1.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
2.Lung Disease Diagnostic Model Through IgG Sensitization to Microbial Extracellular Vesicles
Jinho YANG ; Goohyeon HONG ; Youn-Seup KIM ; Hochan SEO ; Sungwon KIM ; Andrea MCDOWELL ; Won Hee LEE ; You-Sun KIM ; Yeon-Mok OH ; You-Sook CHO ; Young Woo CHOI ; You-Young KIM ; Young-Koo JEE ; Yoon-Keun KIM
Allergy, Asthma & Immunology Research 2020;12(4):669-683
Purpose:
Recently, there has been a rise in the interest to understand the composition of indoor dust due to its association with lung diseases such as asthma, chronic obstructive pulmonary disease (COPD) and lung cancer. Furthermore, it has been found that bacterial extracellular vesicles (EVs) within indoor dust particles can induce pulmonary inflammation, suggesting that these might play a role in lung disease.
Methods:
We performed microbiome analysis of indoor dust EVs isolated from mattresses in apartments and hospitals. We developed diagnostic models based on the bacterial EVs antibodies detected in serum samples via enzyme-linked immunosorbent assay (ELISA) in this analysis.
Results:
Proteobacteria was the most abundant bacterial EV taxa observed at the phylum level while Pseudomonas, Enterobacteriaceae (f) and Acinetobacter were the most prominent organisms at the genus level, followed by Staphylococcus. Based on the microbiome analysis, serum anti-bacterial EV immunoglobulin G (IgG), IgG1 and IgG4 were analyzed using ELISA with EV antibodies that targeted Staphylococcus aureus, Acinetobacter baumannii, Enterobacter cloacae and Pseudomonas aeruginosa. The levels of anti-bacterial EV antibodies were found to be significantly higher in patients with asthma, COPD and lung cancer compared to the healthy control group. We then developed a diagnostic model through logistic regression of antibodies that showed significant differences between groups with smoking history as a covariate. Four different variable selection methods were compared to construct an optimal diagnostic model with area under the curves ranging from 0.72 to 0.81.
Conclusions
The results of this study suggest that ELISA-based analysis of anti-bacterial EV antibodies titers can be used as a diagnostic tool for lung disease. The present findings provide insights into the pathogenesis of lung disease as well as a foundation for developing a novel diagnostic methodology that synergizes microbial EV metagenomics and immune assays.
3.Lung Disease Diagnostic Model Through IgG Sensitization to Microbial Extracellular Vesicles
Jinho YANG ; Goohyeon HONG ; Youn-Seup KIM ; Hochan SEO ; Sungwon KIM ; Andrea MCDOWELL ; Won Hee LEE ; You-Sun KIM ; Yeon-Mok OH ; You-Sook CHO ; Young Woo CHOI ; You-Young KIM ; Young-Koo JEE ; Yoon-Keun KIM
Allergy, Asthma & Immunology Research 2020;12(4):669-683
Purpose:
Recently, there has been a rise in the interest to understand the composition of indoor dust due to its association with lung diseases such as asthma, chronic obstructive pulmonary disease (COPD) and lung cancer. Furthermore, it has been found that bacterial extracellular vesicles (EVs) within indoor dust particles can induce pulmonary inflammation, suggesting that these might play a role in lung disease.
Methods:
We performed microbiome analysis of indoor dust EVs isolated from mattresses in apartments and hospitals. We developed diagnostic models based on the bacterial EVs antibodies detected in serum samples via enzyme-linked immunosorbent assay (ELISA) in this analysis.
Results:
Proteobacteria was the most abundant bacterial EV taxa observed at the phylum level while Pseudomonas, Enterobacteriaceae (f) and Acinetobacter were the most prominent organisms at the genus level, followed by Staphylococcus. Based on the microbiome analysis, serum anti-bacterial EV immunoglobulin G (IgG), IgG1 and IgG4 were analyzed using ELISA with EV antibodies that targeted Staphylococcus aureus, Acinetobacter baumannii, Enterobacter cloacae and Pseudomonas aeruginosa. The levels of anti-bacterial EV antibodies were found to be significantly higher in patients with asthma, COPD and lung cancer compared to the healthy control group. We then developed a diagnostic model through logistic regression of antibodies that showed significant differences between groups with smoking history as a covariate. Four different variable selection methods were compared to construct an optimal diagnostic model with area under the curves ranging from 0.72 to 0.81.
Conclusions
The results of this study suggest that ELISA-based analysis of anti-bacterial EV antibodies titers can be used as a diagnostic tool for lung disease. The present findings provide insights into the pathogenesis of lung disease as well as a foundation for developing a novel diagnostic methodology that synergizes microbial EV metagenomics and immune assays.
