1.A Randomized Trial of Sentinel Node Biopsy Omission After Neoadjuvant Systemic Therapy in Clinically Node-Negative or Selected Node-Positive Breast Cancer
Ji-Jung JUNG ; Hee Jeong KIM ; Byung Joo CHAE ; Eun-Kyu KIM ; Jee Hyun AHN ; Joon JEONG ; Seeyoun LEE ; Seung Pil JUNG ; Joohyun WOO ; Junwon MIN ; Jong-Ho CHEUN ; Min Sung CHUNG ; Kyung Hwan SHIN ; Jung Min CHANG ; Woo Kyung MOON ; Wonshik HAN
Journal of Breast Cancer 2025;28(6):437-447
Purpose:
Axillary surgery is increasingly omitted in patients with early-stage breast cancer undergoing upfront surgery, as supported by trials such as SOUND and INSEMA. However, in the neoadjuvant setting, the omission of axillary surgery has only been explored in small single-arm studies involving highly selected patients with confirmed breast pathologic complete response (pCR). The NeoNAUTILUS trial aimed to evaluate the oncologic safety of omitting sentinel lymph node biopsy (SLNB) in patients with a high probability of achieving an axillary pCR (ypN0) following neoadjuvant systemic therapy (NST), regardless of breast pCR status.
Methods
NeoNAUTILUS is a prospective, multicenter, randomized, controlled, noninferiority trial conducted at 12 tertiary centers in Korea. Eligible participants were women with clinical T1–T3, N0, or selected N1 invasive breast cancer, who completed NST and were candidates for breast-conserving surgery (BCS). Prior to enrollment, all patients underwent axillary ultrasound after NST completion to exclude suspicious lymph nodes. Patients with clinical N0 disease of any subtype were eligible for inclusion. Patients with clinical N1 disease with human epidermal growth factor receptor 2-positive or triple-negative tumors may be included if their primary tumor demonstrates a > 30% reduction on magnetic resonance imaging after NST. Participants were randomized 1:1 to undergo BCS with or without SLNB, stratified by clinical nodal status and tumor subtype. Patients were randomized and remained blinded until surgery. The primary endpoint is the 5-year invasive disease-free survival. A total of 464 patients are expected to be enrolled over 3 years, with a 5-year follow-up period.Discussion: NeoNAUTILUS is the first randomized trial to assess the omission of axillary surgery after NST based on the predicted nodal response, independent of breast pCR. This study may redefine axillary management in the neoadjuvant setting by identifying patients who can safely avoid SLNB, thereby reducing surgical morbidity without compromising oncologic outcomes.
2.Clinical Outcome after Everolimus-Eluting Stent Implantation for Small Vessel Coronary Artery Disease: XIENCE Asia Small Vessel Study
Doo Sun SIM ; Dae Young HYUN ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG ; Sang Rok LEE ; Jei Keon CHAE ; Keun Ho PARK ; Young Youp KOH ; Kyeong Ho YUN ; Seok Kyu OH ; Seung Jae JOO ; Sun Ho HWANG ; Jong Pil PARK ; Jay Young RHEW ; Su Hyun KIM ; Jang Hyun CHO ; Seung Uk LEE ; Dong Goo KANG
Chonnam Medical Journal 2024;60(1):78-86
There are limited data on outcomes after implantation of everolimus-eluting stents (EES) in East Asian patients with small vessel coronary lesions. A total of 1,600 patients treated with XIENCE EES (Abbott Vascular, CA, USA) were divided into the small vessel group treated with one ≤2.5 mm stent (n=119) and the non-small vessel group treated with one ≥2.75 mm stent (n=933). The primary end point was a patient-oriented composite outcome (POCO), a composite of all-cause death, myocardial infarction (MI), and any repeat revascularization at 12 months. The key secondary end point was a device-oriented composite outcome (DOCO), a composite of cardiovascular death, target-vessel MI, and target lesion revascularization at 12 months. The small vessel group was more often female, hypertensive, less likely to present with ST-elevation MI, and more often treated for the left circumflex artery, whereas the non-small vessel group more often had type B2/C lesions, underwent intravascular ultrasound, and received unfractionated heparin. In the propensity matched cohort, the mean stent diameter was 2.5±0.0 mm and 3.1±0.4 mm in the small and non-small vessel groups, respectively. Propensity-adjusted POCO at 12 months was 6.0% in the small vessel group and 4.3% in the non-small vessel group (p=0.558). There was no significant difference in DOCO at 12 months (small vessel group: 4.3% and non-small vessel group: 1.7%, p=0.270).Outcomes of XIENCE EES for small vessel disease were comparable to those for non-small vessel disease at 12-month clinical follow-up in real-world Korean patients.
