely used to treat rheumatoid arthritis (RA); however, comparative analyses regarding their adverse events remain limited. This study aimed to compare the effects of different JAK inhibitors (tofacitinib, baricitinib, and upadacitinib) on hematological parameters in patients with RA in a real-world setting.
Methods:
This retrospective analysis included 552 patients with RA treated with JAK inhibitors between August 2015 and February 2024. Hematological parameters, including absolute neutrophil count (ANC) and platelet count, were assessed at baseline and after 6 months of treatment. Statistical analysis was performed to evaluate changes over time, and logistic regression analysis identified factors associated with hematologic alterations.
Results:
The 552 patients were divided into three groups: tofacitinib (n=264), baricitinib (n=143), and upadacitinib (n=145). No significant differences in baseline hematological parameters were observed across the groups. After 6 months, ANC decreased in all groups without significant differences among them (p=0.465). Patients receiving baricitinib had significantly higher platelet counts than those receiving tofacitinib (Pillai’s trace value of 0.063, p<0.001) or upadacitinib (Pillai’s trace value of 0.029, p<0.001).Multivariate analysis revealed that baricitinib was significantly associated with increased platelet counts (odds ratio, 2.009; 95% confidence interval, 1.212~3.331; p=0.007).
Conclusion
Although all three JAK inhibitors reduced ANC, baricitinib was associated with a substantial increase in platelet counts. These findings highlight the differences in adverse effect profiles among JAK inhibitors, emphasizing the importance of tailored monitoring in RA management.
8.Association of Breast Tissue Composition on Preoperative Automated Breast Ultrasound With Accuracy of Cancer Multiplicity Evaluation and Recurrence-Free Survival in Patients With Early-Stage Breast Cancer
Myoung Kyoung KIM ; Haejung KIM ; Sun-Young BAEK ; Eun Young KO ; Boo-Kyung HAN ; Eun Sook KO ; Jeongmin LEE ; Nami CHOI ; Jin CHUNG ; Ji Soo CHOI
Korean Journal of Radiology 2026;27(2):97-110
Objective:
To investigate whether breast tissue composition on preoperative automated breast ultrasound (ABUS) is associated with the accuracy of cancer multiplicity evaluation and postoperative recurrence-free survival (RFS) in patients with early-stage breast cancer.
Materials and Methods:
This retrospective analysis included women with early-stage breast cancer (clinical Tis, T1–2/N0) who underwent ABUS and digital mammography (DM) between October 2019 and April 2021. Tissue composition on ABUS was assessed using the Breast Imaging Reporting and Data System background echotexture (BE) (homogeneous-fat, homogeneous-fibroglandular, or heterogeneous). In a subgroup of patients with mammographically dense breasts, the glandular tissue component (GTC) on ABUS were further stratified into high (moderate or marked) or low (minimal or mild).Multivariable logistic and Cox regression analyses were used to identify factors associated with accurate cancer multiplicity categorization (unifocal, multifocal/multicentric, or bilateral) using ABUS + DM, and with RFS, respectively.
Results:
Among 409 women (mean age ± standard deviation, 50.2 ± 8.7 years), ABUS combined with DM yielded accurate cancer multiplicity categorization in 368 patients (90.0%). Neither BE nor GTC on ABUS affected the accuracy of categorization when ABUS was combined with DM. Over a median postoperative follow-up of 3.5 years, 11 recurrences occurred. Heterogeneous BE on ABUS (hazard ratio [HR] 11.24 [95% confidence interval [CI]: 2.82–44.92]; P = 0.001), BRCA mutation (HR 15.94 [2.47–102.97]; P = 0.004), and pathologic index cancer size (HR per 1-cm increase 1.91 [1.13–3.23];P = 0.02) was independently associated with RFS. In patients with dense breasts, heterogeneous BE (HR 14.17 [95% CI:2.69–74.60]; P = 0.002) and high GTC (HR 10.32 [2.35–45.28]; P = 0.002) on ABUS, BRCA mutation (HR 24.34 [2.75– 215.06]; P = 0.004), and pathologic cancer size (HR per 1-cm increase 2.62 [1.50–4.59]; P = 0.001) was independently associated with RFS.