4.Validation of the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale
Ji-Hyun CHOI ; Jee-Young LEE ; Jin Whan CHO ; Seong-Beom KO ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Joong-Seok KIM ; Yoon-Joong KIM ; Hyeo-Il MA ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; In-Uk SONG ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Ji-Young KIM ; Ji Sun KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung Kim KIM ; Jinyoung YOUN ; Ji Seon Kim KIM ; Eung Seok OH ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Hyung-Eun PARK ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Mee Young PARK
Journal of Clinical Neurology 2020;16(2):245-253
Background:
and PurposeImpulse-control disorder is an important nonmotor symptom of Parkinson's disease (PD) that can lead to financial and social problems, and be related to a poor quality of life. A nationwide multicenter prospective study was performed with the aim of validating the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale (K-QUIP-RS).
Methods:
The K-QUIP-RS was constructed using forward and backward translation, and pretesting of the prefinal version. PD patients on stable medical condition were recruited from 27 movement-disorder clinics. Participants were assessed using the K-QUIP-RS and evaluated for parkinsonian motor and nonmotor statuses and for PD-related quality of life using a predefined evaluation battery. The test–retest reliability of the K-QUIP-RS was assessed over an interval of 10–14 days, and correlations between the KQUIP-RS and other clinical scales were analyzed.
Results:
This study enrolled 136 patients. The internal consistency of the K-QUIP-RS was indicated by a Cronbach's α coefficient of 0.846, as was the test–retest reliability by a Guttman split-half coefficient of 0.808. The total K-QUIP-RS score was positively correlated with the scores for depression and motivation items on the Unified PD Rating Scale (UPDRS), Montgomery-Asberg Depression Scale, and Rapid-Eye-Movement Sleep-Behavior-Disorders Questionnaire. The total K-QUIP-RS score was also correlated with the scores on part II of the UPDRS and the PD Quality of Life-39 questionnaire, and the dopaminergic medication dose.
Conclusions
The K-QUIP-RS appears to be a reliable assessment tool for impulse-control and related behavioral disturbances in the Korean PD population.
5.Subtypes of Sleep Disturbance in Parkinson's Disease Based on the Cross-Culturally Validated Korean Version of Parkinson's Disease Sleep Scale-2
Hui Jun YANG ; Han Joon KIM ; Seong Beom KOH ; Joong Seok KIM ; Tae Beom AHN ; Sang Myung CHEON ; Jin Whan CHO ; Yoon Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; In Uk SONG ; Ji Young KIM ; Young Hee SUNG ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Sun KIM ; Eung Seok OH ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Sang Jin KIM
Journal of Clinical Neurology 2020;16(1):66-74
BACKGROUND:
AND PURPOSE: This study aimed to determine the clinimetric properties of the Korean version of Parkinson's Disease Sleep Scale-2 (K-PDSS-2) and whether distinct subtypes of sleep disturbance can be empirically identified in patients with Parkinson's disease (PD) using the cross-culturally validated K-PDSS-2.
METHODS:
The internal consistency, test–retest reliability, scale precision, and convergent validity of K-PDSS-2 were assessed in a nationwide, multicenter study of 122 patients with PD. Latent class analysis (LCA) was used to derive subgroups of patients who experienced similar patterns of sleep-related problems and nocturnal disabilities.
RESULTS:
The total K-PDSS-2 score was 11.67±9.87 (mean±standard deviation) at baseline and 12.61±11.17 at the retest. Cronbach's α coefficients of the total K-PDSS-2 scores at baseline and follow-up were 0.851 and 0.880, respectively. The intraclass correlation coefficients over the 2-week study period ranged from 0.672 to 0.848. The total K-PDSS-2 score was strongly correlated with health-related quality of life measures and other corresponding nonmotor scales. LCA revealed three distinct subtypes of sleep disturbance in the study patients: “less-troubled sleepers,â€â€œPD-related nocturnal difficulties,†and “disturbed sleepers.â€
CONCLUSIONS
K-PDSS-2 showed good clinimetric attributes in accordance with previous studies that employed the original version of the PDSS-2, therefore confirming the cross-cultural usefulness of the scale. This study has further documented the first application of an LCA approach for identifying subtypes of sleep disturbance in patients with PD.
6.Reliability of the EOS Imaging System for Assessment of the Spinal and Pelvic Alignment in the Sagittal Plane.