3.Usefulness of meshed SurgiMend in direct-to-implant breast reconstruction
Pil Seon EO ; Joon Seok LEE ; Jeong Woo LEE ; Kang Young CHOI ; Ho Yun CHUNG ; Byung Chae CHO ; Jeeyeon LEE ; Ho Yong PARK ; Jung Dug YANG
Archives of Aesthetic Plastic Surgery 2021;27(2):69-75
Background:
The use of acellular dermal matrix in implant-based breast reconstruction immediately after mastectomy has attracted attention in recent years because it yields good outcomes. Herein, we analyzed the usefulness of meshed SurgiMend in direct-to-implant (DTI) breast reconstruction.
Methods:
In this retrospective single-center analysis, 44 one-stage breast reconstructions using SurgiMend were performed in 42 patients from May 2016 to December 2017. The implant was inserted into the subpectoral plane and SurgiMend was applied to the inferolateral part that lacked tissues to wrap the silicone implant. In 19 patients (20 breasts), fenestration was performed with SurgiMend, while in the remaining 23 patients (24 breasts), SurgiMend that was meshed at a ratio of 1:1.5 was used. We analyzed the frequency of complications. Patient satisfaction was compared and analyzed using a five-item questionnaire (shape, texture, symmetry, pain, and overall outcome).
Results:
The average age of the patients was 43.2 years, and their mean body mass index was 21.1 kg/m2. The average follow-up period was 24.0 months. In the control (fenestrated SurgiMend) and experimental (meshed SurgiMend) groups, major seroma occurred in five of the 20 breasts (25.0%) and two of the 24 breasts (8.3%), respectively. Minor complications were resolved with conservative treatment. The patient satisfaction score for shape, texture, symmetry, pain, and overall satisfaction was 4.3, 4.1, 4.7, 4.5, and 4.4, respectively.
Conclusions
Applying meshed SurgiMend in DTI breast reconstruction is a useful surgical technique.
4.Usefulness of meshed SurgiMend in direct-to-implant breast reconstruction
Pil Seon EO ; Joon Seok LEE ; Jeong Woo LEE ; Kang Young CHOI ; Ho Yun CHUNG ; Byung Chae CHO ; Jeeyeon LEE ; Ho Yong PARK ; Jung Dug YANG
Archives of Aesthetic Plastic Surgery 2021;27(2):69-75
Background:
The use of acellular dermal matrix in implant-based breast reconstruction immediately after mastectomy has attracted attention in recent years because it yields good outcomes. Herein, we analyzed the usefulness of meshed SurgiMend in direct-to-implant (DTI) breast reconstruction.
Methods:
In this retrospective single-center analysis, 44 one-stage breast reconstructions using SurgiMend were performed in 42 patients from May 2016 to December 2017. The implant was inserted into the subpectoral plane and SurgiMend was applied to the inferolateral part that lacked tissues to wrap the silicone implant. In 19 patients (20 breasts), fenestration was performed with SurgiMend, while in the remaining 23 patients (24 breasts), SurgiMend that was meshed at a ratio of 1:1.5 was used. We analyzed the frequency of complications. Patient satisfaction was compared and analyzed using a five-item questionnaire (shape, texture, symmetry, pain, and overall outcome).
Results:
The average age of the patients was 43.2 years, and their mean body mass index was 21.1 kg/m2. The average follow-up period was 24.0 months. In the control (fenestrated SurgiMend) and experimental (meshed SurgiMend) groups, major seroma occurred in five of the 20 breasts (25.0%) and two of the 24 breasts (8.3%), respectively. Minor complications were resolved with conservative treatment. The patient satisfaction score for shape, texture, symmetry, pain, and overall satisfaction was 4.3, 4.1, 4.7, 4.5, and 4.4, respectively.
Conclusions
Applying meshed SurgiMend in DTI breast reconstruction is a useful surgical technique.
5.Usefulness of Near-infrared Spectroscopy for Diagnosis of Traumatic Intracranial Hemorrhage in Postmortem Inspection
Jong Pil PARK ; Tak Su LEE ; Minsung CHOI ; Kyung moo YANG ; Jeongwoo PARK ; Yujin WON ; Seung Gyu CHOI ; Kyunghong LEE ; Jeong Hwan KIM ; Chae Lin KANG ; Seung Woo CHOI
Korean Journal of Legal Medicine 2020;44(1):24-30
Near-infrared spectroscopy is a device used to determine whether traumatic intracranial hemorrhage has occurred and is primarily used for screening in emergency situations. In this study we examined the applicability of this equipment in postmortem inspection. This study included 124 autopsy cases and 59 postmortem inspection cases performed in the National Forensic Service from July 2017 to October 2018. We carried out the test using Infrascanner Model 2000 (Infrascan Inc.). Autopsy cases were divided into four groups (epidural hemorrhage or subdural hemorrhage group, traumatic subarachnoid hemorrhage or cerebral contusion group, nontraumatic intracerebral hemorrhage group, and control group) and analyzed. There was no difference in the test results according to the presence and type of intracranial hemorrhage. The possibility that variables related to postmortem change affected the test results was considered. In conclusion, this study confirmed that near-infrared spectroscopy is not suitable for the detection of traumatic intracranial hemorrhage in postmortem inspection.
