4.Association between Gamma-Glutamyl Transferase Levels and Pancreatobiliary Cancer Risk in Patients with Diabetes: Evidence from the National Health Insurance Cooperation Health Checkup 2009 to 2012
Ji Hye HEO ; Jun Goo KANG ; Kyungdo HAN ; Kyong Joo LEE
Gut and Liver 2025;19(2):286-296
Background/Aims:
Elevated gamma-glutamyl transferase (GGT) levels indicate hepatic dysfunction and have been linked to an increased risk of pancreatobiliary cancers. However, this association, particularly in individuals with diabetes mellitus (DM), requires elucidation. We aimed to examine the association between elevated serum GGT levels and pancreatobiliary cancer risk in patients with diabetes.
Methods:
Our study included data from the National Health Insurance Service (NHIS) database for 2,459,966 adults aged >20 years diagnosed with DM between 2009 and 2012. We examined the association between serum GGT levels and pancreatobiliary cancer risk, considering DMrelated factors. Serum GGT levels were categorized into quartiles, and Cox proportional hazards analysis was performed to evaluate the association between serum GGT levels and pancreatobiliary cancer risk.
Results:
Over a median follow-up period of 7.2 years, 21,795 patients (0.89%) were newly diagnosed with pancreatobiliary cancer. The adjusted hazard ratio for pancreatobiliary cancer in quartiles 2–4 compared with that in quartile 1 was 1.091, 1.223, and 1.554, respectively, demonstrating a significant upward trend (p<0.001). This association remained consistent across all cancer types and was independent of the DM duration or treatment regimen.
Conclusions
Elevated serum GGT levels were independently associated with an increased risk of pancreatobiliary cancer, regardless of the duration of DM or the use of oral hypoglycemic agents and insulin. While these findings suggest the potential utility of serum GGT as a biomarker for identifying individuals at higher risk of pancreatobiliary cancer within the diabetic population, further research is needed to validate its clinical applicability.
7.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
9.Impact of portal/superior mesenteric vein abutment angle on prognosis in pancreatic cancer: a single-center retrospective cohort study
Hye Jeong JEONG ; DanHui HEO ; Soo Yeun LIM ; Hyeong Seok KIM ; Hochang CHAE ; So Jeong YOON ; Sang Hyun SHIN ; In Woong HAN ; Jin Seok HEO ; Ji Hye MIN ; Hongbeom KIM
Annals of Surgical Treatment and Research 2025;108(4):231-239
Purpose:
Pancreatic cancer has a poor prognosis; however, the implementation of neoadjuvant treatment enables borderline resectable cases to undergo curative resection and improves the overall survival rate. Attempts have been made to expand the eligibility criteria for neoadjuvant treatment, even in resectable cases. Some studies have suggested a correlation between vein abutment and poor prognosis or that the abutment angle may affect prognosis. This study investigated the anatomical factors affecting the vessel abutment angle and its prognostic value in pancreatic cancer.
Methods:
Patients with pancreatic ductal adenocarcinoma who underwent surgery between 2012 and 2017 were included in this study. Patients who underwent neoadjuvant treatment were excluded. Data from only the intent-to-treat pancreaticoduodenectomy group were included in the analysis. Clinicopathological characteristics; preoperative factors such as CA 19-9, preoperative biliary drainage, American Society of Anesthesiologists physical status classification, portal vein/superior mesenteric vein contact angle measured via CT scan; and intraoperative factors were collected for analysis.
Results:
A total of 365 patients were included in this study, and the abutment group included 92 patients (25.2%). The abutment and no-contact groups did not show any significant differences in terms of the overall survival or diseasefree survival rate. Among the abutment groups, patients with less than 90° and 90°–180° did not show any significant differences. In the multivariate analysis, the only preoperative factor that had a prognostic effect was CA 19-9, a biological factor.
Conclusion
When there is no vessel invasion in the abutment group, upfront surgery should be considered because the angle does not affect the overall prognosis.
10.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.

Result Analysis
Print
Save
E-mail