Sang Bum KIM ; Youn Moo HEO ; Cheol Mog HWANG ; Tae Gyun KIM ; Jee Young HONG ; You Gun WON ; Chang Uk HAM ; Young Ki MIN ; Jin Woong YI
Clinics in Orthopedic Surgery 2018;10(4):500-507
BACKGROUND: The sagittal alignment of the spine and pelvis is not only closely related to the overall posture of the body but also to the evaluation and treatment of spine disease. In the last few years, the EOS imaging system, a new low-dose radiation X-ray device, became available for sagittal alignment assessment. However, there has been little research on the reliability of EOS. The purpose of this study was to evaluate the intrarater and interrater reliability of EOS for the sagittal alignment assessment of the spine and pelvis. METHODS: Records of 46 patients were selected from the EOS recording system between November 2016 and April 2017. The exclusion criteria were congenital spinal anomaly and deformity, and previous history of spine and pelvis operation. Sagittal parameters of the spine and pelvis were measured by three examiners three times each using both manual and EOS methods. Means comparison t-test, Pearson bivariate correlation analysis, and reliability analysis by intraclass correlation coefficients (ICCs) for intrarater and interrater reliability were performed using R package “irr.” RESULTS: We found excellent intrarater and interrater reliability of EOS measurements. For intrarater reliability, the ICC ranged from 0.898 to 0.982. For interrater reliability, the ICC ranged from 0.794 to 0.837. We used a paired t-test to compare the values measured by manual and EOS methods: there was no statistically significant difference between the two methods. Correlation analysis also showed a statistically significant positive correlation. CONCLUSIONS: EOS showed excellent reliability for assessment of the sagittal alignment of the spine and pelvis.
Congenital Abnormalities
;
Humans
;
Pelvis
;
Postural Balance
;
Posture
;
Reproducibility of Results
;
Spine
;
Whole Body Imaging
7.Validation of the Korean Version of the Scales for Outcomes in Parkinson's Disease-Sleep
Young Hee SUNG ; Hee Jin KIM ; Seong Beom KOH ; Joong Seok KIM ; Sang Jin KIM ; Sang Myung CHEON ; Jin Whan CHO ; Yoon Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; In Uk SONG ; Han Joon KIM ; Ji Young KIM ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Seon KIM ; Ji Young YUN ; Jin Yong HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Sun KIM ; Eung Seok OH ; Hui Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Tae Beom AHN
Journal of Korean Medical Science 2018;33(2):e14-
BACKGROUND: Sleep problems commonly occur in patients with Parkinson's disease (PD), and are associated with a lower quality of life. The aim of the current study was to translate the English version of the Scales for Outcomes in Parkinson's Disease-Sleep (SCOPA-S) into the Korean version of SCOPA-S (K-SCOPA-S), and to evaluate its reliability and validity for use by Korean-speaking patients with PD. METHODS: In total, 136 patients with PD from 27 movement disorder centres of university-affiliated hospitals in Korea were enrolled in this study. They were assessed using SCOPA, Hoehn and Yahr Scale (HYS), Unified Parkinson's Disease Rating Scale (UPDRS), Parkinson's Disease Sleep Scale 2nd version (PDSS-2), Non-motor Symptoms Scale (NMSS), Montgomery Asberg Depression Scale (MADS), 39-item Parkinson's Disease Questionnaire (PDQ39), Neurogenic Orthostatic Hypotension Questionnaire (NOHQ), and Rapid Eye Movement Sleep Behaviour Disorder Questionnaire (RBDQ). The test-retest reliability was assessed over a time interval of 10–14 days. RESULTS: The internal consistency (Cronbach's α-coefficients) of K-SCOPA-S was 0.88 for nighttime sleep (NS) and 0.75 for daytime sleepiness (DS). Test-retest reliability was 0.88 and 0.85 for the NS and DS, respectively. There was a moderate correlation between the NS sub-score and PDSS-2 total score. The NS and DS sub-scores of K-SCOPA-S were correlated with motor scale such as HYS, and non-motor scales such as UPDRS I, UPDRS II, MADS, NMSS, PDQ39, and NOHQ while the DS sub-score was with RBDQ. CONCLUSION: The K-SCOPA-S exhibited good reliability and validity for the assessment of sleep problems in the Korean patients with PD.
Depression
;
Humans
;
Hypotension, Orthostatic
;
Korea
;
Movement Disorders
;
Parkinson Disease
;
Quality of Life
;
Reproducibility of Results
;
Sleep, REM
;
Weights and Measures
8.Validation of the Korean Version of the Scale for Outcomes in Parkinson's Disease-Autonomic.