Conclusion
In patients with early-stage breast cancer, heterogeneous BE and high GTC on preoperative ABUS, along with larger cancer size and BRCA mutation, was associated with worse RFS. However, BE and GTC did not affect cancer multiplicity evaluation when ABUS was used in combination with DM.
9.Screening Outcomes of Supplemental Automated Breast Ultrasound in Women With Nondense Breasts Undergoing Mammography
Mi-ri KWON ; Mi Yeon LEE ; Suhyeon MOON ; Eun Sook KO ; Eun Young KO ; Boo Kyung HAN ; Inyoung YOUN ; Yoon Jung CHOI ; Shin Ho KOOK ; Jai Min RYU ; Ji Soo CHOI
Korean Journal of Radiology 2026;27(1):14-26
Objective:
To evaluate the performance of supplemental automated breast ultrasound (ABUS) added to mammography-based breast cancer screening for women with nondense breasts.
Materials and Methods:
A retrospective search of radiology databases at two tertiary institutions identified asymptomatic women with nondense breasts who underwent breast cancer screening using both digital mammography (DM) and supplemental ABUS between January 2020 and December 2023. We excluded women without sufficient follow-up data or those without an established final diagnosis, including histopathologic results. The performance measures of DM alone and ABUS combined with DM (ABUS plus DM) were compared. The primary outcome was the cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed for women with scattered fibroglandular density and almost entirely fatty breasts.
Results:
A total of 2,904 pairs of screening examinations were performed in 1,683 women (59 ± 10 years), detecting 26 cancers. In comparison with DM alone, ABUS plus DM showed higher CDR (9.0 vs. 7.9 per 1,000 examinations, P < 0.001), higher sensitivity (100% [26/26] vs. 88.5% [23/26], P < 0.001), and lower specificity (95.0% [2,735/2,878] vs. 97.9% [2,817/2,878], P < 0.001). In women with scattered fibroglandular density, ABUS increased the CDR from 7.4 to 8.5 per 1,000 examinations and improved the sensitivity from 87.0% [20/23] to 100% [23/23] (P < 0.001). In women with almost entirely fatty breasts, ABUS plus DM showed the same CDR (16.4 per 1,000 examinations) and sensitivity (100% [3/3]) as DM alone. Three cancers (11.5% [3/26]), all of which were stage T1N0, were detected only by supplemental ABUS.
Conclusion
Supplemental ABUS improved cancer detection and sensitivity in women with nondense breasts, with the benefits primarily observed in those with scattered fibroglandular density.
10.Lumbar spinal stenosis: current concept of management
Ji-Won KWON ; Kyung-Soo SUK ; Seong-Hwan MOON ; Si-Young PARK ; Namhoo KIM ; Sub-Ri PARK ; Jae-Won SHIN ; Hak-Sun KIM ; Byung Ho LEE
Asian Spine Journal 2026;20(1):143-157
Lumbar spinal stenosis (LSS) is a common degenerative spinal condition where spinal canal narrowing causes symptoms such as neurogenic claudication, radiculopathy, and lower back pain. While non-operative and surgical approaches yield similar long-term outcomes, surgical intervention—particularly decompression—can provide earlier symptom relief, functional recovery, and fall prevention in selected patients with refractory symptoms. Recent advancements in surgical technologies and image guidance have brought about a paradigm shift in LSS management. Biportal endoscopic spine surgery (BESS) has gained global traction as a minimally invasive alternative to traditional decompression methods, offering superior visualization, less soft tissue damage, shorter hospital stays, and faster recovery. High-quality studies, including randomized controlled trials, have shown promising outcomes for this technique. Furthermore, the integration of navigation systems, robot-assisted instrumentation, and artificial intelligence (AI)-driven diagnostics and surgical planning tools is transforming spinal surgery by enhancing precision in preoperative evaluation and intraoperative execution. These innovations enable accurate targeting, reduce complications, and improve reproducibility across diverse surgical settings. This review provides an updated overview of LSS, covering its pathophysiology, clinical assessment, diagnosis, and treatment. Special emphasis is placed on the growing role of BESS and the transformative impact of digital technologies such as navigation, robotics, and AI in the evolving landscape of spinal stenosis care.

Result Analysis
Print
Save
E-mail