1.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
2.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
3.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
4.Literature review of non-pharmacological treatment for patients with axial spondyloarthritis
Jina YEO ; Mi Ryoung SEO ; Jun Won PARK ; Yeon-Ah LEE ; Ju Ho LEE ; Eun Ha KANG ; Seon Mi JI ; Han Joo BAEK
The Korean Journal of Internal Medicine 2025;40(1):40-48
Axial spondyloarthritis (axSpA) is a chronic inflammatory disorder affecting the sacroiliac joints and axial spine. Along with pharmacotherapy, non-pharmacological interventions for axSpA are crucial and constitute the cornerstone of treatment. Here, we review the evidence for non-pharmacological treatment of axSpA as a basis for the 2023 Korean treatment recommendations for patients with axSpA. The effectiveness of the core non-pharmacological approaches, such as education, smoking cessation, and exercise, has been reaffirmed. High-quality research on surgical treatment is limited. However, total hip replacement is advised in patients with ongoing pain or disability and visible structural damage to the hip on imaging. Urgent spinal intervention should be considered in cases of acute spinal pain with neurological deficiency or concurrent unstable fractures. Evidence for complementary therapies, including spas and acupuncture, remains insufficient.
5.Tuberculous and Malignant Pleural Effusions With Adenosine Deaminase Levels of 40–70 IU/L: Trends in New Cases Over Time and Differentiation Between Groups
Jaehee LEE ; Jongmin PARK ; Jae Kwang LIM ; Ji Eun PARK ; Yong Hoon LEE ; Sun Ha CHOI ; Hyewon SEO ; Seung Soo YOO ; Shin Yup LEE ; Seung-Ick CHA ; Jae Yong PARK ; Chang Ho KIM
Journal of Korean Medical Science 2025;40(13):e35-
Background:
The diagnosis of tuberculous pleural effusion (TPE) often relies on pleural fluid adenosine deaminase (ADA) levels. The diagnostic utility of ADA, however, is influenced by the prevalence of tuberculosis (TB) in local populations. Malignant pleural effusion (MPE) cases can exhibit moderately elevated ADA levels comparable to those seen in TPE. As population aging potentially impacts ADA levels, global TB incidence is decreasing whereas the burden of malignancy is on the rise. Consequently, epidemiological shifts and temporal changes in ADA distribution complicate the differential diagnosis between TPE and MPE when ADA levels are within the 40–70 IU/L range. Nonetheless, data specific to this subset are scarce.
Methods:
This retrospective study included consecutive patients aged > 18 years with confirmed TPE and MPE, spanning from 2012 to 2023. ADA levels in pleural fluid were categorized into three groups: < 40 IU/L, 40–70 IU/L, and > 70 IU/L. The study examined annual trends in the frequency of new cases and ADA level distributions over time and identified discriminating factors between TPE and MPE in cases with ADA levels of 40–70 IU/L.
Results:
In total, 297 TPE and 369 MPE cases were included in this study. Over the study period, the frequency of TPE progressively declined, while that of MPE increased. In the most recent four-year period, new TPE and MPE cases with ADA levels of 40–70 IU/L occurred at comparable numbers. Multivariable analysis identified pleural fluid carcinoembryonic antigen (CEA) levels and the number of focal pleural nodules as independent predictors for MPE. Specifically, the presence of either CEA levels > 15.7 ng/mL or more than eight pleural nodules yielded the highest diagnostic accuracy with a sensitivity of 88%, specificity of 100%, and an area under the curve of 0.95.
Conclusion
The differential diagnosis between TPE and MPE with pleural ADA levels of 40–70 IU/L has become increasingly critical due to evolving epidemiological patterns and ADA distribution changes over time. Pleural fluid CEA levels and the characteristics of pleural nodules may offer valuable guidance in distinguishing between TPE and MPE within this diagnostic gray zone.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Tuberculous and Malignant Pleural Effusions With Adenosine Deaminase Levels of 40–70 IU/L: Trends in New Cases Over Time and Differentiation Between Groups
Jaehee LEE ; Jongmin PARK ; Jae Kwang LIM ; Ji Eun PARK ; Yong Hoon LEE ; Sun Ha CHOI ; Hyewon SEO ; Seung Soo YOO ; Shin Yup LEE ; Seung-Ick CHA ; Jae Yong PARK ; Chang Ho KIM
Journal of Korean Medical Science 2025;40(13):e35-
Background:
The diagnosis of tuberculous pleural effusion (TPE) often relies on pleural fluid adenosine deaminase (ADA) levels. The diagnostic utility of ADA, however, is influenced by the prevalence of tuberculosis (TB) in local populations. Malignant pleural effusion (MPE) cases can exhibit moderately elevated ADA levels comparable to those seen in TPE. As population aging potentially impacts ADA levels, global TB incidence is decreasing whereas the burden of malignancy is on the rise. Consequently, epidemiological shifts and temporal changes in ADA distribution complicate the differential diagnosis between TPE and MPE when ADA levels are within the 40–70 IU/L range. Nonetheless, data specific to this subset are scarce.
Methods:
This retrospective study included consecutive patients aged > 18 years with confirmed TPE and MPE, spanning from 2012 to 2023. ADA levels in pleural fluid were categorized into three groups: < 40 IU/L, 40–70 IU/L, and > 70 IU/L. The study examined annual trends in the frequency of new cases and ADA level distributions over time and identified discriminating factors between TPE and MPE in cases with ADA levels of 40–70 IU/L.
Results:
In total, 297 TPE and 369 MPE cases were included in this study. Over the study period, the frequency of TPE progressively declined, while that of MPE increased. In the most recent four-year period, new TPE and MPE cases with ADA levels of 40–70 IU/L occurred at comparable numbers. Multivariable analysis identified pleural fluid carcinoembryonic antigen (CEA) levels and the number of focal pleural nodules as independent predictors for MPE. Specifically, the presence of either CEA levels > 15.7 ng/mL or more than eight pleural nodules yielded the highest diagnostic accuracy with a sensitivity of 88%, specificity of 100%, and an area under the curve of 0.95.
Conclusion
The differential diagnosis between TPE and MPE with pleural ADA levels of 40–70 IU/L has become increasingly critical due to evolving epidemiological patterns and ADA distribution changes over time. Pleural fluid CEA levels and the characteristics of pleural nodules may offer valuable guidance in distinguishing between TPE and MPE within this diagnostic gray zone.
8.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.

Result Analysis
Print
Save
E-mail