Ji Young KIM ; In Uk SONG ; Seong Beom KOH ; Tae Beom AHN ; Sang Jin KIM ; Sang Myung CHEON ; Jin Whan CHO ; Yun Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; Han Joon KIM ; Young Hee SUNG ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Sun KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Young HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Seon KIM ; Eung Seok OH ; Hui Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Joong Seok KIM
Journal of Movement Disorders 2017;10(1):29-34
OBJECTIVE: Autonomic symptoms are commonly observed in patients with Parkinson's disease (PD) and often limit the activities of daily living. The Scale for Outcomes in Parkinson's disease-Autonomic (SCOPA-AUT) was developed to evaluate and quantify autonomic symptoms in PD. The goal of this study was to translate the original SCOPA-AUT, which was written in English, into Korean and to evaluate its reliability and validity for Korean PD patients. METHODS: For the translation, the following processes were performed: forward translation, backward translation, expert review, pretest of the pre-final version and development of the final Korean version of SCOPA-AUT (K-SCOPA-AUT). In total, 127 patients with PD from 31 movement disorder clinics of university-affiliated hospitals in Korea were enrolled in this study. All patients were assessed using the K-SCOPA-AUT and other motor, non-motor, and quality of life scores. Test-retest reliability for the K-SCOPA-AUT was assessed over a time interval of 10−14 days. RESULTS: The internal consistency and reliability of the K-SCOPA-AUT was 0.727 as measured by the mean Cronbach's α-coefficient. The test-retest correlation reliability was 0.859 by the Guttman split-half coefficient. The total K-SCOPA-AUT score showed a positive correlation with other non-motor symptoms [the Korean version of non-motor symptom scale (K-NMSS)], activities of daily living (Unified Parkinson's Disease Rating Scale part II) and quality of life [the Korean version of Parkinson's Disease Quality of Life 39 (K-PDQ39)]. CONCLUSION: The K-SCOPA-AUT had good reliability and validity for the assessment of autonomic dysfunction in Korean PD patients. Autonomic symptom severities were associated with many other motor and non-motor impairments and influenced quality of life.
Activities of Daily Living
;
Humans
;
Korea
;
Movement Disorders
;
Parkinson Disease
;
Quality of Life
;
Reproducibility of Results
9.Three Cases of Cough Syncope in Lung Cancer Patients.
Ka Young KIM ; Seon Ah CHA ; Young Woon KIM ; Hyo Kyeong YU ; Ye Jee LIM ; Si Young YOU ; Sung Kyoung KIM ; Chi Hong KIM ; Hoon Kyo KIM
Tuberculosis and Respiratory Diseases 2012;72(2):236-241
Cough syncope is characterized by the loss of consciousness occurring after vigorous coughings. There are approximately 90 reported cases of cough syncope within the medical literature. Most cases involving middle aged, overweight and chronic bronchitic male smokers. Although many studies have been published in the medical literature, the mechanism and pathophysiology for cough syncope has not been well established. Cough syncope is treated by correcting the underlying cause when identified, or by avoiding conditions that may cause the cough syncope. In addition, cough suppression modalities can also be used. We herein report 3 cases of cough syncope presenting in lung cancer patients.
Cough
;
Humans
;
Lung
;
Lung Neoplasms
;
Male
;
Middle Aged
;
Overweight
;
Syncope
;
Unconsciousness
10.Simultaneous Translocation of Both TCR Loci (14q11) with Rare Partner Loci (Xq22 and 12p13) in a Case of T-lymphoblastic Leukemia.
Dong Hee KANG ; Se Hyung KIM ; Jeong Woo JUN ; Yong Wha LEE ; Hee Bong SHIN ; Jee Young AHN ; Dae Sik HONG ; You Kyoung LEE ; Byung Ryul JEON
Annals of Laboratory Medicine 2012;32(3):220-224
The most common recurrent cytogenetic abnormalities in T-lymphoblastic leukemia (T-acute lymphoblastic leukemia [T-ALL]) involve T-cell receptor (TCR) loci and a variety of partner genes, including HOX11, HOX11L2, MYC, and TAL1. In this report, we present a rare case involving simultaneous translocation of the TCR alpha/delta loci with different partner loci (Xq22 and 12p13); this resulted in a poor prognosis. Chromosomal analysis showed 46,Y,t(X;14)(q22;q11.2),t(12;14)(p13;q11.2) and FISH analysis by using a T-cell receptor alpha delta DNA probe, Split Signal (DakoCytomation, Denmark), showed translocations at the same TCR alpha/delta locus on both chromosomes. FISH with 2 bacterial artificial chromosome clones showed break apart signal, which suggests involvement of the IRS4 gene. To our knowledge, this is the first report of T-ALL in which both TCR alpha/delta loci were translocated with different partner loci, and 1 of the partner loci, Xq22, was a rare translocation partner locus that included IRS4 gene.
Adult
;
Chromosomes, Human, Pair 12
;
Chromosomes, Human, Pair 14
;
Chromosomes, Human, X
;
Genetic Loci
;
Humans
;
Insulin Receptor Substrate Proteins/genetics
;
Karyotyping
;
Male
;
Precursor T-Cell Lymphoblastic Leukemia-Lymphoma/*genetics/pathology
;
Receptors, Antigen, T-Cell/*genetics
;
*Translocation, Genetic

Result Analysis
Print
Save
E-mail