1.Erratum: Clinical Feasibility of Vascular Navigation System During Laparoscopic Gastrectomy for Gastric Cancer: A Retrospective Comparison With Propensity-Score Matching
Ji Eun JUNG ; Jeong Ho SONG ; Seyeol OH ; Sang-Yong SON ; Hoon HUR ; In Gyu KWON ; Sang-Uk HAN
Journal of Gastric Cancer 2025;25(2):403-403
2.Effects of an intervention combining warm therapy with a digital distraction app on pain, stress, and satisfaction during intravenous catheterization in South Korea: a randomized controlled trial
Jae-Kyeum LEE ; Ki-Yong KIM ; Yean-Hee JEONG ; Yu-Jin LEE ; Min-Ho LEE ; Myung-Haeng HUR
Journal of Korean Biological Nursing Science 2025;27(2):191-202
Purpose:
This study aimed to evaluate the effects of an intervention combining warm therapy (via a thermoelectric-element tourniquet) and a distraction-based approach (via an augmented reality-based app known as TWINKLE) on pain, stress, and satisfaction during intravenous catheterization in adults.
Methods:
A randomized controlled trial was conducted in South Korea with 93 healthy adults who were randomly assigned to one of three groups: the experimental group (TWINKLE app with warm therapy), the comparison group (warm therapy only), and the control group (no treatment). Participants’ pain, stress, and satisfaction, as well as practitioner satisfaction, were measured after the intervention.
Results:
Pain scores differed significantly among the three groups (F = 5.68, p = .005), with the experimental group showing significantly lower scores than the control group (p = .003). Stress levels were also significantly lower in the experimental group than in the other groups (F = 9.42, p < .001). Participant satisfaction was highest in the experimental group (F = 17.65, p < .001), while nurse satisfaction was significantly higher in the comparison group than in the experimental and control groups (F = 67.91, p < .001), suggesting that the additional distraction intervention may have increased nurses’ workload.
Conclusion
Combining digital distraction with warm therapy using a thermoelectric-element tourniquet effectively reduces pain and stress while improving patient satisfaction during intravenous catheterization. Further research is needed to optimize this approach, with a particular focus on targeting digital distraction interventions to patients with higher levels of procedural anxiety and finding ways to minimize practitioner workload.
3.Effects of an intervention combining warm therapy with a digital distraction app on pain, stress, and satisfaction during intravenous catheterization in South Korea: a randomized controlled trial
Jae-Kyeum LEE ; Ki-Yong KIM ; Yean-Hee JEONG ; Yu-Jin LEE ; Min-Ho LEE ; Myung-Haeng HUR
Journal of Korean Biological Nursing Science 2025;27(2):191-202
Purpose:
This study aimed to evaluate the effects of an intervention combining warm therapy (via a thermoelectric-element tourniquet) and a distraction-based approach (via an augmented reality-based app known as TWINKLE) on pain, stress, and satisfaction during intravenous catheterization in adults.
Methods:
A randomized controlled trial was conducted in South Korea with 93 healthy adults who were randomly assigned to one of three groups: the experimental group (TWINKLE app with warm therapy), the comparison group (warm therapy only), and the control group (no treatment). Participants’ pain, stress, and satisfaction, as well as practitioner satisfaction, were measured after the intervention.
Results:
Pain scores differed significantly among the three groups (F = 5.68, p = .005), with the experimental group showing significantly lower scores than the control group (p = .003). Stress levels were also significantly lower in the experimental group than in the other groups (F = 9.42, p < .001). Participant satisfaction was highest in the experimental group (F = 17.65, p < .001), while nurse satisfaction was significantly higher in the comparison group than in the experimental and control groups (F = 67.91, p < .001), suggesting that the additional distraction intervention may have increased nurses’ workload.
Conclusion
Combining digital distraction with warm therapy using a thermoelectric-element tourniquet effectively reduces pain and stress while improving patient satisfaction during intravenous catheterization. Further research is needed to optimize this approach, with a particular focus on targeting digital distraction interventions to patients with higher levels of procedural anxiety and finding ways to minimize practitioner workload.
4.Effects of an intervention combining warm therapy with a digital distraction app on pain, stress, and satisfaction during intravenous catheterization in South Korea: a randomized controlled trial
Jae-Kyeum LEE ; Ki-Yong KIM ; Yean-Hee JEONG ; Yu-Jin LEE ; Min-Ho LEE ; Myung-Haeng HUR
Journal of Korean Biological Nursing Science 2025;27(2):191-202
Purpose:
This study aimed to evaluate the effects of an intervention combining warm therapy (via a thermoelectric-element tourniquet) and a distraction-based approach (via an augmented reality-based app known as TWINKLE) on pain, stress, and satisfaction during intravenous catheterization in adults.
