1.The Emerging Patterns of New Psychoactive Substance–Related Fatalities in South Korea: A Retrospective Study of Forensic Autopsy Cases
Sohyung PARK ; Han Na KIM ; Youngjin JEON ; Minjung KIM ; Seon Jung JANG ; Jeong Hwa KWON
Korean Journal of Legal Medicine 2026;50(2):39-52
New psychoactive substances (NPS) have rapidly emerged in illicit drug markets worldwide and are increasingly encountered in postmortem examinations. However, postmortem data on NPS-related deaths remain limited worldwide. This study describes postmortem findings from forensic autopsy cases in which NPS were detected and explores the characteristics of these deaths through a retrospective review. Six postmortem cases were identified between 2023 and 2024. The cases predominantly involved young adults. Toxicological analysis identified synthetic cannabinoids, dissociatives, and a stimulant, either alone or in combination with alcohol or conventional illicit drugs such as methamphetamine and 3,4-methylenedioxymethamphetamine (MDMA). Drug paraphernalia or a documented history of drug use was identified in only some cases. The causes of death included acute intoxication and traumatic deaths in which drug intoxication may have contributed to abnormal behavior and fatal outcomes. These findings provide preliminary forensic evidence of the emergence of NPS in South Korea. They underscore the importance of postmortem examination with comprehensive toxicological screening and continued surveillance of emerging psychoactive substances in forensic practice. They also suggest the value of reviewing a history of prior substance use even in unexpected sudden deaths not initially suspected to be drugrelated.
2.Ultrasound Imaging Features Associated With Neoplastic Gallbladder Polyps: A Systematic Review and Meta-Analysis
Sunyoung LEE ; Won CHANG ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Hyun-Soo ZHANG ; Jeong Hee YOON
Korean Journal of Radiology 2026;27(4):332-343
Objective:
Although most gallbladder polyps are benign, some neoplastic polyps may be malignant or may serve as precursors to malignancy. Distinguishing neoplastic and non-neoplastic polyps using imaging examinations remains a major challenge.This meta-analysis aimed to identify the ultrasound (US) features that are significantly associated with neoplastic polyps.
Materials and Methods:
The MEDLINE, EMBASE, Cochrane, and KoreaMed databases were searched for articles published up to August 31, 2025. Bivariate random-effects models were used to calculate the meta-analytic pooled diagnostic odds ratios (DORs), sensitivities, and specificities, along with their 95% confidence intervals (CIs), for each US imaging feature in the diagnosis of neoplastic polyps.
Results:
Thirty studies evaluating 8,953 patients, including 1,216 (13.6%) patients with neoplastic polyps, were included.Among the nine evaluated US imaging features, namely, size ≥10 mm, sessile morphology, single polyp, coexisting gallstones, hypoechogenicity, heterogeneous echogenicity, gallbladder wall thickening (GBWT), absence of hyperechoic spot, and vascularity, eight were significantly associated with neoplastic polyps: size ≥10 mm (DOR: 6.23 [95% CI: 1.86– 20.90]), sessile morphology (DOR: 3.54 [1.93–5.97]), single polyp (DOR: 2.21 [1.76–2.74]), coexisting gallstones (DOR:1.86 [1.29–2.60]), hypoechogenicity (DOR: 3.55 [1.47–7.30]), GBWT (DOR: 9.38 [1.47–32.20]), absence of hyperechoic spots (DOR: 4.23 [2.46–6.83]), and vascularity (DOR: 9.72 [5.81–15.30]). Of these, size ≥10 mm demonstrated the highest pooled sensitivity (0.79 [95% CI: 0.68–0.87]), whereas hypoechogenicity showed the highest pooled specificity (0.93 [95% CI: 0.82–0.98]).
Conclusion
Eight US imaging features (size ≥10 mm, sessile morphology, single polyp, coexisting gallstones, hypoechogenicity, GBWT, absence of hyperechoic spots, and vascularity) were significantly associated with the presence of neoplastic polyps.These features may facilitate the management of gallbladder polyps.
3.Clinical Guideline for the Use of Biodegradable Rectal Spacers During Radiotherapy for Prostate Cancer
Hyun Ho HAN ; Jong Kyou KWON ; Do Kyung KIM ; Jin Hyung JEON ; Chan Woo WEE ; Jae Ho CHO ; Ji Hee JUNG ; A Young YOO ; Jae Young JOUNG ; Gee Hyun SONG ; Seung Ju LEE ; Won PARK ; Chan Kyo KIM ; Young Seok KIM ; Yeon Joo KIM ; Ah Ram CHANG ; Jae Sik KIM ; Sung Hwan BAE ; Byoung Kyu HAN ; Kang Su CHO
Journal of Urologic Oncology 2026;24(1):3-12
Purpose:
Radiotherapy (RT) remains a cornerstone of curative treatment for localized and locally advanced prostate cancer. However, dose escalation to improve tumor control is often constrained by the proximity of the rectum, which increases the risk of gastrointestinal (GI) and genitourinary toxicities. Biodegradable rectal spacers inserted between the prostate and rectum have emerged as an effective approach to reduce rectal radiation exposure. This guideline provides evidence-based recommendations on indications, contraindications, procedural standards, and clinical management for biodegradable rectal spacer insertion during prostate cancer RT.