6.Usefulness of Near-infrared Spectroscopy for Diagnosis of Traumatic Intracranial Hemorrhage in Postmortem Inspection
Jong Pil PARK ; Tak Su LEE ; Minsung CHOI ; Kyung moo YANG ; Jeongwoo PARK ; Yujin WON ; Seung Gyu CHOI ; Kyunghong LEE ; Jeong Hwan KIM ; Chae Lin KANG ; Seung Woo CHOI
Korean Journal of Legal Medicine 2020;44(1):24-30
Near-infrared spectroscopy is a device used to determine whether traumatic intracranial hemorrhage has occurred and is primarily used for screening in emergency situations. In this study we examined the applicability of this equipment in postmortem inspection. This study included 124 autopsy cases and 59 postmortem inspection cases performed in the National Forensic Service from July 2017 to October 2018. We carried out the test using Infrascanner Model 2000 (Infrascan Inc.). Autopsy cases were divided into four groups (epidural hemorrhage or subdural hemorrhage group, traumatic subarachnoid hemorrhage or cerebral contusion group, nontraumatic intracerebral hemorrhage group, and control group) and analyzed. There was no difference in the test results according to the presence and type of intracranial hemorrhage. The possibility that variables related to postmortem change affected the test results was considered. In conclusion, this study confirmed that near-infrared spectroscopy is not suitable for the detection of traumatic intracranial hemorrhage in postmortem inspection.
7.Usefulness of Near-infrared Spectroscopy for Diagnosis of Traumatic Intracranial Hemorrhage in Postmortem Inspection
Jong Pil PARK ; Tak Su LEE ; Minsung CHOI ; Kyung moo YANG ; Jeongwoo PARK ; Yujin WON ; Seung Gyu CHOI ; Kyunghong LEE ; Jeong Hwan KIM ; Chae Lin KANG ; Seung Woo CHOI
Korean Journal of Legal Medicine 2020;44(1):24-30
Near-infrared spectroscopy is a device used to determine whether traumatic intracranial hemorrhage has occurred and is primarily used for screening in emergency situations. In this study we examined the applicability of this equipment in postmortem inspection. This study included 124 autopsy cases and 59 postmortem inspection cases performed in the National Forensic Service from July 2017 to October 2018. We carried out the test using Infrascanner Model 2000 (Infrascan Inc.). Autopsy cases were divided into four groups (epidural hemorrhage or subdural hemorrhage group, traumatic subarachnoid hemorrhage or cerebral contusion group, nontraumatic intracerebral hemorrhage group, and control group) and analyzed. There was no difference in the test results according to the presence and type of intracranial hemorrhage. The possibility that variables related to postmortem change affected the test results was considered. In conclusion, this study confirmed that near-infrared spectroscopy is not suitable for the detection of traumatic intracranial hemorrhage in postmortem inspection.
8.Use of Abnobaviscum to treat refractory seroma after breast reconstruction with a latissimus dorsi flap: A case report
Jong Seong KIM ; Pil Seon EO ; Joon Seok LEE ; Jeong Woo LEE ; Ho Yun CHUNG ; Byung Chae CHO ; Kang Young CHOI ; Ho Young PARK ; Jung Dug YANG
Archives of Aesthetic Plastic Surgery 2019;25(2):73-78
In recent years, there has been a notable increase in the rate of refractory donor site seroma, defined as seroma that persists for at least 3 months postoperatively, as the number of breast reconstructions using a latissimus dorsi (LD) musculocutaneous flap has increased. Various factors have been proposed to be related, including smoking, obesity, flap mass, and body weight, and several studies have been conducted to explore treatment methods. Typically, surgical treatment, such as capsulectomy, has been considered for refractory seroma, but in this case report, we describe positive outcomes achieved by using Abnobaviscum to treat three female patients who developed a donor site seroma at least 3 months after breast reconstruction using an LD flap.