Methods:
A randomized controlled trial was conducted in South Korea with 93 healthy adults who were randomly assigned to one of three groups: the experimental group (TWINKLE app with warm therapy), the comparison group (warm therapy only), and the control group (no treatment). Participants’ pain, stress, and satisfaction, as well as practitioner satisfaction, were measured after the intervention.
Results:
Pain scores differed significantly among the three groups (F = 5.68, p = .005), with the experimental group showing significantly lower scores than the control group (p = .003). Stress levels were also significantly lower in the experimental group than in the other groups (F = 9.42, p < .001). Participant satisfaction was highest in the experimental group (F = 17.65, p < .001), while nurse satisfaction was significantly higher in the comparison group than in the experimental and control groups (F = 67.91, p < .001), suggesting that the additional distraction intervention may have increased nurses’ workload.
Conclusion
Combining digital distraction with warm therapy using a thermoelectric-element tourniquet effectively reduces pain and stress while improving patient satisfaction during intravenous catheterization. Further research is needed to optimize this approach, with a particular focus on targeting digital distraction interventions to patients with higher levels of procedural anxiety and finding ways to minimize practitioner workload.
5.Erratum: Clinical Feasibility of Vascular Navigation System During Laparoscopic Gastrectomy for Gastric Cancer: A Retrospective Comparison With Propensity-Score Matching
Ji Eun JUNG ; Jeong Ho SONG ; Seyeol OH ; Sang-Yong SON ; Hoon HUR ; In Gyu KWON ; Sang-Uk HAN
Journal of Gastric Cancer 2025;25(2):403-403
6.Erratum: Clinical Feasibility of Vascular Navigation System During Laparoscopic Gastrectomy for Gastric Cancer: A Retrospective Comparison With Propensity-Score Matching
Ji Eun JUNG ; Jeong Ho SONG ; Seyeol OH ; Sang-Yong SON ; Hoon HUR ; In Gyu KWON ; Sang-Uk HAN
Journal of Gastric Cancer 2025;25(2):403-403
7.Effects of an intervention combining warm therapy with a digital distraction app on pain, stress, and satisfaction during intravenous catheterization in South Korea: a randomized controlled trial
Jae-Kyeum LEE ; Ki-Yong KIM ; Yean-Hee JEONG ; Yu-Jin LEE ; Min-Ho LEE ; Myung-Haeng HUR
Journal of Korean Biological Nursing Science 2025;27(2):191-202
Purpose:
This study aimed to evaluate the effects of an intervention combining warm therapy (via a thermoelectric-element tourniquet) and a distraction-based approach (via an augmented reality-based app known as TWINKLE) on pain, stress, and satisfaction during intravenous catheterization in adults.
Methods:
A randomized controlled trial was conducted in South Korea with 93 healthy adults who were randomly assigned to one of three groups: the experimental group (TWINKLE app with warm therapy), the comparison group (warm therapy only), and the control group (no treatment). Participants’ pain, stress, and satisfaction, as well as practitioner satisfaction, were measured after the intervention.
Results:
Pain scores differed significantly among the three groups (F = 5.68, p = .005), with the experimental group showing significantly lower scores than the control group (p = .003). Stress levels were also significantly lower in the experimental group than in the other groups (F = 9.42, p < .001). Participant satisfaction was highest in the experimental group (F = 17.65, p < .001), while nurse satisfaction was significantly higher in the comparison group than in the experimental and control groups (F = 67.91, p < .001), suggesting that the additional distraction intervention may have increased nurses’ workload.
Conclusion
Combining digital distraction with warm therapy using a thermoelectric-element tourniquet effectively reduces pain and stress while improving patient satisfaction during intravenous catheterization. Further research is needed to optimize this approach, with a particular focus on targeting digital distraction interventions to patients with higher levels of procedural anxiety and finding ways to minimize practitioner workload.
8.A phase 1/2a, dose-escalation, safety, and preliminary efficacy study of the RKP00156 vaginal tablet in healthy women and patients with cervical intraepithelial neoplasia 2
Hyun-Woong CHO ; Sohyeon JEONG ; Seung Hun SONG ; Young Tae KIM ; Jae-Weon KIM ; Chi-Heum CHO ; Soo Young HUR ; Suk-Joon CHANG ; Yong Man KIM ; Jae Kwan LEE
Journal of Gynecologic Oncology 2024;35(4):e52-
Objective:
This study aimed to determine the safety and efficacy of the RKP00156 vaginal tablet, a CDK9 inhibitor, in healthy women and patients with cervical intraepithelial neoplasia grade 2 (CIN2).
Methods:
We conducted a phase 1/2a clinical trial of RKP00156. In step 1, RKP00156 at a dose of 10, 25, or 50 mg or a placebo tablet was administered transvaginally to 24 healthy women.In step 2, RKP00156 at a dose of 10, 25, or 50 mg or a placebo tablet was administered once daily for 4 weeks in 62 patients with CIN2. The primary endpoints of this trial were the safety of RKP00156 and the change in the human papillomavirus (HPV) viral load.