Materials and Methods:
This guideline was developed by a multidisciplinary expert panel through a systematic review of the literature, analysis of international guidelines (National Comprehensive Cancer Network, European Association of Urology, American Society for Radiation Oncology), and expert consensus among radiation oncologists, radiologists, and urologists with clinical experience in spacer insertion. The strength of each recommendation and the level of evidence were classified according to the modified GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) system.
Results:
Spacer insertion is conditionally recommended (Grade C, Level I) for patients receiving definitive external-beam RT without rectal invasion. It reduces the high-dose rectal irradiation volume (V70–75) by >50%, decreases acute GI toxicity, and helps maintain bowel-related quality of life. However, the benefit for late severe toxicity (grade 2 or higher) remains debated in recent meta-analyses. Contraindications include rectal invasion, anatomical inaccessibility, infection, and material hypersensitivity. Procedures should be performed under local anesthesia in a sterile environment by trained physicians. Short-course antibiotics and simulator-based training, including completion of multiple supervised cases, are advised.
Conclusion
Biodegradable rectal spacer insertion is clinically validated and effective in reducing acute rectal toxicity. Although pivotal trials demonstrated a favorable procedural safety profile, real-world postmarket data include reports of rare but severe procedural complications. This guideline provides standardized recommendations tailored to Korean clinical practice while remaining consistent with international standards, emphasizing the importance of operator training and careful patient selection.
4.Lead augmented vector right T wave and elevated E/e′ ratio identify hemodialysis patients at high cardiovascular risk
Juyeon PARK ; Daseul HUH ; In Mee HAN ; Youn Kyung KEE ; Hee Jung JEON ; Jieun OH ; Dong Ho SHIN
Kidney Research and Clinical Practice 2026;45(1):120-129
Background:
This study was performed to evaluate the prognostic utility of a positive T wave in lead augmented vector right (TaVR) and elevated E/e′ ratio in predicting major adverse cardiovascular events (MACE) in patients receiving maintenance hemodialysis.
Methods:
We retrospectively examined 296 adults on thrice-weekly hemodialysis with baseline electrocardiography and transthoracic echocardiography (October 2018–April 2024). TaVR positivity was T-wave amplitude, >0 mV and high E/e′, ≥19. Primary outcome was the first MACE—cardiovascular death, myocardial infarction, stroke, heart-failure admission, or revascularization. Multivariable Cox models adjusted for clinical covariates; incremental value was gauged with Harrell’s C-index, integrated discrimination improvement (IDI), and continuous net reclassification improvement (NRI). Sensitivity analysis was performed using a guideline-recommended E/e′ threshold of ≥15 to assess robustness.
Results:
Over 56.5 months (1,325 patient-years), 118 MACE occurred (8.9/100 patient-years). Incidence was higher with TaVR positivity than negativity (16.0/100 patient-years vs. 3.7/100 patient-years; log-rank p < 0.001). Adjusted hazard ratios were 3.19 (95% confidence interval [CI], 2.00–5.08) for TaVR and 2.92 (95% CI, 1.71–4.96) for high E/e′. Adding both markers to the clinical model increased the C-index from 0.65 to 0.75 (Δ 0.10) and improved IDI (0.10) and NRI (0.16) (all p < 0.01). A significant negative interaction (hazard ratio, 0.21; p = 0.01) indicated complementary but partly overlapping information. Sensitivity results were similar.
Conclusion
TaVR positivity is a strong independent electrocardiography predictor of cardiovascular events in hemodialysis. Combining TaVR with E/e′ adds prognostic value and supports a pragmatic two-step strategy— electrocardiography triage followed by focused echocardiography—for cardiovascular risk stratification in this high-risk population.