Body Weight
;
Breast
;
Female
;
Humans
;
Mammaplasty
;
Myocutaneous Flap
;
Obesity
;
Seroma
;
Smoke
;
Smoking
;
Superficial Back Muscles
;
Tissue Donors
9.Safety and Efficacy of the Endeavor Resolute® Stent in Patients with Multivessel Disease: The HEART (Honam EndeAvor ResoluTe) Prospective, Multicenter Trial
Doo Sun SIM ; Myung Ho JEONG ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Keun Ho PARK ; Sun Ho HWANG ; Dong Goo KANG ; Seung Uk LEE ; Joon Woo KIM ; Jong Pil PARK ; Jay Young RHEW ; Sang Rok LEE ; Jei Keon CHAE ; Kyeong Ho YUN ; Seok Kyu OH ; Won You KANG ; Su Hyun KIM ; Jang Hyun CHO
Chonnam Medical Journal 2018;54(1):55-62
The Endeavor Resolute® (ER) is a zotarolimus-eluting stent (ZES) with a biocompatible BioLinx polymer. This study prospectively compared the clinical outcomes of 2 versions of ZES, ER and Endeavor Sprint® (ES), in patients with multivessel disease. A total of 488 patients who underwent multivessel percutaneous coronary intervention (PCI) were divided into 2 groups the ER group (n=288) and the ES group (n=200). The primary endpoint was a composite of major adverse cardiac events (MACE) consisting of death, myocardial infarction, and target vessel revascularization after 12 months. In all patients, the prevalence of diabetes was higher in the ER group (42.7% vs. 31.0%, p=0.009). The rate of post-PCI Thrombolysis in Myocardial Infarction flow grade 3 was higher in the ER group (100.0% vs. 98.0%, p=0.028). There were no between-group differences in the in-hospital, 1-month and 12-month clinical outcomes. In the propensity score matched cohort (n=200 in each group), no differences were observed in the baseline and procedural characteristics. There were no statistical differences in the rates of in-hospital, 1-month and 12-month events (12-month MACE in the ER and ES groups: 6.0% vs. 3.5%, p=0.240, respectively). The safety and efficacy of both versions of ZES were comparable in patients with multivessel disease during a 12-month clinical follow-up.
Cohort Studies
;
Coronary Artery Disease
;
Drug-Eluting Stents
;
Follow-Up Studies
;
Heart
;
Humans
;
Multicenter Studies as Topic
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Polymers
;
Prevalence
;
Propensity Score
;
Prospective Studies
;
Stents
10.Effects of Baicalin on Oral Pharmacokinetics of Caffeine in Rats.
Keumhan NOH ; Mahesh Raj NEPAL ; Ki Sun JEONG ; Sun A KIM ; Yeon Ji UM ; Chae Shin SEO ; Mi Jeong KANG ; Pil Hoon PARK ; Wonku KANG ; Hye Gwang JEONG ; Tae Cheon JEONG
Biomolecules & Therapeutics 2015;23(2):201-206
Scutellaria baicalensis is one of the most widely used herbal medicines in East Asia. Because baicalein and baicalin are major components of this herb, it is important to understand the effects of these compounds on drug metabolizing enzymes, such as cytochrome P450 (CYP), for evaluating herb-drug interaction. The effects of baicalin and baicalein on activities of ethoxyresorufin O-deethylase (EROD), methoxyresorufin O-demethylase (MROD), benzyloxyresorufin O-debenzylase (BROD), p-nitrophenol hydroxylase and erythromycin N-demethylase were assessed in rat liver microsomes in the present study. In addition, the pharmacokinetics of caffeine and its three metabolites (i.e., paraxanthine, theobromine and theophylline) in baicalin-treated rats were compared with untreated control. As results, EROD, MROD and BROD activities were inhibited by both baicalin and baicalein. However, there were no significant differences in the pharmacokinetic parameters of oral caffeine and its three metabolites between control and baicalin-treated rats. When the plasma concentration of baicalin was determined, the maximum concentration of baicalin was below the estimated IC50 values observed in vitro. In conclusion, baicalin had no effects on the pharmacokinetics of caffeine and its metabolites in vivo, following single oral administration in rats.
Administration, Oral
;
Animals
;
Caffeine*
;
Cytochrome P-450 CYP1A1
;
Cytochrome P-450 CYP2B1
;
Cytochrome P-450 CYP3A
;
Cytochrome P-450 Enzyme System
;
Drug Interactions
;
Far East
;
Herb-Drug Interactions
;
Inhibitory Concentration 50
;
Microsomes, Liver
;
Pharmacokinetics*
;
Plasma
;
Rats*
;
Scutellaria baicalensis
;
Theobromine

Result Analysis
Print
Save
E-mail