Results:
A total of 86 patients were enrolled and randomized. RKP00156 administration did not cause serious drug-associated adverse events (AEs). Although no significant difference in the HPV viral load was found between the experimental and placebo groups, a reduction in the HPV viral load was observed in the 25 mg-dose group (−98.61%; 95% confidence interval=−99.83%, 4.52%; p=0.046) after treatment completion in patients with a high HPV viral load, despite a lack of statistical power. No differences in histologic regression and HPV clearance were observed.
Conclusion
The safety of RKP00156 was proved with no serious AEs. Although the study did not show any significance in histologic regression and HPV clearance, our findings indicate that RKP00156 may have a possibility of short-term inhibitory effect on HPV replication in patients with higher viral loads.
9.A phase 1/2a, dose-escalation, safety, and preliminary efficacy study of the RKP00156 vaginal tablet in healthy women and patients with cervical intraepithelial neoplasia 2
Hyun-Woong CHO ; Sohyeon JEONG ; Seung Hun SONG ; Young Tae KIM ; Jae-Weon KIM ; Chi-Heum CHO ; Soo Young HUR ; Suk-Joon CHANG ; Yong Man KIM ; Jae Kwan LEE
Journal of Gynecologic Oncology 2024;35(4):e52-
Objective:
This study aimed to determine the safety and efficacy of the RKP00156 vaginal tablet, a CDK9 inhibitor, in healthy women and patients with cervical intraepithelial neoplasia grade 2 (CIN2).
Methods:
We conducted a phase 1/2a clinical trial of RKP00156. In step 1, RKP00156 at a dose of 10, 25, or 50 mg or a placebo tablet was administered transvaginally to 24 healthy women.In step 2, RKP00156 at a dose of 10, 25, or 50 mg or a placebo tablet was administered once daily for 4 weeks in 62 patients with CIN2. The primary endpoints of this trial were the safety of RKP00156 and the change in the human papillomavirus (HPV) viral load.
Results:
A total of 86 patients were enrolled and randomized. RKP00156 administration did not cause serious drug-associated adverse events (AEs). Although no significant difference in the HPV viral load was found between the experimental and placebo groups, a reduction in the HPV viral load was observed in the 25 mg-dose group (−98.61%; 95% confidence interval=−99.83%, 4.52%; p=0.046) after treatment completion in patients with a high HPV viral load, despite a lack of statistical power. No differences in histologic regression and HPV clearance were observed.
Conclusion
The safety of RKP00156 was proved with no serious AEs. Although the study did not show any significance in histologic regression and HPV clearance, our findings indicate that RKP00156 may have a possibility of short-term inhibitory effect on HPV replication in patients with higher viral loads.
10.Clinical Feasibility of Vascular Navigation System During Laparoscopic Gastrectomy for Gastric Cancer: A Retrospective Comparison With Propensity-Score Matching
Ji Eun JUNG ; Jeong Ho SONG ; Seyeol OH ; Sang-Yong SON ; Hoon HUR ; In Gyu KWON ; Sang-Uk HAN
Journal of Gastric Cancer 2024;24(4):356-366
Purpose:
The usability of a new surgical navigation system that provides patient-specific vascular information for robotic gastrectomy in gastric cancer remains unexplored for laparoscopic gastrectomy owing to differences in surgical environments. This study aimed to evaluate the applicability and safety of this navigation system in laparoscopic gastrectomy and to compare the post-operative outcomes between procedures with and without its use.
Materials and Methods:
Between June 2022 and July 2023, 38 patients across 2 institutions underwent laparoscopic gastrectomy using a navigation system (navigation group). The technical feasibility, safety, and accuracy of detecting variations in vascular anatomy were measured. The perioperative outcomes were compared with 114 patients who underwent laparoscopic gastrectomy without a navigation system (non-navigation group) using 1:3 propensity score matching during the same study period.
Results:
In all patients in the navigation group, no adverse events associated with the navigation system occurred during surgery in any patient in the navigation group. No accidental vessel injuries necessitate auxiliary procedures. All vessels encountered during the gastrectomy were successfully reconstructed and visualized. Patient demographics and operative data were comparable between the 2 groups. The navigation group exhibited a significantly lower overall complication rate (10.5%) than the non-navigation group (26.3%, P=0.043). Notably, pancreas-related complications were absent in the navigation group but occurred in eight cases in the non-navigation group (7.0%, P=0.093), although the difference was not statistically significant.
Conclusions
The patient-specific surgical navigation system demonstrated clinical feasibility and safety for laparoscopic gastrectomy for gastric cancer, potentially reducing complication rates compared with laparoscopic gastrectomy without its use.

Result Analysis
Print
Save
E-mail