5.Induced Pluripotent Stem Cells Derived CD71+CD235a+ Erythroblasts Were Increased by Sirtuin 1 Activator
Changyeong KIM ; Kyung Hwan PARK ; Soo-Been JEON ; A-Reum HAN ; Ji Yoon LEE ; Young-sup YOON
International Journal of Stem Cells 2026;19(1):83-92
Induced pluripotent stem cells (iPSCs) are a promising cell source for regenerative medicine. Clinical applications require a large number of functional red blood cells (RBCs), making it essential to ensure the proliferation of actively dividing, nucleated erythroblasts derived from iPSCs. Small molecules can enhance the efficiency and frequency of iPSC-derived cell differentiation. Sirtuin 1, a key enzyme in multiple biological processes, has been implicated in enhancing iPSC-derived cell differentiation. However, the specific effects of Sirtuin 1 on erythroblast proliferation from iPSCs remain unclear. Here, we developed a protocol to examine the effects of Sirtuin 1 on erythroblasts after endothelial-to-hematopoietic transition (EHT). We found that Sirtuin 1 activation increased the frequency of CD71+CD235a+erythroblasts at the early stage after EHT, suggesting a role for Sirtuin 1 in the proliferation of these specified erythroblasts. These findings reveal that Sirtuin 1 activation benefits erythroblast proliferation and could be considered for translational application in large-scale RBC culture.
6.Persistent influence of past obesity on current adiponectin levels and mortality in patients with type 2 diabetes
Min-Ji KIM ; Sung-Woo KIM ; Bitna HA ; Hyang Sook KIM ; So-Hee KWON ; Jonghwa JIN ; Yeon-Kyung CHOI ; Keun-Gyu PARK ; Jung Guk KIM ; In-Kyu LEE ; Jae-Han JEON
The Korean Journal of Internal Medicine 2025;40(2):299-309
Background/Aims:
Adiponectin, a hormone primarily produced by adipocytes, typically shows an inverse relationship with body mass index (BMI). However, some studies have reported a positive correlation between the two. Thus, this study aimed to examine the relationship between adiponectin level and BMI in diabetic patients, focusing on the impact of past obesity on current adiponectin levels.
Methods:
We conducted an observational study analyzing data from 323 diabetic patients at Kyungpook National University Hospital. Based on past and current BMIs, participants were categorized into never-obese (nn, n = 106), previously obese (on, n = 43), and persistently obese (oo, n = 73) groups based on a BMI threshold of 25 kg/m2. Adiponectin level and BMI were key variables. Kaplan–Meier analysis assessed their impact on all-cause mortality up to August 2023, with survival differences based on adiponectin quartiles and follow-up starting from patient enrollment (2010–2015).
Results:
The analysis revealed a significant inverse correlation between adiponectin level and past maximum BMI. The on group exhibited approximately 10% lower adiponectin levels compared to the nn group. This association remained significant after adjusting for current BMI, age, and sex, highlighting the lasting influence of previous obesity on adiponectin levels. Furthermore, survival analysis indicated that patients in the lowest adiponectin quartile had reduced survival, with a statistically significant trend (p = 0.062).
Conclusions
Findings of this study suggest that lower adiponectin levels, potentially reflecting past obesity, are associated with decreased survival in diabetic patients, underscoring a critical role of adiponectin in long-term health outcomes.
7.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
8.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
9.Epidemiology and Functional Outcome of Acute Stroke Patients in Korea Using Nationwide data
Seungmin SHIN ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Sung-Chul JIN ; Jin Pyeong JEON ; Ji Young LEE ; Boung Chul LEE ; Young Wha LIM ; Gui Ok KIM ; Youg Uk KWON ; Yu Ra LEE ; So Young HAN ; Jae Sang OH
Journal of Korean Neurosurgical Society 2025;68(2):159-176
Objective:
: Korea’s healthcare system and policy promotes early, actively stroke treatment to improve prognosis. This study represents stroke epidemiology and outcomes in Korea.
Methods:
: This study investigated data from the Acute Stroke Assessment Registry. The registry collects data from over 220 hospitals nationwide, focusing on quality stroke service management. Data analysis included patient demographics, stroke severity assessment, and discharge prognosis measurement using standardized scales.
Results:
: Eighty-six thousand five hundred sixty-eight acute stroke patients were collected with demographic and clinical characteristics during 18 months from 2016, 2018, and between 2020 to 2021, focusing on acute subarachnoid hemorrhage (SAH), acute intracerebral hemorrhage (ICH), and acute ischemic stroke. Of these 86568 patients, 8.3% was SAH, 16.3% ICH, and 74.9% ischemic stroke. Trends showed decreasing SAH and increasing ICH cases over the years. 68.3% stroke patients had the clear onset time. 49.6% stroke patients arrived within 4.5 hours of symptom onset, with more patients treated at general hospitals. Good functional outcomes at discharge was obtained with 58.3% of acute stroke patients, 55.9% of SAH patients, 34.6% of ICH patients, and 63.8% of ischemic stroke patients.
Conclusion
: The results showed that ischemic stroke was the most common subtype, followed by ICH and SAH. Prognosis differed among subtypes, with favorable outcomes more common in ischemic stroke and SAH compared to ICH.
10.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.

Result Analysis
Print
Save
E-mail